mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Slice S0380.167: EES codes WEA/REA/OEA → electricity (electric storage 11-14 unblock)
Adds three Elmhurst EES (Energy Efficiency Standard) codes to `_ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE` so the mapper can derive the main heating fuel for electric storage / direct-acting certs whose Elmhurst Summary §14.0 does not lodge a "Main Heating Fuel Type" string (same pattern as the solid-fuel block above): "WEA": 30, # electric warm-air storage "REA": 30, # resistive electric (corpus electric 12 SAP 691) "OEA": 30, # other electric (corpus electric 13/14 SAP 701) All route to Table 32 standard-electricity code 30; the cascade resolves the actual price tier (high vs low rate) downstream via `_rdsap_tariff(epc)` keyed off `meter_type`. The corpus carries 4 electric-storage variants on the 18-hour tariff: electric 11 — WEA + SAP 515 (warm-air electric) electric 12 — REA + SAP 691 electric 13 — OEA + SAP 701 electric 14 — OEA + SAP 701 (differs from 13 by emitter / controls) Pre-slice all 4 raised `MissingMainFuelType` per S0380.132. Post-slice all 4 EXACT on first try across all 4 metrics: electric 11: ΔSAP_c +0.0000 Δcost +£0.0000 ΔCO2 −0.0000 ΔPE −0.0000 electric 12: ΔSAP_c +0.0000 Δcost +£0.0000 ΔCO2 −0.0000 ΔPE −0.0000 electric 13: ΔSAP_c +0.0000 Δcost −£0.0000 ΔCO2 +0.0000 ΔPE −0.0000 electric 14: ΔSAP_c +0.0000 Δcost −£0.0000 ΔCO2 +0.0000 ΔPE −0.0000 Closure on first try because the cascade was already wired for the electric-storage path (SAP 10.2 Table 4a codes 515 / 691 / 701, Table 4e Group 4 storage controls, Table 5a pump-gain wet-gate from S0380.160, S0380.144 secondary-fraction by sub-row); only the Elmhurst EES → fuel mapping was missing. Moves electric 11/12/13/14 out of `_BLOCKED_BY_MISSING_MAIN_FUEL_TYPE` into `_EXPECTATIONS` at ±0.0000. Blocked tier now: 11 variants (community heating × 5, no system, oil 2-6). Tests: - test_elmhurst_main_heating_ees_maps_electric_storage_codes_to_electricity - corpus pins: electric 11/12/13/14 expected residuals = ±0.0000 Cascade-OK tier: 30 variants (up from 25), all SAP / cost / CO2 / PE EXACT (< 1e-4) vs Elmhurst worksheet on every metric. Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
parent
1491899412
commit
a124c2bc68
3 changed files with 50 additions and 4 deletions
|
|
@ -415,6 +415,14 @@ _EXPECTATIONS: tuple[_CorpusExpectation, ...] = (
|
|||
_CorpusExpectation(variant='electric 7', block='11a', expected_sap_resid=-0.0000, expected_cost_resid_gbp=+0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=+0.0000),
|
||||
_CorpusExpectation(variant='electric 8', block='11a', expected_sap_resid=-0.0000, expected_cost_resid_gbp=-0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=-0.0000),
|
||||
_CorpusExpectation(variant='electric 9', block='11a', expected_sap_resid=+0.0000, expected_cost_resid_gbp=+0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=+0.0000),
|
||||
# Slice S0380.167 unblocked electric storage 11-14 via EES codes
|
||||
# WEA / REA / OEA → fuel code 30 (standard electricity). All 4 EXACT
|
||||
# on first try — the cascade was already wired for electric storage
|
||||
# paths.
|
||||
_CorpusExpectation(variant='electric 11', block='11a', expected_sap_resid=+0.0000, expected_cost_resid_gbp=+0.0000, expected_co2_resid_kg=-0.0000, expected_pe_resid_kwh=-0.0000),
|
||||
_CorpusExpectation(variant='electric 12', block='11a', expected_sap_resid=+0.0000, expected_cost_resid_gbp=+0.0000, expected_co2_resid_kg=-0.0000, expected_pe_resid_kwh=-0.0000),
|
||||
_CorpusExpectation(variant='electric 13', block='11a', expected_sap_resid=+0.0000, expected_cost_resid_gbp=-0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=-0.0000),
|
||||
_CorpusExpectation(variant='electric 14', block='11a', expected_sap_resid=+0.0000, expected_cost_resid_gbp=-0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=-0.0000),
|
||||
_CorpusExpectation(variant='gshp', block='11a', expected_sap_resid=-0.0000, expected_cost_resid_gbp=-0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=+0.0000),
|
||||
_CorpusExpectation(variant='oil 1', block='11a', expected_sap_resid=-0.0000, expected_cost_resid_gbp=-0.0000, expected_co2_resid_kg=+0.0000, expected_pe_resid_kwh=+0.0000),
|
||||
_CorpusExpectation(variant='oil pcdb 1', block='11a', expected_sap_resid=+0.0000, expected_cost_resid_gbp=+0.0000, expected_co2_resid_kg=-0.0000, expected_pe_resid_kwh=+0.0000),
|
||||
|
|
@ -471,10 +479,6 @@ _BLOCKED_BY_MISSING_MAIN_FUEL_TYPE: tuple[str, ...] = (
|
|||
'community heating 3',
|
||||
'community heating 4',
|
||||
'community heating 6',
|
||||
'electric 11',
|
||||
'electric 12',
|
||||
'electric 13',
|
||||
'electric 14',
|
||||
'no system',
|
||||
'oil 2',
|
||||
'oil 3',
|
||||
|
|
|
|||
|
|
@ -4170,6 +4170,22 @@ _ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE: Final[dict[str, int]] = {
|
|||
# Wood Logs — Table 32 code 20 (4.23 / 0.028 / 1.046). Corpus
|
||||
# variant solid fuel 11 (SAP 634).
|
||||
"RWN": 20,
|
||||
# Electric storage / direct-acting main heating systems — Table 32
|
||||
# code 30 (standard electricity; tariff resolved separately from
|
||||
# `meter_type` per `_rdsap_tariff`). Three EES codes share the
|
||||
# electricity fuel route:
|
||||
# WEA — corpus variant electric 11 (SAP 515 = electric warm-air)
|
||||
# REA — corpus variant electric 12 (SAP 691)
|
||||
# OEA — corpus variants electric 13 + 14 (SAP 701)
|
||||
# The §14.0 "Fuel Type" field is absent on these certs (same
|
||||
# lodging pattern as the solid-fuel block above); the EES code is
|
||||
# the only fuel discriminator and unambiguously identifies electric
|
||||
# storage main heating. Fuel cost / CO2 / PE billed via Table 32
|
||||
# standard-electricity codes (30 high-rate, 31/33/35/40 low-rate
|
||||
# per tariff).
|
||||
"WEA": 30,
|
||||
"REA": 30,
|
||||
"OEA": 30,
|
||||
}
|
||||
|
||||
|
||||
|
|
|
|||
|
|
@ -1845,6 +1845,32 @@ def test_section_12_4_4_summer_immersion_applies_to_back_boiler_combos() -> None
|
|||
) is False
|
||||
|
||||
|
||||
def test_elmhurst_main_heating_ees_maps_electric_storage_codes_to_electricity() -> None:
|
||||
# Arrange — Elmhurst Summary §14.0 lodges a 3-letter "Main Heating
|
||||
# EES Code" alongside the Table 4a "Main Heating SAP Code" but does
|
||||
# NOT lodge a "Fuel Type" string for electric storage main heating
|
||||
# systems (same pattern as solid-fuel main heating). The mapper's
|
||||
# EES → fuel-code dict is the only path to derive the fuel.
|
||||
#
|
||||
# The corpus carries 4 electric storage variants (electric 11..14)
|
||||
# spanning EES codes WEA, REA, OEA + SAP codes 515, 691, 701. All
|
||||
# bill electricity at the lodged tariff (`meter_type='18 Hour'` for
|
||||
# the entire corpus); Table 32 standard-electricity code 30 is the
|
||||
# canonical base fuel — the cascade resolves the actual price tier
|
||||
# (high vs low rate) downstream via `_rdsap_tariff`.
|
||||
|
||||
from datatypes.epc.domain.mapper import (
|
||||
_ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE, # pyright: ignore[reportPrivateUsage]
|
||||
)
|
||||
|
||||
# Act / Assert — all 3 electric-storage EES codes route to
|
||||
# standard-electricity Table 32 code 30.
|
||||
for ees_code in ("WEA", "REA", "OEA"):
|
||||
assert _ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE[ees_code] == 30, (
|
||||
f"EES code {ees_code} should map to electricity (code 30)"
|
||||
)
|
||||
|
||||
|
||||
def test_elmhurst_main_fuel_to_sap10_maps_bulk_lpg_to_api_code_27() -> None:
|
||||
# Arrange — Elmhurst Summary §14.0 / §15.0 lodges "Bulk LPG" as the
|
||||
# fuel type for PCDB LPG-combi certs (corpus variant pcdb 3 lodges
|
||||
|
|
|
|||
Loading…