mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Fix bug in filtering averages in lighting description
This commit is contained in:
parent
e51a2142fd
commit
290ff65f1b
2 changed files with 213 additions and 1 deletions
|
|
@ -20,7 +20,9 @@ class LightingAttributes:
|
|||
if ('good lighting efficiency' in description) or ('excellent lighting efficiency' in description) or \
|
||||
('below average lighting efficiency' in description):
|
||||
return {
|
||||
"low_energy_proportion": self.averages[self.averages == description]["low-energy-lighting"].values[0]
|
||||
"low_energy_proportion": self.averages[
|
||||
self.averages["lighting-description"] == description
|
||||
]["low-energy-lighting"].values[0]
|
||||
}
|
||||
|
||||
match = re.search(r'\d+', description)
|
||||
|
|
|
|||
210
model_data/tests/test_data/test_lighting_attributes_cases.py
Normal file
210
model_data/tests/test_data/test_lighting_attributes_cases.py
Normal file
|
|
@ -0,0 +1,210 @@
|
|||
test_cases = [{'original_description': 'Low energy lighting in all fixed outlets', 'low_energy_proportion': 1},
|
||||
{'original_description': 'Low energy lighting in 88% of fixed outlets', 'low_energy_proportion': 0.88},
|
||||
{'original_description': 'No low energy lighting', 'low_energy_proportion': 0},
|
||||
{'original_description': 'Low energy lighting in 60% of fixed outlets', 'low_energy_proportion': 0.6},
|
||||
{'original_description': 'Low energy lighting in 80% of fixed outlets', 'low_energy_proportion': 0.8},
|
||||
{'original_description': 'Low energy lighting in 83% of fixed outlets', 'low_energy_proportion': 0.83},
|
||||
{'original_description': 'Low energy lighting in 20% of fixed outlets', 'low_energy_proportion': 0.2},
|
||||
{'original_description': 'Low energy lighting in 67% of fixed outlets', 'low_energy_proportion': 0.67},
|
||||
{'original_description': 'Low energy lighting in 40% of fixed outlets', 'low_energy_proportion': 0.4},
|
||||
{'original_description': 'Low energy lighting in 11% of fixed outlets', 'low_energy_proportion': 0.11},
|
||||
{'original_description': 'Low energy lighting in 57% of fixed outlets', 'low_energy_proportion': 0.57},
|
||||
{'original_description': 'Low energy lighting in 29% of fixed outlets', 'low_energy_proportion': 0.29},
|
||||
{'original_description': 'Low energy lighting in 71% of fixed outlets', 'low_energy_proportion': 0.71},
|
||||
{'original_description': 'Low energy lighting in 19% of fixed outlets', 'low_energy_proportion': 0.19},
|
||||
{'original_description': 'Low energy lighting in 30% of fixed outlets', 'low_energy_proportion': 0.3},
|
||||
{'original_description': 'Low energy lighting in 92% of fixed outlets', 'low_energy_proportion': 0.92},
|
||||
{'original_description': 'Low energy lighting in 93% of fixed outlets', 'low_energy_proportion': 0.93},
|
||||
{'original_description': 'Low energy lighting in 95% of fixed outlets', 'low_energy_proportion': 0.95},
|
||||
{'original_description': 'Low energy lighting in 85% of fixed outlets', 'low_energy_proportion': 0.85},
|
||||
{'original_description': 'Low energy lighting in 86% of fixed outlets', 'low_energy_proportion': 0.86},
|
||||
{'original_description': 'Low energy lighting in 50% of fixed outlets', 'low_energy_proportion': 0.5},
|
||||
{'original_description': 'Low energy lighting in 25% of fixed outlets', 'low_energy_proportion': 0.25},
|
||||
{'original_description': 'Low energy lighting in 82% of fixed outlets', 'low_energy_proportion': 0.82},
|
||||
{'original_description': 'Low energy lighting in 78% of fixed outlets', 'low_energy_proportion': 0.78},
|
||||
{'original_description': 'Low energy lighting in 38% of fixed outlets', 'low_energy_proportion': 0.38},
|
||||
{'original_description': 'Low energy lighting in 90% of fixed outlets', 'low_energy_proportion': 0.9},
|
||||
{'original_description': 'Low energy lighting in 63% of fixed outlets', 'low_energy_proportion': 0.63},
|
||||
{'original_description': 'Low energy lighting in 75% of fixed outlets', 'low_energy_proportion': 0.75},
|
||||
{'original_description': 'Low energy lighting in 36% of fixed outlets', 'low_energy_proportion': 0.36},
|
||||
{'original_description': 'Low energy lighting in 43% of fixed outlets', 'low_energy_proportion': 0.43},
|
||||
{'original_description': 'Low energy lighting in 70% of fixed outlets', 'low_energy_proportion': 0.7},
|
||||
{'original_description': 'Low energy lighting in 33% of fixed outlets', 'low_energy_proportion': 0.33},
|
||||
{'original_description': 'Low energy lighting in 91% of fixed outlets', 'low_energy_proportion': 0.91},
|
||||
{'original_description': 'Low energy lighting in 42% of fixed outlets', 'low_energy_proportion': 0.42},
|
||||
{'original_description': 'Low energy lighting in 46% of fixed outlets', 'low_energy_proportion': 0.46},
|
||||
{'original_description': 'Low energy lighting in 6% of fixed outlets', 'low_energy_proportion': 0.06},
|
||||
{'original_description': 'Low energy lighting in 81% of fixed outlets', 'low_energy_proportion': 0.81},
|
||||
{'original_description': 'Low energy lighting in 65% of fixed outlets', 'low_energy_proportion': 0.65},
|
||||
{'original_description': 'Low energy lighting in 56% of fixed outlets', 'low_energy_proportion': 0.56},
|
||||
{'original_description': 'Low energy lighting in 21% of fixed outlets', 'low_energy_proportion': 0.21},
|
||||
{'original_description': 'Low energy lighting in 44% of fixed outlets', 'low_energy_proportion': 0.44},
|
||||
{'original_description': 'Low energy lighting in 79% of fixed outlets', 'low_energy_proportion': 0.79},
|
||||
{'original_description': 'Low energy lighting in 73% of fixed outlets', 'low_energy_proportion': 0.73},
|
||||
{'original_description': 'Low energy lighting in 27% of fixed outlets', 'low_energy_proportion': 0.27},
|
||||
{'original_description': 'Low energy lighting in 94% of fixed outlets', 'low_energy_proportion': 0.94},
|
||||
{'original_description': 'Low energy lighting in 47% of fixed outlets', 'low_energy_proportion': 0.47},
|
||||
{'original_description': 'Low energy lighting in 69% of fixed outlets', 'low_energy_proportion': 0.69},
|
||||
{'original_description': 'Low energy lighting in 77% of fixed outlets', 'low_energy_proportion': 0.77},
|
||||
{'original_description': 'Low energy lighting in 45% of fixed outlets', 'low_energy_proportion': 0.45},
|
||||
{'original_description': 'Low energy lighting in 89% of fixed outlets', 'low_energy_proportion': 0.89},
|
||||
{'original_description': 'Low energy lighting in 54% of fixed outlets', 'low_energy_proportion': 0.54},
|
||||
{'original_description': 'Low energy lighting in 87% of fixed outlets', 'low_energy_proportion': 0.87},
|
||||
{'original_description': 'Low energy lighting in 22% of fixed outlets', 'low_energy_proportion': 0.22},
|
||||
{'original_description': 'Low energy lighting in 53% of fixed outlets', 'low_energy_proportion': 0.53},
|
||||
{'original_description': 'Low energy lighting in 55% of fixed outlets', 'low_energy_proportion': 0.55},
|
||||
{'original_description': 'Low energy lighting in 64% of fixed outlets', 'low_energy_proportion': 0.64},
|
||||
{'original_description': 'Low energy lighting in 58% of fixed outlets', 'low_energy_proportion': 0.58},
|
||||
{'original_description': 'Low energy lighting in 84% of fixed outlets', 'low_energy_proportion': 0.84},
|
||||
{'original_description': 'Low energy lighting in 17% of fixed outlets', 'low_energy_proportion': 0.17},
|
||||
{'original_description': 'Low energy lighting in 7% of fixed outlets', 'low_energy_proportion': 0.07},
|
||||
{'original_description': 'Low energy lighting in 76% of fixed outlets', 'low_energy_proportion': 0.76},
|
||||
{'original_description': 'Low energy lighting in 18% of fixed outlets', 'low_energy_proportion': 0.18},
|
||||
{'original_description': 'Low energy lighting in 31% of fixed outlets', 'low_energy_proportion': 0.31},
|
||||
{'original_description': 'Low energy lighting in 62% of fixed outlets', 'low_energy_proportion': 0.62},
|
||||
{'original_description': 'Low energy lighting in 14% of fixed outlets', 'low_energy_proportion': 0.14},
|
||||
{'original_description': 'Low energy lighting in 61% of fixed outlets', 'low_energy_proportion': 0.61},
|
||||
{'original_description': 'Low energy lighting in 9% of fixed outlets', 'low_energy_proportion': 0.09},
|
||||
{'original_description': 'Low energy lighting in 68% of fixed outlets', 'low_energy_proportion': 0.68},
|
||||
{'original_description': 'Low energy lighting in 13% of fixed outlets', 'low_energy_proportion': 0.13},
|
||||
{'original_description': 'Low energy lighting in 52% of fixed outlets', 'low_energy_proportion': 0.52},
|
||||
{'original_description': 'Low energy lighting in 24% of fixed outlets', 'low_energy_proportion': 0.24},
|
||||
{'original_description': 'Low energy lighting in 48% of fixed outlets', 'low_energy_proportion': 0.48},
|
||||
{'original_description': 'Low energy lighting in 41% of fixed outlets', 'low_energy_proportion': 0.41},
|
||||
{'original_description': 'Low energy lighting in 8% of fixed outlets', 'low_energy_proportion': 0.08},
|
||||
{'original_description': 'Low energy lighting in 72% of fixed outlets', 'low_energy_proportion': 0.72},
|
||||
{'original_description': 'Low energy lighting in 23% of fixed outlets', 'low_energy_proportion': 0.23},
|
||||
{'original_description': 'Low energy lighting in 96% of fixed outlets', 'low_energy_proportion': 0.96},
|
||||
{'original_description': 'Low energy lighting in 12% of fixed outlets', 'low_energy_proportion': 0.12},
|
||||
{'original_description': 'Low energy lighting in 15% of fixed outlets', 'low_energy_proportion': 0.15},
|
||||
{'original_description': 'Low energy lighting in 39% of fixed outlets', 'low_energy_proportion': 0.39},
|
||||
{'original_description': 'Low energy lighting in 32% of fixed outlets', 'low_energy_proportion': 0.32},
|
||||
{'original_description': 'Low energy lighting in 74% of fixed outlets', 'low_energy_proportion': 0.74},
|
||||
{'original_description': 'Low energy lighting in 49% of fixed outlets', 'low_energy_proportion': 0.49},
|
||||
{'original_description': 'Low energy lighting in 97% of fixed outlets', 'low_energy_proportion': 0.97},
|
||||
{'original_description': 'Low energy lighting in 10% of fixed outlets', 'low_energy_proportion': 0.1},
|
||||
{'original_description': 'Low energy lighting in 35% of fixed outlets', 'low_energy_proportion': 0.35},
|
||||
{'original_description': 'Low energy lighting in 5% of fixed outlets', 'low_energy_proportion': 0.05},
|
||||
{'original_description': 'Low energy lighting in 59% of fixed outlets', 'low_energy_proportion': 0.59},
|
||||
{'original_description': 'Low energy lighting in 37% of fixed outlets', 'low_energy_proportion': 0.37},
|
||||
{'original_description': 'Low energy lighting in 16% of fixed outlets', 'low_energy_proportion': 0.16},
|
||||
{'original_description': 'Low energy lighting in 4% of fixed outlets', 'low_energy_proportion': 0.04},
|
||||
{'original_description': 'Low energy lighting in 3% of fixed outlets', 'low_energy_proportion': 0.03},
|
||||
{'original_description': 'Low energy lighting in 28% of fixed outlets', 'low_energy_proportion': 0.28},
|
||||
{'original_description': 'Low energy lighting in 26% of fixed outlets', 'low_energy_proportion': 0.26},
|
||||
{'original_description': 'Low energy lighting in 34% of fixed outlets', 'low_energy_proportion': 0.34},
|
||||
{'original_description': 'Low energy lighting in 66% of fixed outlets', 'low_energy_proportion': 0.66},
|
||||
{'original_description': 'Low energy lighting in 98% of fixed outlets', 'low_energy_proportion': 0.98},
|
||||
{'original_description': 'Low energy lighting in 51% of fixed outlets', 'low_energy_proportion': 0.51},
|
||||
{'original_description': 'Low energy lighting in 99% of fixed outlets', 'low_energy_proportion': 0.99},
|
||||
{'original_description': 'Low energy lighting in 100% of fixed outlets', 'low_energy_proportion': 1.0},
|
||||
{'original_description': 'Good lighting efficiency', 'low_energy_proportion': nan},
|
||||
{'original_description': 'Below average lighting efficiency', 'low_energy_proportion': nan},
|
||||
{'original_description': 'Excelent lighting efficiency', 'low_energy_proportion': 0},
|
||||
{'original_description': 'Low energy lighting in 2% of fixed outlets', 'low_energy_proportion': 0.02},
|
||||
{'original_description': 'No Low energy lighting', 'low_energy_proportion': 0},
|
||||
{'original_description': 'Low energy lighting in all fixed outlets', 'low_energy_proportion': 1},
|
||||
{'original_description': 'Low energy lighting in 88% of fixed outlets', 'low_energy_proportion': 0.88},
|
||||
{'original_description': 'No low energy lighting', 'low_energy_proportion': 0},
|
||||
{'original_description': 'Low energy lighting in 60% of fixed outlets', 'low_energy_proportion': 0.6},
|
||||
{'original_description': 'Low energy lighting in 80% of fixed outlets', 'low_energy_proportion': 0.8},
|
||||
{'original_description': 'Low energy lighting in 83% of fixed outlets', 'low_energy_proportion': 0.83},
|
||||
{'original_description': 'Low energy lighting in 20% of fixed outlets', 'low_energy_proportion': 0.2},
|
||||
{'original_description': 'Low energy lighting in 67% of fixed outlets', 'low_energy_proportion': 0.67},
|
||||
{'original_description': 'Low energy lighting in 40% of fixed outlets', 'low_energy_proportion': 0.4},
|
||||
{'original_description': 'Low energy lighting in 11% of fixed outlets', 'low_energy_proportion': 0.11},
|
||||
{'original_description': 'Low energy lighting in 57% of fixed outlets', 'low_energy_proportion': 0.57},
|
||||
{'original_description': 'Low energy lighting in 29% of fixed outlets', 'low_energy_proportion': 0.29},
|
||||
{'original_description': 'Low energy lighting in 71% of fixed outlets', 'low_energy_proportion': 0.71},
|
||||
{'original_description': 'Low energy lighting in 19% of fixed outlets', 'low_energy_proportion': 0.19},
|
||||
{'original_description': 'Low energy lighting in 30% of fixed outlets', 'low_energy_proportion': 0.3},
|
||||
{'original_description': 'Low energy lighting in 92% of fixed outlets', 'low_energy_proportion': 0.92},
|
||||
{'original_description': 'Low energy lighting in 93% of fixed outlets', 'low_energy_proportion': 0.93},
|
||||
{'original_description': 'Low energy lighting in 95% of fixed outlets', 'low_energy_proportion': 0.95},
|
||||
{'original_description': 'Low energy lighting in 85% of fixed outlets', 'low_energy_proportion': 0.85},
|
||||
{'original_description': 'Low energy lighting in 86% of fixed outlets', 'low_energy_proportion': 0.86},
|
||||
{'original_description': 'Low energy lighting in 50% of fixed outlets', 'low_energy_proportion': 0.5},
|
||||
{'original_description': 'Low energy lighting in 25% of fixed outlets', 'low_energy_proportion': 0.25},
|
||||
{'original_description': 'Low energy lighting in 82% of fixed outlets', 'low_energy_proportion': 0.82},
|
||||
{'original_description': 'Low energy lighting in 78% of fixed outlets', 'low_energy_proportion': 0.78},
|
||||
{'original_description': 'Low energy lighting in 38% of fixed outlets', 'low_energy_proportion': 0.38},
|
||||
{'original_description': 'Low energy lighting in 90% of fixed outlets', 'low_energy_proportion': 0.9},
|
||||
{'original_description': 'Low energy lighting in 63% of fixed outlets', 'low_energy_proportion': 0.63},
|
||||
{'original_description': 'Low energy lighting in 75% of fixed outlets', 'low_energy_proportion': 0.75},
|
||||
{'original_description': 'Low energy lighting in 36% of fixed outlets', 'low_energy_proportion': 0.36},
|
||||
{'original_description': 'Low energy lighting in 43% of fixed outlets', 'low_energy_proportion': 0.43},
|
||||
{'original_description': 'Low energy lighting in 70% of fixed outlets', 'low_energy_proportion': 0.7},
|
||||
{'original_description': 'Low energy lighting in 33% of fixed outlets', 'low_energy_proportion': 0.33},
|
||||
{'original_description': 'Low energy lighting in 91% of fixed outlets', 'low_energy_proportion': 0.91},
|
||||
{'original_description': 'Low energy lighting in 42% of fixed outlets', 'low_energy_proportion': 0.42},
|
||||
{'original_description': 'Low energy lighting in 46% of fixed outlets', 'low_energy_proportion': 0.46},
|
||||
{'original_description': 'Low energy lighting in 6% of fixed outlets', 'low_energy_proportion': 0.06},
|
||||
{'original_description': 'Low energy lighting in 81% of fixed outlets', 'low_energy_proportion': 0.81},
|
||||
{'original_description': 'Low energy lighting in 65% of fixed outlets', 'low_energy_proportion': 0.65},
|
||||
{'original_description': 'Low energy lighting in 56% of fixed outlets', 'low_energy_proportion': 0.56},
|
||||
{'original_description': 'Low energy lighting in 21% of fixed outlets', 'low_energy_proportion': 0.21},
|
||||
{'original_description': 'Low energy lighting in 44% of fixed outlets', 'low_energy_proportion': 0.44},
|
||||
{'original_description': 'Low energy lighting in 79% of fixed outlets', 'low_energy_proportion': 0.79},
|
||||
{'original_description': 'Low energy lighting in 73% of fixed outlets', 'low_energy_proportion': 0.73},
|
||||
{'original_description': 'Low energy lighting in 27% of fixed outlets', 'low_energy_proportion': 0.27},
|
||||
{'original_description': 'Low energy lighting in 94% of fixed outlets', 'low_energy_proportion': 0.94},
|
||||
{'original_description': 'Low energy lighting in 47% of fixed outlets', 'low_energy_proportion': 0.47},
|
||||
{'original_description': 'Low energy lighting in 69% of fixed outlets', 'low_energy_proportion': 0.69},
|
||||
{'original_description': 'Low energy lighting in 77% of fixed outlets', 'low_energy_proportion': 0.77},
|
||||
{'original_description': 'Low energy lighting in 45% of fixed outlets', 'low_energy_proportion': 0.45},
|
||||
{'original_description': 'Low energy lighting in 89% of fixed outlets', 'low_energy_proportion': 0.89},
|
||||
{'original_description': 'Low energy lighting in 54% of fixed outlets', 'low_energy_proportion': 0.54},
|
||||
{'original_description': 'Low energy lighting in 87% of fixed outlets', 'low_energy_proportion': 0.87},
|
||||
{'original_description': 'Low energy lighting in 22% of fixed outlets', 'low_energy_proportion': 0.22},
|
||||
{'original_description': 'Low energy lighting in 53% of fixed outlets', 'low_energy_proportion': 0.53},
|
||||
{'original_description': 'Low energy lighting in 55% of fixed outlets', 'low_energy_proportion': 0.55},
|
||||
{'original_description': 'Low energy lighting in 64% of fixed outlets', 'low_energy_proportion': 0.64},
|
||||
{'original_description': 'Low energy lighting in 58% of fixed outlets', 'low_energy_proportion': 0.58},
|
||||
{'original_description': 'Low energy lighting in 84% of fixed outlets', 'low_energy_proportion': 0.84},
|
||||
{'original_description': 'Low energy lighting in 17% of fixed outlets', 'low_energy_proportion': 0.17},
|
||||
{'original_description': 'Low energy lighting in 7% of fixed outlets', 'low_energy_proportion': 0.07},
|
||||
{'original_description': 'Low energy lighting in 76% of fixed outlets', 'low_energy_proportion': 0.76},
|
||||
{'original_description': 'Low energy lighting in 18% of fixed outlets', 'low_energy_proportion': 0.18},
|
||||
{'original_description': 'Low energy lighting in 31% of fixed outlets', 'low_energy_proportion': 0.31},
|
||||
{'original_description': 'Low energy lighting in 62% of fixed outlets', 'low_energy_proportion': 0.62},
|
||||
{'original_description': 'Low energy lighting in 14% of fixed outlets', 'low_energy_proportion': 0.14},
|
||||
{'original_description': 'Low energy lighting in 61% of fixed outlets', 'low_energy_proportion': 0.61},
|
||||
{'original_description': 'Low energy lighting in 9% of fixed outlets', 'low_energy_proportion': 0.09},
|
||||
{'original_description': 'Low energy lighting in 68% of fixed outlets', 'low_energy_proportion': 0.68},
|
||||
{'original_description': 'Low energy lighting in 13% of fixed outlets', 'low_energy_proportion': 0.13},
