@ -337,7 +337,7 @@ class RoofRecommendations:
|
|||
if proposed_depth >= 300:
|
||||
new_efficiency = "Very Good"
|
||||
else:
|
||||
if self.property.data["walls-energy-eff"] not in ["Good", "Very Good"]:
|
||||
if self.property.data["roof-energy-eff"] not in ["Good", "Very Good"]:
|
||||
new_efficiency = "Good"
|
||||
else:
|
||||
new_efficiency = "Very Good"
|
||||
|
|
|
|||
|
|
@ -39,15 +39,8 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 10.0, 'low-energy-fixed-light-count': 7.0, 'uprn': 100110195416.0,
|
||||
'uprn-source': 'Address Matched'
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
"Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and "
|
||||
"smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade "
|
||||
"scheme grant",
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [
|
||||
"Upgrade heating controls to Smart Thermostats, room sensors and smart radiator valves (time & "
|
||||
"temperature zone control)"
|
||||
],
|
||||
"heating_measure_types": ["air_source_heat_pump"],
|
||||
"heating_controls_measure_types": ["time_temperature_zone_control"],
|
||||
"notes": "This property has a boiler, radiators & mains gas with good efficiency so the only recommendation"
|
||||
"we expect here is for an air source heat pump. The heating controls are a programmer, room thermostat"
|
||||
"and TRVs and so we should expect a TTZC recommendation"
|
||||
|
|
@ -93,11 +86,10 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 10012342725.0,
|
||||
'uprn-source': 'Address Matched',
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
"Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention "
|
||||
"Storage Heater Controls"
|
||||
"heating_measure_types": [
|
||||
"high_heat_retention_storage_heater",
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has electric room heaters and is off gas so a boiler recommendation is not appropriate."
|
||||
"We would expect a high heat retention storage recommendation. The property is a flat and therefore"
|
||||
"we don't expect an air source heat pump recommendation. We also wouldn't expect a specific heating"
|
||||
|
|
@ -144,16 +136,8 @@ testing_examples = [
|
|||
'tenure': 'owner-occupied', 'fixed-lighting-outlets-count': 6.0, 'low-energy-fixed-light-count': 4.0,
|
||||
'uprn': 100090311351.0, 'uprn-source': 'Address Matched', 'property-type_y': None, 'built-form_y': None,
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install high heat retention electric storage heaters. The current electric heaters may be retrofit with '
|
||||
'high heat retention storage controls however this is dependent on the existing system and may not be '
|
||||
'possible. Upgrade heating controls to High Heat Retention Storage Heater Controls',
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant'
|
||||
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_measure_types": ['high_heat_retention_storage_heater', 'air_source_heat_pump'],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This test has electric storage heaters with automatic charge control - we recommend hhr storage"
|
||||
"heaters in this case, but because there are already electic storage heaters in place, we "
|
||||
"note, in the description of the recommendation, that this upgrade may be possible by retrofitting"
|
||||
|
|
@ -197,13 +181,10 @@ testing_examples = [
|
|||
'tenure': 'owner-occupied', 'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None,
|
||||
'uprn': 100021560521.0, 'uprn-source': 'Address Matched',
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler.'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [
|
||||
'Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade heating controls to Smart Thermostats, room sensors and smart radiator valves (time & '
|
||||
'temperature zone control)'
|
||||
"heating_measure_types": ['boiler_upgrade'],
|
||||
"heating_controls_measure_types": [
|
||||
'roomstat_programmer_trvs',
|
||||
'time_temperature_zone_control',
|
||||
],
|
||||
"notes": "Because of this property is a maisonette, which already has a boiler (but an inefficient one due to "
|
||||
"the current water heating efficiency) the only recommendation we expect is for "
