diff --git a/etl/customers/aiha/xml_extraction.py b/etl/customers/aiha/xml_extraction.py index d193c91e..531b6752 100644 --- a/etl/customers/aiha/xml_extraction.py +++ b/etl/customers/aiha/xml_extraction.py @@ -102,8 +102,6 @@ def main(): # TODO # - AIH001-03 has a loft that is inaccessible - ask Chenai about why this property didn't have access to the loft # [Can't remember, not clear - Chenai will check] - # - AIH001-04 why couldn't the cylinder be accessed? - treating this could get to the EPC C - # - Potential measure - search for the cylinder and insulate it # - AIH001-08 and AIH001-09, check if it's freehold - could solar work as both of these units are part of the same # buulding [Question for Lewis & Kevin] # - AIH001-09 - Is it not possible to install a loft hatch? [IT IS NOT, NO ACCESS - would need to accessed from @@ -111,9 +109,9 @@ def main(): # - AIH001-09 - Is there definitely an immersion water heater? Is this definitely the case for the other units? # [Question for Lewis & Kevin] - [YES - ASHP!!!!] - # TODO: Need AIH001-02 9C Clapton Common # TODO: Check which properties are in a conservation area # TODO: AIH001-16 - Is the loft insulation suitable (already has 100mm in the RIR) + # TODO: Adjust Archetype 14 homes to exclude double glazing? Or should we exclude entirely recommended_measures = [ { @@ -376,6 +374,8 @@ def main(): "floor_area": 63.59 + 12.31, # Based on area of main building and 1st extension "sap_points": 8, "ending_sap": 70, + "notes": "Loft is inaccessible from this unit - would need to be accessed from the other unit, " + "which is also owned by AIHA" } ], "notes": "This property is a house split into 2 flats. We can install a PV array for both units (one array" @@ -419,31 +419,31 @@ def main(): "sap_points": 3, "ending_sap": 49, }, - { - "measure": "Solar PV", - "description": "3.2kWp Solar PV system", - "config": [ - { - "size": "3.2W", - "orientation": "East", - "elavation": 30, - "overshading": "Little or none", - } - ], - "sap_points": 9, - "ending_sap": 58 - }, + # { + # "measure": "Solar PV", + # "description": "3.2kWp Solar PV system", + # "config": [ + # { + # "size": "3.2W", + # "orientation": "East", + # "elavation": 30, + # "overshading": "Little or none", + # } + # ], + # "sap_points": 9, + # "ending_sap": 58 + # }, { "measure": "Air Source Heat Pump", "description": "Ecoforest ecoAIR EVI 4-20 20kW air source heat pump (+TTZC)", "sap_points": 15, - "ending_sap": 73 + "ending_sap": 65 }, { "measure": "Tariff Review", "description": "Switch to 24-hour tariff", "sap_points": 15, - "ending_sap": 88 + "ending_sap": 80 } ] }, @@ -740,6 +740,90 @@ def main(): "ending_sap": 74, } ] + }, + { + "survey_key": "AIH001-SIMULATED-01", + "elmhurst_reference": "000020", + "starting_sap": None, + "recommended_measures": [ + { + "measure": "Internal Wall Insulation", + "description": "100mm internal wall insulation", + "hlp": (22.35 * 3.24) + (22.13 * 2.53), + "sap_points": 8, + "ending_sap": 52, + }, + { + "measure": "Cavity Wall Insulation", + "description": "CWI to rdSAP default standard", + "hlp": (2.68 * 2.39) + (5.93 * 2.63) + (6.13 * 2.39), # 1st & 2nd extension + "sap_points": 1, + "ending_sap": 53, + }, + { + "measure": "Ventilation", + "description": "2x DMEV fans", + "sap_points": 0, + "ending_sap": 53, + }, + { + "measure": "TTZC", + "description": "Smart Thermostat", + "sap_points": 3, + "ending_sap": 56, + }, + { + "measure": "Solar PV", + "description": "1.6kWp Solar PV system", + "config": [ + { + "size": "1.6W", + "orientation": "South-East", + "elavation": 30, + "overshading": "None or little", + } + ], + "sap_points": 6, + "ending_sap": 62 + }, + { + "measure": "Loft Insulation", + "description": "300mm loft insulation", + "floor_area": 63.59 + 12.31, # Based on area of main building and 1st extension + "sap_points": 8, + "ending_sap": 70, + "notes": "Loft is inaccessible from this unit - would need to be accessed from the other unit, " + "which is also owned by AIHA" + } + ], + "notes": "This was cloned from 80A. There is no existing data for 80B" + }, + { + "survey_key": "AIH001-SIMULATED-05", + "starting_sap": 68, + "recommended_measures": [ + { + "measure": "Loft Insulation", + "description": "300mm loft insulation", + "floor_area": 42.5, + "sap_points": 1, + "ending_sap": 69, + }, + { + "measure": "Solar PV", + "description": "3.2kWp Solar PV system", + "config": [ + { + "size": "3.2W", + "orientation": "North-East", + "elavation": 30, + "overshading": "None or little", + } + ], + "sap_points": 8, + "ending_sap": 77, + } + ] } ]