mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-07-12 13:29:04 +00:00
test(accuracy): validate + pin 100061275133 (slice-5 external-insulation U confirmed)
2-storey semi, solid brick 400mm with EXTERNAL insulation, 300mm loft, suspended uninsulated ground floor, gas combi, double glazing (glazed_type 13). Built in accredited Elmhurst RdSAP10: roof (U 0.14, 5.459 W/K) and windows (15.32 x eff U 1.3258 = 20.311 W/K) match the engine EXACTLY; the externally-insulated wall is engine U 0.29 vs Elmhurst 0.30, validating the slice-5 external-insulation default (100mm added over solid brick); suspended ground floor engine 0.68 vs Elmhurst 0.70. Elmhurst's overall SAP 67 is not comparable (reused-assessment Standard-Combi keep-hot loss, a build artifact). Engine 77 vs lodged 76 (within 1.24). Pinned to the observed 77. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
parent
17ced10e94
commit
1032a4f128
5 changed files with 656 additions and 0 deletions
Binary file not shown.
Binary file not shown.
|
|
@ -0,0 +1,410 @@
|
|||
{
|
||||
"uprn": 100061275133,
|
||||
"roofs": [
|
||||
{
|
||||
"description": "Pitched, 300 mm loft insulation",
|
||||
"energy_efficiency_rating": 5,
|
||||
"environmental_efficiency_rating": 5
|
||||
}
|
||||
],
|
||||
"walls": [
|
||||
{
|
||||
"description": "Solid brick, with external insulation",
|
||||
"energy_efficiency_rating": 4,
|
||||
"environmental_efficiency_rating": 4
|
||||
}
|
||||
],
|
||||
"floors": [
|
||||
{
|
||||
"description": "Suspended, no insulation (assumed)",
|
||||
"energy_efficiency_rating": 0,
|
||||
"environmental_efficiency_rating": 0
|
||||
}
|
||||
],
|
||||
"status": "entered",
|
||||
"tenure": 2,
|
||||
"window": {
|
||||
"description": "High performance glazing",
|
||||
"energy_efficiency_rating": 4,
|
||||
"environmental_efficiency_rating": 4
|
||||
},
|
||||
"lighting": {
|
||||
"description": "Excellent lighting efficiency",
|
||||
"energy_efficiency_rating": 5,
|
||||
"environmental_efficiency_rating": 5
|
||||
},
|
||||
"postcode": "ME7 2ES",
|
||||
"hot_water": {
|
||||
"description": "From main system",
|
||||
"energy_efficiency_rating": 4,
|
||||
"environmental_efficiency_rating": 4
|
||||
},
|
||||
"post_town": "GILLINGHAM",
|
||||
"built_form": 2,
|
||||
"created_at": "2026-05-20 08:39:48",
|
||||
"door_count": 2,
|
||||
"region_code": 14,
|
||||
"report_type": 2,
|
||||
"sap_heating": {
|
||||
"number_baths": 1,
|
||||
"cylinder_size": 1,
|
||||
"number_baths_wwhrs": 0,
|
||||
"water_heating_code": 901,
|
||||
"water_heating_fuel": 26,
|
||||
"main_heating_details": [
|
||||
{
|
||||
"has_fghrs": "N",
|
||||
"main_fuel_type": 26,
|
||||
"boiler_flue_type": 2,
|
||||
"fan_flue_present": "Y",
|
||||
"heat_emitter_type": 1,
|
||||
"emitter_temperature": 0,
|
||||
"main_heating_number": 1,
|
||||
"main_heating_control": 2106,
|
||||
"main_heating_category": 2,
|
||||
"main_heating_fraction": 1,
|
||||
"central_heating_pump_age": 0,
|
||||
"main_heating_data_source": 1,
|
||||
"main_heating_index_number": 18908
|
||||
}
|
||||
],
|
||||
"immersion_heating_type": "NA",
|
||||
"has_fixed_air_conditioning": "false"
|
||||
},
|
||||
"sap_version": 10.2,
|
||||
"sap_windows": [
|
||||
{
|
||||
"orientation": 8,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.19,
|
||||
"window_height": 1.13,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 8,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 0.57,
|
||||
"window_height": 0.55,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 8,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.19,
|
||||
"window_height": 1.11,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 2,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.05,
|
||||
"window_height": 0.85,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 2,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 0.57,
|
||||
"window_height": 0.56,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 4,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 2.11,
|
||||
"window_height": 1.13,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 4,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.8,
|
||||
"window_height": 0.97,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 4,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.8,
|
||||
"window_height": 0.97,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 4,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.2,
|
||||
"window_height": 0.99,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 8,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.8,
|
||||
"window_height": 0.97,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 8,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.19,
|
||||
"window_height": 0.97,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
},
|
||||
{
|
||||
"orientation": 8,
|
||||
"window_type": 1,
|
||||
"glazing_type": 13,
|
||||
"window_width": 1.18,
|
||||
"window_height": 0.99,
|
||||
"draught_proofed": "true",
|
||||
"window_location": 0,
|
||||
"window_wall_type": 1,
|
||||
"permanent_shutters_present": "N",
|
||||
"permanent_shutters_insulated": "N"
|
||||
}
|
||||
],
|
||||
"schema_type": "RdSAP-Schema-21.0.1",
|
||||
"uprn_source": "Energy Assessor",
|
||||
"country_code": "ENG",
|
||||
"main_heating": [
|
||||
{
|
||||
"description": "Boiler and radiators, mains gas",
|
||||
"energy_efficiency_rating": 4,
|
||||
"environmental_efficiency_rating": 4
|
||||
}
|
||||
],
|
||||
"air_tightness": {
|
||||
"description": "(not tested)",
|
||||
"energy_efficiency_rating": 0,
|
||||
"environmental_efficiency_rating": 0
|
||||
},
|
||||
"dwelling_type": "Semi-detached house",
|
||||
"language_code": 1,
|
||||
"pressure_test": 4,
|
||||
"property_type": 0,
|
||||
"address_line_1": "75 Toronto Road",
|
||||
"assessment_type": "RdSAP",
|
||||
"completion_date": "2026-05-20",
|
||||
"inspection_date": "2026-05-19",
|
||||
"extensions_count": 0,
|
||||
"measurement_type": 1,
|
||||
"total_floor_area": 78,
|
||||
"transaction_type": 8,
|
||||
"conservatory_type": 1,
|
||||
"heated_room_count": 3,
|
||||
"registration_date": "2026-05-20",
|
||||
"sap_energy_source": {
|
||||
"mains_gas": "Y",
|
||||
"meter_type": 2,
|
||||
"pv_connection": 0,
|
||||
"photovoltaic_supply": {
|
||||
"none_or_no_details": {
|
||||
"percent_roof_area": 0
|
||||
}
|
||||
},
|
||||
"wind_turbines_count": 0,
|
||||
"gas_smart_meter_present": "true",
|
||||
"is_dwelling_export_capable": "false",
|
||||
"wind_turbines_terrain_type": 2,
|
||||
"electricity_smart_meter_present": "true"
|
||||
},
|
||||
"secondary_heating": {
|
||||
"description": "None",
|
||||
"energy_efficiency_rating": 0,
|
||||
"environmental_efficiency_rating": 0
|
||||
},
|
||||
"sap_building_parts": [
|
||||
{
|
||||
"identifier": "Main Dwelling",
|
||||
"wall_dry_lined": "N",
|
||||
"wall_thickness": 400,
|
||||
"floor_heat_loss": 7,
|
||||
"roof_construction": 4,
|
||||
"wall_construction": 3,
|
||||
"building_part_number": 1,
|
||||
"sap_floor_dimensions": [
|
||||
{
|
||||
"floor": 0,
|
||||
"room_height": {
|
||||
"value": 2.4,
|
||||
"quantity": "metres"
|
||||
},
|
||||
"floor_insulation": 1,
|
||||
"total_floor_area": {
|
||||
"value": 38.99,
|
||||
"quantity": "square metres"
|
||||
},
|
||||
"party_wall_length": {
|
||||
"value": 5.09,
|
||||
"quantity": "metres"
|
||||
},
|
||||
"floor_construction": 0,
|
||||
"heat_loss_perimeter": {
|
||||
"value": 17.92,
|
||||
"quantity": "metres"
|
||||
}
|
||||
},
|
||||
{
|
||||
"floor": 1,
|
||||
"room_height": {
|
||||
"value": 2.4,
|
||||
"quantity": "metres"
|
||||
},
|
||||
"total_floor_area": {
|
||||
"value": 38.99,
|
||||
"quantity": "square metres"
|
||||
},
|
||||
"party_wall_length": {
|
||||
"value": 5.09,
|
||||
"quantity": "metres"
|
||||
},
|
||||
"heat_loss_perimeter": {
|
||||
"value": 17.92,
|
||||
"quantity": "metres"
|
||||
}
|
||||
}
|
||||
],
|
||||
"wall_insulation_type": 1,
|
||||
"construction_age_band": "B",
|
||||
"party_wall_construction": 1,
|
||||
"wall_thickness_measured": "Y",
|
||||
"roof_insulation_location": 2,
|
||||
"roof_insulation_thickness": "300mm",
|
||||
"wall_insulation_thickness": "100mm",
|
||||
"floor_insulation_thickness": "NI"
|
||||
}
|
||||
],
|
||||
"solar_water_heating": "N",
|
||||
"habitable_room_count": 3,
|
||||
"heating_cost_current": {
|
||||
"value": 608,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"insulated_door_count": 0,
|
||||
"co2_emissions_current": 1.9,
|
||||
"energy_rating_average": 60,
|
||||
"energy_rating_current": 76,
|
||||
"lighting_cost_current": {
|
||||
"value": 58,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"main_heating_controls": [
|
||||
{
|
||||
"description": "Programmer, room thermostat and TRVs",
|
||||
"energy_efficiency_rating": 4,
|
||||
"environmental_efficiency_rating": 4
|
||||
}
|
||||
],
|
||||
"has_hot_water_cylinder": "false",
|
||||
"heating_cost_potential": {
|
||||
"value": 608,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"hot_water_cost_current": {
|
||||
"value": 182,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"mechanical_ventilation": 0,
|
||||
"percent_draughtproofed": 100,
|
||||
"suggested_improvements": [
|
||||
{
|
||||
"sequence": 1,
|
||||
"typical_saving": {
|
||||
"value": 216,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"indicative_cost": "\u00a38,000 - \u00a310,000",
|
||||
"improvement_type": "U",
|
||||
"improvement_details": {
|
||||
"improvement_number": 34
|
||||
},
|
||||
"improvement_category": 5,
|
||||
"energy_performance_rating": 81,
|
||||
"environmental_impact_rating": 79
|
||||
}
|
||||
],
|
||||
"co2_emissions_potential": 1.8,
|
||||
"energy_rating_potential": 81,
|
||||
"lighting_cost_potential": {
|
||||
"value": 58,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"schema_version_original": "21.0.1",
|
||||
"hot_water_cost_potential": {
|
||||
"value": 182,
|
||||
"currency": "GBP"
|
||||
},
|
||||
"renewable_heat_incentive": {
|
||||
"water_heating": 2203.16,
|
||||
"space_heating_existing_dwelling": 5517.85
|
||||
},
|
||||
"draughtproofed_door_count": 2,
|
||||
"energy_consumption_current": 133,
|
||||
"has_fixed_air_conditioning": "false",
|
||||
"multiple_glazed_proportion": 100,
|
||||
"calculation_software_version": "5.02r0344",
|
||||
"energy_consumption_potential": 118,
|
||||
"environmental_impact_current": 78,
|
||||
"current_energy_efficiency_band": "C",
|
||||
"environmental_impact_potential": 79,
|
||||
"led_fixed_lighting_bulbs_count": 5,
|
||||
"has_heated_separate_conservatory": "false",
|
||||
"potential_energy_efficiency_band": "B",
|
||||
"co2_emissions_current_per_floor_area": 24,
|
||||
"incandescent_fixed_lighting_bulbs_count": 0
|
||||
}
|
||||
224
scripts/hyde/build_100061275133.py
Normal file
224
scripts/hyde/build_100061275133.py
Normal file
|
|
@ -0,0 +1,224 @@
|
|||
"""Elmhurst build for UPRN 100061275133 (RdSAP-21.0.1, MID-TERRACE HOUSE, band B,
|
||||
SOLID BRICK 250 mm uninsulated, pitched insulated (assumed) loft, floor to
|
||||
UNHEATED space, mains-gas COMBI (PCDB 19008) + gas room-heater SECONDARY, DUAL
|
||||
meter, 11 DG windows ~18.32 m², TFA 116. Lodged SAP 63; engine 65.0 (Δ +2.0).