|
||||
|
|
@ -250,12 +231,10 @@ testing_examples = [
|
|||
'tenure': 'owner-occupied', 'fixed-lighting-outlets-count': 9.0, 'low-energy-fixed-light-count': 5.0,
|
||||
'uprn': 100021936225.0, 'uprn-source': 'Address Matched',
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [
|
||||
'Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade heating controls to Smart Thermostats, room sensors and smart radiator valves (time & '
|
||||
'temperature zone control)'
|
||||
"heating_measure_types": [],
|
||||
"heating_controls_measure_types": [
|
||||
'roomstat_programmer_trvs',
|
||||
'time_temperature_zone_control',
|
||||
],
|
||||
"notes": "Because this property already has a boiler, we don't recommend HHR. We don't recommend an ashp "
|
||||
"because the home is mid-terraced. Because the heating controls are "
|
||||
|
|
@ -302,11 +281,10 @@ testing_examples = [
|
|||
'tenure': 'rental (private)', 'fixed-lighting-outlets-count': 7.0, 'low-energy-fixed-light-count': 6.0,
|
||||
'uprn': 43088770.0, 'uprn-source': 'Address Matched',
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property is a flat so we don't have an ASHP recommendation. It also doesn't have access to the "
|
||||
"mains and so it can't have a gas boiler. We don't expect any controls recommendations"
|
||||
},
|
||||
|
|
@ -348,16 +326,10 @@ testing_examples = [
|
|||
'tenure': 'owner-occupied', 'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None,
|
||||
'uprn': 100080513604.0, 'uprn-source': 'Address Matched'
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [
|
||||
'Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade heating controls to Smart Thermostats, room sensors and smart radiator valves (time & '
|
||||
'temperature zone control)'
|
||||
|
||||
"heating_measure_types": ['air_source_heat_pump'],
|
||||
"heating_controls_measure_types": [
|
||||
'roomstat_programmer_trvs',
|
||||
'time_temperature_zone_control',
|
||||
],
|
||||
"notes": "This has a very efficient boiler and is a detached bungalow, but only has "
|
||||
"Programmer and room thermostat for heating controls so we'd expect an ASHP heating recommendation"
|
||||
|
|
@ -404,14 +376,12 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 10.0, 'low-energy-fixed-light-count': 9.0, 'uprn': 100070358594,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and smart '
|
||||
'radiator valves (time & temperature zone control)'
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater',
|
||||
'boiler_upgrade'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has assumed electric heating and is mid-terrace house. It has a mains gas connection."
|
||||
"We can recommend a boiler upgrade and high heat retention storage heaters"
|
||||
},
|
||||
|
|
@ -453,15 +423,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 42.0, 'low-energy-fixed-light-count': 13.0, 'uprn': 100070985545,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has an oil boiler and doesn't have a mains gas connection so we can only recommend"
|
||||
"an air source heat pump and HHR (since if the home has a non-gas boiler, we recommend HHR)"
|
||||
},
|
||||
|
|
@ -505,17 +471,13 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 2465031849,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls',
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control)'
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater',
|
||||
'air_source_heat_pump',
|
||||
'boiler_upgrade' # TTZs
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has room heaters, from the mains gas supply. We recommend a boiler upgrade as"
|
||||
"well as an air source heat pump and HHR (since the home has a room heater set up)"
|
||||
},
|
||||
|
|
@ -558,14 +520,12 @@ testing_examples = [
|
|||
'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and smart '
|
||||
'radiator valves (time & temperature zone control)',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls',
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has assumed electric heaters. Boiler upgrade, HHR are recommended. We don't recommend"
|
||||
"an ASHP off of the bat because it's mid-terrace."
|
||||
},
|
||||
|
|
@ -607,14 +567,12 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 10.0, 'low-energy-fixed-light-count': None, 'uprn': 100071089116,
|
||||
'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control)'
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater',
|
||||
'boiler_upgrade'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This has a form of assumed electric heating and has a mains connection so we recommend HHR, boiler"
|
||||
"upgrade and ASHP"
|
||||
},
|
||||
|
|
@ -657,15 +615,12 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 100030352255,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and smart '
|
||||
'radiator valves (time & temperature zone control)',
|
||||
'Install high heat retention electric storage heaters. The current electric heaters may be retrofit with '
|
||||
'high heat retention storage controls however this is dependent on the existing system and may not be '
|
||||
'possible. Upgrade heating controls to High Heat Retention Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property already has storage heaters with manual charge control. The home is mid terrace so"
|
||||
"the ashp is not suitable"
|
||||
},
|
||||
|
|
@ -709,14 +664,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 10009573249,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls',
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant'
|
||||
"heating_measure_types": [
|
||||
'high_heat_retention_storage_heater',
|
||||
'air_source_heat_pump',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has an LFG boiler but it doesn't have a mains gas connection so we can only recommend"
|
||||
"an air source heat pump and hhr storage"
|
||||
},
|
||||
|
|
@ -758,14 +710,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 8.0, 'low-energy-fixed-light-count': None, 'uprn': 10013181470,
|
||||
'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls',
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant'
|
||||
"heating_measure_types": [
|
||||
'high_heat_retention_storage_heater',
|
||||
'air_source_heat_pump',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has electric boilers in place, but does not have a mains connection so we don't "
|
||||
"recommend a boiler upgrade. We recommend HHR and ASHP"
|
||||
},
|
||||
|
|
@ -809,14 +758,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 11.0, 'low-energy-fixed-light-count': 7.0, 'uprn': 452047507,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has a dual fuel boiler and no mains gas connection. We recommend ASHP and HHR, but"
|
||||
"no gas condensing boiler"
|
||||
},
|
||||
|
|
@ -857,14 +803,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 16.0, 'low-energy-fixed-light-count': 4.0, 'uprn': 100030309413,
|
||||
'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has a coal boiler and no mains gas connection. We recommend ASHP and HHR, but"
|
||||
"no gas condensing boiler"
|
||||
},
|
||||
|
|
@ -908,15 +851,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 10007366417,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has a smokeless fuel boiler and no mains gas connection. We recommend ASHP and HHR, but"
|
||||
"no gas condensing boiler"
|
||||
},
|
||||
|
|
@ -958,15 +897,11 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 100030256931,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has a wood pellets boiler and no mains gas connection. We recommend ASHP and HHR, but"
|
||||
"no gas condensing boiler"
|
||||
},
|
||||
|
|
@ -1009,11 +944,10 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 10000460605,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'high_heat_retention_storage_heater',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This is an end-terrace house, without mains gas connection, so all we recommend is HHR"
|
||||
},
|
||||
{
|
||||
|
|
@ -1054,8 +988,8 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 100031045596,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_measure_types": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property already has an ashp. We don't recommend any heating upgrades"
|
||||
},
|
||||
{
|
||||
|
|
@ -1095,17 +1029,12 @@ testing_examples = [
|
|||
'tenure': 'Rented (social)', 'fixed-lighting-outlets-count': 11.0, 'low-energy-fixed-light-count': None,
|
||||
'uprn': 90041166, 'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters alongside the boiler. The current electric heaters '
|
||||
'may be retrofit with high heat retention storage controls however this is dependent on the existing '
|
||||
'system and may not be possible. Upgrade heating controls to High Heat Retention Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [
|
||||
'Upgrade heating controls to Smart Thermostats, room sensors and smart radiator valves (time & '
|
||||
'temperature zone control)'
|
||||
"heating_controls_measure_types": [
|
||||
'time_temperature_zone_control',
|
||||
],
|
||||
"notes": "This property has dual heating. A boiler and electric storage heaters. The heating is efficient so"
|
||||
"we recommend ASHP and HHR. We also recommend upgrading the heating controls for the boiler"
|
||||
|
|
@ -1147,20 +1076,14 @@ testing_examples = [
|
|||
'tenure': 'Rented (social)', 'fixed-lighting-outlets-count': 11.0, 'low-energy-fixed-light-count': None,
|
||||
'uprn': 90041166, 'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Upgrade the existing boiler to a new, more efficient condensing boiler. ',
|
||||
'Upgrade both the existing boiler to a new condensing boiler and upgrade storage heaters to high heat '
|
||||
'retention storage heaters.',
|
||||
'Install high heat retention electric storage heaters alongside the boiler. The current electric heaters '
|
||||
'may be retrofit with high heat retention storage controls however this is dependent on the existing '
|
||||
'system and may not be possible. Upgrade heating controls to High Heat Retention Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'boiler_upgrade',
|
||||
'boiler_upgrade+high_heat_retention_storage_heater',
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [
|
||||
'Upgrade heating controls to Smart Thermostats, room sensors and smart radiator valves (time & '
|
||||
'temperature zone control)'
|
||||
"heating_controls_measure_types": [
|
||||
'time_temperature_zone_control'
|
||||
],
|
||||
"notes": "This property is a modified version of the previous dual heating property, where we lower the"
|
||||
"starting heating efficiency so that we a combined heating upgrade to both the boiler and the electric"
|
||||
|
|
@ -1204,14 +1127,11 @@ testing_examples = [
|
|||
'tenure': 'rental (social)', 'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None,
|
||||
'uprn': 10009574286, 'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has anthracite heating without mains. "
|
||||
"We recommend ASHP and HHR, but no gas condensing boiler"
|
||||
},
|
||||
|
|
@ -1254,14 +1174,12 @@ testing_examples = [
|
|||
'fixed-lighting-outlets-count': 8.0, 'low-energy-fixed-light-count': None, 'uprn': 100031556691,
|
||||
'uprn-source': 'Energy Assessor', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and smart '
|
||||
'radiator valves (time & temperature zone control)',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has room heaters with two different fuel sources, so we recommend HHR, ASHP, and a "
|
||||
"boiler upgrade"
|
||||
},
|
||||
|
|
@ -1302,11 +1220,10 @@ testing_examples = [
|
|||
'uprn': 100070685908, 'uprn-source': 'Address Matched', 'sheating-energy-eff': None,
|
||||
'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property is a flag, without mains gas connection. Currently has underfloor electric heating"
|
||||
"so we recommend HHR"
|
||||
},
|
||||
|
|
@ -1348,17 +1265,13 @@ testing_examples = [
|
|||
'uprn': 100071209105, 'uprn-source': 'Address Matched', 'sheating-energy-eff': None,
|
||||
'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Install an air source heat pump, and upgrade heating controls to Smart Thermostats, room sensors and '
|
||||
'smart radiator valves (time & temperature zone control). The cost includes the £7500 boiler upgrade '
|
||||
'scheme grant',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and smart '
|
||||
'radiator valves (time & temperature zone control)',
|
||||
'Install high heat retention electric storage heaters. Upgrade heating controls to High Heat Retention '
|
||||
'Storage Heater Controls'
|
||||
"heating_measure_types": [
|
||||
'air_source_heat_pump',
|
||||
'boiler_upgrade',
|
||||
'boiler_upgrade',
|
||||
'high_heat_retention_storage_heater'
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "The property has warm air electricaire heating, so we recommend ASHP and HHR. It also has a mains"
|
||||
"connection so we recommend a gas condensing boiler"
|
||||
},
|
||||
|
|
@ -1402,12 +1315,11 @@ testing_examples = [
|
|||
'uprn': 100070955137, 'uprn-source': 'Address Matched', 'sheating-energy-eff': None,
|
||||
'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Room thermostat, programmer and TRVs',
|
||||
'Upgrade to a new condensing boiler. Upgrade heating controls to Smart Thermostats, room sensors and smart '
|
||||
'radiator valves (time & temperature zone control)'
|
||||
"heating_measure_types": [
|
||||
'boiler_upgrade',
|
||||
'boiler_upgrade',
|
||||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"heating_controls_measure_types": [],
|
||||
"notes": "This property has warm air mains gas heating, so we recommend a gas condensing boiler"
|
||||
}
|
||||
]
|
||||
|
|
|
|||
|
|
@ -96,19 +96,19 @@ class TestHeatingRecommendations:
|
|||
|
||||
recommender.recommend(has_cavity_or_loft_recommendations=False)
|
||||
|
||||
assert len(recommender.heating_recommendations) == len(test_case["heating_recommendation_descriptions"])
|
||||
assert len(recommender.heating_recommendations) == len(test_case["heating_measure_types"])
|
||||
assert (
|
||||
len(recommender.heating_control_recommendations) ==
|
||||
len(test_case["heating_controls_recommendation_descriptions"])
|
||||
len(test_case["heating_controls_measure_types"])
|
||||
)
|
||||
|
||||
# Check the exact descriptions
|
||||
# Check the exact measure types
|
||||
assert (
|
||||
{x["description"] for x in recommender.heating_recommendations} ==
|
||||
set(test_case["heating_recommendation_descriptions"])
|
||||
{x["measure_type"] for x in recommender.heating_recommendations} ==
|
||||
set(test_case["heating_measure_types"])
|
||||
)
|
||||
|
||||
assert (
|
||||
{x["description"] for x in recommender.heating_control_recommendations} ==
|
||||
set(test_case["heating_controls_recommendation_descriptions"])
|
||||
{x["measure_type"] for x in recommender.heating_control_recommendations} ==
|
||||
set(test_case["heating_controls_measure_types"])
|
||||
)
|
||||
|
|
|
|||
|
|
@ -35,7 +35,7 @@ class TestRoofRecommendations:
|
|||
|
||||
def test_loft_insulation_recommendation_50mm_insulation(self):
|
||||
epc_record = EPCRecord()
|
||||
epc_record.prepared_epc = {"county": "Kent"}
|
||||
epc_record.prepared_epc = {"county": "Kent", "roof-energy-eff": "Very Poor"}
|
||||
property_instance2 = Property(id=0, address="fake", postcode="fake", epc_record=epc_record)
|
||||
property_instance2.age_band = "F"
|
||||
property_instance2.insulation_floor_area = 100
|
||||
|
|
@ -63,7 +63,7 @@ class TestRoofRecommendations:
|
|||
assert roof_recommender2.recommendations[0]["parts"][0]["depth"] == 270
|
||||
|
||||
epc_record = EPCRecord()
|
||||
epc_record.prepared_epc = {"county": "Greater London Authority"}
|
||||
epc_record.prepared_epc = {"county": "Greater London Authority", "roof-energy-eff": "Very Poor"}
|
||||
property_instance3 = Property(id=0, address="fake", postcode="fake", epc_record=epc_record)
|
||||
property_instance3.age_band = "F"
|
||||
property_instance3.insulation_floor_area = 100
|
||||
|
|
@ -89,7 +89,7 @@ class TestRoofRecommendations:
|
|||
|
||||
def test_loft_insulation_recommendation_150mm_insulation(self):
|
||||
epc_record = EPCRecord()
|
||||
epc_record.prepared_epc = {"county": "North East Lincolnshire"}
|
||||
epc_record.prepared_epc = {"county": "North East Lincolnshire", "roof-energy-eff": "Good"}
|
||||
property_instance4 = Property(id=0, address="fake", postcode="fake", epc_record=epc_record)
|
||||
property_instance4.age_band = "F"
|
||||
property_instance4.insulation_floor_area = 100
|
||||
|
|
@ -117,7 +117,7 @@ class TestRoofRecommendations:
|
|||
assert roof_recommender4.recommendations[0]["parts"][0]["depth"] == 200
|
||||
|
||||
epc_record = EPCRecord()
|
||||
epc_record.prepared_epc = {"county": "Somerset"}
|
||||
epc_record.prepared_epc = {"county": "Somerset", "roof-energy-eff": "Good"}
|
||||
property_instance5 = Property(id=0, address="fake", postcode="fake", epc_record=epc_record)
|
||||
property_instance5.age_band = "F"
|
||||
property_instance5.insulation_floor_area = 100
|
||||
|
|
@ -189,8 +189,8 @@ class TestRoofRecommendations:
|
|||
roof_recommender7.recommend(phase=0)
|
||||
|
||||
assert len(roof_recommender7.recommendations) == 1
|
||||
assert roof_recommender7.recommendations[0]["new_u_value"] == 0.23
|
||||
assert roof_recommender7.recommendations[0]["starting_u_value"] == 1.5
|
||||
assert roof_recommender7.recommendations[0]["new_u_value"] == 0.24
|
||||
assert roof_recommender7.recommendations[0]["starting_u_value"] == 2.3
|
||||
assert roof_recommender7.recommendations[0]["description"] == "Insulate room in roof at rafters and re-decorate"
|
||||
|
||||
def test_ceiling_insulated_room_in_roof(self):
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue