language updates to heat pump recommendations
This commit is contained in:
parent
022bf6742c
commit
614f5f0c98
2 changed files with 14 additions and 10 deletions
|
|
@ -10,6 +10,8 @@ SOLAR_CONSUMPTION_PROPORTION = 0.5
|
|||
# Typically, each solar panel takes up around 3.4 m2 of roof space under RdSAP. This was been verified in Elmhurst
|
||||
RDSAP_AREA_PER_PANEL = 3.4
|
||||
|
||||
SOCIAL_TENURES = ["Rented (social)", "rental (social)"]
|
||||
|
||||
DESCRIPTIONS_TO_FUEL_TYPES = {
|
||||
"Air source heat pump, radiators, electric": {
|
||||
"fuel": "Electricity", "cop": AVERAGE_ASHP_EFFICIENCY / 100
|
||||
|
|
|
|||
|
|
@ -1,4 +1,5 @@
|
|||
import re
|
||||
import backend.app.assumptions as assumptions
|
||||
from recommendations.Costs import Costs, BOILER_UPGRADE_SCHEME_ASHP_VALUE
|
||||
from recommendations.recommendation_utils import (
|
||||
check_simulation_difference, override_costs, combine_recommendation_configs
|
||||
|
|
@ -484,11 +485,13 @@ class HeatingRecommender:
|
|||
# This is a map from the heating controls description to the description of the air source heat pump set up
|
||||
ashp_descriptions = {
|
||||
"Time and temperature zone control": (
|
||||
"Install an air source heat pump, and upgrade heating controls to Smart Thermostats, "
|
||||
"room sensors and smart radiator valves (time & temperature zone control)."
|
||||
f"Install a {ashp_size}KW air source heat pump, and upgrade heating controls to Smart Thermostats, "
|
||||
"room sensors and smart radiator valves (time & temperature zone control). Ensure you have an 18 or "
|
||||
"24 hour tariff"
|
||||
),
|
||||
"Programmer, TRVs and bypass": (
|
||||
"Install an air source heat pump, with programmer, TRVs and a Bypass valve."
|
||||
f"Install a {ashp_size}KW air source heat pump, with programmer, TRVs and a Bypass valve. Ensure you "
|
||||
"have an 18 or 24 hour tariff"
|
||||
),
|
||||
}
|
||||
|
||||
|
|
@ -505,7 +508,7 @@ class HeatingRecommender:
|
|||
ashp_costs_with_controls[key] += controls_rec[key]
|
||||
|
||||
if controls_rec is None:
|
||||
description = "Install a Mitsubish air source heat pump."
|
||||
description = f"Install a {ashp_size}KW Air source heat pump. Ensure you have an 18 or 24 hour tariff"
|
||||
elif already_installed:
|
||||
description = "The property already has an air source heat pump, no further action needed."
|
||||
else:
|
||||
|
|
@ -514,17 +517,16 @@ class HeatingRecommender:
|
|||
# If the property does not have existing cavity and loft insulation, we include a note that the cost
|
||||
# includes the boiler upgrade scheme and that the cavity and loft need to be treated, to ensure access
|
||||
# to the funding
|
||||
if not non_intrusive_recommendation:
|
||||
if not non_intrusive_recommendation and self.property.data["tenure"] not in assumptions.SOCIAL_TENURES:
|
||||
if has_cavity_or_loft_recommendations:
|
||||
description = description + (
|
||||
f" The cost includes the £"
|
||||
f"{BOILER_UPGRADE_SCHEME_ASHP_VALUE} boiler upgrade scheme grant. "
|
||||
f"You must ensure that the property has an insulated cavity and "
|
||||
f"270mm+ loft insulation to qualify for the grant"
|
||||
f" You must ensure that the property has an insulated cavity and "
|
||||
f"270mm+ loft insulation to qualify for the grant, to claim £"
|
||||
f"{BOILER_UPGRADE_SCHEME_ASHP_VALUE} of funding from the boiler upgrade scheme grant. "
|
||||
)
|
||||
else:
|
||||
description = description + (
|
||||
f" The cost includes the £{BOILER_UPGRADE_SCHEME_ASHP_VALUE} boiler upgrade scheme grant"
|
||||
f" £{BOILER_UPGRADE_SCHEME_ASHP_VALUE} of funding can be claimed from the boiler upgrade scheme"
|
||||
)
|
||||
|
||||