mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-30 13:10:47 +00:00
test(worksheet): pin simulated case 50 — MVHR + dual-immersion all-electric
Adds the mapper-driven e2e cascade pin for "simulated case 50" (000565 semi, electric storage main SAP 402 + portable electric secondary + MVHR + whc-903 DUAL electric immersion + 160 L cylinder, Economy-7). Routes the Summary PDF through extractor + mapper + calculator like the other 000565 fixtures. Locks in two off-peak fixes this case ground-truthed: - the Table 13 HW high/low split applied to CO2/PE (commit39ae2cf0), and - the Table 12a Grid 2 MVHR fan fraction 0.71/0.58 (commitcd5113ab). All 11 SAP-result fields reconcile to the U985 worksheet EXACTLY, including the (272) rating CO2 2397.1237 — SAP 38.8426 (=39), cost £1317.0116, water 1668.0788 kWh, fans 315.6384 kWh. Summary mirrored to the tracked fixtures dir so the test doesn't depend on the unstaged `sap worksheets/` workspace. pyright strict gate not run locally (pyright not installed in this container). Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
parent
39ae2cf0c2
commit
4e2f2bdcc7
3 changed files with 131 additions and 0 deletions
BIN
backend/documents_parser/tests/fixtures/Summary_000565_case50.pdf
vendored
Normal file
BIN
backend/documents_parser/tests/fixtures/Summary_000565_case50.pdf
vendored
Normal file
Binary file not shown.
|
|
@ -0,0 +1,113 @@
|
|||
"""Mapper-driven cascade pin against the Elmhurst U985-0001-000565
|
||||
"simulated case 50" worksheet — an all-electric Economy-7 dwelling with
|
||||
MVHR + electric storage heaters + a DUAL-immersion hot-water cylinder.
|
||||
|
||||
Like 000565 / the _rr cases, this fixture does NOT hand-build the
|
||||
EpcPropertyData: it routes the Summary PDF through
|
||||
ElmhurstSiteNotesExtractor + from_elmhurst_site_notes so the SAP-result
|
||||
pin grid exercises the WHOLE extractor + mapper + calculator pipeline.
|
||||
|
||||
This case was hand-built (Khalim) to ground-truth the dual-immersion
|
||||
cylinder water-heating path, and it exercises two distinct off-peak
|
||||
tariff mechanics that the gas/standard-tariff fixtures don't reach:
|
||||
|
||||
- The Table 13 HW high-rate fraction for a whc-903 DUAL electric
|
||||
immersion (0.1009 high / 0.8991 low) — the COST (6.4878 p/kWh) AND
|
||||
the CO2/PE split ("Water heating - high/low rate cost", fixed in
|
||||
`_electric_immersion_hw_high_rate_fraction`).
|
||||
- The Table 12a Grid 2 fan fraction (0.71/0.58) for MVHR fan
|
||||
electricity (315.64 kWh, 100% MVHR per worksheet line 230a) — billed
|
||||
distinct from "all other uses" 0.90/0.80 (fixed by including the MVHR
|
||||
fan in `mev_kwh_for_cost_split`).
|
||||
|
||||
Unknown meter + dual electric immersion resolves to 7-hour off-peak via
|
||||
the §12 trigger. After both fixes the existing-dwelling rating reconciles
|
||||
to the U985 worksheet EXACTLY, including the (272) rating CO2.
|
||||
|
||||
Cert shape: 000565 semi shell, main = electric storage heaters (SAP 402,
|
||||
manual charge control), portable electric secondary (SAP 693), water
|
||||
heating from a whc-903 dual electric immersion + 160 L foam cylinder (no
|
||||
cylinder stat), MVHR (Vent Axia, PCDB 500140), one instantaneous electric
|
||||
shower, no PV, Economy-7.
|
||||
|
||||
Source: user-simulated PDFs at `sap worksheets/golden fixture debugging/
|
||||
simulated case 50/`. The Summary is mirrored into the tracked
|
||||
`backend/documents_parser/tests/fixtures/Summary_000565_case50.pdf` so the
|
||||
test runs without depending on the unstaged workspace.
|
||||
|
||||
Worksheet pin targets (U985-0001-000565 block 1 — existing dwelling SAP):
|
||||
- SAP rating 39 (258); continuous 38.8426; ECF 4.4252 (257)
|
||||
- Total fuel cost £1317.0116 (255)
|
||||
- Total CO2 2397.1237 kg/year (272)
|
||||
- Space heating 14318.4904 kWh/year ((98c))
|
||||
- Main 1 fuel 12170.7169 kWh/year (211)
|
||||
- Secondary fuel 2147.7736 kWh/year (215)
|
||||
- Hot water fuel 1668.0788 kWh/year (219)
|
||||
- Lighting 435.3204 kWh/year (232)
|
||||
- Pumps/fans 315.6384 kWh/year (231)
|
||||
|
||||
Per [[feedback-zero-error-strict]] + [[feedback-e2e-validation-
|
||||
philosophy]]: pins are abs=1e-4 against the worksheet PDF. The pin
|
||||
values live in `test_e2e_elmhurst_sap_score._FIXTURE_PINS`.
|
||||
"""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
import re
|
||||
import subprocess
|
||||
from pathlib import Path
|
||||
from typing import Final
|
||||
|
||||
from backend.documents_parser.elmhurst_extractor import ElmhurstSiteNotesExtractor
|
||||
from datatypes.epc.domain.epc_property_data import EpcPropertyData
|
||||
from datatypes.epc.domain.mapper import EpcPropertyDataMapper
|
||||
|
||||
# parents[0]=worksheet/, [1]=sap10_calculator/, [2]=domain/, [3]=tests/,
|
||||
# [4]=repo root.
|
||||
_SUMMARY_PDF: Final[Path] = (
|
||||
Path(__file__).resolve().parents[4]
|
||||
/ "backend" / "documents_parser" / "tests" / "fixtures"
|
||||
/ "Summary_000565_case50.pdf"
|
||||
)
|
||||
|
||||
|
||||
def _summary_pdf_to_textract_style_pages(pdf_path: Path) -> list[str]:
|
||||
"""Convert a Summary PDF into the per-page text format the
|
||||
ElmhurstSiteNotesExtractor expects (label\\nvalue sequences). Mirror
|
||||
of the helper in the other `_elmhurst_worksheet_*` fixtures.
|
||||
"""
|
||||
info = subprocess.run(
|
||||
["pdfinfo", str(pdf_path)], capture_output=True, text=True, check=True,
|
||||
).stdout
|
||||
m = re.search(r"Pages:\s+(\d+)", info)
|
||||
if m is None:
|
||||
raise RuntimeError(f"Could not parse page count from {pdf_path}")
|
||||
page_count = int(m.group(1))
|
||||
pages: list[str] = []
|
||||
for i in range(1, page_count + 1):
|
||||
layout = subprocess.run(
|
||||
[
|
||||
"pdftotext", "-layout", "-f", str(i), "-l", str(i),
|
||||
str(pdf_path), "-",
|
||||
],
|
||||
capture_output=True, text=True, check=True,
|
||||
).stdout
|
||||
tokens: list[str] = []
|
||||
for line in layout.splitlines():
|
||||
if not line.strip():
|
||||
tokens.append("")
|
||||
continue
|
||||
parts = [p for p in re.split(r"\s{2,}", line.strip()) if p]
|
||||
tokens.extend(parts)
|
||||
pages.append("\n".join(tokens))
|
||||
return pages
|
||||
|
||||
|
||||
def build_epc() -> EpcPropertyData:
|
||||
"""Route the simulated case-50 Summary through extractor + mapper.
|
||||
No hand-built EpcPropertyData — the extractor and mapper are part of
|
||||
the test target.
|
||||
"""
|
||||
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_PDF)
|
||||
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
|
||||
return EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
|
||||
|
|
@ -48,6 +48,7 @@ from tests.domain.sap10_calculator.worksheet import (
|
|||
_elmhurst_worksheet_001431_case6 as _w001431_case6,
|
||||
_elmhurst_worksheet_001431_case7 as _w001431_case7,
|
||||
_elmhurst_worksheet_001431_case20 as _w001431_case20,
|
||||
_elmhurst_worksheet_000565_case50 as _w000565_case50,
|
||||
_elmhurst_worksheet_000565_case52 as _w000565_case52,
|
||||
)
|
||||
from tests.domain.sap10_calculator.worksheet._elmhurst_fixtures import (
|
||||
|
|
@ -297,6 +298,22 @@ _FIXTURE_PINS: Final[dict[str, FixtureCascadePins]] = {
|
|||
lighting_kwh_per_yr=246.3083,
|
||||
pumps_fans_kwh_per_yr=0.0,
|
||||
),
|
||||
# Mapper-driven — Summary_000565_case50.pdf → extractor → mapper →
|
||||
# calculator. All-electric Economy-7: storage-heater main (SAP 402) +
|
||||
# MVHR + whc-903 DUAL electric immersion + 160 L cylinder. Exercises
|
||||
# the Table 13 HW high/low split (cost + CO2/PE) AND the Table 12a
|
||||
# Grid 2 MVHR fan fraction (0.71/0.58). Reconciles to the worksheet
|
||||
# EXACTLY after both off-peak fixes (incl. the (272) rating CO2).
|
||||
"000565_case50": FixtureCascadePins(
|
||||
sap_score=39, sap_score_continuous=38.8426, ecf=4.4252,
|
||||
total_fuel_cost_gbp=1317.0116, co2_kg_per_yr=2397.1237,
|
||||
space_heating_kwh_per_yr=14318.4904,
|
||||
main_heating_fuel_kwh_per_yr=12170.7169,
|
||||
secondary_heating_fuel_kwh_per_yr=2147.7736,
|
||||
hot_water_kwh_per_yr=1668.0788,
|
||||
lighting_kwh_per_yr=435.3204,
|
||||
pumps_fans_kwh_per_yr=315.6384,
|
||||
),
|
||||
# Mapper-driven — Summary_000565_case52.pdf → extractor → mapper →
|
||||
# calculator. Regular (non-combi) mains-gas boiler (SAP 102) + a
|
||||
# 160 L foam cylinder heated from the main (WHC 901), no cylinder
|
||||
|
|
@ -333,6 +350,7 @@ _FIXTURE_MODULES: Final[dict[str, ModuleType]] = {
|
|||
"001431_case6": _w001431_case6,
|
||||
"001431_case7": _w001431_case7,
|
||||
"001431_case20": _w001431_case20,
|
||||
"000565_case50": _w000565_case50,
|
||||
"000565_case52": _w000565_case52,
|
||||
}
|
||||
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue