mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-07-12 13:29:04 +00:00
Merge pull request #1451 from Hestia-Homes/fix/sap-heating-optional-air-conditioning
Make nested SapHeating.has_fixed_air_conditioning optional across all RdSAP schemas
This commit is contained in:
commit
838668bfdb
7 changed files with 29 additions and 13 deletions
|
|
@ -44,7 +44,9 @@ class SapHeating:
|
|||
instantaneous_wwhrs: Optional[InstantaneousWwhrs]
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (already Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
# ADR-0028: cylinder_insulation_type is absent in 308/1000 17.0 certs.
|
||||
cylinder_insulation_type: Optional[int] = None
|
||||
cylinder_thermostat: Optional[str] = None
|
||||
|
|
|
|||
|
|
@ -44,7 +44,9 @@ class SapHeating:
|
|||
instantaneous_wwhrs: Optional[InstantaneousWwhrs]
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (also made Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
# ADR-0028: 325/1000 omit cylinder_insulation_type — default it.
|
||||
cylinder_insulation_type: Optional[int] = None
|
||||
cylinder_thermostat: Optional[str] = None
|
||||
|
|
@ -247,7 +249,7 @@ class RdSapSchema17_1:
|
|||
hot_water_cost_potential: CostAmount
|
||||
renewable_heat_incentive: RenewableHeatIncentive
|
||||
energy_consumption_current: int
|
||||
has_fixed_air_conditioning: str
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
multiple_glazed_proportion: int
|
||||
calculation_software_version: str
|
||||
energy_consumption_potential: int
|
||||
|
|
|
|||
|
|
@ -44,7 +44,9 @@ class SapHeating:
|
|||
instantaneous_wwhrs: Optional[InstantaneousWwhrs]
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (also made Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
cylinder_insulation_type: Optional[int] = None
|
||||
cylinder_thermostat: Optional[str] = None
|
||||
secondary_fuel_type: Optional[int] = None
|
||||
|
|
@ -266,7 +268,7 @@ class RdSapSchema18_0:
|
|||
hot_water_cost_potential: CostAmount
|
||||
renewable_heat_incentive: RenewableHeatIncentive
|
||||
energy_consumption_current: int
|
||||
has_fixed_air_conditioning: str
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
multiple_glazed_proportion: int
|
||||
calculation_software_version: str
|
||||
energy_consumption_potential: int
|
||||
|
|
|
|||
|
|
@ -44,7 +44,9 @@ class SapHeating:
|
|||
instantaneous_wwhrs: Optional[InstantaneousWwhrs]
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (also made Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
cylinder_insulation_type: Optional[int] = None
|
||||
cylinder_thermostat: Optional[str] = None
|
||||
secondary_fuel_type: Optional[int] = None
|
||||
|
|
@ -281,7 +283,7 @@ class RdSapSchema19_0:
|
|||
# 19.0-specific block, absent in 713/1000 — Optional + default.
|
||||
windows_transmission_details: Optional[WindowsTransmissionDetails] = None
|
||||
energy_consumption_current: int
|
||||
has_fixed_air_conditioning: str
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
multiple_glazed_proportion: int
|
||||
calculation_software_version: str
|
||||
energy_consumption_potential: int
|
||||
|
|
|
|||
|
|
@ -56,7 +56,9 @@ class SapHeating:
|
|||
instantaneous_wwhrs: Optional[InstantaneousWwhrs]
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (already Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
cylinder_insulation_type: Optional[int] = None
|
||||
cylinder_thermostat: Optional[str] = None
|
||||
secondary_fuel_type: Optional[int] = None
|
||||
|
|
|
|||
|
|
@ -63,7 +63,9 @@ class SapHeating:
|
|||
water_heating_fuel: int
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (also made Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
instantaneous_wwhrs: Optional[InstantaneousWwhrs] = None
|
||||
# Real-API certs carry shower_outlets as a list, not the synthetic
|
||||
# single-object form; list elements are normalised to the wrapped
|
||||
|
|
@ -459,7 +461,7 @@ class RdSapSchema21_0_0:
|
|||
windows_transmission_details: Optional[WindowsTransmissionDetails] = None
|
||||
cfl_fixed_lighting_bulbs_count: Optional[int] = None
|
||||
energy_consumption_current: int
|
||||
has_fixed_air_conditioning: str
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
multiple_glazed_proportion: int
|
||||
calculation_software_version: str
|
||||
energy_consumption_potential: int
|
||||
|
|
|
|||
|
|
@ -1,4 +1,4 @@
|
|||
from dataclasses import dataclass
|
||||
from dataclasses import dataclass, field
|
||||
from typing import List, Optional, Union
|
||||
|
||||
from .common import DescriptionV1, Measurement
|
||||
|
|
@ -64,7 +64,9 @@ class SapHeating:
|
|||
water_heating_fuel: int
|
||||
main_heating_details: List[MainHeatingDetail]
|
||||
immersion_heating_type: Union[int, str]
|
||||
has_fixed_air_conditioning: str
|
||||
# Nested duplicate of the outer schema's has_fixed_air_conditioning
|
||||
# (also made Optional below) — some certs omit it here too.
|
||||
has_fixed_air_conditioning: Optional[str] = None
|
||||
instantaneous_wwhrs: Optional[InstantaneousWwhrs] = None
|
||||
# Real-API certs carry shower_outlets as a list, not the synthetic single-object form;
|
||||
# accept both shapes so older fixtures keep parsing. List elements
|
||||
|
|
@ -510,7 +512,9 @@ class RdSapSchema21_0_1:
|
|||
renewable_heat_incentive: RenewableHeatIncentive
|
||||
draughtproofed_door_count: int
|
||||
energy_consumption_current: int
|
||||
has_fixed_air_conditioning: str
|
||||
# kw_only on just this field: the class isn't kw_only overall, and several
|
||||
# required fields (calculation_software_version etc.) already follow it.
|
||||
has_fixed_air_conditioning: Optional[str] = field(default=None, kw_only=True)
|
||||
calculation_software_version: str
|
||||
energy_consumption_potential: int
|
||||
environmental_impact_current: int
|
||||
|
|
|
|||
Loading…