Slice S0380.4: surface wall_insulation_thickness from Summary §7.0

Closes the three-layer gap that left the Summary mapper producing
`wall_insulation_thickness=None` even though Summary §7.0 lodges
"Insulation Thickness" / "100 mm" explicitly on cert 0380. Three
small co-ordinated edits ship the field end-to-end:

1. `datatypes/epc/surveys/elmhurst_site_notes.py` — add
   `WallDetails.insulation_thickness_mm: Optional[int] = None`,
   mirroring the existing `RoofDetails.insulation_thickness_mm`.
2. `backend/documents_parser/elmhurst_extractor.py` — extend
   `_wall_details_from_lines` to read the `_local_val(lines,
   "Insulation Thickness")` label inside the §7 Walls block (the
   "Insulation Thickness" label is local-scoped per block, so it
   does not collide with §8 Roofs / §9 Floors).
3. `datatypes/epc/domain/mapper.py` — surface
   `wall_insulation_thickness=f"{walls.insulation_thickness_mm}mm"`
   on `SapBuildingPart`. Mirrors the API mapper's string-with-unit
   shape (`'100mm'`) so cert-to-cert parity tests (Summary EPC ≡
   API EPC) compare equal; the cascade's `_parse_thickness_mm`
   accepts either form.

Forcing function (Slice S0380.1): cert 0380 Summary cascade SAP
moves from 86.8671 (Δ -1.6433 — i.e. after Slice S0380.3 only) to
88.1981 (Δ -0.3123) — closes ~81% of the remaining gap. Critically,
`walls_w_per_k` now hits API parity exactly (Summary 11.6150 ≡ API
11.6150) — the composite filled-cavity-plus-external U-value calc
is now keyed off the lodged 100 mm thickness rather than its
internal default.

Residual -0.31 SAP vs worksheet is comparable to the documented HP
cohort's API-path residual of +0.06 (cert 0380 API path closes at
+0.0594). Summary path is now within ±0.37 of API path. Remaining
diffs to investigate (per the next-step diagnostic): hot-water
cascade (Summary 1002.74 kWh vs API 878.05 kWh, +124.69 kWh), HLC
parameters (heat_transfer_coefficient still differs slightly through
secondary terms), and possibly secondary-heating routing. The
worksheet vs API +0.06 residual is the documented Appendix N3.6
PSR-interpolation precision floor and out of scope for Summary-path
closure.

Added focused unit test
`test_summary_0380_surfaces_wall_insulation_thickness_100mm` that
pins the mapper boundary directly (Summary "100 mm" line pair →
EPC `wall_insulation_thickness="100mm"`), so future debuggers can
localise regressions in the new extractor / field / mapper path
before walking the full chain.

Pyright net-zero across all four edited files:
  datatypes/epc/domain/mapper.py:                32 (baseline)
  datatypes/epc/surveys/elmhurst_site_notes.py:   0
  backend/documents_parser/elmhurst_extractor.py: 0
  backend/documents_parser/tests/test_summary_pdf_mapper_chain.py: 0

Regression suite: 672 pass + 11 fail (vs handover baseline 669 + 10
— net +3 pass for the three Slices S0380.2-4 GREEN unit tests; the
+1 fail vs baseline is still the S0380.1 chain test which this slice
moves from Δ -1.6433 to Δ -0.3123 but does not yet fully close).

Spec refs:
- SAP 10.2 §3.7 / Appendix S Table S5 (composite filled-cavity-plus-
  external U-value calc — series-resistance form keyed off lodged
  insulation thickness)
- Cert 0380 Summary PDF §7.0 lines 121-122 ("Insulation Thickness"
  / "100 mm" — the missing extractor read this slice adds)

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
Khalim Conn-Kowlessar 2026-05-27 18:15:18 +00:00
parent 575cdd539a
commit 2d15951bc1
4 changed files with 53 additions and 0 deletions

View file

@ -235,6 +235,19 @@ class ElmhurstSiteNotesExtractor:
thickness_mm = (
int(thickness_raw.split()[0]) if thickness_raw else None
)
# Composite / retrofit insulation thickness — Summary §7.0
# writes the value on the line pair "Insulation Thickness" /
# "100 mm" when a composite filled-cavity-plus-external (or
# equivalent) wall is lodged. The "Insulation Thickness" label
# is local-scoped inside the §7 block so it does not collide
# with the §8 Roofs / §9 Floors blocks. None when the PDF
# omits the line (no retrofit lodged).
ins_thickness_raw = self._local_val(lines, "Insulation Thickness")
insulation_thickness_mm = (
int(ins_thickness_raw.split()[0])
if ins_thickness_raw and ins_thickness_raw.split()[0].isdigit()
else None
)
return WallDetails(
wall_type=self._local_str(lines, "Type"),
insulation=self._local_str(lines, "Insulation"),
@ -242,6 +255,7 @@ class ElmhurstSiteNotesExtractor:
u_value_known=self._local_bool(lines, "U-value Known"),
party_wall_type=self._local_str(lines, "Party Wall Type"),
thickness_mm=thickness_mm,
insulation_thickness_mm=insulation_thickness_mm,
alternative_walls=self._alternative_walls_from_lines(lines),
)

View file

@ -538,6 +538,32 @@ def test_summary_0380_filled_cavity_plus_external_insulation_routes_to_code_6()
assert main.wall_insulation_type == 6 # 6 = filled cavity + external
def test_summary_0380_surfaces_wall_insulation_thickness_100mm() -> None:
# Arrange — cert 0380's Summary §7.0 Walls block lodges the
# composite-wall insulation thickness on the line pair
# "Insulation Thickness" / "100 mm". Without surfacing this to
# `wall_insulation_thickness`, the heat-transmission cascade
# falls through `_parse_thickness_mm(None) → None` and the
# composite filled-cavity-plus-external U-value calc uses its
# default thickness rather than the lodged 100 mm — leaving cert
# 0380's `walls_w_per_k` at 24.62 vs API's 11.62 even with
# `wall_insulation_type=6` set (Slice S0380.3). Mirror of the
# existing `_roof_details_from_lines` reader that surfaces roof
# `insulation_thickness_mm` from the same "Insulation Thickness"
# label.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000899_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert — match the API mapper's "100mm" string (the EPC schema
# type is `Optional[str]`; the cascade's `_parse_thickness_mm`
# strips non-digit trailers).
main = epc.sap_building_parts[0]
assert main.wall_insulation_thickness == "100mm"
def test_summary_0380_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert 0380-2471-3250-2596-8761 (Summary_000899.pdf /
# dr87-0001-000899.pdf) is the first heat-pump cert under per-cert

View file

@ -2824,6 +2824,15 @@ def _map_elmhurst_building_part(
party_wall_construction=_elmhurst_party_wall_construction_int(walls.party_wall_type),
sap_floor_dimensions=floor_dims,
wall_thickness_mm=walls.thickness_mm,
# API mapper lodges wall_insulation_thickness as the string
# "100mm"; the cascade's `_parse_thickness_mm` accepts the
# digit-prefix form. Mirror the API shape so cert-to-cert
# parity tests (Summary EPC ≡ API EPC) compare equal.
wall_insulation_thickness=(
f"{walls.insulation_thickness_mm}mm"
if walls.insulation_thickness_mm is not None
else None
),
roof_construction_type=_strip_code(roof.roof_type),
roof_insulation_location=_strip_code(roof.insulation),
roof_insulation_thickness=_resolve_sloping_ceiling_thickness(

View file

@ -79,6 +79,10 @@ class WallDetails:
default_factory=lambda: [] # type: ignore[reportUnknownLambdaType]
)
thickness_mm: Optional[int] = None
# Insulation thickness in mm — Summary §7.0 lodges this on the
# "Insulation Thickness" / "100 mm" line pair when a composite or
# retrofit insulation is recorded. None when the PDF omits the line.
insulation_thickness_mm: Optional[int] = None