Merge pull request #1443 from Hestia-Homes/fix/electric-room-heater-overlay-companions

Electric room heaters override forces its category + control (fix silent storage-companion inheritance)
This commit is contained in:
KhalimCK 2026-07-03 11:13:35 +01:00 committed by GitHub
commit f822f8a15d
No known key found for this signature in database
GPG key ID: B5690EEEBB952194
4 changed files with 226 additions and 4 deletions

View file

@ -103,6 +103,10 @@ _Avoid_: patches (deprecated), corrections, manual EPC, edits
**Landlord-Description Classification**:
Resolving a **Landlord Description** (unbounded free-text a landlord supplies for one component — "CWI" / "Cav filled" / "cavity insulated" all name one thing) onto a **Recognised Internal Description** via an LLM classifier, persisted in the `landlord_*_overrides` table (`source=classifier`) as a reviewed cache. Four vocabularies are kept **distinct** and must not be conflated: a **Landlord Description** (unbounded input); a **Recognised Internal Description** (the closed target taxonomy — e.g. a `MainHeatingSystemType` archetype — each binding to a Simulation Overlay); a **Lodged Description** (the gov-EPC `main_heating[].description` rendering, e.g. "Room heaters, electric" — only an example of which system *types* occur, never a map key); and the **SAP main heating code** (Table 4a/4b, what the calculator consumes). The classifier maps Landlord → Recognised Internal → SAP code. When it cannot confidently place the text it emits **`None`** (no overlay → the lodged EPC stands, surfaced to the user as "no suitable match"), **never the nearest wrong archetype** — the target taxonomy must be complete enough that a real system always has a correct home, so the classifier never overflows into a garbage-drawer archetype (ADR-0041).
**Heating Companion Set**:
The coherent SAP inputs a **main heating system** override drags alongside the **SAP main heating code** so the **Effective EPC** reads as one internally-consistent system, not a hybrid of the new code and the *replaced* system's leftovers — heating **category** (SAP Table 4a group: gas→2, heat pump→4, network→6, storage→7, electric underfloor→8, warm air→9, room heater→10), **charge/heating control** (Table 4e group), **natural fuel**, and **meter** (see **Off-Peak Meter**). Companions divide by how firmly the archetype fixes them (ADR-0048): **category and control are archetype-forced** — always written, never inherited, because a wrong value silently mis-scores or mis-bills (a leftover storage **category 7** makes the Table 12a resolver bill peaky room heaters at the all-night rate; a leftover storage **control 2401** adds a +0.7 °C Table-4e penalty a room heater should not carry). **Fuel and meter defer** only where multiple values are genuinely coherent — fuel for an ambiguous carrier (community heating: gas CHP / biomass / waste heat), meter for a meter-flexible system (room heaters run on either; screed underfloor per ADR-0046) — while a meter-*locked* system still forces (storage/CPSU/HHRSH→Dual, non-electric→Single, ADR-0035). Because the overlay composes last-wins, an **unset (`None`)** forced companion is *inherited from the replaced system*, not cleared — so an archetype the overlay cannot yet fully companion (heat pump / community / underfloor / electric boiler control defaults are unmapped) is **logged as an error and continues** (log-not-raise, matching `flag_fuel_mismatch`), making the gap visible for review rather than shipping a silently-incoherent cert; the intended end-state is to fill each and flip the log to a raise.
_Avoid_: coherent companions (informal), dragged fields, heating defaults
_Avoid_: "the LLM mapper is unreliable" (the failure mode is a too-small target taxonomy, not LLM language ability); conflating the landlord input vocabulary with the gov-EPC lodged rendering or the RdSAP entry-tool catalogue; treating a deterministic dict as a *replacement* for the LLM rather than a reviewed cache of its output
**Lodgement Sentinels (ND / NI / AB)**:

View file

@ -0,0 +1,132 @@
# A system-replacing heating override forces category and control for coherence, and defers fuel and meter where multiple values are valid
## Status
accepted
## Context
A **Landlord Override** naming a main heating system resolves to a SAP Table 4a
code, and `main_heating_system_overlay` synthesises the **coherent companions**
that code implies (ADR-0035): heating category, charge control, natural fuel,
meter. The overlay is applied over the lodged cert by last-wins composition, so a
companion the overlay leaves **unset (`None`)** is *inherited from the replaced
system* — not cleared.
That inheritance is a silent mis-rating when the archetype genuinely determines
the companion. A portfolio-796 audit found the case end-to-end on **86+
properties**: a lodged **slimline storage heater** (SAP 402, category 7, control
2401, off-peak) overridden to **"Electric room heaters"** (SAP 691). The overlay
stamped code 691, fuel, and a Dual meter — but `_category_for(691)` and
`_control_for(691)` both returned `None`, because their room-heater branch keyed
on `_CATEGORY_10_ROOM_HEATER_CODES`, a set that held only the *fuel-burning*
(gas/oil/solid) room heaters and **excluded electric 691701** despite electric
room heaters also being Table 4a **Category 10**.
Two independent mis-ratings followed from the surviving storage companions:
1. **Category 7 survived.** The SAP 10.2 Table 12a resolver keys on category
first, read `OTHER_STORAGE_HEATERS`, and — with the dwelling on the §12 Rule 3
10-hour tariff — hit `(OTHER_STORAGE_HEATERS, TEN_HOUR)`, a combination the
Grid-1 table does not carry, so it fell to the all-low-rate fallback. The
peaky room heaters were billed **100% at the night rate** — the precise
"all-low over-credit" the overlay's own Dual-meter comment claims to avoid.
Effect: baseline SAP over-rated **64.1 vs the spec-correct 56.4**; the HHRSH
upgrade measure showed a **negative** bill saving (£13/yr) because the
baseline it was compared against was itself under-billed.
2. **Control 2401 survived.** `main_heating_control` fed Table 4e as the storage
**manual charge control → +0.7 °C** mean-internal-temperature adjustment — the
largest in the table — riding on a direct-acting room heater, which should
carry the Group 6 room-heater control **2601 → +0.3 °C**.
The companions are **not uniform** in how strongly the archetype determines
them, which is the crux of the decision:
- **Category is deterministic** — SAP Table 4a assigns exactly one category per
code (gas→2, heat pump→4, network→6, storage→7, **electric underfloor→8**,
warm-air→9, **room heater→10**). A `None` category is never valid.
- **Control is an assumption but always archetype-supplied** — the Table 4e
*Group* is fixed by category; the specific conservative default within the
group is a modelling choice (storage→manual 2401, HHRSH→2404 per
[ADR-0044](0044-hhrsh-baseline-archetype-drags-its-intrinsic-controls.md),
room heater→2601, gas boiler→full controls). It is never "inherit the replaced
system".
- **Fuel is sometimes genuinely ambiguous** — electric/gas/storage/heat-pump
archetypes pin their fuel, but **community heating** could be gas CHP, biomass,
or waste heat, so its fuel legitimately **defers** to a `main_fuel` override,
else the lodged value (ADR-0041 last-wins).
- **Meter is physics-locked for some systems, flexible for others** — storage /
CPSU / HHRSH **require** Dual (they charge overnight); non-electric systems are
stamped Single to stop an Economy-7 split bleeding onto a gas boiler
([ADR-0035](0035-coherent-heating-system-synthesis.md)); screed underfloor
defers to the cert ([ADR-0046](0046-electric-underfloor-scored-by-its-own-codes-meter-deferred-when-tariff-ambiguous.md)).
## Decision
A system-replacing heating override must emit a **complete, coherent companion
set**. Companions split by whether the archetype *determines* the value:
1. **Category and control are archetype-forced** — always written, never
inherited, because a wrong value mis-scores or mis-bills the cert. Electric
room heaters (Table 4a 691701) join the Category-10 room-heater branch of
both `_category_for` (→ category **10**) and `_control_for` (→ control
**2601**, the Group 6 conservative no-thermostat default, matching the
gas/oil/solid siblings). Their fuel (electricity 29) and Dual meter were
already correct and are unchanged.
2. **Fuel and meter defer where multiple values are coherent** — this is *not*
a gap. Fuel defers only for genuinely ambiguous carriers (community heating);
meter defers only for meter-flexible systems (room heaters run coherently on
either meter; screed underfloor per ADR-0046). Meter-locked systems still
force (storage/CPSU/HHRSH → Dual; non-electric → Single).
3. **An incomplete companion set is logged, not raised (for now).** Where the
overlay cannot yet supply a confident category or control — heat pumps
(Group 2), community (Group 3), electric underfloor (Group 7), electric
boiler / CPSU (Group 1) — `main_heating_overlay_for` **logs an error** naming
the archetype and code and continues, matching the `flag_fuel_mismatch`
log-not-raise convention. Log-and-continue keeps a mid-portfolio run alive
and surfaces the gap (CloudWatch) for review, rather than turning a latent
inheritance bug into an outage. The intended end-state is to fill each
archetype's category/control with spec sight and then **flip the log to a
raise**, so the coherence invariant is enforced.
Category expansion for the still-`None` archetypes (electric boiler/CPSU→2,
underfloor→8) is deterministic from Table 4a but **deferred** to its own change:
it flows into the category-keyed Table 12a resolver and needs a corpus check, so
it does not ride on the room-heater fix.
## Consequences
- The 86+ room-heater dwellings score against a correctly-billed baseline: the
space-heating high-rate fraction is the spec **0.50** (10-hour direct-acting),
not 0.0; baseline SAP corrects **64.1 → 56.4**; the HHRSH measure's bill saving
flips **£13/yr → +£235/yr** (property 710788, uprn 22003310, scenario 1268).
- The `refetch_solar`-corrected portfolio's `negative-bill-savings` audit group
loses its ~86-property HHRSH-on-room-heater cluster after re-model.
- The overlay now emits a visible error for any archetype it cannot fully
companion — a standing signal (wire a CloudWatch metric filter on the log
string) for which control default to fill next.
- Extends [ADR-0035](0035-coherent-heating-system-synthesis.md) (companions drag
from the code) and [ADR-0041](0041-landlord-heating-classification-targets-a-complete-modellable-taxonomy.md)
(complete taxonomy); sits beside
[ADR-0044](0044-hhrsh-baseline-archetype-drags-its-intrinsic-controls.md)
(a control named by the archetype) and
[ADR-0046](0046-electric-underfloor-scored-by-its-own-codes-meter-deferred-when-tariff-ambiguous.md)
(meter deferred where the tariff is ambiguous).
### Alternatives rejected
- **Make every companion total (force fuel and meter too).** Rejected: it breaks
the deliberate deferrals — community-heating fuel (ambiguous carrier) and the
ADR-0046 screed-underfloor meter — whose `None` is a load-bearing "defer to the
cert/override" signal, not a gap.
- **Fix the Table 12a resolver to prefer the SAP code over a stale category.**
A sound defence-in-depth follow-up, but it treats the symptom; the overlay
emitting an incoherent cert is the root cause, and category/control coherence
must hold for every consumer (predicted EPCs, raw lodged certs), not only the
billing resolver.
- **Raise on an incomplete companion set now.** Rejected for this change: heat
pump / community / underfloor overrides model today (by luck of inheritance),
so an immediate raise is a blast-radius change mid-campaign. Log now, raise once
the common archetypes are filled.

View file

@ -28,6 +28,7 @@ are left UNKNOWN until modelled. Unresolvable values produce no overlay.
from __future__ import annotations
import logging
from typing import Optional
from domain.modelling.simulation import EpcSimulation, HeatingOverlay
@ -35,6 +36,8 @@ from domain.sap10_calculator.tables.table_12a import (
OFF_PEAK_IMPLYING_HEATING_CODES,
)
logger = logging.getLogger(__name__)
# Off-peak (Economy 7) meter. Electric storage / CPSU systems charge overnight at
# the low rate and cannot run economically on a single-rate meter; "Dual" lets
# the §12 dispatch resolve the specific tariff (storage 7-hour, CPSU 10-hour).
@ -266,7 +269,7 @@ def _control_for(code: int) -> Optional[int]:
return _MANUAL_CHARGE_CONTROL
if code in _GAS_BOILER_CODES:
return _FULL_BOILER_CONTROL
if code in _CATEGORY_10_ROOM_HEATER_CODES:
if code in _CATEGORY_10_ROOM_HEATER_CODES or code in _ELECTRIC_ROOM_HEATER_CODES:
return _ROOM_HEATER_CONTROL
return None
@ -280,7 +283,7 @@ def _category_for(code: int) -> Optional[int]:
category 7); without it a storage override left a stale category behind,
which the SAP 10.2 Table 12a resolver (keyed on category) could misread as a
non-storage system and price the off-peak storage heating at the peak rate."""
if code in _CATEGORY_10_ROOM_HEATER_CODES:
if code in _CATEGORY_10_ROOM_HEATER_CODES or code in _ELECTRIC_ROOM_HEATER_CODES:
return _ROOM_HEATER_CATEGORY
if code in _STORAGE_HEATER_CODES:
return _STORAGE_HEATER_CATEGORY
@ -351,13 +354,32 @@ def main_heating_overlay_for(
return None
if code in _GAS_BOILER_CODES:
return EpcSimulation(heating=_gas_boiler_overlay(code))
category = _category_for(code)
control = _control_for(code)
if category is None or control is None:
# A system-replacing override should stamp a complete, coherent companion
# set; an unmapped category or control leaves the field unset, so the
# effective cert inherits the REPLACED system's value (a silent mis-rating
# — e.g. a room heater keeping a storage heater's category/control). We do
# not yet have confident defaults for every archetype, so log-and-continue
# (matching `flag_fuel_mismatch`) to make the gap visible for review
# rather than raise mid-run.
logger.error(
"Landlord main_heating_system %r (SAP code %d) overlaid with an "
"incomplete companion set (category=%s, control=%s); the effective "
"cert may inherit the replaced system's value — known gap, review",
main_heating_value,
code,
category,
control,
)
return EpcSimulation(
heating=HeatingOverlay(
sap_main_heating_code=code,
main_heating_category=_category_for(code),
main_heating_category=category,
main_fuel_type=_natural_fuel_for(code),
meter_type=_meter_for(code),
main_heating_control=_control_for(code),
main_heating_control=control,
# A landlord override describes the existing dwelling, so its assumed
# off-peak meter must not downgrade a more-off-peak cert meter
# (e.g. a 24-hour all-low tariff). Measures, which re-meter for real,

View file

@ -6,6 +6,8 @@ calculator reads from the primary system; the overlay is whole-dwelling.
from __future__ import annotations
import logging
import pytest
from domain.epc.property_overrides.main_heating_system_type import MainHeatingSystemType
@ -58,6 +60,68 @@ def test_electric_room_heaters_assume_a_dual_economy7_meter() -> None:
assert simulation.heating.meter_type == "Dual"
def test_electric_room_heaters_overlay_the_room_heater_category() -> None:
# A landlord "Electric room heaters" override replaces the lodged system, so
# the overlay must stamp the room-heater heating category (SAP Table 4a
# Category 10). Leaving it unset lets a replaced storage heater's category 7
# survive onto the effective cert, which the SAP 10.2 Table 12a resolver
# (keyed on category) mis-reads as off-peak storage and bills the peaky room
# heaters at the all-night low rate.
# Act
simulation = main_heating_overlay_for("Electric room heaters", 0)
# Assert — SAP Table 4a Category 10 (Room heaters).
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_category == 10
def test_electric_room_heaters_overlay_the_room_heater_charge_control() -> None:
# A system-replacing override must stamp its own control, not inherit the
# replaced system's. Electric room heaters take the Table 4e Group 6
# room-heater control 2601 (+0.3 C, the conservative no-thermostat default,
# matching the gas/oil/solid room heaters). Leaving it unset lets a replaced
# storage heater's manual charge control 2401 (+0.7 C) survive and over-warm
# the modelled dwelling.
# Act
simulation = main_heating_overlay_for("Electric room heaters", 0)
# Assert — SAP Table 4e Group 6 room-heater control.
assert simulation is not None
assert simulation.heating is not None
assert simulation.heating.main_heating_control == 2601
def test_overlay_logs_when_it_cannot_complete_a_companion_set(
caplog: pytest.LogCaptureFixture,
) -> None:
# An archetype the overlay cannot yet fully companion — here an air-source
# heat pump, whose Table 4e Group 2 conservative control is not yet mapped —
# is still overlaid (log-and-continue), but the incomplete companion set is
# logged as an error so the known gap is visible (CloudWatch) rather than
# silently inheriting the replaced system's stale value.
# Act
with caplog.at_level(logging.ERROR):
main_heating_overlay_for("Air source heat pump", 0)
# Assert — the gap is reported and names the archetype.
assert "Air source heat pump" in caplog.text
def test_complete_room_heater_overlay_does_not_log_a_companion_gap(
caplog: pytest.LogCaptureFixture,
) -> None:
# Electric room heaters now resolve a full companion set (category 10 +
# control 2601), so the overlay must NOT log an incomplete-companion gap —
# guarding that the fix keeps the set complete.
# Act
with caplog.at_level(logging.ERROR):
main_heating_overlay_for("Electric room heaters", 0)
# Assert
assert "incomplete companion set" not in caplog.text
@pytest.mark.parametrize(
("main_heating_value", "code"),
[