mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
another unit test covered
This commit is contained in:
parent
942f1958db
commit
76154c5172
2 changed files with 56 additions and 5 deletions
|
|
@ -19,6 +19,7 @@ class HeatingRecommender:
|
|||
self.heating_control_recommendations = []
|
||||
|
||||
self.has_electric_heating_description = self.property.main_heating["has_electric"]
|
||||
self.has_ashp = self.property.main_heating["has_air_source_heat_pump"]
|
||||
|
||||
def is_high_heat_retention_valid(self, ashp_only_heating_recommendation, measures):
|
||||
"""
|
||||
|
|
@ -31,8 +32,10 @@ class HeatingRecommender:
|
|||
|
||||
hhr_suitable = no_mains or self.has_electric_heating_description
|
||||
|
||||
# If there's already an ASHP in place, we don't recommend HHR
|
||||
|
||||
return (
|
||||
hhr_suitable and (not ashp_only_heating_recommendation) and
|
||||
hhr_suitable and (not ashp_only_heating_recommendation) and not self.has_ashp and
|
||||
("high_heat_retention_storage_heater" in measures)
|
||||
)
|
||||
|
||||
|
|
@ -86,7 +89,8 @@ class HeatingRecommender:
|
|||
non_gas_boiler
|
||||
) and
|
||||
(not ashp_only_heating_recommendation) and
|
||||
("boiler_upgrade" in measures)
|
||||
("boiler_upgrade" in measures) and
|
||||
(not self.has_ashp)
|
||||
)
|
||||
|
||||
return is_valid, has_gas_boiler
|
||||
|
|
@ -155,7 +159,11 @@ class HeatingRecommender:
|
|||
# In the future, we'll allow overrides, so that non-intrusive surveys can contradict these conditions
|
||||
# and either allow or prevent the recommendation of an air source heat pump
|
||||
|
||||
if self.property.is_ashp_valid(measures=measures) and non_invasive_ashp_recommendation["suitable"]:
|
||||
if (
|
||||
self.property.is_ashp_valid(measures=measures) and
|
||||
non_invasive_ashp_recommendation["suitable"] and
|
||||
not self.has_ashp
|
||||
):
|
||||
self.recommend_air_source_heat_pump(
|
||||
phase=phase,
|
||||
has_cavity_or_loft_recommendations=has_cavity_or_loft_recommendations,
|
||||
|
|
|
|||
|
|
@ -1024,6 +1024,48 @@ testing_examples = [
|
|||
],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"notes": "This is an end-terrace house, without mains gas connection, so all we recommend is HHR"
|
||||
},
|
||||
{
|
||||
"epc": {
|
||||
'lmk-key': '1281510829102015021321472533359578', 'address1': '6, Nags Head Lane', 'address2': 'Hargrave',
|
||||
'address3': None, 'postcode': 'NN9 6BJ', 'building-reference-number': 134423378,
|
||||
'current-energy-rating': 'F', 'potential-energy-rating': 'B', 'current-energy-efficiency': 38,
|
||||
'potential-energy-efficiency': 84, 'property-type': 'House', 'built-form': 'End-Terrace',
|
||||
'inspection-date': '2015-02-13', 'local-authority': 'E07000152', 'constituency': 'E14000648',
|
||||
'county': 'Northamptonshire', 'lodgement-date': '2015-02-13',
|
||||
'transaction-type': 'assessment for green deal', 'environment-impact-current': 45,
|
||||
'environment-impact-potential': 85, 'energy-consumption-current': 400, 'energy-consumption-potential': 96,
|
||||
'co2-emissions-current': 5.0, 'co2-emiss-curr-per-floor-area': 68, 'co2-emissions-potential': 1.2,
|
||||
'lighting-cost-current': 87, 'lighting-cost-potential': 48, 'heating-cost-current': 1094,
|
||||
'heating-cost-potential': 423, 'hot-water-cost-current': 240, 'hot-water-cost-potential': 144,
|
||||