|
||||
{'original_description': 'Low energy lighting in 52% of fixed outlets', 'low_energy_proportion': 0.52},
|
||||
{'original_description': 'Low energy lighting in 24% of fixed outlets', 'low_energy_proportion': 0.24},
|
||||
{'original_description': 'Low energy lighting in 48% of fixed outlets', 'low_energy_proportion': 0.48},
|
||||
{'original_description': 'Low energy lighting in 41% of fixed outlets', 'low_energy_proportion': 0.41},
|
||||
{'original_description': 'Low energy lighting in 8% of fixed outlets', 'low_energy_proportion': 0.08},
|
||||
{'original_description': 'Low energy lighting in 72% of fixed outlets', 'low_energy_proportion': 0.72},
|
||||
{'original_description': 'Low energy lighting in 23% of fixed outlets', 'low_energy_proportion': 0.23},
|
||||
{'original_description': 'Low energy lighting in 96% of fixed outlets', 'low_energy_proportion': 0.96},
|
||||
{'original_description': 'Low energy lighting in 12% of fixed outlets', 'low_energy_proportion': 0.12},
|
||||
{'original_description': 'Low energy lighting in 15% of fixed outlets', 'low_energy_proportion': 0.15},
|
||||
{'original_description': 'Low energy lighting in 39% of fixed outlets', 'low_energy_proportion': 0.39},
|
||||
{'original_description': 'Low energy lighting in 32% of fixed outlets', 'low_energy_proportion': 0.32},
|
||||
{'original_description': 'Low energy lighting in 74% of fixed outlets', 'low_energy_proportion': 0.74},
|
||||
{'original_description': 'Low energy lighting in 49% of fixed outlets', 'low_energy_proportion': 0.49},
|
||||
{'original_description': 'Low energy lighting in 97% of fixed outlets', 'low_energy_proportion': 0.97},
|
||||
{'original_description': 'Low energy lighting in 10% of fixed outlets', 'low_energy_proportion': 0.1},
|
||||
{'original_description': 'Low energy lighting in 35% of fixed outlets', 'low_energy_proportion': 0.35},
|
||||
{'original_description': 'Low energy lighting in 5% of fixed outlets', 'low_energy_proportion': 0.05},
|
||||
{'original_description': 'Low energy lighting in 59% of fixed outlets', 'low_energy_proportion': 0.59},
|
||||
{'original_description': 'Low energy lighting in 37% of fixed outlets', 'low_energy_proportion': 0.37},
|
||||
{'original_description': 'Low energy lighting in 16% of fixed outlets', 'low_energy_proportion': 0.16},
|
||||
{'original_description': 'Low energy lighting in 4% of fixed outlets', 'low_energy_proportion': 0.04},
|
||||
{'original_description': 'Low energy lighting in 3% of fixed outlets', 'low_energy_proportion': 0.03},
|
||||
{'original_description': 'Low energy lighting in 28% of fixed outlets', 'low_energy_proportion': 0.28},
|
||||
{'original_description': 'Low energy lighting in 26% of fixed outlets', 'low_energy_proportion': 0.26},
|
||||
{'original_description': 'Low energy lighting in 34% of fixed outlets', 'low_energy_proportion': 0.34},
|
||||
{'original_description': 'Low energy lighting in 66% of fixed outlets', 'low_energy_proportion': 0.66},
|
||||
{'original_description': 'Low energy lighting in 98% of fixed outlets', 'low_energy_proportion': 0.98},
|
||||
{'original_description': 'Low energy lighting in 51% of fixed outlets', 'low_energy_proportion': 0.51},
|
||||
{'original_description': 'Low energy lighting in 99% of fixed outlets', 'low_energy_proportion': 0.99},
|
||||
{'original_description': 'Low energy lighting in 100% of fixed outlets', 'low_energy_proportion': 1.0},
|
||||
{'original_description': 'Good lighting efficiency', 'low_energy_proportion': 98.16666666666667},
|
||||
{'original_description': 'Below average lighting efficiency', 'low_energy_proportion': 0.0},
|
||||
{'original_description': 'Excelent lighting efficiency', 'low_energy_proportion': 0},
|
||||
{'original_description': 'Low energy lighting in 2% of fixed outlets', 'low_energy_proportion': 0.02},
|
||||
{'original_description': 'No Low energy lighting', 'low_energy_proportion': 0}]
|
||||
Loading…
Add table
Reference in a new issue