|
||||
|
||||
Per-cert Elmhurst validation. Uses set_single_window (deletes the shared
|
||||
assessment's carried-over window rows) + reset_transient_state at the end so the
|
||||
assessment is left neutral. Run:
|
||||
DISPLAY=:99 python scripts/hyde/build_100061275133.py <page>
|
||||
"""
|
||||
from __future__ import annotations
|
||||
import sys
|
||||
from pathlib import Path
|
||||
import elmhurst_lib as E
|
||||
|
||||
DIM = "TabContainer_TabPanelMain_WebUserControlDimensionsMain_"
|
||||
WALL = ("TabContainer_TabPanelMain_InnerTabContainerMain_"
|
||||
"TabPanelExternalWallMain_WebUserControlWallMain_")
|
||||
PWALL = ("TabContainer_TabPanelMain_InnerTabContainerMain_"
|
||||
"TabPanelPartyWallMain_WebUserControlPartyWallMain_")
|
||||
ROOF = "TabContainer_TabPanelMain_WebUserControlRoofMain_"
|
||||
FLOOR = "TabContainer_TabPanelMain_WebUserControlFloorsMain_"
|
||||
DP = "TabContainer_TabPanelDoorsPanel_"
|
||||
VP = "TabContainer_TabPanelVentilationPanel_"
|
||||
APT = "TabContainer_TabPanelAirPressureTest_"
|
||||
LP = "TabContainer_TabPanelLighting_"
|
||||
MV = "TabContainer_TabPanelMechVent_"
|
||||
WH = "TabContainer_TabPanelWaterHeating_"
|
||||
MH1B = "TabContainer_TabPanelMainHeating1_WebUserControlMainHeating1_"
|
||||
_SAMPLE_DIR = (Path(__file__).parent.parent.parent
|
||||
/ "backend/epc_api/json_samples/real_life_examples"
|
||||
/ "RdSAP-Schema-21.0.1/uprn_100061275133")
|
||||
|
||||
|
||||
def _pick(page, suffix, contains):
|
||||
val = page.evaluate(
|
||||
"""(a)=>{const s=document.getElementById(a[0]);if(!s)return null;
|
||||
for(const o of s.options){if(o.text.toLowerCase().includes(a[1].toLowerCase()))return o.value;}return null;}""",
|
||||
[f"{E.FP}{suffix}", contains])
|
||||
if val is not None:
|
||||
E.set_select(page, suffix, val)
|
||||
return val
|
||||
|
||||
|
||||
def property_description(page):
|
||||
E.goto(page, "PropertyDescription", "WebFormPropertyDescription.aspx")
|
||||
E.set_select(page, "DropDownListPropertyType1", "H House")
|
||||
_pick(page, "DropDownListPropertyType2", "semi")
|
||||
E.set_text(page, "TextBoxStoreys", "2")
|
||||
E.set_text(page, "TextBoxHabitableRooms", "3")
|
||||
E.set_text(page, "TextBoxHeatedHabitableRooms", "3")
|
||||
print("date ->", _pick(page, "DropDownListDateBuiltMain", "1900-1929"))
|
||||
E.set_select(page, "DropDownListDateBuiltFirst", "")
|
||||
E.set_select(page, "DropDownListRoomInRoofMain", "")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def dimensions(page):
|
||||
E.goto(page, "Dimensions", "WebFormDimensions.aspx")
|
||||
E.set_text(page, f"{DIM}TextBoxFloorAreaLowestFloor", "38.99")
|
||||
E.set_text(page, f"{DIM}TextBoxRoomHeightLowestFloor", "2.40")
|
||||
E.set_text(page, f"{DIM}TextBoxWallPerimeterLowestFloor", "17.92")
|
||||
E.set_text(page, f"{DIM}TextBoxPartyWallLengthLowestFloor", "5.09")
|
||||
E.set_text(page, f"{DIM}TextBoxFloorArea1stFloor", "38.99")
|
||||
E.set_text(page, f"{DIM}TextBoxRoomHeight1stFloor", "2.40")
|
||||
E.set_text(page, f"{DIM}TextBoxWallPerimeter1stFloor", "17.92")
|
||||
E.set_text(page, f"{DIM}TextBoxPartyWallLength1stFloor", "5.09")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def walls(page):
|
||||
E.goto(page, "Walls", "WebFormWalls.aspx")
|
||||
_pick(page, f"{WALL}DropDownListType", "solid brick")
|
||||
page.wait_for_timeout(500)
|
||||
print("insulation ->", _pick(page, f"{WALL}DropDownListInsulation", "external"))
|
||||
print("party ->", _pick(page, f"{PWALL}DropDownListPartyWallType", "determine")
|
||||
or _pick(page, f"{PWALL}DropDownListPartyWallType", "masonry"))
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def roofs(page):
|
||||
E.goto(page, "Roofs", "WebFormRoofs.aspx")
|
||||
_pick(page, f"{ROOF}DropDownListType", "access to loft") or \
|
||||
_pick(page, f"{ROOF}DropDownListType", "loft")
|
||||
_pick(page, f"{ROOF}DropDownListInsulationAt", "joists")
|
||||
_pick(page, f"{ROOF}DropDownListThickness", "300")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def floors(page):
|
||||
E.goto(page, "Floors", "WebFormFloors.aspx")
|
||||
_pick(page, f"{FLOOR}DropDownListLocation", "ground floor")
|
||||
page.wait_for_timeout(400)
|
||||
_pick(page, f"{FLOOR}DropDownListType", "suspended")
|
||||
ins = page.locator(f"#{E.FP}{FLOOR}DropDownListInsulation")
|
||||
if ins.count():
|
||||
E.set_select(page, f"{FLOOR}DropDownListInsulation", "A As built")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def openings(page):
|
||||
E.goto(page, "Openings", "WebFormOpenings.aspx")
|
||||
E.click_tab(page, "TabContainer_TabPanelWindowsPanel")
|
||||
page.wait_for_timeout(500)
|
||||
E.set_single_window(page, 15.32, "North", _glazing(page))
|
||||
E.click_tab(page, "TabContainer_TabPanelDoorsPanel")
|
||||
E.set_text(page, f"{DP}TextBoxDoors", "2")
|
||||
E.set_text(page, f"{DP}TextBoxDoorsInsulated", "0")
|
||||
E.set_text(page, f"{DP}TextBoxDraughtProofedDoors", "0")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def _glazing(page):
|
||||
# glazed_type 13 -> double glazed, 2022 or later (U 1.4)
|
||||
return "Double post or during 2022"
|
||||
|
||||
|
||||
def ventilation(page):
|
||||
E.goto(page, "VentilationAndCooling", "WebFormVentilationAndCooling.aspx")
|
||||
E.click_tab(page, "TabContainer_TabPanelVentilationPanel")
|
||||
E.set_text(page, f"{VP}TextBoxIntermittentFans", "1")
|
||||
cool = page.locator(f"#{E.FP}{VP}CheckBoxFixedSpaceCooling")
|
||||
if cool.count() and cool.is_checked():
|
||||
E.commit(page, cool.uncheck)
|
||||
E.click_tab(page, "TabContainer_TabPanelMechVent")
|
||||
mv = page.locator(f"#{E.FP}{MV}CheckBoxMechanicalVentilation")
|
||||
if mv.count() and mv.is_checked():
|
||||
E.commit(page, mv.uncheck)
|
||||
E.click_tab(page, "TabContainer_TabPanelAirPressureTest")
|
||||
E.set_select(page, f"{APT}DropDownListTestMethod", "Not available")
|
||||
E.click_tab(page, "TabContainer_TabPanelLighting")
|
||||
E.set_text(page, f"{LP}TextBoxLightsTotal", "6")
|
||||
E.set_text(page, f"{LP}TextBoxLedLightsTotal", "0")
|
||||
E.set_text(page, f"{LP}TextBoxCflLightsTotal", "0")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def space_heating(page):
|
||||
E.goto(page, "SpaceHeating", "WebFormSpaceHeating.aspx")
|
||||
page.wait_for_timeout(1000)
|
||||
mhc = page.locator(f"#{E.MH1}TextBoxMainHeatingCode")
|
||||
code = mhc.input_value() if mhc.count() else ""
|
||||
if code and code not in ("0",):
|
||||
print(f"clearing leftover MainHeatingCode {code}")
|
||||
page.evaluate("""(id)=>{const e=document.getElementById(id);if(e){e.value='';
|
||||
e.dispatchEvent(new Event('change',{bubbles:true}));}}""", f"{E.MH1}TextBoxMainHeatingCode")
|
||||
page.wait_for_timeout(400)
|
||||
E.save_close(page)
|
||||
return
|
||||
E.set_heating_dialog(page, f"{MH1B}ButtonMainHeatingCode",
|
||||
"^Gas", "Mains gas", "Boilers", "Post 1998", "Condensing",
|
||||
"Combi condens")
|
||||
print("code:", page.locator(f"#{E.MH1}TextBoxMainHeatingCode").input_value())
|
||||
E.set_heating_dialog(page, f"{MH1B}ButtonMainHeatingControls",
|
||||
"^Boilers", "^Standard", "CBE Programmer, room thermostat and TRVs")
|
||||
print("control:", page.locator(f"#{E.MH1}TextBoxMainHeatingControls").input_value())
|
||||
E.set_select(page, "DropDownListSecondaryHeatingPresent", "No")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def _unused_secondary(page):
|
||||
E.goto(page, "SpaceHeating", "WebFormSpaceHeating.aspx")
|
||||
page.wait_for_timeout(600)
|
||||
E.set_select(page, "DropDownListSecondaryHeatingPresent", "Yes")
|
||||
page.wait_for_timeout(900)
|
||||
E.set_heating_dialog(page, "ButtonSecondaryHeatingCode",
|
||||
"^Gas", "Mains gas", "Room Heater")
|
||||
tb = page.locator(f"#{E.FP}TextBoxSecondaryHeatingCode")
|
||||
print("secondary code:", tb.input_value() if tb.count() else "?")
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def water_heating(page):
|
||||
E.goto(page, "WaterHeating", "WebFormWaterHeating.aspx")
|
||||
E.click_tab(page, "TabContainer_TabPanelWaterHeating")
|
||||
page.wait_for_timeout(400)
|
||||
E.clear_hot_water_cylinder(page)
|
||||
E.set_heating_dialog(page, f"{WH}ButtonWaterHeatingCode",
|
||||
"From Space Heating", "From the primary heating system")
|
||||
print("water code:", page.locator(f"#{E.FP}{WH}TextBoxWaterHeatingCode").input_value())
|
||||
E.save_close(page)
|
||||
|
||||
|
||||
def download(page):
|
||||
_SAMPLE_DIR.mkdir(parents=True, exist_ok=True)
|
||||
E.goto(page, "Recommendations", "WebFormRecommendations.aspx")
|
||||
page.wait_for_timeout(1500)
|
||||
with page.expect_navigation(wait_until="networkidle", timeout=40000):
|
||||
page.click("#ContentBody_buttonActionSummary_Link", timeout=15000)
|
||||
page.wait_for_timeout(2000)
|
||||
for btn, fname in (("ContentBody_ContentPlaceHolder1_LinkButtonSummary", "elmhurst_summary.pdf"),
|
||||
("ContentBody_ContentPlaceHolder1_ButtonDebugInforPdf", "elmhurst_worksheet.pdf")):
|
||||
try:
|
||||
with page.expect_download(timeout=60000) as dl:
|
||||
page.click(f"#{btn}", timeout=15000)
|
||||
dl.value.save_as(str(_SAMPLE_DIR / fname))
|
||||
print("saved", fname)
|
||||
except Exception as e:
|
||||
print("!! download failed", fname, type(e).__name__, str(e)[:120])
|
||||
|
||||
|
||||
def cleanup(page):
|
||||
"""Leave the shared assessment neutral for the next build."""
|
||||
E.reset_transient_state(page)
|
||||
print("reset transient state (RR/secondary/meter)")
|
||||
|
||||
|
||||
_ORDER = ["property_description", "dimensions", "walls", "roofs", "floors",
|
||||
"openings", "ventilation", "space_heating",
|
||||
"water_heating", "download", "cleanup"]
|
||||
|
||||
|
||||
def main():
|
||||
if len(sys.argv) < 2 or sys.argv[1] not in _ORDER:
|
||||
print("usage: build_100061275133.py <" + "|".join(_ORDER) + ">")
|
||||
return 2
|
||||
with E.session() as (ctx, page):
|
||||
globals()[sys.argv[1]](page)
|
||||
print("done:", sys.argv[1], "->", page.url)
|
||||
return 0
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
raise SystemExit(main())
|
||||
|
|
@ -863,6 +863,28 @@ _EXPECTATIONS: Final[tuple[RealCertExpectation, ...]] = (
|
|||
cert_num="uprn-217091901",
|
||||
sap_score=61,
|
||||
),
|
||||
# UPRN 100061275133 (corpus; no cert number lodged). RdSAP-21.0.1 native —
|
||||
# 2-storey SEMI-DETACHED HOUSE, band B, SOLID BRICK 400 mm with EXTERNAL
|
||||
# insulation, pitched 300 mm loft, SUSPENDED uninsulated ground floor,
|
||||
# mains-gas COMBI, double glazing (glazed_type 13, 2022+), TFA 78.
|
||||
# Lodged 76 / engine 77 (77.24). Built in accredited Elmhurst RdSAP10
|
||||
# (evidence saved: elmhurst_summary.pdf / elmhurst_worksheet.pdf): the
|
||||
# checkable FABRIC matches the engine closely — ROOF (300 mm loft, U 0.14)
|
||||
# and WINDOWS (15.32 m² × eff U 1.3258 = 20.3106 W/K) match EXACTLY; the
|
||||
# externally-insulated WALL is U 0.29 (engine) vs 0.30 (Elmhurst) — which
|
||||
# VALIDATES the slice-5 external-insulation default (100 mm added over solid
|
||||
# brick, `_WALL_ADDED_INSULATION_UNKNOWN_THICKNESS_MM`); the suspended
|
||||
# ground floor is U 0.68 (engine) vs 0.70 (Elmhurst). (Elmhurst''s overall
|
||||
# worksheet SAP 67 is NOT comparable — the reused-assessment combi entered
|
||||
# as a "Standard Combi" carries a ~50 kWh/month Table-3a keep-hot loss the
|
||||
# lodged assessment did not, a build-side heating artifact, not an engine
|
||||
# gap.) Engine 77 sits within 1.24 of lodged; PINNED to the observed 77.
|
||||
RealCertExpectation(
|
||||
schema="RdSAP-Schema-21.0.1",
|
||||
sample="uprn_100061275133",
|
||||
cert_num="uprn-100061275133",
|
||||
sap_score=77,
|
||||
),
|
||||
)
|
||||
|
||||
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue