mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-06-08 11:17:27 +00:00
Handover: 2/6 Elmhurst chains closed at 1e-4; per-cert diagnoses for remaining 4
Updates NEXT_AGENT_PROMPT.md after Slices 47/48/49. State at hand-off:
000474 Δ=0.0000 ✓ Slice 47
000477 Δ=2.6555 Room-in-Roof support needed (15.06 m² 3rd storey)
000480 Δ=4.1955 diagnosis pending
000487 Δ=4.4553 extractor drops most §11 windows on this layout
000490 Δ=0.0000 ✓ Slice 49
000516 Δ=1.5162 roof-window separation (1 of 6 extracted windows
is actually a roof window per handbuilt fixture)
Each remaining cert needs its own schema/extractor/mapper extension —
documented with file/method pointers and recommended slice ordering.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
parent
7f17de84aa
commit
ec4916b5a7
1 changed files with 85 additions and 79 deletions
|
|
@ -1,78 +1,88 @@
|
|||
# Handover — close the remaining 5 Elmhurst Summary→SAP chains to 1e-4
|
||||
# Handover — close the remaining 4 Elmhurst Summary→SAP chains to 1e-4
|
||||
|
||||
You are picking up branch `ara-backend-design-prd` mid-stream. The
|
||||
previous chain of work closed **Summary_000474** to 1e-4 (Slice 47)
|
||||
and landed extractor infrastructure that helps the other 5 fixtures
|
||||
(Slice 48), but each of the 5 remaining certs still has its own diff
|
||||
to close. This handover captures the exact per-cert state so you
|
||||
don't have to rediscover it.
|
||||
You are picking up branch `ara-backend-design-prd` mid-stream. Two
|
||||
of six fixtures are now closed at 1e-4 (000474 + 000490). The other
|
||||
four still have substantive diffs that each need their own mapper
|
||||
or extractor extension to close.
|
||||
|
||||
## The 30-second picture
|
||||
|
||||
```
|
||||
Cert Mapped SAP Target SAP Δ Notes
|
||||
000474 62.2584 62.2584 0.0000 ✓ CLOSED (Slice 47)
|
||||
000477 71.3712 65.0057 +6.3655 secondary heating + lighting
|
||||
000480 69.5681 61.2986 +8.2695 unknown (largest gap)
|
||||
000487 69.7864 61.6431 +8.1433 window count 1/many (extractor) + others
|
||||
000490 63.0530 57.3979 +5.6551 unknown
|
||||
000516 68.7749 62.7937 +5.9812 roof window separation
|
||||
Cert Mapped SAP Target SAP Δ State
|
||||
000474 62.2584 62.2584 0.0000 ✓ Slice 47
|
||||
000477 67.6612 65.0057 +2.6555 Room-in-Roof support (15.06 m² 3rd storey)
|
||||
000480 65.4941 61.2986 +4.1955 diagnosis pending
|
||||
000487 66.0984 61.6431 +4.4553 extractor drops most §11 windows
|
||||
000490 57.3979 57.3979 0.0000 ✓ Slice 49
|
||||
000516 64.3099 62.7937 +1.5162 roof-window separation
|
||||
```
|
||||
|
||||
All Δ are positive — the mapper is computing SAP too HIGH, which
|
||||
typically means missing cost contributions (secondary heating fuel,
|
||||
lighting, etc.) or under-counted heat-loss area.
|
||||
|
||||
Forcing function for the 000474 case is in:
|
||||
`backend/documents_parser/tests/test_summary_pdf_mapper_chain.py::test_summary_000474_full_chain_sap_matches_worksheet_pdf_exactly`
|
||||
(green at 1e-4). When you close each remaining cert, add a mirror
|
||||
test next to it.
|
||||
All Δ are positive — mapper computes SAP too HIGH. Forcing functions
|
||||
in `backend/documents_parser/tests/test_summary_pdf_mapper_chain.py`:
|
||||
2 chain tests green (000474, 000490), 2 structural tests green (BPs,
|
||||
windows for 000474). 4 mirror tests to add as each closes.
|
||||
|
||||
## What landed already
|
||||
|
||||
| Slice | Commit | What |
|
||||
|---|---|---|
|
||||
| 47 | `29ab80b0` | `main_heating_category=2` in mapper → pumps_fans 130→160; window-gap partitioned on glazing-type-start marker → fixes W4/W5 orientation mis-classification |
|
||||
| 48 | (this slice) | Extractor handles combined `Wood 0.70` frame line; data anchor allows trailing glazing-type (`1.22 1.76 2.15 Double pre 2002`); partition falls back to second-orient-token when no glazing marker in gap; 5 fixture PDFs copied to `backend/documents_parser/tests/fixtures/` |
|
||||
| 47 | `29ab80b0` | `main_heating_category=2` in mapper → pumps_fans 130→160; window-gap partitioned on glazing-type-start marker → fixes W4/W5 orientation. Closed 000474. |
|
||||
| 48 | `00a27efd` | Extractor handles `Wood 0.70` combined frame-line; data anchor allows trailing glazing-type (`1.22 1.76 2.15 Double pre 2002`); partition falls back to second-orient-token when no glazing marker in gap. 5 fixture PDFs copied to `backend/documents_parser/tests/fixtures/`. |
|
||||
| 49 | `7f17de84` | Elmhurst `MainHeating.secondary_heating_sap_code` extracted from §14.1 Main Heating2 sub-section; mapper threads through to `SapHeating.secondary_heating_type`. RdSAP §S5 sheltered-sides defaults derived from built_form. Closed 000490. |
|
||||
|
||||
## Per-cert diff diagnoses (already done — don't re-discover)
|
||||
|
||||
### 000477 — Δ +6.37 — single-BP cert
|
||||
Run `python /tmp/diff_cert.py 000477` to reproduce. Scalar input diffs:
|
||||
- `secondary_heating_fraction`: mapped=**0.0** vs handbuilt=**0.1** ← root cause. Handbuilt has `secondary_heating_type=691` (Electric panel heaters) lodged on `SapHeating`. Mapper doesn't extract from §10 "Secondary heating" Summary PDF section.
|
||||
- `lighting_kwh_per_yr`: mapped=160.88 vs handbuilt=201.68 — bulb count mismatch
|
||||
- `secondary_heating_co2_factor_kg_per_kwh`, `secondary_heating_primary_factor`: None vs populated — downstream of the missing secondary_heating_type
|
||||
### 000477 — Δ +2.66 — Room-in-Roof support needed
|
||||
Summary PDF §4.0 lodges `Room(s) in Roof: 15.06` (m²). Mapper drops
|
||||
this entirely — `total_floor_area_m2=62.52` vs handbuilt 77.58
|
||||
(exactly +15.06 m²); `storey_count=2` vs 3; `roof_w_per_k=4.38` vs
|
||||
35.97. Look at:
|
||||
|
||||
**Fix**: Extend `ElmhurstSiteNotesExtractor` to extract §10 Secondary heating fields, and `_map_elmhurst_sap_heating` to populate `secondary_heating_type` + `secondary_fuel_type` on the `SapHeating`.
|
||||
- `ElmhurstSiteNotes.BuildingPartDimensions` — needs a
|
||||
`room_in_roof_area_m2` field (and probably room-in-roof construction
|
||||
+ insulation details too).
|
||||
- `ElmhurstSiteNotesExtractor._extract_dimensions` (or wherever §4 is
|
||||
handled) — parse the "Room(s) in Roof" line.
|
||||
- `from_elmhurst_site_notes` — build a `SapRoomInRoof` and attach to
|
||||
the building part. See existing API paths like
|
||||
`datatypes/epc/domain/mapper.py:749-760` for the API-side analog.
|
||||
- Handbuilt: see `_elmhurst_worksheet_000477.py` `sap_room_in_roof=...`.
|
||||
|
||||
### 000487 — Δ +8.14 — only 1 window extracted (should be many)
|
||||
Once Room-in-Roof lands, the other diffs (party_walls, infiltration,
|
||||
lighting kWh) may shrink as the dwelling shape becomes correct.
|
||||
|
||||
### 000487 — Δ +4.46 — only 1 of many windows extracted
|
||||
Despite Slice 48's frame-line + data-anchor improvements, the §11
|
||||
table layout of this cert still drops most windows. Run
|
||||
`python /tmp/dump_one.py 000487` to see the parsed window. Inspect
|
||||
the raw layout via `python /tmp/dump_section.py 000487` — the table
|
||||
has a different cell-joining pattern that the current parser hasn't
|
||||
yet covered.
|
||||
`python /tmp/dump_section.py 000487` to inspect — this PDF has yet
|
||||
another layout pattern (see lines 14-50 in the section dump). Look
|
||||
at the actual fields: `'1st'` ordinal in prefix WITHOUT a preceding
|
||||
glazing-type line, etc.
|
||||
|
||||
### 000516 — Δ +5.98 — roof window contamination
|
||||
6 vertical windows extracted (correct: 5) — the 6th is actually a
|
||||
**roof window** (`1.05×1.12=1.18 m² U=3.10 NE`, pitch 45°) being
|
||||
treated as vertical. Handbuilt 000516 separates this into
|
||||
`sap_roof_windows=[SapRoofWindow(area_m2=1.18, u_value_raw=3.40,
|
||||
orientation=2 NE, pitch_deg=45.0, ...)]`.
|
||||
### 000516 — Δ +1.52 — roof-window contamination
|
||||
6 vertical windows extracted (correct: 5 vertical + 1 roof). The 6th
|
||||
is a roof window (`1.05×1.12=1.18 m² U=3.10` lodged → U=2.99 in
|
||||
worksheet line 27a, but handbuilt uses `u_value_raw=3.40` — needs
|
||||
investigation of how Elmhurst computes the in-situ value). Handbuilt:
|
||||
|
||||
**Fix**: Add roof-window extraction in `ElmhurstSiteNotesExtractor`
|
||||
(likely a "Roof Windows" subsection of §11). Map to `SapRoofWindow`
|
||||
not `SapWindow`.
|
||||
```python
|
||||
sap_roof_windows=[SapRoofWindow(
|
||||
area_m2=1.18, u_value_raw=3.40, orientation=2 NE,
|
||||
pitch_deg=45.0, g_perpendicular=0.76, frame_factor=0.70,
|
||||
)]
|
||||
```
|
||||
|
||||
### 000480 — Δ +8.27 — diagnosis pending
|
||||
Run `python /tmp/diff_cert.py 000480` to start. Two BPs (Main + ext)
|
||||
extracted correctly, 7 windows extracted. Largest gap of the 5 — may
|
||||
have multiple compounding issues.
|
||||
The Summary PDF doesn't have an explicit "roof window" type marker —
|
||||
the discrimination is by **U-value range** (>3.0 W/m²K characteristic
|
||||
of roof window) or by some other heuristic. Investigate which signal
|
||||
Elmhurst uses; may also need a `Roof Windows` subsection if a later
|
||||
fixture has one.
|
||||
|
||||
### 000490 — Δ +5.66 — diagnosis pending
|
||||
Same: `python /tmp/diff_cert.py 000490`.
|
||||
### 000480 — Δ +4.20 — diagnosis pending
|
||||
Run `python /tmp/diff_objects.py 000480` to start. Already has 2 BPs
|
||||
+ 7 windows correctly extracted post-Slice 48.
|
||||
|
||||
## Probe scripts (already in `/tmp`)
|
||||
## Probe scripts (in `/tmp`)
|
||||
|
||||
```bash
|
||||
# Probe all 6 fixtures' SAP delta
|
||||
|
|
@ -84,35 +94,31 @@ python /tmp/dump_one.py 000516
|
|||
# Dump the §11 Windows section layout (debug extractor)
|
||||
python /tmp/dump_section.py 000487
|
||||
|
||||
# Field-by-field input diff mapped vs handbuilt
|
||||
python /tmp/diff_cert.py 000477
|
||||
# Field-by-field input diff mapped vs handbuilt (scalars + objects)
|
||||
python /tmp/diff_objects.py 000477
|
||||
|
||||
# Verify secondary heating + sheltered-sides plumbing
|
||||
python /tmp/check_secondary.py
|
||||
```
|
||||
|
||||
If `/tmp` got wiped, the contents are:
|
||||
- `probe_all.py`: iterates 6 fixtures, mapper-cascades each, prints
|
||||
Δ and BPs/windows counts.
|
||||
- `dump_one.py <cert>`: prints raw `ElmhurstSiteNotes.windows` for
|
||||
the given cert.
|
||||
- `dump_section.py <cert>`: prints the line-by-line `§11 Windows`
|
||||
section from the layout-preprocessed pages.
|
||||
- `diff_cert.py <cert>`: cascades both mapped and handbuilt EPCs
|
||||
through `cert_to_inputs`, diffs the scalar input fields.
|
||||
If `/tmp` got wiped, the contents are documented in commit `7f17de84`'s
|
||||
diff (the prior handover writeup). Re-create them by following the
|
||||
patterns there.
|
||||
|
||||
## Suggested next slices
|
||||
|
||||
| Slice | Cert | Effort | Why next |
|
||||
|---|---|---|---|
|
||||
| 49 | 000477 | Medium | 1 BP topology → smallest moving parts; secondary-heating extraction unlocks the largest single fix |
|
||||
| 50 | 000516 | Medium | Roof-window separation — adds new schema field, generalisable |
|
||||
| 51 | 000487 | High | Extractor parser improvements (the §11 layout is uncovered terrain) |
|
||||
| 52 | 000490 | Unknown | Diagnose then close |
|
||||
| 53 | 000480 | Unknown | Largest Δ; do last after others reveal patterns |
|
||||
| 50 | 000516 | Medium | Roof-window separation by U-value threshold; smallest remaining Δ |
|
||||
| 51 | 000477 | High | Room-in-Roof schema + extractor + mapper plumbing; biggest unlock |
|
||||
| 52 | 000487 | Medium-High | Extractor §11 layout — third PDF variant; may share work with 000477's room-in-roof if §11 layout matches |
|
||||
| 53 | 000480 | Unknown | Diagnose then close after others reveal patterns |
|
||||
|
||||
## Definition of done (unchanged from before)
|
||||
## Definition of done (unchanged)
|
||||
|
||||
- All 6 `test_summary_pdf_mapper_chain.py` chain tests pin at 1e-4.
|
||||
- Wider regression stays green (currently 754 pass).
|
||||
- Pyright net-zero on every commit (strict mode).
|
||||
- Wider regression stays green (currently 755 pass).
|
||||
- Pyright net-zero on every commit (strict mode; baseline 35 errors).
|
||||
- One slice = one commit.
|
||||
- No widening, no xfail (project memory `feedback_zero_error_strict`).
|
||||
|
||||
|
|
@ -120,20 +126,20 @@ If `/tmp` got wiped, the contents are:
|
|||
|
||||
- `docs/sap-spec/HANDOVER_NEXT.md` — original cascade-conventions handover.
|
||||
- `docs/sap-spec/SAP_CALCULATOR.md` — public API + two-cascade architecture.
|
||||
- Hand-built worksheet fixtures: `packages/domain/src/domain/sap/worksheet/tests/_elmhurst_worksheet_*.py` — the calculator-equivalent EpcPropertyData each mapped chain must reproduce.
|
||||
- Untracked source PDFs: `sap worksheets/` (`Summary_NNNNNN.pdf` + `U985-0001-NNNNNN.pdf` worksheets — the unrounded SAP target lives next to "SAP value" in the U985 PDF).
|
||||
- Hand-built worksheet fixtures: `packages/domain/src/domain/sap/worksheet/tests/_elmhurst_worksheet_*.py`.
|
||||
- Untracked source PDFs: `sap worksheets/` (`Summary_NNNNNN.pdf` + `U985-0001-NNNNNN.pdf` worksheets).
|
||||
|
||||
## Branch state at handover
|
||||
|
||||
```
|
||||
$ git log --oneline -7
|
||||
<this commit> Slice 48: Elmhurst extractor handles 5 new layout quirks; 5 fixture PDFs added
|
||||
29ab80b0 Slice 47: Summary_000474 chain pins SAP at 1e-4 vs worksheet PDF
|
||||
b6544e1c Handover: tighten Summary→SAP chain pin to 1e-4 + brief next agent
|
||||
256a5afe Slice 46c: Elmhurst mapper produces calculator-equivalent EpcPropertyData — Summary_000474 SAP within 0.5 of worksheet PDF
|
||||
066dce19 Slice 46b: Elmhurst extractor parses windows from layout-style Summary PDFs
|
||||
36f2c7bb Slice 46a: Elmhurst mapper handles multi-bp Summary PDFs — Summary_000474 chain test flips green
|
||||
ccf7aa21 Scaffold: end-to-end Summary→EpcPropertyData chain test for 000474 (xfail)
|
||||
7f17de84 Slice 49: Summary_000490 chain pins SAP at 1e-4; secondary heating + RdSAP sheltered-sides
|
||||
00a27efd Slice 48: Elmhurst extractor handles 3 new layout quirks; 5 fixture PDFs added
|
||||
29ab80b0 Slice 47: Summary_000474 chain pins SAP at 1e-4 vs worksheet PDF
|
||||
b6544e1c Handover: tighten Summary→SAP chain pin to 1e-4 + brief next agent
|
||||
256a5afe Slice 46c: Elmhurst mapper produces calculator-equivalent EpcPropertyData — Summary_000474 SAP within 0.5 of worksheet PDF
|
||||
066dce19 Slice 46b: Elmhurst extractor parses windows from layout-style Summary PDFs
|
||||
36f2c7bb Slice 46a: Elmhurst mapper handles multi-bp Summary PDFs — Summary_000474 chain test flips green
|
||||
```
|
||||
|
||||
Good luck.
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue