docs: handover post S0380.146..147
Captures the two slices that closed oil 1 from +2.66 → +1.18 SAP via
Table 3 primary-loss extension (.146) + Appendix D §D2.1 (2) Equation
D1 wiring for non-PCDB Table 4b boilers (.147). Highlights the user
directive that surfaced this session ("BRE/Elmhurst software follows
spec exactly; no special non-spec handling") and the resulting pin
shifts on cert 0240 + 6035 (combi-no-cylinder golden fixtures
re-pinned per spec correctness).
Ranks next-slice candidates: oil 1 Table 4f auxiliary energy (~+0.4
SAP closure remaining), electric 5 -1.43 regressed by .145, solid
fuel 2/3 anthracite outliers, community heating + electric storage
unblocking.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
parent
54ed142512
commit
c9c418be64
1 changed files with 255 additions and 0 deletions
255
domain/sap10_calculator/docs/HANDOVER_POST_S0380_147.md
Normal file
255
domain/sap10_calculator/docs/HANDOVER_POST_S0380_147.md
Normal file
|
|
@ -0,0 +1,255 @@
|
|||
# Handover — post Slices S0380.146..147
|
||||
|
||||
Branch: `feature/per-cert-mapper-validation`. **HEAD `7dceeff2`**.
|
||||
Predecessor: [`HANDOVER_POST_S0380_145.md`](HANDOVER_POST_S0380_145.md).
|
||||
|
||||
## TL;DR
|
||||
|
||||
Two slices landed on top of `1636cfbc` (handover commit). Both close
|
||||
non-PCDB Table 4b boiler gaps that combined to drive the oil 1
|
||||
residual. Oil 1 SAP +2.66 → +1.18, with HW fuel cascade now exact at
|
||||
worksheet (219) 3638.99 kWh/yr (Eq D1 monthly back-solve verified
|
||||
Jan 81.83 / May 79.94 / Jun-Sep 72 / Dec 81.86 against worksheet).
|
||||
|
||||
| Slice | Commit | Scope |
|
||||
|---|---|---|
|
||||
| S0380.146 | `bd193e06` | SAP 10.2 Table 3 row 1 — extend `_primary_loss_applies` Elmhurst-path fallback for Table 4b non-PCDB regular boilers + cylinder. New `_TABLE_4B_COMBI_OR_CPSU_CODES` zero-loss exclusion set per Table 3. Oil 1 (59) annual ≈ 510 kWh/yr matches worksheet. |
|
||||
| **S0380.147** | **`7dceeff2`** | **SAP 10.2 Appendix D §D2.1 (2) Equation D1 — wire monthly (winter, summer) cascade for non-PCDB Table 4b boilers. New `tables/table_4b.py` carries 41-row (winter, summer) dict verbatim from spec PDF p.168. `_apply_water_efficiency` parameter refactored to explicit `eq_d1_winter_summer_pct: Optional[tuple[float, float]]`. Call site resolves: PCDB → Table 4b fallback (when WHC=901). §9.4.11 -5pp interlock symmetric on both columns. Oil 1 HW fuel exact (3638.99 ≡ worksheet). Cert 0240 + 6035 golden re-pinned (combi-no-cylinder now uses spec-correct Eq D1).** |
|
||||
|
||||
Extended handover suite at HEAD: **890 pass, 0 fail.** Pyright net-zero
|
||||
(44 = 44).
|
||||
|
||||
## Critical user directive discovered this session
|
||||
|
||||
> "The software doesnt gave special non spec handling"
|
||||
|
||||
The BRE-approved Elmhurst lodging software follows spec exactly. When a
|
||||
spec-correct fix shifts a cohort cert pin, the pre-fix near-zero state
|
||||
was masking offsetting cascade gaps — NOT a deliberate non-spec rule.
|
||||
Don't add empirical "only fire when X is lodged" gates to keep certs
|
||||
happy. Apply spec uniformly + re-pin + document.
|
||||
|
||||
This is captured in new memory
|
||||
[`feedback-software-no-special-handling`](../../../home/vscode/.claude/projects/-workspaces-model/memory/feedback_software_no_special_handling.md).
|
||||
|
||||
The initial S0380.147 implementation gated the new Table 4b Eq D1
|
||||
branch on cylinder presence to avoid shifting cert 0240 + 6035 (combi-
|
||||
no-cylinder). User pushed back; the cylinder gate was removed and the
|
||||
two certs re-pinned with documentation explaining the shift.
|
||||
|
||||
## Current residual state at HEAD `7dceeff2`
|
||||
|
||||
### Cascade-OK tier (25 variants on pin grid) — sorted by |ΔSAP_c|
|
||||
|
||||
| Variant | SAP code | ΔSAP_c | Δcost | ΔPE | Notes |
|
||||
|---|---:|---:|---:|---:|---|
|
||||
| solid fuel 6 | 160 | +0.03 | -£0.65 | +45 | |
|
||||
| electric 1 | 191 | -0.06 | +£1.32 | +94 | |
|
||||
| solid fuel 8 | 160 | -0.08 | +£1.85 | +45 | |
|
||||
| **electric 3** | **401** | **-0.09** | **+£2.01** | **+82** | closed via S0380.145 |
|
||||
| solid fuel 7 | 160 | +0.10 | -£2.33 | +17 | |
|
||||
| electric 9 | 421 | -0.12 | +£2.72 | +91 | |
|
||||
| solid fuel 10 | 634 | -0.16 | +£3.70 | +67 | |
|
||||
| solid fuel 5 | 153 | -0.17 | +£3.81 | +93 | |
|
||||
| **electric 6** | **404** | **-0.17** | **+£3.91** | **+103** | closed via S0380.145 |
|
||||
| electric 2 | 524 | -0.18 | +£4.24 | +393 | closed via S0380.145; PE outlier |
|
||||
| solid fuel 9 | 636 | -0.20 | +£4.51 | +93 | |
|
||||
| **electric 7** | **408** | **-0.20** | **+£4.71** | **+113** | closed via S0380.145 |
|
||||
| ashp | — | +0.24 | -£5.57 | -12 | (closed) |
|
||||
| solid fuel 11 | 634 | -0.26 | +£6.07 | +104 | |
|
||||
| electric 8 | 409 | -0.26 | +£5.92 | +126 | |
|
||||
| solid fuel 4 | 633 | -0.29 | +£6.73 | +90 | |
|
||||
| oil pcdb 1/2 | (PCDB) | +0.42 | -£9.77 | -84 | (closed) |
|
||||
| pcdb 1 | (PCDB oil) | +0.57 | -£12.55 | -109 | closed via S0380.141..143 |
|
||||
| gshp | — | +1.15 | -£26.48 | -455 | open |
|
||||
| oil pcdb 3 | (PCDB) | +1.16 | -£26.72 | -271 | open |
|
||||
| **oil 1** | **127** | **+1.18** | **-£27.12** | **-276** | **closed via S0380.146..147 (Table 4f gap remaining)** |
|
||||
| solid fuel 3 | 160 | +1.32 | -£30.45 | -935 | PE outlier |
|
||||
| **electric 5** | **402** | **-1.43** | **+£32.85** | **+535** | regressed by S0380.145 |
|
||||
| solid fuel 2 | 158 | +2.64 | -£60.79 | -1211 | PE outlier |
|
||||
|
||||
Σ |ΔSAP_c| across 25 variants ≈ **10.7 SAP points** (was 12.2 pre-
|
||||
session, **-12%** progress).
|
||||
|
||||
### Blocked tier (16 variants — `MissingMainFuelType`)
|
||||
|
||||
Unchanged from previous handover. Categories: community heating × 5,
|
||||
electric storage 11-14, no system, oil 2-6, pcdb 3.
|
||||
|
||||
## Next-slice candidates ranked by leverage
|
||||
|
||||
### 1. **oil 1 SAP +1.18 / cost -£27 / PE -276** — Table 4f auxiliary energy
|
||||
|
||||
Cascade pumps_fans = **130 kWh/yr** vs worksheet (231) **265 kWh/yr**
|
||||
— under by 135 kWh. Breakdown:
|
||||
- Worksheet (230c) central heating pump = **165 kWh** (cascade has 130).
|
||||
- Worksheet (230d) oil boiler pump = **100 kWh** (cascade has 0).
|
||||
|
||||
Per SAP 10.2 Table 4f (PDF p.174). Closing both should drop cost
|
||||
residual by ~£18.50 and SAP residual by ~0.8 → oil 1 closes to ~+0.4.
|
||||
|
||||
### 2. **electric 5 SAP -1.43** — regressed by S0380.145, still open
|
||||
|
||||
Pre-S0380.145 was +0.07 (offsetting bugs). Post-slice with +0.4 K Table
|
||||
4e adjustment applied correctly: cascade now OVER worksheet SH by
|
||||
~248 kWh. Likely §9 MIT calc for fan-assisted storage heater R=0.40
|
||||
(code 402) OR Table 9b Tsc formula divergence.
|
||||
|
||||
### 3. **solid fuel 2 (+2.64) / 3 (+1.32) PE -935..-1211** — anthracite outliers
|
||||
|
||||
Both Table 4a codes 158/160. Distinct cause from oil 1. Per-variant
|
||||
probe required. Likely Table 4b solid-fuel efficiency, Table 4f
|
||||
auxiliary, or §9 anthracite-specific secondary fraction.
|
||||
|
||||
### 4. **gshp +1.15, oil pcdb 3 +1.16** — mid-tier
|
||||
|
||||
Each needs its own probe. gshp is heat-pump PCDB Table 362 dispatch;
|
||||
oil pcdb 3 is gas/oil PCDB Table 322 with different boiler model.
|
||||
|
||||
### 5. **Community heating unblocking (5 variants)** — sizable
|
||||
|
||||
Extend extractor to capture §14.1 Community Heating block (heat-network
|
||||
codes 41-58).
|
||||
|
||||
### 6. **Electric storage unblocking (variants 11-14)** — small
|
||||
|
||||
Extend `_ELMHURST_MAIN_HEATING_EES_TO_FUEL_CODE` for EES codes WEA,
|
||||
REA, OEA.
|
||||
|
||||
### 7. **Investigate cert 0240 / 6035 PE residual sources**
|
||||
|
||||
Slice S0380.147 shifted these from +0.05 / +46.10 PE to +1.02 / +47.29.
|
||||
The +1 kWh/m² delta likely indicates:
|
||||
- Dual-main Q_space split missing: cert 0240 is dual-main (51%/49%).
|
||||
Spec says Q_space in Eq D1 = (98c)m × (204) [Main 1 fraction], but
|
||||
cascade passes full (98c)m. Cascade over-counts Q_space → η_m closer
|
||||
to winter → HW fuel under. The Δ shift suggests this gap is real
|
||||
but compounded.
|
||||
- Table 4f auxiliary energy gap (same as oil 1).
|
||||
- Possibly other §4 cascade gaps unmasked by the spec-correct Eq D1.
|
||||
|
||||
## Important diagnostic findings from this session
|
||||
|
||||
1. **Two compound bugs for non-PCDB Table 4b oil boilers + cylinder:**
|
||||
primary loss missed (Table 3 row 1) + Eq D1 not wired. Required two
|
||||
slices to close. The probe-monkey-patch-verify workflow caught
|
||||
both before implementing either.
|
||||
|
||||
2. **Coincidence-zero closures break under spec correctness.** Cert
|
||||
0240 + 6035 were pinned at +0.05 PE residual pre-slice (looked
|
||||
"close to zero"). My spec-correct Eq D1 fix moved them to +1.02 /
|
||||
+1.20. The pre-slice near-zero was masking ~1 kWh/m² of offsetting
|
||||
cascade gaps. Per the user's directive: spec is paramount, re-pin
|
||||
shows the real underlying state.
|
||||
|
||||
3. **PCDB and Table 4b are separate cascade paths.** Eq D1 was already
|
||||
wired for PCDB (since S0380.141); Table 4b non-PCDB was the gap.
|
||||
Both use the same `water_efficiency_monthly_via_equation_d1`
|
||||
helper — `_apply_water_efficiency` now takes the (winter, summer)
|
||||
pair explicitly instead of a `GasOilBoilerRecord`, so future
|
||||
extensions (Table 4a category-fallback, etc.) plug in cleanly.
|
||||
|
||||
## Standard slice workflow
|
||||
|
||||
1. Read spec page + identify rule
|
||||
2. Probe one cluster variant; verify diagnosis via monkey-patch
|
||||
3. Write failing AAA test (literal `# Arrange / # Act / # Assert`)
|
||||
4. Implement helper / dispatch entry / mapper extension
|
||||
5. Re-pin affected variants (DO NOT widen tolerance)
|
||||
6. Run extended handover suite (command below)
|
||||
7. Pyright net-zero check (`git stash` → pyright → `git stash pop` →
|
||||
pyright)
|
||||
8. Commit with spec citation +
|
||||
`Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>`
|
||||
9. Update `project-heating-systems-corpus` + `MEMORY.md` index
|
||||
|
||||
## Test baseline at HEAD `7dceeff2`
|
||||
|
||||
```bash
|
||||
PYTHONPATH=/workspaces/model python -m pytest \
|
||||
backend/documents_parser/tests/test_summary_pdf_mapper_chain.py \
|
||||
backend/documents_parser/tests/test_heating_systems_corpus.py \
|
||||
backend/documents_parser/tests/test_elmhurst_extractor.py \
|
||||
backend/documents_parser/tests/test_elmhurst_end_to_end.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_e2e_elmhurst_sap_score.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_heat_transmission.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_internal_gains.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_solar_gains.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_dimensions.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_rating.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_ventilation.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_appendix_h_solar.py \
|
||||
domain/sap10_calculator/worksheet/tests/test_mev.py \
|
||||
domain/sap10_calculator/rdsap/tests/test_cert_to_inputs.py \
|
||||
domain/sap10_calculator/rdsap/tests/test_golden_fixtures.py \
|
||||
domain/sap10_calculator/tests/test_pcdb_table_322_lookup.py \
|
||||
domain/sap10_calculator/tests/test_pcdb_table_329_lookup.py \
|
||||
domain/sap10_calculator/tests/test_table_12a.py \
|
||||
--no-cov -q
|
||||
```
|
||||
|
||||
Expected: **890 pass, 0 fail**.
|
||||
|
||||
## Memories to load (in order)
|
||||
|
||||
```
|
||||
project-heating-systems-corpus # HEAD 7dceeff2
|
||||
feedback-sap-10-2-only-never-10-3 # CRITICAL — never reference SAP 10.3
|
||||
feedback-software-no-special-handling # NEW — spec is paramount, no empirical gates
|
||||
feedback-worksheet-not-api-reference
|
||||
feedback-spec-citation-in-commits
|
||||
feedback-verify-handover-claims
|
||||
feedback-zero-error-strict # TARGET: ΔSAP_c < 1e-4 vs worksheet
|
||||
feedback-commit-per-slice
|
||||
feedback-aaa-test-convention
|
||||
feedback-e2e-validation-philosophy
|
||||
feedback-abs-diff-over-pytest-approx
|
||||
feedback-spec-floor-skepticism
|
||||
feedback-golden-residuals-near-zero
|
||||
feedback-one-e-minus-4-across-the-board
|
||||
reference-unmapped-sap-code
|
||||
reference-unmapped-api-code
|
||||
project-oil-price-spec-divergence
|
||||
```
|
||||
|
||||
## What NOT to do
|
||||
|
||||
- **Don't reference SAP 10.3** — track 10.2 deliberately
|
||||
- **Don't widen pin tolerances** to make pins pass — re-pin smaller
|
||||
or find the spec gap
|
||||
- **Don't add empirical gates** to keep cohort pins stable when a
|
||||
spec rule clearly applies — the BRE/Elmhurst software follows spec
|
||||
uniformly per `feedback-software-no-special-handling`
|
||||
- **Don't re-investigate Slices .91..147** — all settled
|
||||
- **Don't add new helpers to `domain/sap10_ml/`** — on deprecation
|
||||
path; `domain/sap10_calculator/tables/` is the canonical home
|
||||
- **Don't treat ΔSAP=0.07 as "closed"** — it might be offsetting bugs.
|
||||
Target is < 1e-4 vs worksheet.
|
||||
|
||||
## Spec source quick-reference
|
||||
|
||||
All under `domain/sap10_calculator/docs/specs/`:
|
||||
|
||||
- **SAP 10.2 full spec**: `sap-10-2-full-specification-2025-03-14.pdf`
|
||||
- **§4** (p.135-137) — water heating worksheet (45..65)
|
||||
- **§9** (p.155+) — MIT calc, Tables 9/9a/9b/9c
|
||||
- **§9.4.11** (p.30) — Boiler interlock: -5pp to BOTH SH and DHW
|
||||
- **§A.2.2** (~p.189) — Forced-secondary set "401 to 407, 409 and 421"
|
||||
- **Table 3** (p.160) — Primary circuit loss; zero-loss list
|
||||
- **Table 4a** (p.163-170) — heating systems incl. R column
|
||||
- **Table 4b** (p.168) — gas/liquid boilers seasonal efficiency, codes 101-141
|
||||
- **Table 4c** (p.169-170) — Efficiency adjustments
|
||||
- **Table 4d** (p.170) — heat-emitter R
|
||||
- **Table 4e** (p.170-173) — heating system controls + temperature adjustment
|
||||
- **Table 4f** (p.174) — pumps + fans (NEXT — oil 1 / etc.)
|
||||
- **Table 9** (p.182) — heating periods and temperatures
|
||||
- **Table 9c** (p.184) — heating requirement (step 8 Table 4e adj)
|
||||
- **Table 11** (p.188) — secondary heating fraction
|
||||
- **Table 12** (p.191) — SAP rating fuel prices
|
||||
- **Table 12a** (p.191) — high/low-rate fraction by system × tariff
|
||||
- **Appendix D §D2.1 (2)** (p.57) — Eq D1 monthly water eff cascade
|
||||
- **RdSAP 10 spec**: `RdSAP 10 Specification 10-06-2025.pdf`
|
||||
- **§10.11 Table 29** (p.56) — Heating/HW parameters; inaccessible cylinder
|
||||
- **§19 Table 32** (p.95) — RdSAP10 fuel prices / CO2 / PE
|
||||
|
||||
## Good luck.
|
||||