Slice S0380.6: surface full §15.1 Hot Water Cylinder block — Summary HW exact

Closes the entire §15.1 Hot Water Cylinder lodging end-to-end and
collapses cert 0380's Summary path to the API path at the documented
HP-cohort spec-precision floor: SAP **88.5698 (Δ +0.0594)** — exactly
matching the API path's spec-floor closure. `hot_water_kwh_per_yr`
hits **878.0519** vs worksheet (64) 1502.16 ÷ (216) HW eff 1.7107 =
**878.05** — exact match at 1e-4.

Four §15.1 fields surfaced together (the cascade requires all four in
combination to compute the worksheet-correct HP HW path):

1. `cylinder_size_label` (Summary "Medium" → SAP10 cascade enum 3 =
   160 L per `_CYLINDER_SIZE_CODE_TO_LITRES`)
2. `cylinder_insulation_label` (Summary "Foam" → cascade enum 1 =
   factory, per SAP 10.2 Table 2 Note 2)
3. `cylinder_insulation_thickness_mm` (Summary "50 mm" → 50)
4. `cylinder_thermostat` (Summary "Yes" → bool True → mapper emits 'Y'
   for the cascade's `sh.cylinder_thermostat == "Y"` string compare)

Why all four were required:

- `_cylinder_storage_loss_override` in `cert_to_inputs.py:2238-2253`
  gates on `cylinder_size`, `cylinder_insulation_type ==
  _CYLINDER_INSULATION_TYPE_FACTORY (1)`, AND
  `cylinder_insulation_thickness_mm`. Missing any → no override →
  zero storage loss (62)m miscalculated.
- `cylinder_thermostat` keys the SAP 10.2 Table 2b temperature factor
  (53): with-stat 0.5400 vs no-stat ~0.9 → without 'Y' storage loss
  over-counts by ~300 kWh/yr (the precise diff between the bundled-
  fields-only attempt at SAP 86.5 vs the fully-bundled attempt at
  SAP 88.57).

Three-layer end-to-end change:

1. `datatypes/epc/surveys/elmhurst_site_notes.py` — add four
   defaulted `WaterHeating` fields (placed in the defaulted block;
   existing fixtures that omit §15.1 still construct unchanged).
2. `backend/documents_parser/elmhurst_extractor.py` — extend
   `_extract_water_heating` to read the §15.1 block via
   `_section_lines("15.1 Hot Water Cylinder", "15.2 Community Hot
   Water")` + `_local_val`. Section-scoping is required because the
   "Insulation Thickness" label collides with §7 Walls / §8 Roofs /
   §9 Floors lodgings on the same Summary PDF (cert 0380 has §7
   "Insulation Thickness 100 mm" for the FE wall — the global
   `_next_val` would return the wrong value).
3. `datatypes/epc/domain/mapper.py` — add
   `_elmhurst_cylinder_size_code` + `_elmhurst_cylinder_insulation_code`
   label-to-enum helpers; replace the broken
   `cylinder_size = water_heating.water_heating_code` (which was
   passing the §15 "Water Heating Code" string "HWP" into the
   numeric `cylinder_size` field, defeating the cascade) with the
   real `cylinder_size_label`-derived enum.

Pre-Slice 6, the Summary path was producing `cylinder_size='HWP'`
which `_int_or_none` reduced to None, silently routing the cascade
off the HP-with-cylinder HW path entirely. Surfacing the §15.1
block in full lets `_heat_pump_apm_efficiencies` use the spec-
correct HW efficiency (1.7107) and `_cylinder_storage_loss_override`
contribute the spec-correct (56) 435 kWh/yr storage loss.

Pyright net-zero across all four edited files:
  datatypes/epc/domain/mapper.py:                32 (baseline)
  datatypes/epc/surveys/elmhurst_site_notes.py:   0
  backend/documents_parser/elmhurst_extractor.py: 0
  backend/documents_parser/tests/test_summary_pdf_mapper_chain.py: 0

Regression suite: 674 pass + 11 fail (vs handover baseline 669 + 10
— net +5 pass for the new GREEN unit tests S0380.2..S0380.6; the +1
fail vs baseline is still S0380.1's chain test which pins at 1e-4 vs
worksheet 88.5104 and now lands at Δ +0.0594, the same Appendix N3.6
PSR-interpolation precision floor that the API path closes to and
that the cohort's 7 ASHP fixtures already track at ±0.07).

Tolerance disposition: the +0.0594 residual is identical to the
cohort's documented HP-path precision floor. Closing further requires
work on the calculator's Appendix N3.6 PSR interpolation step
(boilers already match worksheet at 1e-4 via the same cascade —
ground-truthed in closed-boiler precedents 001479, 0330), not on
the Summary mapper. The S0380.1 chain test should be re-pinned to
the ±0.07 ASHP-cohort tolerance in the next slice — same disposition
the API-path cohort received in slice 102f (commit c0086660).

Spec refs:
- SAP 10.2 §4 Table 2 (PDF p.135) — cylinder storage loss factor
  for foam-insulated cylinders (51) keyed on insulation thickness.
- SAP 10.2 §4 Table 2a (PDF p.135) — cylinder volume factor (52).
- SAP 10.2 §4 Table 2b (PDF p.135) — cylinder temperature factor
  (53) keyed on cylinder thermostat + separately-timed DHW.
- SAP 10.2 Appendix N3.7(a) (PDF p.6097) — HP HW in-use factor
  cylinder-criteria, footnote 53 (cert HX area unknown for Open EPC
  schema → criteria fail → 0.60 in-use factor; the worksheet's
  closed HW path uses this same factor).
- Cert 0380 worksheet `dr87-0001-000899.pdf` lodgings:
  (47) Cylinder Volume 160.00 L; "Cylinder Insulation Type Foam";
  "Cylinder Insulation Thickness 50 mm"; "Cylinder Stat Yes";
  (51)..(56) cylinder storage loss chain; (64) HW output 1502.16;
  (216) HW efficiency 171.0746%.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
Khalim Conn-Kowlessar 2026-05-27 20:18:31 +00:00 committed by Jun-te Kim
parent 9faff3e122
commit c30b4fcdc8
4 changed files with 149 additions and 4 deletions

View file

@ -1062,11 +1062,46 @@ class ElmhurstSiteNotesExtractor:
)
def _extract_water_heating(self) -> WaterHeating:
# §15.1 lodgings — Summary writes these only when a cylinder
# is present. The §15.1 block uses labels ("Cylinder Size",
# "Insulated", "Insulation Thickness") that collide with
# global occurrences elsewhere ("Insulation Thickness" also
# appears in §7 Walls / §8 Roofs); scope the lookups via
# `_local_val` against the §15.1..§15.2 slice to disambiguate.
cylinder_lines = self._section_lines(
"15.1 Hot Water Cylinder", "15.2 Community Hot Water",
)
cylinder_size_label = self._local_val(
cylinder_lines, "Cylinder Size",
)
cylinder_insulation_label = self._local_val(
cylinder_lines, "Insulated",
)
cylinder_ins_thickness_raw = self._local_val(
cylinder_lines, "Insulation Thickness",
)
cylinder_insulation_thickness_mm: Optional[int] = None
if cylinder_ins_thickness_raw:
first = cylinder_ins_thickness_raw.split()[0]
if first.isdigit():
cylinder_insulation_thickness_mm = int(first)
cylinder_thermostat_raw = self._local_val(
cylinder_lines, "Cylinder Thermostat",
)
cylinder_thermostat: Optional[bool] = (
cylinder_thermostat_raw.strip().lower() == "yes"
if cylinder_thermostat_raw is not None
else None
)
return WaterHeating(
water_heating_code=self._str_val("Water Heating Code"),
water_heating_sap_code=self._int_val("Water Heating SapCode"),
water_heating_fuel_type=self._str_val("Water Heating Fuel Type"),
hot_water_cylinder_present=self._bool_val("Hot Water Cylinder Present"),
cylinder_size_label=cylinder_size_label,
cylinder_insulation_label=cylinder_insulation_label,
cylinder_insulation_thickness_mm=cylinder_insulation_thickness_mm,
cylinder_thermostat=cylinder_thermostat,
)
def _extract_baths_and_showers(self) -> BathsAndShowers:

View file

@ -587,6 +587,39 @@ def test_summary_0380_surfaces_insulated_door_u_value_1_2() -> None:
assert abs(epc.insulated_door_u_value - 1.2) < 1e-6
def test_summary_0380_cylinder_block_surfaces_full_15_1_lodging() -> None:
# Arrange — cert 0380's Summary §15.1 Hot Water Cylinder block
# lodges (L 340-347):
# Cylinder Size Medium
# Insulated Foam
# Insulation Thickness 50 mm
# Cylinder Thermostat Yes
# The dr87 worksheet pins these as:
# (47) Cylinder Volume 160.00 L → cascade enum 3
# "Cylinder Insulation Type Foam" → cascade enum 1 (factory)
# "Cylinder Insulation Thickness 50 mm" → 50
# "Cylinder Stat Yes" → 'Y'
# Worksheet (51) 0.0152 × (52) 0.9086 × (53) 0.5400 × (47) 160 ÷ 1000
# = daily storage loss 1.193 kWh/day → (56) annual ~435 kWh — exact
# only when ALL FOUR fields are surfaced together: insulation_type
# + thickness key the Table 2 loss factor (51), volume keys (52),
# and cylinder_thermostat keys the Table 2b temperature factor (53).
# Without cylinder_thermostat='Y' the cascade uses the no-stat
# temperature factor (~0.9 instead of 0.54) and HW storage loss
# over-counts by ~300 kWh/yr.
pages = _summary_pdf_to_textract_style_pages(_SUMMARY_000899_PDF)
site_notes = ElmhurstSiteNotesExtractor(pages).extract()
# Act
epc = EpcPropertyDataMapper.from_elmhurst_site_notes(site_notes)
# Assert
assert epc.sap_heating.cylinder_size == 3
assert epc.sap_heating.cylinder_insulation_type == 1
assert epc.sap_heating.cylinder_insulation_thickness_mm == 50
assert epc.sap_heating.cylinder_thermostat == "Y"
def test_summary_0380_full_chain_sap_matches_worksheet_pdf_exactly() -> None:
# Arrange — cert 0380-2471-3250-2596-8761 (Summary_000899.pdf /
# dr87-0001-000899.pdf) is the first heat-pump cert under per-cert

View file

@ -3370,6 +3370,53 @@ _ELMHURST_GAS_BOILER_FUEL_TYPES: frozenset[str] = frozenset({
})
# Elmhurst Summary §15.1 "Cylinder Size" labels mapped to the SAP10
# cascade enum that `domain/sap10_calculator/rdsap/cert_to_inputs.py`
# `_CYLINDER_SIZE_CODE_TO_LITRES` keys ({3: 160.0, 4: 210.0}). Only the
# "Medium" lodging is exercised by the cohort (cert 0380); other size
# labels (Small / Large / Very Large) are deferred until a fixture
# exercises them.
_ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10: Dict[str, int] = {
"Medium": 3,
}
# Elmhurst Summary §15.1 "Insulated" labels mapped to the SAP10
# `cylinder_insulation_type` cascade enum. Cascade enum 1
# (factory) is exercised by the cohort (cert 0380 lodges "Foam",
# which SAP 10.2 Table 2 Note 2 treats as factory-applied PU foam).
# Other labels (Loose Jacket, None) are deferred until a fixture
# exercises them.
_ELMHURST_CYLINDER_INSULATION_LABEL_TO_SAP10: Dict[str, int] = {
"Foam": 1,
}
def _elmhurst_cylinder_size_code(
cylinder_size_label: Optional[str], cylinder_present: bool,
) -> Optional[int]:
"""Map an Elmhurst §15.1 "Cylinder Size" label to the SAP10
cascade enum. Returns None when no cylinder is present or the
label is missing/unknown the cascade's
`_int_or_none(cylinder_size) None` then routes the cert off the
Table 2/2a/2b storage-loss path (correct for combis / instantaneous
HW; wrong for HP-with-cylinder certs until a label is mapped)."""
if not cylinder_present or cylinder_size_label is None:
return None
return _ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10.get(cylinder_size_label)
def _elmhurst_cylinder_insulation_code(
cylinder_insulation_label: Optional[str], cylinder_present: bool,
) -> Optional[int]:
"""Map an Elmhurst §15.1 "Insulated" label to the SAP10
`cylinder_insulation_type` cascade enum. Returns None when no
cylinder is present or the label is missing/unknown."""
if not cylinder_present or cylinder_insulation_label is None:
return None
return _ELMHURST_CYLINDER_INSULATION_LABEL_TO_SAP10.get(cylinder_insulation_label)
def _elmhurst_main_heating_category(
mh: ElmhurstMainHeating, pcdb_index: Optional[int]
) -> Optional[int]:
@ -3454,10 +3501,27 @@ def _map_elmhurst_sap_heating(survey: ElmhurstSiteNotes) -> SapHeating:
],
has_fixed_air_conditioning=survey.ventilation.fixed_space_cooling,
shower_outlets=shower_outlets,
cylinder_size=(
None
if not survey.water_heating.hot_water_cylinder_present
else survey.water_heating.water_heating_code
cylinder_size=_elmhurst_cylinder_size_code(
survey.water_heating.cylinder_size_label,
survey.water_heating.hot_water_cylinder_present,
),
cylinder_insulation_type=_elmhurst_cylinder_insulation_code(
survey.water_heating.cylinder_insulation_label,
survey.water_heating.hot_water_cylinder_present,
),
cylinder_insulation_thickness_mm=(
survey.water_heating.cylinder_insulation_thickness_mm
if survey.water_heating.hot_water_cylinder_present
else None
),
# Cascade reads `cylinder_thermostat == "Y"` (string compare) per
# `cert_to_inputs.py:2252` / `:2218`. Map the bool to the Y/N
# string the cascade expects; None when no cylinder is present.
cylinder_thermostat=(
("Y" if survey.water_heating.cylinder_thermostat else "N")
if survey.water_heating.hot_water_cylinder_present
and survey.water_heating.cylinder_thermostat is not None
else None
),
water_heating_code=survey.water_heating.water_heating_sap_code,
water_heating_fuel=water_heating_fuel,

View file

@ -219,6 +219,19 @@ class WaterHeating:
water_heating_sap_code: int
water_heating_fuel_type: str
hot_water_cylinder_present: bool
# §15.1 "Cylinder Size" lodging, e.g. "Medium" (corresponds to
# cascade enum 3 → 160 L per `_CYLINDER_SIZE_CODE_TO_LITRES`).
# None when no cylinder is present or the line is absent.
cylinder_size_label: Optional[str] = None
# §15.1 "Insulated" lodging, e.g. "Foam" / "Loose Jacket". The
# cascade enum 1 (factory) is used for Foam per SAP 10.2 Table 2
# Note 2. None when no cylinder is present or the line is absent.
cylinder_insulation_label: Optional[str] = None
# §15.1 "Insulation Thickness" lodging in mm (an integer or None).
cylinder_insulation_thickness_mm: Optional[int] = None
# §15.1 "Cylinder Thermostat" lodging (Yes / No). False or absent
# keeps the cascade's no-thermostat Table 2b temperature factor.
cylinder_thermostat: Optional[bool] = None