mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-08-03 05:18:22 +00:00
Record exact engine↔Elmhurst convergence at SAP 80 for the Dovestone cert 🟪
A faithfully-built Elmhurst RdSAP10 (AP50 3.2, MVHR unit 500167, phantom secondary + open-flue cleared) reproduces the engine EXACTLY: worksheet 80 = engine 80, fabric heat loss 41.2 vs 41.6 W/K. The earlier 74 was Elmhurst data-entry fidelity (four artefacts), not calculator error. Refresh the saved worksheet/summary PDFs to the SAP-80 build; pin unchanged at 80. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DX8oAGsGkBHq3U4dsxYRzz
This commit is contained in:
parent
2f8c086310
commit
3fe4c3856a
3 changed files with 16 additions and 15 deletions
Binary file not shown.
Binary file not shown.
|
|
@ -1408,21 +1408,22 @@ _EXPECTATIONS: Final[tuple[RealCertExpectation, ...]] = (
|
|||
# and lifts SAP 67 → 80.
|
||||
#
|
||||
# Built in Elmhurst RdSAP10 on the lodged inputs (evidence saved:
|
||||
# elmhurst_summary.pdf / elmhurst_worksheet.pdf): Elmhurst worksheet SAP 74
|
||||
# (DHW 1839.64 kWh @ 4.24p = £78, heat pump 300%, distribution loss 1.5).
|
||||
# The +6 (80 vs 74) is the documented full-SAP→RdSAP methodology gap: the
|
||||
# engine uses the cert's MEASURED U-values (wall 0.19, floor 0.17) + MVHR
|
||||
# (PCDB 500167) → space heat 1039 kWh, where Elmhurst RdSAP uses age-band-M
|
||||
# proxies + a residual build AP50 (4.88 vs the cert's 3.2) → 1676 kWh. A
|
||||
# residual pulls the OTHER way (~-2): the engine's communal-DHW heat delivered
|
||||
# (2675 kWh = (64) 1698 × 1.05 × 1.50) exceeds the worksheet's (1839 = (64)
|
||||
# 1168 × 1.05 × 1.50). Investigated to root: this is NOT a bug — the engine
|
||||
# correctly applies the §4.3 distribution-loss factor; the delta is purely the
|
||||
# DHW energy-content demand (64), where the engine's 1698 kWh tracks the cert's
|
||||
# OWN lodged RHI water-heating (1909 kWh) far better than Elmhurst's reduced-
|
||||
# data 1168, and its £113 is closer to the cert's lodged £147 than Elmhurst's
|
||||
# £78. PINNED TO THE OBSERVED 80 — mapping deliberately untuned; the Elmhurst
|
||||
# delta is the full-SAP-measured vs RdSAP-reduced-data residual, NOT a bug.
|
||||
# elmhurst_summary.pdf / elmhurst_worksheet.pdf). A FAITHFULLY-built Elmhurst
|
||||
# reproduces the engine EXACTLY: worksheet SAP **80 = engine 80**. The
|
||||
# calculator is validated line-for-line — fabric heat loss 41.2 vs 41.6 W/K,
|
||||
# community DHW on fuel 41 @ 4.24p, ventilation matched once the cert's inputs
|
||||
# are keyed in.
|
||||
#
|
||||
# Reaching that faithful build meant correcting four data-entry artefacts that
|
||||
# the shared reusable assessment carried, each of which had suppressed the
|
||||
# accredited score below the engine (67→80 over the campaign): a phantom
|
||||
# secondary gas fire (SAP 603) → +5; the MVHR unit 500167 initially unset → +4;
|
||||
# air permeability AP50 keyed at 4.88 vs the cert's tested 3.2 → +1; and a
|
||||
# phantom "open flue attached to other heater" (1 vs the cert's 0) inflating
|
||||
# infiltration (8) → +5. With all four aligned to the certificate the two
|
||||
# engines converge on 80 — so the earlier apparent gaps were Elmhurst build
|
||||
# fidelity, NOT calculator error. PINNED TO THE OBSERVED 80 (lodged 81 B),
|
||||
# mapping deliberately untuned.
|
||||
RealCertExpectation(
|
||||
schema="SAP-Schema-18.0.0",
|
||||
sample="uprn_10094112770",
|
||||
|
|
|
|||
Loading…