'total-floor-area': 74.0, 'energy-tariff': 'Single', 'mains-gas-flag': 'N', 'floor-level': 'NODATA!',
|
||||
'flat-top-storey': None, 'flat-storey-count': None, 'main-heating-controls': 2204.0,
|
||||
'multi-glaze-proportion': 100.0, 'glazed-type': 'double glazing installed before 2002',
|
||||
'glazed-area': 'Normal', 'extension-count': 0, 'number-habitable-rooms': 5, 'number-heated-rooms': 5,
|
||||
'low-energy-lighting': 18, 'number-open-fireplaces': 0, 'hotwater-description': 'From main system',
|
||||
'hot-water-energy-eff': 'Poor', 'hot-water-env-eff': 'Good',
|
||||
'floor-description': 'Solid, no insulation (assumed)', 'floor-energy-eff': 'NO DATA!',
|
||||
'windows-description': 'Fully double glazed', 'windows-energy-eff': 'Average', 'windows-env-eff': 'Average',
|
||||
'walls-description': 'Solid brick, as built, no insulation (assumed)', 'walls-energy-eff': 'Poor',
|
||||
'walls-env-eff': 'Poor', 'secondheat-description': 'Room heaters, electric',
|
||||
'roof-description': 'Pitched, 300 mm loft insulation', 'roof-energy-eff': 'Very Good',
|
||||
'roof-env-eff': 'Very Good', 'mainheat-description': 'Air source heat pump, radiators, electric',
|
||||
'mainheat-energy-eff': 'Poor', 'mainheat-env-eff': 'Good',
|
||||
'mainheatcont-description': 'Programmer and room thermostat', 'mainheatc-energy-eff': 'Average',
|
||||
'mainheatc-env-eff': 'Average', 'lighting-description': 'Low energy lighting in 18% of fixed outlets',
|
||||
'lighting-energy-eff': 'Poor', 'lighting-env-eff': 'Poor', 'main-fuel': 'electricity (not community)',
|
||||
'wind-turbine-count': 0, 'heat-loss-corridor': 'NO DATA!', 'unheated-corridor-length': None,
|
||||
'floor-height': None, 'photo-supply': None, 'solar-water-heating-flag': 'N',
|
||||
'mechanical-ventilation': 'natural', 'address': '6, Nags Head Lane, Hargrave',
|
||||
'local-authority-label': 'East Northamptonshire', 'constituency-label': 'Corby',
|
||||
'posttown': 'WELLINGBOROUGH', 'construction-age-band': 'England and Wales: 1930-1949',
|
||||
'lodgement-datetime': '2015-02-13 21:47:25', 'tenure': 'rental (social)',
|
||||
'fixed-lighting-outlets-count': None, 'low-energy-fixed-light-count': None, 'uprn': 100031045596,
|
||||
'uprn-source': 'Address Matched', 'sheating-energy-eff': None, 'sheating-env-eff': None
|
||||
},
|
||||
"heating_recommendation_descriptions": [],
|
||||
"heating_controls_recommendation_descriptions": [],
|
||||
"notes": "This property already has an ashp. We don't recommend any heating upgrades"
|
||||
}
|
||||
]
|
||||
|
||||
|
|
@ -1081,7 +1123,8 @@ completed_descriptions = [
|
|||
"Boiler and radiators, dual fuel (mineral and wood)",
|
||||
"Boiler and radiators, coal",
|
||||
"Boiler and radiators, smokeless fuel",
|
||||
"Boiler and radiators, wood pellets"
|
||||
"Boiler and radiators, wood pellets",
|
||||
"Room heaters, dual fuel (mineral and wood)",
|
||||
]
|
||||
|
||||
portfolio = pd.read_excel(
|
||||
|
|
@ -1096,7 +1139,7 @@ portfolio["lodgement-datetime"] = portfolio["lodgement-datetime"].astype(str)
|
|||
print(portfolio["mainheat-description"].value_counts())
|
||||
|
||||
eg = portfolio[
|
||||
(portfolio["mainheat-description"] == "Room heaters, dual fuel (mineral and wood)")
|
||||
(portfolio["mainheat-description"] == "Air source heat pump, radiators, electric")
|
||||
].sample(1)
|
||||
eg = eg.squeeze().to_dict()
|
||||
print(eg)
|
||||
|
|
|
|||
Loading…
Add table