fix(elmhurst): party-ceiling Main BP window is vertical, not a rooflight 🟩
_is_elmhurst_roof_window routed a vertical window (Location "External wall") to sap_roof_windows whenever its building part's roof type was a party ceiling (A "Another dwelling above" / NR "Non-residential space above"). That is right for an EXTENSION (cert 000565 Ext2/Ext4 score on worksheet (27a)) but wrong for the MAIN BP: a Main "A"/"NR" roof is the dwelling's own party ceiling — no external roof — so its windows are vertical. Gate the BP-roof-type rooflight rule to non-Main building parts. On a mid- floor flat (case 53 / cert 000565 re-keyed) the Main External-wall window is now vertical: its area deducts from the wall (was over-counted ~7 W/K) and it prices as a window. Summary-path SAP 74.0 -> 75.17, matching Elmhurst's accredited worksheet (75; space-heat 3408.6 vs 3408.58) — confirming the calculator is correct; the gap was the misclassification. 000565's extension rooflights, the "Roof of Room" branch, and the U>3.0 room-in-roof backstop are unchanged. gov-API path unaffected (it routes roof windows via window_wall_type==4). Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
parent
23245a085c
commit
0851b48807
1 changed files with 29 additions and 17 deletions
|
|
@ -6229,12 +6229,16 @@ def _elmhurst_orientation_int(orientation: str) -> int:
|
|||
# skylight per the worksheet's (27a) row.
|
||||
_ELMHURST_ROOF_WINDOW_U_THRESHOLD: Final[float] = 3.0
|
||||
|
||||
# RdSAP 10 §8.2 (PDF p.50) — BPs whose roof type is "Another dwelling
|
||||
# above" (A) or "Non-residential space above" (NR) have their own
|
||||
# external roof structure with potential rooflights, distinct from a
|
||||
# pitched-roof dwelling. Windows lodged against these BPs are routed
|
||||
# to `sap_roof_windows` regardless of their U-value.
|
||||
# Elmhurst §8 roof types that route an EXTENSION's window to a rooflight:
|
||||
# "A Another dwelling above" / "NR Non-residential space above". On an
|
||||
# extension BP these score on the worksheet (27a) Roof Windows line (cert
|
||||
# 000565 Ext2 [NR] + Ext4 [A]). NOT applied to the Main BP — a Main roof
|
||||
# of "A"/"NR" means the whole dwelling sits under another dwelling (a party
|
||||
# ceiling with no external roof), so its windows are vertical (simulated
|
||||
# case 53 / cert 000565 re-keyed as a mid-floor flat: Main roof "A",
|
||||
# External-wall window U 2.0 = vertical, Elmhurst Type "Window").
|
||||
_ELMHURST_BP_ROOF_TYPES_WITH_ROOFLIGHTS: Final[tuple[str, ...]] = ("A ", "NR ")
|
||||
_ELMHURST_MAIN_BUILDING_PARTS: Final[tuple[str, ...]] = ("Main", "Main Property")
|
||||
|
||||
|
||||
def _elmhurst_bp_roof_type(
|
||||
|
|
@ -6245,7 +6249,7 @@ def _elmhurst_bp_roof_type(
|
|||
Returns None when the BP isn't found (single-bp cert with no
|
||||
matching extension)."""
|
||||
bp = w.building_part
|
||||
if bp in ("Main", "Main Property"):
|
||||
if bp in _ELMHURST_MAIN_BUILDING_PARTS:
|
||||
return survey.roof.roof_type
|
||||
for ext in survey.extensions:
|
||||
if ext.name == bp:
|
||||
|
|
@ -6279,12 +6283,16 @@ def _is_elmhurst_roof_window(
|
|||
|
||||
1. Single-glazed windows are never rooflights — Part L 2006
|
||||
minimum glazing for any rooflight is double-glazed.
|
||||
2. BP roof type ∈ {A, NR} → rooflight — the BP has its own
|
||||
external roof structure with rooflights (worksheet (30)
|
||||
External roof + (27a) Roof Windows treatment).
|
||||
3. U > 3.0 W/m²K → rooflight — cohort backstop catching old
|
||||
skylights on pitched roofs (cohort cert 000516 W6).
|
||||
4. Otherwise vertical.
|
||||
2. Explicit "Roof of Room" location → rooflight.
|
||||
3. EXTENSION BP roof type ∈ {A, NR} → rooflight (worksheet (30)
|
||||
External roof + (27a) Roof Windows treatment). EXCLUDES the Main
|
||||
BP: a Main roof of "A"/"NR" is a party ceiling (whole dwelling
|
||||
under another dwelling), so its windows are vertical — simulated
|
||||
case 53 / cert 000565 mid-floor flat (Main roof "A", External-wall
|
||||
window U 2.0, Elmhurst Type "Window").
|
||||
4. U > 3.0 W/m²K AND the BP has a room-in-roof → rooflight — cohort
|
||||
backstop catching old skylights on a sloping ceiling (cert 000516 W6).
|
||||
5. Otherwise vertical.
|
||||
"""
|
||||
if w.glazing_type.startswith("Single"):
|
||||
return False
|
||||
|
|
@ -6293,11 +6301,15 @@ def _is_elmhurst_roof_window(
|
|||
# regardless of BP roof type or U-value.
|
||||
if "roof of room" in (w.location or "").lower():
|
||||
return True
|
||||
bp_roof_type = _elmhurst_bp_roof_type(w, survey)
|
||||
if bp_roof_type is not None and bp_roof_type.startswith(
|
||||
_ELMHURST_BP_ROOF_TYPES_WITH_ROOFLIGHTS
|
||||
):
|
||||
return True
|
||||
# EXTENSION BP whose roof type is a party ceiling (A / NR) scores its
|
||||
# windows on (27a) — but never the Main BP (a Main "A"/"NR" roof is the
|
||||
# dwelling's own party ceiling; case 53).
|
||||
if w.building_part not in _ELMHURST_MAIN_BUILDING_PARTS:
|
||||
bp_roof_type = _elmhurst_bp_roof_type(w, survey)
|
||||
if bp_roof_type is not None and bp_roof_type.startswith(
|
||||
_ELMHURST_BP_ROOF_TYPES_WITH_ROOFLIGHTS
|
||||
):
|
||||
return True
|
||||
# U > 3.0 backstop, gated on the BP having a room-in-roof. Elmhurst routes a
|
||||
# high-U "Double pre 2002" unit through the worksheet's (27a) Roof Windows
|
||||
# line regardless of its lodged "External wall" location — but ONLY where the
|
||||
|
|
|
|||