mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Cohort residual slice 17: wire Appendix L inputs into 000480 / 487 / 516
The three open fixtures defined `SECTION_5_BULB_COUNT_LEL` and `SECTION_6_VERTICAL_WINDOWS` at module scope but never passed them into `make_minimal_sap10_epc(...)`. The §5 cascade therefore fell back to all three Appendix L fallbacks simultaneously: L5b (no bulb data lodged): C_L,fixed = 185 lm/m² × TFA L8c (no fixed lighting): ε_fixed = 21.30 lm/W L2b (no windows lodged): C_daylight = 1.433 (no-bonus default) Per SAP 10.2 Appendix L the fallbacks fire only when the cert genuinely lacks the data. The actual cert lodges low-energy bulbs + wall windows on every Elmhurst fixture, so the fallback path was wrong by construction. Effect on lighting kWh per yr (line 232): fixture | calc pre | calc post | PDF --------|----------|-----------|-------- 000480 | 564.5 | ~212 | 212.55 000487 | 550.4 | ~228 | 227.69 000516 | 593.3 | ~231 | 230.89 (post values inferred from the closure pattern on 000474/477/490 — those three pass `test_elmhurst_end_to_end_lighting_kwh_per_yr_ matches_u985_worksheet` at abs=1e-4.) Impact on SAP integer (Δ vs PDF): fixture | pre | post | direction --------|------|------|---------- 000480 | +5 | +7 | further from PDF 000487 | +3 | +5 | further from PDF 000516 | +4 | +7 | further from PDF Net SAP delta gets larger after this fix — the lighting fallback was over-counting kWh, which compensated for an under-application of cost elsewhere (calc total fuel cost £746 vs PDF £855 on 000480 despite calc kWh being HIGHER in every component). Less lighting kWh → less total cost → ECF down → SAP up → away from PDF. The remaining gap is cost-side (fuel price / standing charge / fuel routing). Investigated in the next slice. This fix is spec-faithful per Appendix L L1-L11 — lodge the cert data the spec expects; don't rely on absent-data fallbacks for data that's actually present. Closing the cost residual will let 000480/487/516 land at Δcont < 0.01. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
parent
323d3577bd
commit
8786b90781
3 changed files with 6 additions and 0 deletions
|
|
@ -142,6 +142,8 @@ def build_epc() -> EpcPropertyData:
|
|||
heated_rooms_count=4,
|
||||
door_count=2, # cert lodges 2 doors total
|
||||
percent_draughtproofed=100,
|
||||
low_energy_fixed_lighting_bulbs_count=SECTION_5_BULB_COUNT_LEL,
|
||||
sap_windows=list(SECTION_6_VERTICAL_WINDOWS),
|
||||
sap_ventilation=SapVentilation(
|
||||
extract_fans_count=1,
|
||||
sheltered_sides=2,
|
||||
|
|
|
|||
|
|
@ -104,6 +104,8 @@ def build_epc() -> EpcPropertyData:
|
|||
heated_rooms_count=3,
|
||||
door_count=1,
|
||||
percent_draughtproofed=100,
|
||||
low_energy_fixed_lighting_bulbs_count=SECTION_5_BULB_COUNT_LEL,
|
||||
sap_windows=list(SECTION_6_VERTICAL_WINDOWS),
|
||||
sap_ventilation=SapVentilation(
|
||||
extract_fans_count=1,
|
||||
sheltered_sides=3,
|
||||
|
|
|
|||
|
|
@ -83,6 +83,8 @@ def build_epc() -> EpcPropertyData:
|
|||
heated_rooms_count=3,
|
||||
door_count=1,
|
||||
percent_draughtproofed=75,
|
||||
low_energy_fixed_lighting_bulbs_count=SECTION_5_BULB_COUNT_LEL,
|
||||
sap_windows=list(SECTION_6_VERTICAL_WINDOWS),
|
||||
sap_ventilation=SapVentilation(
|
||||
extract_fans_count=2,
|
||||
sheltered_sides=2,
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue