Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added
The §11 Windows table in the Summary PDF doesn't lay out identically across the cohort. Three new quirks added to the layout-style parser so the remaining 5 certs can be debugged with windows actually extracted: 1. `Wood 0.70` combined frame_type+frame_factor line — previously the parser expected them on separate lines (data+1 / data+2) and rejected the window when the joined form appeared. 2. Trailing glazing-type on the data line — `1.22 1.76 2.15 Double pre 2002` is the joined-cell variant in 000516; the W/H/Area anchor now captures the trailing phrase as an optional 4th group and feeds it through as `inline_glazing_type`, bypassing the separate-line glazing-prefix scan. 3. Cross-window gap with no glazing marker — `_partition_after_manuf` now falls back to "second orientation token in gap" when no glazing-type-prefix word appears. Covers the 000516 layout where each window has prefix+suffix orient tokens (no inline orient) and the glazing-type is joined-to-data. The 5 remaining Summary PDFs are copied into `backend/documents_parser/tests/fixtures/` ready for per-cert mapper work. Mirror pin tests deferred — each cert still has its own diff to close (handover in NEXT_AGENT_PROMPT.md documents the per-cert state, e.g. 000477 needs secondary-heating extraction, 000516 needs roof-window separation). Current cohort SAP deltas vs the U985 worksheet PDFs (target 1e-4): 000474 0.0000 ✓ 000477 +6.3655 secondary heating + lighting 000480 +8.2695 diagnosis pending 000487 +8.1433 extractor still drops windows 000490 +5.6551 diagnosis pending 000516 +5.9812 roof-window separation Wider regression stays green (754 pass). Pyright net-zero on touched files. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
parent
29ab80b0e5
commit
00a27efd87
7 changed files with 172 additions and 224 deletions
|
|
@ -417,8 +417,14 @@ class ElmhurstSiteNotesExtractor:
|
||||||
)
|
)
|
||||||
return windows
|
return windows
|
||||||
|
|
||||||
# Anchors used by the layout-style window parser.
|
# Anchors used by the layout-style window parser. The W/H/Area anchor
|
||||||
_WIDTH_HEIGHT_AREA_RE = re.compile(r"^(\d+\.\d+)\s+(\d+\.\d+)\s+(\d+\.\d+)$")
|
# is sometimes followed by a joined glazing-type phrase on the same
|
||||||
|
# line (e.g. '1.22 1.76 2.15 Double pre 2002'); the optional 4th
|
||||||
|
# capture surfaces that text so the parser can use it instead of a
|
||||||
|
# separately-laid-out prefix line.
|
||||||
|
_WIDTH_HEIGHT_AREA_RE = re.compile(
|
||||||
|
r"^(\d+\.\d+)\s+(\d+\.\d+)\s+(\d+\.\d+)(?:\s+(\S.*?))?$"
|
||||||
|
)
|
||||||
_MANUFACTURER_RE = re.compile(r"^(Manufacturer|Default)\s+(\d+\.\d+)$")
|
_MANUFACTURER_RE = re.compile(r"^(Manufacturer|Default)\s+(\d+\.\d+)$")
|
||||||
_ORIENTATION_TOKENS = frozenset({
|
_ORIENTATION_TOKENS = frozenset({
|
||||||
"North", "South", "East", "West", "NE", "NW", "SE", "SW",
|
"North", "South", "East", "West", "NE", "NW", "SE", "SW",
|
||||||
|
|
@ -507,6 +513,28 @@ class ElmhurstSiteNotesExtractor:
|
||||||
return j
|
return j
|
||||||
return None
|
return None
|
||||||
|
|
||||||
|
_FRAME_TYPE_AND_FACTOR_RE = re.compile(r"^(\S+(?:\s+\S+)*?)\s+(\d\.\d+)$")
|
||||||
|
|
||||||
|
def _parse_frame_type_and_factor(
|
||||||
|
self, lines: List[str], data_idx: int
|
||||||
|
) -> tuple[str, Optional[float], int]:
|
||||||
|
"""Return `(frame_type, frame_factor, middle_start_idx)` from
|
||||||
|
the lines immediately after the data anchor. Layout-style cell
|
||||||
|
joining can collapse what's normally two lines ('PVC' then
|
||||||
|
'0.70') into one ('Wood 0.70'); both shapes need to feed the
|
||||||
|
same downstream slice."""
|
||||||
|
combined = self._FRAME_TYPE_AND_FACTOR_RE.match(lines[data_idx + 1].strip())
|
||||||
|
if combined is not None:
|
||||||
|
return combined.group(1), float(combined.group(2)), data_idx + 2
|
||||||
|
if data_idx + 2 >= len(lines):
|
||||||
|
return lines[data_idx + 1].strip(), None, data_idx + 2
|
||||||
|
frame_type = lines[data_idx + 1].strip()
|
||||||
|
try:
|
||||||
|
frame_factor = float(lines[data_idx + 2].strip())
|
||||||
|
except ValueError:
|
||||||
|
return frame_type, None, data_idx + 3
|
||||||
|
return frame_type, frame_factor, data_idx + 3
|
||||||
|
|
||||||
def _partition_after_manuf(
|
def _partition_after_manuf(
|
||||||
self, lines: List[str], manuf_idx: int, next_data_idx: int
|
self, lines: List[str], manuf_idx: int, next_data_idx: int
|
||||||
) -> int:
|
) -> int:
|
||||||
|
|
@ -514,14 +542,25 @@ class ElmhurstSiteNotesExtractor:
|
||||||
block (and the inclusive lower bound for the next window's prefix
|
block (and the inclusive lower bound for the next window's prefix
|
||||||
block). After the manufacturer line come 3 fixed tokens (g_value,
|
block). After the manufacturer line come 3 fixed tokens (g_value,
|
||||||
draught, shutters); the variable suffix lines start at manuf+4
|
draught, shutters); the variable suffix lines start at manuf+4
|
||||||
and run until the next window's glazing-type-start token (e.g.
|
and run until either (a) the next window's glazing-type-start
|
||||||
'Double between 2002', 'Single', 'Triple ...') or until the
|
token (e.g. 'Double between 2002', 'Single', 'Triple ...') or
|
||||||
next window's data line if no such token is present."""
|
(b) the second orientation token in the gap, whichever comes
|
||||||
|
first. Branch (b) covers layouts where the glazing-type is
|
||||||
|
joined to the data line (no separate prefix line exists), so
|
||||||
|
the only signal of window-transition is the orientation tokens
|
||||||
|
rotating: orient_suffix(k) → orient_prefix(k+1). Falls through
|
||||||
|
to `next_data_idx` when neither marker is present."""
|
||||||
scan_start = manuf_idx + 4
|
scan_start = manuf_idx + 4
|
||||||
|
seen_orient = False
|
||||||
for j in range(scan_start, next_data_idx):
|
for j in range(scan_start, next_data_idx):
|
||||||
first_word = lines[j].strip().split(" ", 1)[0]
|
stripped = lines[j].strip()
|
||||||
|
first_word = stripped.split(" ", 1)[0]
|
||||||
if first_word in self._GLAZING_TYPE_PREFIX_WORDS:
|
if first_word in self._GLAZING_TYPE_PREFIX_WORDS:
|
||||||
return j
|
return j
|
||||||
|
if stripped in self._ORIENTATION_TOKENS:
|
||||||
|
if seen_orient:
|
||||||
|
return j
|
||||||
|
seen_orient = True
|
||||||
return next_data_idx
|
return next_data_idx
|
||||||
|
|
||||||
def _parse_window_from_anchors(
|
def _parse_window_from_anchors(
|
||||||
|
|
@ -537,20 +576,28 @@ class ElmhurstSiteNotesExtractor:
|
||||||
width = float(anchor.group(1))
|
width = float(anchor.group(1))
|
||||||
height = float(anchor.group(2))
|
height = float(anchor.group(2))
|
||||||
area = float(anchor.group(3))
|
area = float(anchor.group(3))
|
||||||
|
# Layout-style cell joining sometimes leaves the glazing-type
|
||||||
|
# phrase trailing the W H Area triplet on the same line (e.g.
|
||||||
|
# "1.22 1.76 2.15 Double pre 2002"); when present we pass it
|
||||||
|
# through as `inline_glazing_type` and the composer skips the
|
||||||
|
# would-be glazing-prefix scan.
|
||||||
|
inline_glazing_type = anchor.group(4) if anchor.lastindex and anchor.lastindex >= 4 else None
|
||||||
|
|
||||||
# frame_type and frame_factor immediately follow the data line.
|
# frame_type and frame_factor immediately follow the data line.
|
||||||
if data_idx + 2 >= len(lines):
|
# Layout-style cell joining sometimes collapses them onto a
|
||||||
|
# single "Wood 0.70" line; treat both shapes uniformly so the
|
||||||
|
# downstream `middle` slice still starts at the first variable
|
||||||
|
# field (glazing_gap / bp / location / orient).
|
||||||
|
if data_idx + 1 >= len(lines):
|
||||||
return None
|
return None
|
||||||
frame_type = lines[data_idx + 1].strip()
|
frame_type, frame_factor, middle_start = self._parse_frame_type_and_factor(
|
||||||
try:
|
lines, data_idx
|
||||||
frame_factor = float(lines[data_idx + 2].strip())
|
)
|
||||||
except ValueError:
|
if frame_factor is None or not 0.0 < frame_factor <= 1.0:
|
||||||
return None
|
|
||||||
if not 0.0 < frame_factor <= 1.0:
|
|
||||||
return None
|
return None
|
||||||
|
|
||||||
# Variable-order tokens between frame_factor and Manufacturer.
|
# Variable-order tokens between frame_factor and Manufacturer.
|
||||||
middle = [lines[j].strip() for j in range(data_idx + 3, manuf_idx)]
|
middle = [lines[j].strip() for j in range(middle_start, manuf_idx)]
|
||||||
glazing_gap = next((t for t in middle if "mm" in t.lower()), None)
|
glazing_gap = next((t for t in middle if "mm" in t.lower()), None)
|
||||||
location = next((t for t in middle if "wall" in t.lower()), "External wall")
|
location = next((t for t in middle if "wall" in t.lower()), "External wall")
|
||||||
bp_inline = next((t for t in middle if t in self._BP_INLINE_TOKENS), None)
|
bp_inline = next((t for t in middle if t in self._BP_INLINE_TOKENS), None)
|
||||||
|
|
@ -586,6 +633,7 @@ class ElmhurstSiteNotesExtractor:
|
||||||
after=after,
|
after=after,
|
||||||
bp_inline=bp_inline,
|
bp_inline=bp_inline,
|
||||||
orient_inline=orient_inline,
|
orient_inline=orient_inline,
|
||||||
|
inline_glazing_type=inline_glazing_type,
|
||||||
)
|
)
|
||||||
|
|
||||||
return Window(
|
return Window(
|
||||||
|
|
@ -613,6 +661,7 @@ class ElmhurstSiteNotesExtractor:
|
||||||
after: List[str],
|
after: List[str],
|
||||||
bp_inline: Optional[str],
|
bp_inline: Optional[str],
|
||||||
orient_inline: Optional[str],
|
orient_inline: Optional[str],
|
||||||
|
inline_glazing_type: Optional[str] = None,
|
||||||
) -> tuple[str, str, str]:
|
) -> tuple[str, str, str]:
|
||||||
"""Re-join the glazing-type / building-part / orientation tokens
|
"""Re-join the glazing-type / building-part / orientation tokens
|
||||||
split by the layout preprocessor. Each is at most 2 fragments
|
split by the layout preprocessor. Each is at most 2 fragments
|
||||||
|
|
@ -645,8 +694,13 @@ class ElmhurstSiteNotesExtractor:
|
||||||
bp_prefix_frag = pop_if_bp_fragment(prefix)
|
bp_prefix_frag = pop_if_bp_fragment(prefix)
|
||||||
bp_suffix_frag = pop_if_bp_fragment(suffix)
|
bp_suffix_frag = pop_if_bp_fragment(suffix)
|
||||||
|
|
||||||
# Glazing type: remaining prefix + remaining suffix (joined).
|
# Glazing type: an inline glazing-type captured from the data
|
||||||
glazing_type = " ".join([*prefix, *suffix]).strip()
|
# line (layout-joined variant) wins; otherwise join the remaining
|
||||||
|
# prefix + suffix fragments.
|
||||||
|
if inline_glazing_type is not None:
|
||||||
|
glazing_type = inline_glazing_type
|
||||||
|
else:
|
||||||
|
glazing_type = " ".join([*prefix, *suffix]).strip()
|
||||||
|
|
||||||
# Building part: inline token wins; otherwise join prefix + suffix.
|
# Building part: inline token wins; otherwise join prefix + suffix.
|
||||||
if bp_inline is not None:
|
if bp_inline is not None:
|
||||||
|
|
|
||||||
BIN
backend/documents_parser/tests/fixtures/Summary_000477.pdf
vendored
Normal file
BIN
backend/documents_parser/tests/fixtures/Summary_000477.pdf
vendored
Normal file
Binary file not shown.
BIN
backend/documents_parser/tests/fixtures/Summary_000480.pdf
vendored
Normal file
BIN
backend/documents_parser/tests/fixtures/Summary_000480.pdf
vendored
Normal file
Binary file not shown.
BIN
backend/documents_parser/tests/fixtures/Summary_000487.pdf
vendored
Normal file
BIN
backend/documents_parser/tests/fixtures/Summary_000487.pdf
vendored
Normal file
Binary file not shown.
BIN
backend/documents_parser/tests/fixtures/Summary_000490.pdf
vendored
Normal file
BIN
backend/documents_parser/tests/fixtures/Summary_000490.pdf
vendored
Normal file
Binary file not shown.
BIN
backend/documents_parser/tests/fixtures/Summary_000516.pdf
vendored
Normal file
BIN
backend/documents_parser/tests/fixtures/Summary_000516.pdf
vendored
Normal file
Binary file not shown.
|
|
@ -1,245 +1,139 @@
|
||||||
# Handover — close the Elmhurst Summary→SAP chain to 1e-4
|
# Handover — close the remaining 5 Elmhurst Summary→SAP chains to 1e-4
|
||||||
|
|
||||||
You are picking up branch `ara-backend-design-prd` mid-stream. The
|
You are picking up branch `ara-backend-design-prd` mid-stream. The
|
||||||
previous agent left a near-complete but **not actually complete**
|
previous chain of work closed **Summary_000474** to 1e-4 (Slice 47)
|
||||||
validation chain. This handover is honest about what's done, what's
|
and landed extractor infrastructure that helps the other 5 fixtures
|
||||||
still wrong, and why a fresh approach may help.
|
(Slice 48), but each of the 5 remaining certs still has its own diff
|
||||||
|
to close. This handover captures the exact per-cert state so you
|
||||||
|
don't have to rediscover it.
|
||||||
|
|
||||||
## The 30-second picture
|
## The 30-second picture
|
||||||
|
|
||||||
There are two paths into the calculator:
|
|
||||||
|
|
||||||
```
|
```
|
||||||
Path A: hand-built EpcPropertyData → cascade → SAP 62.2584 ← matches Elmhurst worksheet PDF to 4 d.p. ✓
|
Cert Mapped SAP Target SAP Δ Notes
|
||||||
Path B: Summary_NNNNNN.pdf → extractor → ElmhurstSiteNotes
|
000474 62.2584 62.2584 0.0000 ✓ CLOSED (Slice 47)
|
||||||
→ from_elmhurst_site_notes → EpcPropertyData
|
000477 71.3712 65.0057 +6.3655 secondary heating + lighting
|
||||||
→ cascade → SAP 62.5195 ← off by 0.2611 unrounded SAP points ✗
|
000480 69.5681 61.2986 +8.2695 unknown (largest gap)
|
||||||
|
000487 69.7864 61.6431 +8.1433 window count 1/many (extractor) + others
|
||||||
|
000490 63.0530 57.3979 +5.6551 unknown
|
||||||
|
000516 68.7749 62.7937 +5.9812 roof window separation
|
||||||
```
|
```
|
||||||
|
|
||||||
Both paths feed the same calculator (`calculate_sap_from_inputs`). Path
|
All Δ are positive — the mapper is computing SAP too HIGH, which
|
||||||
A proves the cascade is provably equivalent to Elmhurst's calculator
|
typically means missing cost contributions (secondary heating fuel,
|
||||||
(`sap_score_continuous` = 62.2584 matches Elmhurst worksheet PDF line
|
lighting, etc.) or under-counted heat-loss area.
|
||||||
257 exactly). Path B uses `from_elmhurst_site_notes` instead of the
|
|
||||||
hand-built fixture; **it should produce identical output**, because
|
|
||||||
the Summary PDF and the hand-built fixture encode the same source-of-
|
|
||||||
truth data. It doesn't. The 0.26 SAP gap means information is being
|
|
||||||
dropped in the extractor or mapper.
|
|
||||||
|
|
||||||
The user explicitly rejected "within 0.5 is good enough" — the chain
|
Forcing function for the 000474 case is in:
|
||||||
must reproduce Elmhurst to `1e-4` like every other Elmhurst worksheet
|
`backend/documents_parser/tests/test_summary_pdf_mapper_chain.py::test_summary_000474_full_chain_sap_matches_worksheet_pdf_exactly`
|
||||||
test.
|
(green at 1e-4). When you close each remaining cert, add a mirror
|
||||||
|
test next to it.
|
||||||
|
|
||||||
The end goal is: `api → EpcPropertyData → Sap10 calculator` with
|
## What landed already
|
||||||
`< 0.5` SAP error (the API publishes rounded SAP integers, so half a
|
|
||||||
point is rounding noise). But for the Elmhurst-site-notes path,
|
|
||||||
because Elmhurst's worksheet PDFs publish unrounded line-ref values,
|
|
||||||
the target is **zero error to 1e-4**.
|
|
||||||
|
|
||||||
## Forcing function
|
| Slice | Commit | What |
|
||||||
|
|
||||||
There is one failing test pinning this:
|
|
||||||
|
|
||||||
```
|
|
||||||
backend/documents_parser/tests/test_summary_pdf_mapper_chain.py::
|
|
||||||
test_summary_000474_full_chain_sap_matches_worksheet_pdf_exactly
|
|
||||||
```
|
|
||||||
|
|
||||||
It asserts `abs(mapped_sap - 62.2584) < 1e-4` and currently fails with
|
|
||||||
`Δ = 0.2611`. Your job is to drive it to GREEN.
|
|
||||||
|
|
||||||
## Definition of done
|
|
||||||
|
|
||||||
- The failing test above passes at `1e-4` tolerance.
|
|
||||||
- The two other `test_summary_pdf_mapper_chain.py` tests stay green
|
|
||||||
(`sap_building_parts == 3`, `sap_windows == 7`).
|
|
||||||
- The wider `datatypes/epc/` + `backend/documents_parser/tests/`
|
|
||||||
regression stays green (the 9 pre-existing `test_appendix_u.py`
|
|
||||||
failures and 1 pre-existing 1e-9 FEE-precision failure are
|
|
||||||
unrelated — leave them).
|
|
||||||
- Once 000474 is at 1e-4, replicate the test for the other 5 Summary
|
|
||||||
PDFs (000477, 000480, 000487, 000490, 000516) — files are under
|
|
||||||
`sap worksheets/` at the repo root, **untracked**, copy each into
|
|
||||||
`backend/documents_parser/tests/fixtures/` as you go.
|
|
||||||
- For each cert, pin against the unrounded SAP value lodged in line
|
|
||||||
257 of the corresponding `U985-0001-NNNNNN.pdf` worksheet.
|
|
||||||
|
|
||||||
## What the previous agent did right
|
|
||||||
|
|
||||||
12 commits across the session. The architecturally-load-bearing ones:
|
|
||||||
|
|
||||||
| Slice | Commit | Effect |
|
|
||||||
|---|---|---|
|
|---|---|---|
|
||||||
| 44 | `ea6d4263` | flat_roof_insulation_thickness mapper passthrough |
|
| 47 | `29ab80b0` | `main_heating_category=2` in mapper → pumps_fans 130→160; window-gap partitioned on glazing-type-start marker → fixes W4/W5 orientation mis-classification |
|
||||||
| 45a/b/c | `f08252dc` / `24f35f8b` / `5acbecc5` | PV cascade per Appendix M + U (orientation × pitch × Table-M1 ZPV × rating-vs-demand climate) |
|
| 48 | (this slice) | Extractor handles combined `Wood 0.70` frame line; data anchor allows trailing glazing-type (`1.22 1.76 2.15 Double pre 2002`); partition falls back to second-orient-token when no glazing marker in gap; 5 fixture PDFs copied to `backend/documents_parser/tests/fixtures/` |
|
||||||
| audit pins | `15789f5a` / `acc6331d` / `8ac548ca` | u_wall / u_roof / u_floor description-cascade pins against Tables 6 / 16 / §5.12 — proves U-value cascade is spec-correct on the cohort |
|
|
||||||
| 46 scaffold | `ccf7aa21` | First scaffold test for Summary→EpcPropertyData chain (strict-xfail) |
|
|
||||||
| 46a | `36f2c7bb` | Multi-bp support: schema adds `ExtensionPart`; extractor parses Main + 1st Extension + 2nd Extension subsections in §4/§7/§8/§9 with "As Main: Yes" inheritance; mapper produces a `SapBuildingPart` per bp |
|
|
||||||
| 46b | `066dce19` | Layout-style window parser anchored on `W H Area` data line + `Manufacturer <U>` line — extracts 7 windows from the Summary table layout |
|
|
||||||
| **46c** | **`256a5afe`** | **String→int code translations for every Elmhurst-coded field the cascade reads (age band, wall_construction, wall_insulation_type, main_fuel_type, heat_emitter_type, main_heating_control, orientation); PCDB index parsed from `pcdf_boiler_reference`; floor ordering + 0.25 m upper-storey adjustment + `is_exposed_floor` flag for "above unheated space"** |
|
|
||||||
|
|
||||||
After 46c, mapped SAP is 62.52 vs target 62.26 (`Δ = 0.26`).
|
## Per-cert diff diagnoses (already done — don't re-discover)
|
||||||
|
|
||||||
## What the previous agent got wrong
|
### 000477 — Δ +6.37 — single-BP cert
|
||||||
|
Run `python /tmp/diff_cert.py 000477` to reproduce. Scalar input diffs:
|
||||||
|
- `secondary_heating_fraction`: mapped=**0.0** vs handbuilt=**0.1** ← root cause. Handbuilt has `secondary_heating_type=691` (Electric panel heaters) lodged on `SapHeating`. Mapper doesn't extract from §10 "Secondary heating" Summary PDF section.
|
||||||
|
- `lighting_kwh_per_yr`: mapped=160.88 vs handbuilt=201.68 — bulb count mismatch
|
||||||
|
- `secondary_heating_co2_factor_kg_per_kwh`, `secondary_heating_primary_factor`: None vs populated — downstream of the missing secondary_heating_type
|
||||||
|
|
||||||
**Overclaimed completion at the 0.5-tolerance milestone.** The
|
**Fix**: Extend `ElmhurstSiteNotesExtractor` to extract §10 Secondary heating fields, and `_map_elmhurst_sap_heating` to populate `secondary_heating_type` + `secondary_fuel_type` on the `SapHeating`.
|
||||||
original test was written with a 0.5 tolerance (mirroring the
|
|
||||||
API-cert residual cohort, where the API publishes rounded SAP
|
|
||||||
integers so half a point is just rounding). That's the wrong
|
|
||||||
tolerance for the Elmhurst path: Elmhurst lodges full PDF lines with
|
|
||||||
4-d.p. unrounded values, and our cascade matches them exactly on
|
|
||||||
hand-built inputs. The bar is `1e-4`, not 0.5. The previous agent
|
|
||||||
committed Slice 46c with a 0.5-tolerance pin; this handover has
|
|
||||||
since tightened it to `1e-4` (the failing test above).
|
|
||||||
|
|
||||||
## The remaining diffs (Slice 46c → 1e-4 SAP)
|
### 000487 — Δ +8.14 — only 1 window extracted (should be many)
|
||||||
|
Despite Slice 48's frame-line + data-anchor improvements, the §11
|
||||||
|
table layout of this cert still drops most windows. Run
|
||||||
|
`python /tmp/dump_one.py 000487` to see the parsed window. Inspect
|
||||||
|
the raw layout via `python /tmp/dump_section.py 000487` — the table
|
||||||
|
has a different cell-joining pattern that the current parser hasn't
|
||||||
|
yet covered.
|
||||||
|
|
||||||
After Slice 46c, the only differing `cert_to_inputs(epc)` scalar
|
### 000516 — Δ +5.98 — roof window contamination
|
||||||
fields between mapped and hand-built are:
|
6 vertical windows extracted (correct: 5) — the 6th is actually a
|
||||||
|
**roof window** (`1.05×1.12=1.18 m² U=3.10 NE`, pitch 45°) being
|
||||||
|
treated as vertical. Handbuilt 000516 separates this into
|
||||||
|
`sap_roof_windows=[SapRoofWindow(area_m2=1.18, u_value_raw=3.40,
|
||||||
|
orientation=2 NE, pitch_deg=45.0, ...)]`.
|
||||||
|
|
||||||
```
|
**Fix**: Add roof-window extraction in `ElmhurstSiteNotesExtractor`
|
||||||
hot_water_kwh_per_yr: mapped=2291.7821223353485 handbuilt=2291.7784230242883 (Δ < 0.01 — float drift)
|
(likely a "Roof Windows" subsection of §11). Map to `SapRoofWindow`
|
||||||
pumps_fans_kwh_per_yr: mapped=130.0 handbuilt=160.0 ← 30 kWh, real bug
|
not `SapWindow`.
|
||||||
lighting_kwh_per_yr: mapped=139.94522455112704 handbuilt=139.94522455112707 (Δ < 1e-10 — float noise)
|
|
||||||
pumps_fans_primary_factor: mapped=1.5128000000000001 handbuilt=1.5128 (float repr — harmless)
|
|
||||||
fabric_energy_efficiency_kwh_per_m2_yr: mapped=186.62 handbuilt=186.88 (output, not input — driven by solar gains)
|
|
||||||
```
|
|
||||||
|
|
||||||
Plus a window-orientation mis-classification (see below).
|
### 000480 — Δ +8.27 — diagnosis pending
|
||||||
|
Run `python /tmp/diff_cert.py 000480` to start. Two BPs (Main + ext)
|
||||||
|
extracted correctly, 7 windows extracted. Largest gap of the 5 — may
|
||||||
|
have multiple compounding issues.
|
||||||
|
|
||||||
### Diff #1: `pumps_fans_kwh_per_yr` = 130 vs 160 (30 kWh)
|
### 000490 — Δ +5.66 — diagnosis pending
|
||||||
|
Same: `python /tmp/diff_cert.py 000490`.
|
||||||
|
|
||||||
This is the dominant residual contributor. Search `cert_to_inputs.py`
|
## Probe scripts (already in `/tmp`)
|
||||||
for `pumps_fans_kwh_per_yr` to find what drives it. Likely candidates:
|
|
||||||
- `central_heating_pump_age` (the Summary PDF lodges "Heat pump age:
|
|
||||||
Unknown" but that's the HEAT pump, not the central heating pump —
|
|
||||||
may need a separate field on `ElmhurstSiteNotes.MainHeating`)
|
|
||||||
- Boiler type / FGHRs / weather compensator flags
|
|
||||||
- Some specific Table 4d/4e cascade input we're dropping
|
|
||||||
|
|
||||||
The cascade reads `MainHeatingDetail.central_heating_pump_age: Optional[int]`
|
|
||||||
which the Elmhurst mapper doesn't currently populate.
|
|
||||||
|
|
||||||
### Diff #2: Window [4] orientation mis-classified as SE (4) — should be E (3)
|
|
||||||
|
|
||||||
Mapped windows:
|
|
||||||
```
|
|
||||||
[4] orient=4 (SE) W=1.1 H=1.6 U=2.0
|
|
||||||
```
|
|
||||||
|
|
||||||
Hand-built has TWO East U=2.0 windows totalling 3.74 m² area. Mapped's
|
|
||||||
window [2] (East, 1.98 m²) + window [4] (mis-labelled SE, 1.76 m²) =
|
|
||||||
3.74 m² ✓ — exactly matches. So the layout-style window parser is
|
|
||||||
producing `orientation='East-South'` for window [4] when it should be
|
|
||||||
just `'East'`. Look at `_compose_window_descriptors` in
|
|
||||||
`backend/documents_parser/elmhurst_extractor.py` — the suffix
|
|
||||||
token "South" is being joined with the inline "East" prefix when it
|
|
||||||
shouldn't be (probably the "South" belongs to a different window).
|
|
||||||
|
|
||||||
The window count itself also differs: mapped extracts 7 individual
|
|
||||||
windows, hand-built consolidates to 5 by `(orientation, U)` group with
|
|
||||||
width = total area / 1.0 m. Both should be functionally equivalent
|
|
||||||
to the cascade IF orientations + U-values + total areas all match. So
|
|
||||||
fixing the orientation should close this gap.
|
|
||||||
|
|
||||||
### Diff #3: float-precision noise
|
|
||||||
|
|
||||||
`hot_water_kwh_per_yr` (sub-0.01 kWh) and `lighting_kwh_per_yr`
|
|
||||||
(sub-1e-10 kWh) are downstream of accumulation order in the cascade.
|
|
||||||
`pumps_fans_primary_factor` 1.5128000000000001 vs 1.5128 is a Python
|
|
||||||
float repr quirk. These won't close the SAP gap; ignore them unless
|
|
||||||
the other fixes leave the test slightly red and one of these turns
|
|
||||||
out to be the last decimal.
|
|
||||||
|
|
||||||
## Why a fresh approach may help
|
|
||||||
|
|
||||||
The previous agent's pattern was "fix one bug at a time, ship when
|
|
||||||
test passes loosely." The right pattern for `1e-4` is the opposite:
|
|
||||||
**systematically diff every input field between mapped and hand-built,
|
|
||||||
fix every diff, then run the test once.** That's two more slices
|
|
||||||
(pumps_fans + window orientation) — not enough for a session of
|
|
||||||
incremental shipping, so consider doing both in one slice with the
|
|
||||||
pin as the forcing function.
|
|
||||||
|
|
||||||
You may also want to look harder at the *architectural* question:
|
|
||||||
why does Elmhurst's "site notes" (the surveyor's input form) need to
|
|
||||||
go through THREE schemas — `ElmhurstSiteNotes`, then `EpcPropertyData`,
|
|
||||||
then `CalculatorInputs` — when the hand-built fixture skips straight
|
|
||||||
to the middle one? The string→int translations in `from_elmhurst_site_notes`
|
|
||||||
are essentially doing what the extractor should do (or what an
|
|
||||||
`elmhurst_codes.py` codes-module could express). If `ElmhurstSiteNotes`
|
|
||||||
stored integer codes alongside the human-readable strings, the mapper
|
|
||||||
would be a pure projection.
|
|
||||||
|
|
||||||
## Quick-orient commands
|
|
||||||
|
|
||||||
```bash
|
```bash
|
||||||
# Failing test (Δ = 0.26 SAP → target < 1e-4)
|
# Probe all 6 fixtures' SAP delta
|
||||||
python -m pytest backend/documents_parser/tests/test_summary_pdf_mapper_chain.py::test_summary_000474_full_chain_sap_matches_worksheet_pdf_exactly --no-cov --no-header --tb=short
|
python /tmp/probe_all.py
|
||||||
|
|
||||||
# All Summary→chain tests (2/3 green, 1 failing — the one above)
|
# Dump raw extracted windows for a cert
|
||||||
python -m pytest backend/documents_parser/tests/test_summary_pdf_mapper_chain.py --no-cov --no-header -v
|
python /tmp/dump_one.py 000516
|
||||||
|
|
||||||
# Wider regression to confirm no fresh breakage
|
# Dump the §11 Windows section layout (debug extractor)
|
||||||
python -m pytest datatypes/epc/ backend/documents_parser/tests/ --no-cov --no-header -q
|
python /tmp/dump_section.py 000487
|
||||||
|
|
||||||
|
# Field-by-field input diff mapped vs handbuilt
|
||||||
|
python /tmp/diff_cert.py 000477
|
||||||
```
|
```
|
||||||
|
|
||||||
The 9 `test_appendix_u.py` failures and 1 `test_no_ac_cert_round_trips_fee_equals_space_heating_per_m2`
|
If `/tmp` got wiped, the contents are:
|
||||||
failure are **pre-existing** from before this session — don't try to
|
- `probe_all.py`: iterates 6 fixtures, mapper-cascades each, prints
|
||||||
fix them as part of this work.
|
Δ and BPs/windows counts.
|
||||||
|
- `dump_one.py <cert>`: prints raw `ElmhurstSiteNotes.windows` for
|
||||||
|
the given cert.
|
||||||
|
- `dump_section.py <cert>`: prints the line-by-line `§11 Windows`
|
||||||
|
section from the layout-preprocessed pages.
|
||||||
|
- `diff_cert.py <cert>`: cascades both mapped and handbuilt EPCs
|
||||||
|
through `cert_to_inputs`, diffs the scalar input fields.
|
||||||
|
|
||||||
|
## Suggested next slices
|
||||||
|
|
||||||
|
| Slice | Cert | Effort | Why next |
|
||||||
|
|---|---|---|---|
|
||||||
|
| 49 | 000477 | Medium | 1 BP topology → smallest moving parts; secondary-heating extraction unlocks the largest single fix |
|
||||||
|
| 50 | 000516 | Medium | Roof-window separation — adds new schema field, generalisable |
|
||||||
|
| 51 | 000487 | High | Extractor parser improvements (the §11 layout is uncovered terrain) |
|
||||||
|
| 52 | 000490 | Unknown | Diagnose then close |
|
||||||
|
| 53 | 000480 | Unknown | Largest Δ; do last after others reveal patterns |
|
||||||
|
|
||||||
|
## Definition of done (unchanged from before)
|
||||||
|
|
||||||
|
- All 6 `test_summary_pdf_mapper_chain.py` chain tests pin at 1e-4.
|
||||||
|
- Wider regression stays green (currently 754 pass).
|
||||||
|
- Pyright net-zero on every commit (strict mode).
|
||||||
|
- One slice = one commit.
|
||||||
|
- No widening, no xfail (project memory `feedback_zero_error_strict`).
|
||||||
|
|
||||||
## Reference materials
|
## Reference materials
|
||||||
|
|
||||||
- **`docs/sap-spec/HANDOVER_NEXT.md`** — original calculator-closure
|
- `docs/sap-spec/HANDOVER_NEXT.md` — original cascade-conventions handover.
|
||||||
handover; still useful as the canonical reference for cascade
|
- `docs/sap-spec/SAP_CALCULATOR.md` — public API + two-cascade architecture.
|
||||||
conventions (AAA tests, 1e-4 tolerance, etc.).
|
- Hand-built worksheet fixtures: `packages/domain/src/domain/sap/worksheet/tests/_elmhurst_worksheet_*.py` — the calculator-equivalent EpcPropertyData each mapped chain must reproduce.
|
||||||
- **`docs/sap-spec/SAP_CALCULATOR.md`** — public API + two-cascade
|
- Untracked source PDFs: `sap worksheets/` (`Summary_NNNNNN.pdf` + `U985-0001-NNNNNN.pdf` worksheets — the unrounded SAP target lives next to "SAP value" in the U985 PDF).
|
||||||
architecture (rating vs demand).
|
|
||||||
- **`sap worksheets/Summary_000474.pdf`** (untracked) — the source-of-
|
|
||||||
truth input for fixture 000474. Mirror tracked at
|
|
||||||
`backend/documents_parser/tests/fixtures/Summary_000474.pdf`.
|
|
||||||
- **`sap worksheets/U985-0001-000474.pdf`** (untracked) — the
|
|
||||||
Elmhurst-computed worksheet with line refs the test pins against
|
|
||||||
(line 257 for unrounded SAP).
|
|
||||||
- **`packages/domain/src/domain/sap/worksheet/tests/_elmhurst_worksheet_000474.py`**
|
|
||||||
— the hand-built `EpcPropertyData` for the same fixture. The CALCULATOR-
|
|
||||||
EQUIVALENT target the mapper must reproduce.
|
|
||||||
|
|
||||||
## File map for the work ahead
|
|
||||||
|
|
||||||
| File | Role |
|
|
||||||
|---|---|
|
|
||||||
| `backend/documents_parser/elmhurst_extractor.py` | PDF → `ElmhurstSiteNotes` extractor; layout-style window parser at `_compose_window_descriptors` is where diff #2 lives |
|
|
||||||
| `datatypes/epc/surveys/elmhurst_site_notes.py` | The schema (recently extended with `ExtensionPart`); `MainHeating` may need a `central_heating_pump_age` field for diff #1 |
|
|
||||||
| `datatypes/epc/domain/mapper.py:254-326` | `from_elmhurst_site_notes` — the mapper itself |
|
|
||||||
| `datatypes/epc/domain/mapper.py:1772-1830` | Code-translation helpers (`_leading_code`, `_elmhurst_wall_construction_int`, etc.) |
|
|
||||||
| `datatypes/epc/domain/mapper.py:2010-2080` | `_map_elmhurst_building_part` + extension iteration |
|
|
||||||
| `datatypes/epc/domain/mapper.py:2180+` | `_map_elmhurst_sap_heating` — likely where diff #1 (pumps_fans) is fixed |
|
|
||||||
| `packages/domain/src/domain/sap/rdsap/cert_to_inputs.py` | Cascade — search `pumps_fans_kwh_per_yr` for diff #1's root cause |
|
|
||||||
|
|
||||||
## Conventions you must honour (from project memory)
|
|
||||||
|
|
||||||
- AAA test convention: every new test uses literal `# Arrange / # Act
|
|
||||||
/ # Assert` headers
|
|
||||||
- `abs(diff) <= tol` not `pytest.approx` (strict pyright)
|
|
||||||
- One slice = one commit; stage by name (`?? non_invasive_photos/` and
|
|
||||||
similar untracked junk must not be staged)
|
|
||||||
- 1e-4 tolerance, no widening, no xfail (`feedback_zero_error_strict`)
|
|
||||||
- Strict pyright net-zero on every commit
|
|
||||||
|
|
||||||
## Branch state at handover
|
## Branch state at handover
|
||||||
|
|
||||||
```
|
```
|
||||||
$ git log --oneline -5
|
$ git log --oneline -7
|
||||||
256a5afe Slice 46c: Elmhurst mapper produces calculator-equivalent EpcPropertyData — Summary_000474 SAP within 0.5 of worksheet PDF
|
<this commit> Slice 48: Elmhurst extractor handles 5 new layout quirks; 5 fixture PDFs added
|
||||||
066dce19 Slice 46b: Elmhurst extractor parses windows from layout-style Summary PDFs
|
29ab80b0 Slice 47: Summary_000474 chain pins SAP at 1e-4 vs worksheet PDF
|
||||||
36f2c7bb Slice 46a: Elmhurst mapper handles multi-bp Summary PDFs — Summary_000474 chain test flips green
|
b6544e1c Handover: tighten Summary→SAP chain pin to 1e-4 + brief next agent
|
||||||
ccf7aa21 Scaffold: end-to-end Summary→EpcPropertyData chain test for 000474 (xfail)
|
256a5afe Slice 46c: Elmhurst mapper produces calculator-equivalent EpcPropertyData — Summary_000474 SAP within 0.5 of worksheet PDF
|
||||||
8ac548ca Audit: pin u_floor §5.12 formula cascade for cert 0240 cohort geometry
|
066dce19 Slice 46b: Elmhurst extractor parses windows from layout-style Summary PDFs
|
||||||
|
36f2c7bb Slice 46a: Elmhurst mapper handles multi-bp Summary PDFs — Summary_000474 chain test flips green
|
||||||
|
ccf7aa21 Scaffold: end-to-end Summary→EpcPropertyData chain test for 000474 (xfail)
|
||||||
```
|
```
|
||||||
|
|
||||||
The 0.5 tolerance in commit 46c's message is stale — this handover
|
|
||||||
tightened it to 1e-4 after the commit. The first thing you commit
|
|
||||||
should fix one of the two diffs and explicitly mention closing the
|
|
||||||
last bit of the gap toward 1e-4.
|
|
||||||
|
|
||||||
Good luck.
|
Good luck.
|
||||||
|
|
|
||||||
Loading…
Add table