Document Slice 2 in the persistence-fidelity migration log, plus the 7
calculator-read nested gaps the recursive guard newly surfaced (tracked
follow-up).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
CONTEXT.md gains Non-Separated / Separated Conservatory glossary terms; ADR-0036
records the mapper-owned §6.1 split + 1:1 persistence + round-trip contract; the
migration note lists the five new epc_property columns for the FE schema repo.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
PR feedback (dancafc): the SQLModel column was Optional[str], but the
domain `SapBuildingPart.wall_insulation_thickness` is Optional[Union[str,
int]] — `_api_resolve_wall_insulation_thickness` returns an int mm when the
API lodges `wall_insulation_thickness == "measured"` (SAP 10.2 §5.7 /
Table 8). The plain str column round-trips that int back as the string
"100", corrupting the Table 8 insulated-wall U-value lookup.
This column was missed in the round-trip-fidelity §1 JSONB sweep
(#1129) — its `Union[str, int]` sibling `roof_insulation_thickness` was
converted, but `wall_insulation_thickness` was not, and no 21.0.0/21.0.1
fixture lodges "measured" so the gap stayed latent. Convert to JSONB
(matching `roof_insulation_thickness` / `flat_roof_insulation_thickness`),
align the column type to Optional[Union[str, int]] (also removes a pyright
type-mismatch), record it in the migration doc §1, and add a round-trip
guard test asserting an int survives as an int (fails as '100' == 100 on
the old str column).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add epc_renewable_heat_incentive table (space_heating_kwh, water_heating_kwh +
the three insulation-impact kWh fields), wired into EpcPostgresRepository
save/get. This is the P0 gap: RenewableHeatIncentive carries the baseline
space-heating/hot-water kWh that EPC Energy Derivation consumes.
The round-trip test now asserts full deep-equality (dropped the
renewable_heat_incentive exclusion) and passes for RdSAP 21.0.0 + 21.0.1.
DB migration for the new table documented in
docs/migrations/epc-property-round-trip-fidelity.md.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Relocate EpcPropertyModel + child tables from the dying backend/ tree to
infrastructure/postgres/epc_property_table.py (re-export shim keeps
documents_parser working). Add EpcRepository port + EpcPostgresRepository with
a full reverse mapper (epc_property tables -> EpcPropertyData).
Round-trip test surfaced two fidelity gaps:
1. Union[int,str] SAP code fields were str()-coerced on save, losing the int
(API) vs str (Site Notes) distinction. Now stored as JSONB (type-preserving).
2. The schema was a partial projection. Closed the cheap gaps on the model
(heating shower/bath counts, roof_construction_type, curtain_wall_age,
addendum, mechanical_vent_duct_insulation_level, SAP 10.2 §2 ventilation
fields + a ventilation_present flag). Structural gaps tracked as follow-ups;
renewable_heat_incentive (P0, #1137) excluded from the assertion until landed.
Round-trip passes for RdSAP-Schema-21.0.0 and 21.0.1; pyright strict clean.
Migration inventory for the DB: docs/migrations/epc-property-round-trip-fidelity.md