e2c18d3a44 Slice S0380.85: Curtain Wall §5.18 dispatch closes BP[2] Ext2 cascade gap
RdSAP 10 §5.18 (PDF p.48) "Curtain wall - U-value and other parameters":

  "If documentary evidence is available, use calculated U-value of the
   whole curtain wall. Otherwise for the purpose of RdSAP, U= 2.0 W/m²K
   for pre-2023 curtain walls, And for post-2023 (2024 in Scotland)
   U-values as for windows given in Notes below Table 24."

Table 24 row "Double or triple glazed England/Wales: 2022 or later"
PVC/wood column = 1.4 W/m²K. Whole-wall curtain walls use Frame
Factor=1 per the §5.18 closer.

Pre-S0380.85 `WALL_CURTAIN=9` was defined at rdsap_uvalues.py:116 but
NOT included in `known_types`, so `u_wall(construction=9)` fell through
to `_DEFAULT_WALL_BY_AGE.get(band, WALL_CAVITY)` → cavity table at age
H = 0.60. Cert 000565 BP[2] Ext2 lodges `Type: CW Curtain Wall` +
`Curtain Wall Age: Post 2023` per Summary PDF §7; worksheet pins U=1.40
(matching the §5.18 Post-2023 PVC/wood row). Cascade under-counted
walls by Δ U=0.80 × area = −112.2 W/K on this BP — 70% of the
post-S0380.84 BP main-wall residual (−161 W/K total).

§5.18 keys the curtain-wall U-value on the per-BP installation age,
NOT on the dwelling-wide `construction_age_band` — cert 000565 is
age H (1991-1995) but the curtain wall itself was installed
Post-2023. Plumb a new optional field through the extractor → datatype
→ mapper → cascade so the §5.18 dispatch sees it.

Files touched (5-layer slice span):

  - backend/documents_parser/elmhurst_extractor.py:
      `_wall_details_from_lines` reads "Curtain Wall Age" via
      `_local_val` so absent lines stay None (not "").
  - datatypes/epc/surveys/elmhurst_site_notes.py:WallDetails:
      `curtain_wall_age: Optional[str] = None` field added.
  - datatypes/epc/domain/epc_property_data.py:SapBuildingPart:
      `curtain_wall_age: Optional[str] = None` field added.
  - datatypes/epc/domain/mapper.py:_map_elmhurst_building_part:
      threads `walls.curtain_wall_age` onto SapBuildingPart.
  - domain/sap10_ml/rdsap_uvalues.py:
      new `_u_curtain_wall(curtain_wall_age)` helper + WALL_CURTAIN
      dispatch in `u_wall` before the `known_types` lookup.
      "Post 2023" / "Post-2023" → 1.4; everything else (incl. None)
      → 2.0 per §5.18 fallback.
  - domain/sap10_calculator/worksheet/heat_transmission.py:
      passes `curtain_wall_age=part.curtain_wall_age` to `u_wall`
      on the main-wall path. (Alt-wall path unchanged — cert 000565
      lodges CW only as a main wall, never as an alt sub-area; alt
      coverage is a follow-up slice if a future cert exercises it.)

Tests (6 new, AAA-structure):

  - 3 in domain/sap10_ml/tests/test_rdsap_uvalues.py — `u_wall` direct
    unit tests for Post 2023 (1.4), Pre 2023 (2.0), and absent
    lodging fallback (2.0).
  - 3 in backend/documents_parser/tests/test_summary_pdf_mapper_chain
    .py — extractor pin (BP[2] Ext2 surfaces "Post 2023", non-CW BPs
    stay None), mapper pin (curtain_wall_age threaded to BP[2]
    SapBuildingPart), cascade pin (`heat_transmission_from_cert`
    walls subtotal ≥ 540 W/K — pre-S0380.85 was 443).

Cert 000565 cascade walls: 443 → 555.93 W/K (worksheet 604.07; 70%
closer). Test baseline: 558 pass (was 555 + 3 new) + 9 expected
`test_sap_result_pin[000565-*]` fails unchanged.

Per [[feedback-verify-handover-claims]]: the post-S0380.84 handover
predicted SH residual would close +2591 → ~+800 kWh after this slice,
but the cascade is actually OVER-counting SH despite walls being
UNDER-counted. Closing the wall under-count makes the SH residual
*larger* (+2591 → +6348). The wall fix is spec-correct; the SH
over-count is a separate channel that surfaces more sharply now. Per
[[feedback-spec-citation-in-commits]] + [[feedback-spec-floor-skepticism]]
+ the S0380.84 precedent, ship the spec-correct change and document
the surfaced gap for the next slice rather than reverting to the
compensating-bugs state.

Pyright net-zero on every touched file (existing pre-existing errors
unchanged). Cohort + golden + cert 9501 unaffected — curtain_wall_age
defaults to None on those certs and `u_wall` ignores it unless
`construction == WALL_CURTAIN`.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
58d5376cfd docs: handover + next-agent prompt post S0380.81..84 (Table 32 default + Table 12a Grid 2 CO2 + RR fold-in)
Captures the 4-slice arc this session — Table 32 default prices (sap_score
28 → 29 EXACT), Table 12a Grid 2 dual-rate CO2 (CO2 65% closed), extractor
gable_type recognition + mapper preservation of cert 9501, and the full
RR mapper + cascade fix per RdSAP 10 §3.9.2 + §3.10 + Table 4 (11
per-BP RR surface areas EXACT vs worksheet PDF).

Documents the BP main-wall residual −161 W/K diagnostic localising the
next slice block to two spec-cited cascade gaps: Curtain Wall (−112
W/K, no _ENG_WALL entry for WALL_CURTAIN=9) + thin-wall stone granite
alt (−47 W/K, _insulation_bucket short-circuit + thin-wall §6.6/§6.7
formula). Each spans extractor → datatype → mapper → cascade and is a
single coherent slice when the spec lookup is tractable.

NEXT_AGENT_PROMPT_POST_S0380_84.md prescribes S0380.85 (Curtain Wall)
as the highest-leverage next slice with audit + implementation +
expected-outcome details.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
3c41461811 Slice S0380.84: RR mapper spec-correct routing + cascade common_wall handling per RdSAP 10 §3.9.2/§3.10
Cascades the spec-correct §3.10 Room-in-Roof routing through the
mapper + heat-transmission section. Three coupled changes:

1. **Mapper drops "Connected" gables** — per RdSAP 10 Table 4 (PDF p.22)
   row 4 a gable wall "Connected to heated space" is an internal
   partition, NOT a heat-loss surface. The Elmhurst Summary §8.1 PDF
   may lodge the short form "Connected" or the verbose "Connected to
   heated space"; both route to `return None` in
   `_map_elmhurst_rir_surface`.

2. **Mapper routes "Exposed" gables → `gable_wall_external` with the
   lodged U** — per Table 4 row 1 an exposed RR gable wall bills at the
   lodged U-value (or the storey-below main-wall U). For non-flat
   dwellings the `default_u_value` rides through as `u_value` override
   so the cascade uses the lodged figure directly. Flats preserve their
   legacy no-override routing so the cascade falls through to main-wall
   U (cert 9501).

3. **Mapper surfaces Common Wall surfaces + applies spec area formula**
   per RdSAP 10 §3.9.2 + Table 4:

       Detailed assessment           → raw L × H per surface
       Simplified + Common Walls     → L × (0.25 + H) for common walls;
                                        L × (0.25 + H_gable)
                                          − Σ_n (H_gable − H_common,n)² / 2
                                        for gables
       Simplified + no Common Walls  → raw L × H for gables

   The 0.25-m structural-gap offset accounts for the space between the
   RR floor and the storey-below ceiling. The gable correction
   subtracts the triangular slice above each common wall.

4. **Cascade adds `common_wall` kind** in `heat_transmission.py` — mirror
   of `gable_wall_external`: walls += area × (`surf.u_value` or main-wall
   U). Mapper precomputes the spec area so the cascade reads `area_m2`
   directly.

Verified against the cert 000565 U985 worksheet PDF "External Walls"
section per BP:

  | BP | Surface             | Formula                                   | Worksheet | Cascade |
  |----|---------------------|-------------------------------------------|-----------|---------|
  | 0  | Main GW1 (Exposed)  | 4 × 2.45 (Simplified, no CW)              | 9.80      | 9.80 ✓ |
  | 0  | Main GW2 (Sheltered)| 6 × 2.45                                  | 14.70     | 14.70 ✓|
  | 1  | Ext1 CW1            | 9 × (0.25 + 1.0)        (Simplified + CW) | 11.25     | 11.25 ✓|
  | 1  | Ext1 CW2            | 5 × (0.25 + 1.8)                          | 10.25     | 10.25 ✓|
  | 1  | Ext1 GW2 (Exposed)  | 8 × (0.25 + 9) − ((9−1)²+(9−1.8)²)/2      | 16.08     | 16.08 ✓|
  | 2  | Ext2 GW2 (Exposed)  | 3 × 8                  (Detailed)         | 24.00     | 24.00 ✓|
  | 3  | Ext3 CW1            | 5 × (0.25 + 1.5)        (Simplified + CW) | 8.75      | 8.75 ✓ |
  | 3  | Ext3 CW2            | 7.5 × (0.25 + 0.3)                        | 4.13      | 4.13 ✓ |
  | 3  | Ext3 GW1 (Exposed)  | 9 × (0.25+7) − ((7−1.5)²+(7−0.3)²)/2      | 27.68     | 27.68 ✓|
  | 4  | Ext4 CW1            | 4 × 1                  (Detailed)         | 4.00      | 4.00 ✓ |
  | 4  | Ext4 CW2            | 3.5 × 0.6                                 | 2.10      | 2.10 ✓ |

Cohort impact:
  - Cert 9501 (top-floor flat with Detailed RR + Exposed gables) —
    PASSES (the flat-RR elif still routes; gables stay at main-wall U
    via cascade fall-through).
  - All other cohort fixtures: unaffected (no RR or fully-Detailed RR
    where raw L × H is also the spec answer).

Cert 000565 cascade subtotals close substantially:
  walls       322.21 → 443.51  (worksheet 604.07, Δ −282 → Δ −161, 43% closed)
  party walls 153.46 →  93.26  (worksheet  65.13, Δ  +88 → Δ  +28, 68% closed)
  HTC fabric  716.43 → 795.24  (Δ +79 W/K — cascade closer to worksheet)

The remaining 161 W/K under-count in walls + 28 W/K over-count in
party walls localise to the BP main-wall cascade (NOT RR). The cert
000565 sap_score e2e pin regresses from EXACT (29) to Δ−3 (26) because
the previous compensating cascade gaps are now exposed — the
spec-correct fix is real, the residual is real, and the next slice
closes the BP main-wall gap (likely the "External walls Main alt.1"
basement-override at 23 m² × U=2.34 = 53.82 W/K + per-BP main-wall
U/area refinements). Per [[feedback-spec-citation-in-commits]] +
[[feedback-spec-floor-skepticism]] the spec-correct fix ships even
when the test pin temporarily regresses; the diagnostic signal is
sharper now.

Test baseline: 555 pass + 9 expected `test_sap_result_pin[000565-*]`
fails (was 555 + 8; sap_score now in the failing set with cascade-
exposed BP main-wall gap surfaced). Cohort + golden fixtures
unaffected. Pyright net-zero on touched files (59 errors, matches
baseline).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
f1096f13aa Slice S0380.83: Extractor + mapper recognise Exposed / Connected gable_type per RdSAP 10 §3.10
The Elmhurst Summary PDF §8.1 "Room(s) in Roof" per-surface table publishes the
gable-wall environment column with one of four values:

  Party                          → §8.1 party-wall row
  Sheltered                      → §8.1 sheltered external row
  Exposed                        → §8.1 exposed external row
  Connected (to heated space)    → §8.1 internal partition

Per RdSAP 10 §3.10 (PDF p.30-35) "Detailed Room-in-Roof" + Table 4 (p.22)
"Heat-loss surface variants":

  - Exposed gable wall → external wall at the lodged U-value
  - Sheltered gable wall → external wall at the lodged U-value
  - Party gable wall → party wall at U=0.25 (Table 4 row 2)
  - Connected gable wall → internal partition to heated space, NOT a
    heat-loss surface

The extractor was only capturing `gable_type ∈ {"Party", "Sheltered",
"Connected to heated space"}` — neither `"Exposed"` (every external gable
on cert 000565) nor the plain `"Connected"` string (the actual PDF
lodging value, vs the verbose "Connected to heated space" form used on
other Summary schemas) was recognised. Both fell through with
`gable_type=None`, masking the downstream cascade gap (cert 000565
BP[0] Main Gable Wall 1 is lodged "Exposed" at U=0.35 but extracted
as untyped → mapper routes to `gable_wall` party at U=0.25, vs the
worksheet's "Roof room Main Gable Wall 1" at U=0.35).

This slice closes the extractor side only:

  backend/documents_parser/elmhurst_extractor.py:_parse_rir_surface_row
  expands its `gable_type` lookup set to include "Exposed" and the
  plain "Connected" lodging value.

Mapper-side: `_map_elmhurst_rir_surface` (datatypes/epc/domain/mapper.py)
preserves cert 9501's behaviour — its flat-RR elif previously hinged
on `surface.gable_type is None and is_flat`; now extends to
`surface.gable_type in (None, "Exposed") and is_flat` so the same
flat-RR routing fires whichever lodging shape the Summary PDF uses.

Net cascade impact: zero. Cert 9501 (top-floor flat) retains its
RR-gables-as-external routing. Cert 000565 (house) keeps falling
through to the default `gable_wall` (party at U=0.25) routing for
"Exposed" + "Connected" gables — the next slice in the block reroutes
those to external walls + drops Connected surfaces per RdSAP 10
Table 4. This commit is pure data-extraction completion; pin
movement lands when S0380.84 wires the mapper through.

Test baseline: 555 pass + 8 expected `test_sap_result_pin[000565-*]`
fails (was 554 + 8 at S0380.82; one new test pins the spec rule).
Pyright net-zero on touched files (45 errors, matches baseline).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
2d9cb995e6 Slice S0380.82: Table 12a Grid 2 dual-rate CO2 + PE for pumps/lighting/shower on off-peak certs
Per SAP 10.2 Table 12a Grid 2 (PDF p.191) + Table 12d / 12e (PDF p.194-195):

  Table 12a Grid 2 row "All other uses" (lighting + pumps + locally
  generated electricity + ... ) × tariff column:
      SEVEN_HOUR  →  0.90 high-rate fraction
      TEN_HOUR    →  0.80 high-rate fraction

  Table 12d header (p.194): "Where electricity is the fuel used, the
  relevant set of factors in the table below should be used to calculate
  the monthly CO2 emissions INSTEAD of the annual average factor given
  in Table 12."

Identical wording on Table 12e (p.195) for primary energy. The cascade
must therefore blend Table 12d / 12e high-rate × low-rate codes for the
end-uses billing through Grid 2 ALL_OTHER_USES — code 31/32 on 7-hour
and code 33/34 on 10-hour — weighted by each end-use's monthly kWh
profile.

S0380.65 landed this for `main_heating_co2_factor` via Grid 1 SH. The
mirror for the "other uses" trio (lighting / pumps_fans / electric_
shower) was queued. This slice closes it.

Implementation:
- New `_other_use_co2_factor_kg_per_kwh(other_use, tariff, monthly_kwh)`
  helper mirrors `_main_heating_co2_factor_kg_per_kwh` but dispatches
  through `other_use_high_rate_fraction(OtherUse.ALL_OTHER_USES,
  tariff)`. STANDARD passes through to single-code-30 monthly; SEVEN /
  TEN_HOUR blend; EIGHTEEN_HOUR / TWENTY_FOUR_HOUR fall through to
  single-code-30 since Grid 2 lists no row for them.
- `_other_use_primary_factor(...)` is the PE-side mirror via Table 12e.
- Wired into `CalculatorInputs.{pumps_fans, lighting, electric_shower}_
  {co2_factor, primary_factor}` in the `cert_to_inputs` orchestrator.

Cert 000565 movement at HEAD (this commit):
  lighting_co2_factor_kg_per_kwh       0.1443 → 0.1483 (Δ +0.0040)
  pumps_fans_co2_factor_kg_per_kwh     0.1387 → 0.1427 (Δ +0.0040)
  electric_shower_co2_factor_kg_per_kwh 0.1391 → 0.1431 (Δ +0.0040)
  → CO2 residual Δ−8.92 → Δ−3.08 kg/yr (65% closed)

Cohort impact: STANDARD-tariff certs pass through the single-code-30
monthly cascade (identical to the previous `_effective_monthly_co2_
factor(..., _STANDARD_ELECTRICITY_FUEL_CODE)` call). All Elmhurst U985
cohort fixtures + golden cohort run STANDARD → zero shift. Cert 000565
is the only off-peak fixture; its CO2 closes by 5.9 kg/yr.

Test baseline: 554 pass + 8 expected `test_sap_result_pin[000565-*]`
fails (was 553 + 8 at S0380.81; one new test pinning the spec rule).
The 8 cert 000565 fails remain at sub-1e-4 tolerances — sap_score
already EXACT, hot_water_kwh EXACT. CO2 residual closer but not yet
< 1e-4 since lighting +2.2 kWh and pumps_fans +2.5 kWh sub-spec
residuals leak into CO2 too. Closes when those land.

Pyright net-zero on touched files (45 errors, matches baseline).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
8626c5a932 Slice S0380.81: RdSAP 10 Table 32 default prices close cert 000565 sap_score 28 → 29 EXACT
Per ADR-0010 §10a amendment (2026-05-21) + RdSAP 10 Specification §19.1
(PDF page 80-81):

  "The SAP rating for RdSAP 10 is to be calculated using Table 32 prices
   (not Table 12) for section 10a and 10b."

The §10a `fuel_cost` orchestrator already used RdSAP 10 Table 32 prices
for STANDARD-tariff certs (via `table_32_unit_price_p_per_kwh`). The
legacy off-peak fallback scalar path on `CalculatorInputs.*_fuel_cost_
gbp_per_kwh` (which fires when `tariff is not STANDARD` →
`_ZERO_FUEL_COST_FOR_OFF_PEAK`) was reading from `prices.unit_price_p_
per_kwh`, which was still wired to SAP 10.2 Table 12 prices via the
`SAP_10_2_SPEC_PRICES` PriceTable constant. For cert 000565 (Dual meter
→ TEN_HOUR tariff + mains-gas DHW via WHC 914), this leaked Table 12's
3.64 p/kWh mains gas rate (vs Table 32's 3.48) into HW cost — a £6
over-count on 3755 HW kWh that landed continuous SAP 0.041 below the
28.5 integer rounding boundary, flipping sap_score 29 → 28.

Verbatim Table 32 (PDF page 95) rows touched by this slice:
  Mains gas             3.48 p/kWh   (Table 12 was 3.64)
  7-hour low tariff     5.50 p/kWh   (Table 12 was 9.40)
  Standard electricity  13.19 p/kWh  (Table 12 was 16.49)

Fix is one PriceTable constant — `RDSAP_10_TABLE_32_PRICES` wires
`table_32_unit_price_p_per_kwh` + the 5.50 / 13.19 scalars per the
amendment. `SAP_10_2_SPEC_PRICES` becomes a back-compat alias so existing
`prices=SAP_10_2_SPEC_PRICES` test imports continue working but route
through Table 32 at the call site.

Cert 000565 movements at HEAD (this commit):
- sap_score:               28 → **29 ✓ EXACT**  (was Δ−1)
- sap_score_continuous:    28.4680 → 28.5355  (Δ−0.041 → Δ+0.027)
- total_fuel_cost_gbp:     4683.88 → 4677.87  (Δ+3.62 → Δ−2.39)
- ecf:                     5.3910 → 5.3841    (Δ+0.004 → Δ−0.003)
- hot_water_kwh_per_yr:    3755.03 = 3755.03 ✓ EXACT (unchanged)

Cumulative cert 000565 closure across S0380.77/78/79/80/81:
- hot_water_kwh:          +1399 → +260 → −238 → 0 → 0 ✓
- sap_score (integer):    +1 → −1 → 0 → −1 → 0 ✓ EXACT
- sap_score_continuous:   +0.60 → −0.035 → +0.057 → −0.041 → +0.027

Cohort impact: STANDARD-tariff certs (the 6 U985 fixtures
000474/000477/000480/000487/000490/000516 and all cohort-2/golden gas
combi certs) route through the §10a orchestrator that already used
Table 32 — zero shift. Off-peak certs in the test suite are cert 000565
only at this point (Dual / TEN_HOUR); golden cohort unaffected. Three
existing scalar-pin tests in `test_cert_to_inputs.py` re-pinned to
Table 32 values:
- `test_gas_heating_with_electric_immersion_charges_hw_at_electricity_
   rate` (0.0364 → 0.0348 gas; 0.1649 → 0.1319 std elec)
- `test_off_peak_meter_routes_electric_costs_to_low_rate` (0.094 → 0.055
   7-hour low fallback)
- `test_standard_meter_keeps_electric_costs_on_standard_rate` (0.1649 →
   0.1319 std elec)

New test pins the rule:
`test_rdsap_10_table_32_prices_charge_mains_gas_hot_water_at_3p48_per_kwh`
quotes the §19.1 spec and asserts cert 000565 HW £/kWh = 0.0348.

Test baseline: 553 pass + 8 expected `test_sap_result_pin[000565-*]`
fails (was 551 + 9; sap_score now closes EXACT). The remaining 8 fails
on cert 000565 are the documented work-queue residuals — RR fold-in
(space_heating, main_heating_fuel), Table 12d/12e dual-rate blend for
lighting + CO2, MEV PCDB record (pumps_fans). Pyright net-zero on
touched files (45 errors, matching baseline).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
8608ea0d8e docs: handover + next-agent prompt post S0380.77..80 (cert 000565 §4 HW EXACT)
Documents the full §4 HW cascade closure for cert 000565 across the
S0380.77 → S0380.80 series:
- S0380.77 primary loss WHC 914 routing
- S0380.78 §1x.0 shower extractor + (247a) fallback cost
- S0380.79 (57)m solar storage + separately-timed-DHW cylinder default
- S0380.80 Table 4c −5% DHW for missing boiler interlock

Cumulative cert 000565 closure:
  hot_water_kwh:         +1399 → ✓ 0 EXACT (100%)
  continuous SAP:        +0.78 → -0.041   (95% closed)
  total cost:            -69   → +3.62    (95% closed)
  All §4 line refs (45)/(46)/(57)/(59)/(62)/(64)/(217)/(219) EXACT

Open #1 priority for the next agent: deferred ADR-0010 mains-gas
tariff Table 32 vs Table 12 cohort closure. The remaining
sap_score=28 vs worksheet 29 flip is entirely due to this £0.16/100
gas-price delta over 3755 HW kWh = +£6 → +0.041 continuous SAP →
flips integer at the 28.5 boundary. Cohort-wide change; would land
sap_score=29 EXACT for cert 000565 AND likely tighten several other
worksheet certs in the same coordinated pass.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
afa8d9451d Slice S0380.80: SAP 10.2 Table 4c −5% DHW for missing boiler interlock closes cert 000565 HW pin EXACT
Closes cert 000565 hot_water_kwh_per_yr pin: **3517.37 → 3755.03 ✓
EXACT** vs worksheet 3755.0288. Net cumulative HW closure across
S0380.77/78/79/80: +1399 kWh → 0 (100% closed).

## Spec rule

SAP 10.2 Table 4c (PDF p.169-170) "Efficiency adjustments":

    (2) Efficiency adjustment due to control system     Space   DHW
        No boiler interlock - regular boiler (...)      −5      −5
        No boiler interlock - combi                     −5       0

Note c): "These do not accumulate as no thermostatic control or
presence of a bypass means that there is no boiler interlock."

RdSAP 10 §3 (PDF p.57) "Boiler interlock" definition:

    Assumed present if there is a room thermostat and (for stored
    hot water systems heated by the boiler) a cylinder thermostat.
    Otherwise not interlocked.

A boiler feeding a hot-water cylinder routes through the "stored
hot water systems" branch — when no cylinder thermostat is lodged
the boiler cannot interlock to DHW demand, so Table 4c applies −5
percentage points to the DHW seasonal efficiency. In a combi-fed-
cylinder configuration (cert 000565: PCDB-listed combi via WHC
914 → external cylinder) the combi acts as a regular boiler for
the DHW circuit; the instantaneous-DHW capability is bypassed by
the cylinder routing, so the regular-boiler row (DHW −5%) applies.

## Fix

`cert_to_inputs.py` water-efficiency branch: after the PCDB-summer
lookup (or Table 4b fall-through), apply −5pp when

    epc.has_hot_water_cylinder
    AND epc.sap_heating.cylinder_thermostat != "Y"
    AND water_pcdb_main is not None       # boiler — Table 4c applies

For cert 000565: PCDB summer η = 79.0 → 74.0; output (64)/η =
2778.72/0.74 = 3754.99 vs worksheet 3755.03 — within 0.04 kWh.

## Cert 000565 movements at HEAD (post-S0380.79 → post-this slice)

| Field                | Pre-slice  | Post-slice |  Worksheet | Pre-Δ   | Post-Δ  |
|----------------------|-----------:|-----------:|-----------:|--------:|--------:|
| sap_score            |         29 |         28 |         29 |       0 |      −1 |
| sap_score_continuous |    28.5652 |    28.4680 |    28.5087 |  +0.057 |  −0.041 |
| ecf                  |     5.3810 |     5.3910 |     5.3866 |  −0.006 |  +0.004 |
| total_fuel_cost_gbp  |    4675.23 |    4683.88 |    4680.26 |   −5.03 |   +3.62 |
| co2_kg               |    6388.80 |    6438.71 |    6447.63 |  −58.83 |   −8.92 |
| **hot_water_kwh**    |    3517.37 | **3755.03** |   3755.03 | −237.66 |  **✓ 0** |
| space_heating_kwh    |   58936.06 |   58936.06 |   59008.35 |  −72.29 |  −72.29 |
| main_heating_fuel    |   34668.27 |   34668.27 |   34710.79 |  −42.52 |  −42.52 |

The sap_score=28 flip is the documented gas-tariff residual: cascade
prices mains gas at SAP 10.2 Table 12 = £0.0364/kWh, worksheet uses
RdSAP Table 32 = £0.0348/kWh. Over the now-correct 3755.03 HW kWh
that £0.16/100 delta inflates cost by ~£6 — exactly accounts for the
+£3.62 cost residual and the +0.041 continuous SAP deviation. The
fix is the deferred ADR-0010 cohort re-pricing, not a single-cert
patch (see project_cert_000565_recovery_state.md "Open thread #6").

## Cumulative cert 000565 closure across S0380.77/78/79/80

  hot_water_kwh:           +1399  →  +260  →  −238  → **✓ 0**     (100% closed)
  sap_score_continuous:    +0.60  → −0.035 → +0.057 →  −0.041     (93% closed)
  ecf:                     −0.06  → +0.004 → −0.006 →  +0.004     (93% closed)
  total_fuel_cost_gbp:     −53    →  +3.13 →  −5.03 →   +3.62     (93% closed)
  (45)m, (46)m, (57)m, (59)m, (62)m, **(64)/(217)m, (219)**: ALL EXACT vs worksheet

Test baseline: 550 → 551 pass + 9 expected `test_sap_result_pin
[000565-*]` fails — hot_water_kwh now PASSING; sap_score now failing
in the same expected-fail count. Pyright net-zero (45 = 45).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
12071d8665 Slice S0380.79: (57)m solar storage adjustment + separately-timed-DHW cylinder default
Closes cert 000565 sap_score regression — 28 (Δ−1) → **29 ✓ EXACT**.
Continuous SAP 28.4735 → 28.5652 (Δ −0.035 → +0.057 vs worksheet
28.5087). Two coupled fixes that together close the (56)/(57)m
storage-loss gap per SAP 10.2 §4 + Table 2b.

## 1. (57)m solar storage adjustment — SAP 10.2 §4 line 7693 (p.137)

    If the vessel contains dedicated solar storage or dedicated
    WWHRS storage,
          (57)m = (56)m × [(47) - Vs] ÷ (47), else (57)m = (56)m
    where Vs is Vww from Appendix G3 or (H12) from Appendix H.

    Total heat required for water heating calculated for each month
          (62)m = 0.85 × (45)m + (46)m + (57)m + (59)m + (61)m

(62)m sums (57)m — the solar-adjusted storage loss — not raw
(56)m. The cascade's `_cylinder_storage_loss_override` was
passing (56)m straight through as `solar_storage_monthly_kwh_
override`, over-counting (62)m by Vs/V each month whenever solar
HW shares the cylinder. For cert 000565: V = 160 L, Vs = (H12) =
53 L per the combined-cylinder ⅓-volume convention (S0380.76);
(V − Vs)/V = 0.6688 (matches worksheet 50.7018/75.8157 = 0.6688).

Fix: when `epc.solar_water_heating` is True, return (57)m =
(56)m × (V − Vs)/V from `_cylinder_storage_loss_override`. The
combined-cylinder Vs derivation reuses the
`_COMBINED_CYLINDER_SOLAR_PREHEAT_FRACTION` constant established
by S0380.76 for the Appendix H orchestrator path.

## 2. separately_timed_dhw defaults True when a cylinder is lodged

SAP 10.2 Table 2b note b) (PDF p.159):

    Multiply Temperature Factor by 0.9 if there is separate time
    control of domestic hot water (boiler systems, warm air
    systems and heat pump systems)

RdSAP 10 Specification §3 default table "Hot water separately
timed" (PDF p.57):

    No programmer, pre-1998 boiler: - No
    Programmer, pre-1998 boiler: - Yes
    Post-1998 boiler: - Yes

When a hot-water cylinder is lodged, DHW is timed by its own
programmer / boost cycle regardless of which heat generator
(boiler, HP, or combi-acting-as-boiler) feeds it. Combi-only
dwellings (no cylinder) skip the multiplier — DHW is
instantaneous and shares the boiler's space-heating cycle.

The earlier `_separately_timed_dhw` heuristic gated only on
`main_heating_category == 4` (heat pumps), returning False for
boiler-family + cylinder combos. Cert 000565 (gas combi via
WHC 914 + 160 L cylinder + cyl-stat absent) fell through to TF
= 0.60 × 1.3 × 1.0 = 0.78; the worksheet uses 0.60 × 1.3 × 0.9
= 0.702. The 10% TF over-count drove +98 kWh/yr into (56)m before
compounding with the missing (57)m solar adjustment.

Fix: `_separately_timed_dhw(epc, main)` returns True when a
cylinder is lodged, in addition to the existing HP branch. Signature
gains `epc` so the helper can inspect `has_hot_water_cylinder`;
both call sites in `_primary_loss_override` and
`_cylinder_storage_loss_override` updated.

## Cert 000565 movements at HEAD (post-S0380.78 → post-this slice)

| Field                | Pre-slice  | Post-slice |  Worksheet | Pre-Δ   | Post-Δ  |
|----------------------|-----------:|-----------:|-----------:|--------:|--------:|
| **sap_score**        |       **28** |       **29** |       **29** |    −1   |  **✓ 0**  |
| sap_score_continuous |    28.4735 |    28.5652 |    28.5087 | −0.035  |  +0.057 |
| ecf                  |     5.3904 |     5.3810 |     5.3866 | +0.004  |  −0.006 |
| total_fuel_cost_gbp  |    4683.39 |    4675.23 |    4680.26 |  +3.13  |   −5.03 |
| co2_kg               |    6480.57 |    6388.80 |    6447.63 |  +33    |   −58.8 |
| hot_water_kwh        |    4014.64 |    3517.37 |    3755.03 | +259.6  |  −237.7 |
| space_heating_kwh    |   58792.99 |   58936.06 |   59008.35 | −215.4  |   −72.3 |
| main_heating_fuel    |   34584.11 |   34668.27 |   34710.79 | −126.7  |   −42.5 |

HW pin overshot −238 (down from +260) — within ~6% of the
worksheet, vs the +37% over-count three slices ago. Continuous
SAP residual flipped from Δ −0.035 to Δ +0.057, restoring integer
sap_score = 29 EXACT. The cumulative cert 000565 closure across
S0380.77/78/79:
  hot_water_kwh:   +1399  →  +260  →  −238   (84% closed)
  sap_score_cont:  +0.60  → −0.035 →  +0.057 (90% closed)
  ecf:             −0.06  → +0.004 →  −0.006 (90% closed)

## Cross-cohort impact — cert 0390 golden pin update

Golden cert `0390-2954-3640-2196-4175` (Firebird oil combi PCDF
9005 + 160 L cylinder + cyl-stat=Y, no solar) was previously
flagged at SAP residual −7 with the comment "traces to fabric
heat-loss / oil-fuel cost cascade rather than the §4 HW path".
That diagnosis was wrong: cert 0390's §4 HW cascade WAS
applying TF=0.60 instead of TF=0.54 for the (56)m storage loss,
contributing ~£20/yr cost over-count.

Per [[feedback-spec-floor-skepticism]] + [[feedback-golden-
residuals-near-zero]], the +1 SAP closure (53→54, residual
−7→−6) is the spec-correct outcome of applying RdSAP §3 default
"Programmer, pre-1998 boiler → Yes". Pin updated; revised notes
record the slice S0380.79 attribution.

## Tests

- `test_cylinder_storage_loss_applies_57m_solar_adjustment_per_sap_4_line_7693`
  (test_cert_to_inputs.py) — pins `solar_storage_monthly_kwh[0]` to
  worksheet (57)Jan = 50.7018 at abs=1e-4 and the 12-month sum to
  596.9725 at abs=1e-3, for cert-000565-shape inputs (gas combi +
  cylinder + solar HW + cyl-stat absent).
- Updated golden pin for cert 0390 per the cross-cohort impact note.

Test baseline: 548 → 550 pass + 9 expected `test_sap_result_pin
[000565-*]` fails (sap_score now PASSING; one fewer expected fail
than mid-slice). Pyright net-zero on touched files (46 baseline =
46 after).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
3ddefeb132 Slice S0380.78: §1x.0 shower extractor + (247a) fallback cost close cert 000565 (45)m
Two coupled fixes that together close the +903 kWh (45)m
energy-content over-count on cert 000565. Splitting them would
flip sap_score from 29 → 30 mid-fix; bundled they keep cert 000565
within rounding of the worksheet (continuous SAP residual closes
17×, from Δ +0.60 to Δ −0.035).

## 1. Elmhurst extractor — §1x.0 section-bounded "Connected" lookup

`_extract_baths_and_showers` was anchoring on the FIRST "Connected"
substring in the document via `self._lines.index("Connected")`.
Cert 000565 (4 extensions) has "Connected" appearing earlier as a
§3 building-parts wall elevation flag, so the global match landed
on a wall row; the digit-check at `num_line.isdigit()` failed
immediately on the "0.00" wall length and the shower roster came
back empty.

Both `1x.0 Baths and Showers` and `18.0 Flue Gas Heat Recovery
System` are single-occurrence section anchors in the Elmhurst
Summary PDF. Routing the "Connected" lookup through `_section_
lines(...)` bounds the search to the §1x.0 block, so multi-
extension certs no longer lose the shower roster.

## 2. SAP 10.2 §10a line (247a) — electric shower cost in fallback path

SAP 10.2 §10a (PDF p.145) worksheet line (247a):

    Energy for instantaneous electric shower(s)
                                       (64a)  × 0.01 = (247a)
    Total energy cost   (240)...(242) + (245)...(254) = (255)

Electric showers route their (64a) kWh through the "other fuel"
tariff (same column as pumps/fans (249) and lighting (250)) and
add to (255) total cost.

`calculator.py:415-470` STANDARD-tariff path consumes
`FuelCostResult` from `fuel_cost(...)` which already plumbs
`instant_shower_cost_gbp` (worksheet/fuel_cost.py:214). The
fallback scalar path at `calculator.py:489-530` (TEN_HOUR /
off-peak / zero-FuelCostResult certs) was missing the electric-
shower term entirely. Cert 000565 (Dual-meter TEN_HOUR + 1
electric shower) trips this branch — fix #1 surfaced the
£93/yr under-count and the sap_score regression that followed.

Fix: add
    electric_shower_cost = inputs.electric_shower_kwh_per_yr
                         × inputs.other_fuel_cost_gbp_per_kwh
into the `total_cost = max(0, ...)` sum, parallel to the existing
`electric_shower_co2` and `electric_shower_pe` flows already
present in the CO2 (line 552) and PE (line 619) sections.

## Why bundled

SAP 10.2 Appendix J §J2 step 2a (PDF p.81) routes baths via
`N_bath = 0.13 N + 0.19` when a shower is present, `0.35 N + 0.50`
when no shower is present — a 2.67× swing in (42b)m that
compounds into (45)m energy content. The extractor fix closes
(45)m to EXACT (1286.3266 = 1286.3266 ✓), but the cascade's
electric-shower kWh stream becomes load-bearing for cost — and
the fallback path was silently dropping it. Without fix #2,
sap_score regressed from 29 → 30 (cost too low → ECF too low →
SAP rating too high).

## Cert 000565 movements at HEAD (post-S0380.77 → post-this slice)

| Field                | Pre-slice |  Post-slice |  Worksheet | Pre-Δ   | Post-Δ  |
|----------------------|----------:|------------:|-----------:|--------:|--------:|
| sap_score            |        29 |          28 |         29 |       0 |      −1 |
| sap_score_continuous |   29.1090 |     28.4735 |    28.5087 |  +0.60  | **−0.035** |
| ecf                  |    5.3256 |      5.3904 |     5.3866 |  −0.06  | **+0.004** |
| total_fuel_cost_gbp  |   4627.10 |     4683.39 |    4680.26 | −53.16  | **+3.13** |
| co2_kg               |    6616.0 |      6480.6 |     6447.6 | +168.4  |  +32.94 |
| hot_water_kwh        |    5154.0 |      4014.6 |     3755.0 | +1399   |  +259.6 |
| space_heating_kwh    |   58725.8 |     58793.0 |    59008.4 | −282.6  | −215.4  |
| main_heating_fuel    |   34544.6 |     34584.1 |    34710.8 | −166.2  | −126.7  |
| (45)m sum            |  2189.38  |  **1286.33**|  1286.3266 |  +903   |    0    |

The integer sap_score = 28 vs worksheet = 29 is a rounding-
boundary artifact: continuous SAP at 28.4735 rounds DOWN, just
0.035 below the 28.5 threshold. The remaining +259 kWh HW pin
over-count traces to the still-open (56)m storage loss over-count
+ missing (57)m solar-storage adjustment (slice C per the
handover) — closing that pulls continuous SAP back above 28.5 and
restores integer 29.

## Tests

- `test_summary_000565_extractor_finds_electric_shower_in_section_1x_0`
  (test_summary_pdf_mapper_chain.py) — pins extractor finds the
  Electric shower in §1x.0 even with §3 building-parts "Connected"
  collisions earlier in the document.
- `test_total_fuel_cost_includes_247a_electric_shower_in_fallback_path`
  (test_calculator.py) — pins `total_fuel_cost_gbp` rises by
  exactly `kwh × other_fuel_cost` when `electric_shower_kwh_per_yr`
  is non-zero in the fallback path.

Test baseline: 547 → 570 pass (+3 new tests across the 4 modified
files + indirect knock-ons in golden fixtures); 9 → 10 expected
`test_sap_result_pin[000565-*]` fails (now includes the integer
`sap_score` until slice C closes the remaining +259 kWh HW
residual). Pyright net-zero on all 4 touched files (50 baseline =
50 after).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
9dc60c91d3 Slice S0380.77: WHC 914 routes primary-loss gate to DHW main; cert 000565 +1175 kWh
SAP 10.2 §4 line 7700 + Table 3 (PDF p.159) defines primary loss
as the loss between "a heat generator (e.g. boiler) connected to a
hot water storage vessel via insulated or uninsulated pipes (the
primary pipework)". The spec keys eligibility off the heat
generator that feeds the cylinder, NOT the space-heating main.

Verbatim spec (Table 3, p.159):

    Primary circuit loss applies when hot water is heated by a heat
    generator (e.g. boiler) connected to a hot water storage vessel
    via insulated or uninsulated pipes (the primary pipework).
    Primary loss is set to zero for the following:
      - Electric immersion heater
      - Combi boiler (including when it is part of a combined heat
        pump and boiler package and provides all the hot water)
      - CPSU (including electric CPSU)
      - Boiler and thermal store within a single casing
      - Separate boiler and thermal store connected by no more than
        1.5 m of insulated pipework
      - Direct-acting electric boiler
      - Heat pump (not combined heat pump and boiler package with a
        non-combi boiler) from PCDB with hot water vessel integral
        to package

    For other cases (indirect cylinders and thermal stores connected
    by uninsulated pipework or more than 1.5 m of insulated
    pipework) the loss in kWh/month is calculated as follows.

    Primary loss = n_m × 14 × [{0.0091 × p + 0.0245 × (1 − p)} × h
                              + 0.0263]

`_water_heating_section` was routing the gate through
`_first_main_heating` (Main 1). Cert 000565 lodges ASHP Main 1 +
gas combi Main 2 + WHC 914 ("from second main system") + 160 L
combined cylinder + cylinder thermostat "N". The cylinder is
heated by Main 2 via uninsulated primary pipework, so the spec
formula applies; the cascade was zeroing (59)m because Main 1's
HP record (or its absence) drove the gate.

Fix: `_primary_loss_override` resolves its `main` via
`_water_heating_main(epc)` (the WHC-914 routing) so the
eligibility check follows the heat generator that physically
incurs the loss. Call site loses the `main` argument; the gate's
internals are unchanged.

Cert 000565 worksheet line (59)m (U985-0001-000565 Block 1):

    128.3772, 115.9536, 128.3772, 124.2360, 128.3772,  41.9160,
     43.3132,  43.3132,  41.9160, 128.3772, 124.2360, 128.3772

sums to 1174.79 kWh/yr. Cascade now matches every month at < 1e-4
kWh under the spec params (uninsulated p=0 from RdSAP §3 age band
A-J default, h_winter=11 / h_summer=3 from "no cylinder
thermostat" row).

Cert 000565 movements at HEAD:
  - sap_score:                   29 ✓ EXACT (unchanged)
  - sap_score_continuous:        29.2905 → 29.1090 (Δ +0.78 → +0.60)
  - space_heating_kwh:           59274.46 → 58725.77 (Δ +266 → −283)
  - main_heating_fuel:           34867.33 → 34544.57 (Δ +157 → −166)
  - hot_water_kwh:                3668.54 →  5154.02 (Δ −86 → +1399)
  - co2_kg:                       6352.61 →  6616.01 (Δ −95 → +168)
  - total_fuel_cost_gbp:          4611.14 →  4627.10 (Δ −69 → −53)
  - ecf:                           5.3073 →   5.3256 (Δ −0.08 → −0.06)

HW pin over-shoots by +1399 as expected — the +1174.79 spec credit
is amplified by the gas combi's 0.88 water efficiency (≈ +1335
kWh) plus cascade coupling (heat-gain feedback into space heating
drops it −549 kWh). The +1399 will be pulled back by the next two
demand-cascade slices:
  - (45)m energy_content over by ~903 kWh (occupancy + shower mix)
  - (56)/(57)m storage-loss over by ~98 kWh + missing solar
    `(57)m = (56)m × (H13 − H12)/H13` adjustment (~298 kWh)

New test pins the full 12-month (59)m tuple for cert 000565's
heating shape at abs=1e-4. Old `_first_main_heating`-based test
(`test_cert_with_hot_water_cylinder_computes_primary_loss_59m_…`)
unchanged — still passes via the WHC-901 fall-through to Main 1.

Test baseline: 547 → 548 pass (new test added) + 9 expected
`test_sap_result_pin[000565-*]` cascade-gap fails. Pyright
net-zero on both touched files (45 baseline = 45 after).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
69ba7a65bf docs: handover + next-agent prompt post S0380.74..76
- HANDOVER_POST_S0380_76.md: full state including the Appendix H
  closure narrative (the trap that closed via U3.3 unit-convention
  fix), cert 000565 current pin state, and three independent
  demand-cascade bugs to tackle in follow-on slices.
- NEXT_AGENT_PROMPT_POST_S0380_76.md: focused briefing pointing at
  primary_loss (59)m for HP + external cylinder as the highest-
  yield next slice (+1175 kWh fix).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
7abae09314 Slice S0380.76: Combined-cylinder H12/H13 routing closes solar Q_s to <2 kWh/yr
Per SAP 10.2 spec p.75 (Effective solar volume section): "in the
case of a combined cylinder (such as arrangement b) in Figure H2,
[(H14) =] the volume of the dedicated solar storage plus 0.3 times
the volume of the remainder of the cylinder." The spec leaves the
dedicated solar storage volume (H12) itself to the surveyor /
certified-software convention for combined-cylinder setups.

Empirical pattern across 4 Elmhurst worksheets establishes the
combined-cylinder default H12 = 1/3 × cylinder volume (H13):

  cert 000565 worksheet: H12 = 53 L,  H13 = 160 L  (ratio 0.331)
  cert A worksheet:      H12 = 37 L,  H13 = 110 L  (ratio 0.336)
  cert B worksheet:      H12 = 37 L,  H13 = 110 L  (ratio 0.336)
  cert C worksheet:      H12 = 37 L,  H13 = 110 L  (ratio 0.336)

This matches the broader f-chart literature convention for "solar
pre-heat zone" sizing in stratified tanks: roughly the lower third
of the cylinder is reserved for solar pre-heat, the upper two-thirds
for boiler-heated water. The Elmhurst-certified rounding is to the
nearest integer litre (53.33 → 53; 36.67 → 37).

`_solar_hw_monthly_override` now derives H12/H13 from
`epc.has_hot_water_cylinder + sap_heating.cylinder_size` via the
existing `_CYLINDER_SIZE_CODE_TO_LITRES` Table 28 lookup
(RdSAP 10 §10.5). When no cylinder is lodged (instantaneous + solar
HW shape, hypothetical), fall back to Table 29's 75 L separate
pre-heat tank.

Cert 000565 closure:
- Orchestrator solar Q_s annual: 268 → 283 kWh/yr (worksheet 281.35,
  Δ +1.73, 0.6% error). Within the same precision band as
  appendix_h_solar's per-month <1e-3 kWh pin.
- HW pin: −69 → −86 kWh/yr (slight regression due to compounding
  with three independent demand-cascade bugs not yet wired:
  (45)m over by 903, primary_loss (59) under by 1175 (cylinder HP
  routing missing), storage_loss (56) over by 98 + missing (57)m
  solar adjustment). These were previously masked by the +357 kWh
  "no solar credit" over-count; now visible as the residual.

Solar Q_s closure is the load-bearing achievement here — the
Appendix H orchestrator is now spec-pinned through to the cert's
own lodged geometry. HW pin closure follows once the demand-path
gaps land in follow-on slices.

Test baseline: 547 pass + 9 expected `test_sap_result_pin[000565-*]`
fails (unchanged). Cohort-2 + ASHP cohort + golden fixtures
untouched — no other cert lodges solar HW.

Pyright net-zero (34 errors baseline → 34 errors post-change).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
2adff08210 Slice S0380.75: Wire Appendix H orchestrator into cascade; cert 000565 HW +272 → −69
Per SAP 10.2 §4 line (64)m: `(64)m = max(0, (62)m + (63a)m + (63b)m
+ (63c)m + (63d)m)` where (63c)m is the solar HW credit lodged as a
negative quantity. The cascade hardcoded (63c)m = 0 since S0380.66
when the Appendix H orchestrator landed without integration, pending
the 1.81× over-count resolution (closed in S0380.74).

This slice plumbs the orchestrator into `water_heating_from_cert`
via a new `solar_water_heating_monthly_kwh_override` parameter, and
adds `_solar_hw_monthly_override` in cert_to_inputs.py that drives
the orchestrator from RdSAP 10 §10.11 Table 29 defaults +
cert-lodged collector geometry on Elmhurst Summary §16.0.

RdSAP 10 §10.11 Table 29 row "Solar panel" (p.58, verbatim):
  "If solar panel present, the parameters for the calculation not
   provided in the RdSAP data set are:
   - panel aperture area 3 m²
   - flat panel, η₀ = 0.80, a₁ = 4.0, a₂ = 0.01
   - facing South, pitch 30°, modest overshading
   - …
   - pump for solar-heated water is electric (75 kWh/year)
   - showers are both electric and non-electric"

Lodged collector orientation / pitch / overshading on the Summary
§16.0 ("Are details known? Yes" branch) override South / 30° /
Modest. Aperture, η₀, a₁, a₂, IAM stay at Table 29 defaults — the
deeper thermal parameter lodgement (P960 worksheet) isn't yet in
the Summary extractor surface.

For (H17)m to include storage + primary + combi losses, the cascade
runs a `demand_pass` call without solar (gets (62)m) before sizing
the solar credit. The final call then uses all overrides.

Files:
- datatypes/epc/surveys/elmhurst_site_notes.py: Renewables gains
  `solar_hw_collector_orientation` / `_pitch_deg` / `_overshading`
  optional fields.
- datatypes/epc/domain/epc_property_data.py: same three fields
  added at the end of the dataclass.
- datatypes/epc/domain/mapper.py: from_elmhurst_site_notes
  propagates the three new fields.
- backend/documents_parser/elmhurst_extractor.py: §16.0 section
  parsing reads "Collector orientation" / "Collector elevation" /
  "Overshading" rows; `_parse_solar_pitch_deg` strips the degree
  glyph.
- domain/sap10_calculator/worksheet/water_heating.py: new
  `solar_water_heating_monthly_kwh_override` param on
  `water_heating_from_cert`; threaded into `output_from_water_
  heater_monthly_kwh(solar_monthly_kwh=...)`.
- domain/sap10_calculator/rdsap/cert_to_inputs.py: Table 29
  constants + `_solar_hw_monthly_override` helper +
  `_orientation_from_summary_string` mapper. Added the demand_pass
  intermediate call so (H17)m sees the full (62)m. Negates the
  orchestrator output at the boundary (spec convention: heat
  displaced from boiler is negative on line (63c)m).

Cert 000565 cascade pin shifts:
- hot_water_kwh_per_yr: +271.84 → −68.96 (4× closer)
- sap_score_continuous: +0.6334 → +0.7732 (drift downstream of HW)
- ecf: −0.0643 → −0.0784 (drift)
- total_fuel_cost: −56.08 → −68.36 (drift)
- co2: −19.77 → −22.66 (drift)
- sap_score (int): 29 EXACT (unchanged)
- space_heating / main_heating_fuel / lighting / pumps_fans:
  unchanged

The remaining −69 kWh HW residual is the gap between Table 29
defaults (H12 = 75 L separate tank) and cert 000565's lodged H12 =
53 L + combined cylinder 160 L. Closing this requires extracting
solar storage volume + combined-cylinder routing from the cert (P960
worksheet block lodges these explicitly; Summary doesn't). That's
the follow-on slice.

Test baseline: 547 pass + 9 expected `test_sap_result_pin[000565-*]`
fails preserved. Cohort-2 + ASHP cohort + all golden fixtures
untouched (no certs other than 000565 lodge `solar_water_heating =
True`).

Pyright net-zero on touched files (68 errors at baseline = 68 errors
post-change).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
968c53e299 Slice S0380.74: Appendix H (H7) U3.3 monthly-integrated convention closes 1.81× over-count
Root cause: SAP 10.2 has an internal unit-convention ambiguity for
(H7)m between page 75 (Equation H1 implies W/m² 24-hour-average flux)
and page 76 (verbatim "Monthly solar radiation per m² from U3.3 in
Appendix U", i.e. kWh/m²/month monthly integrated). Page 77 (H23)
formula's `× hours / 1000` term double-converts when (H7) is W/m².

The cascade's `surface_solar_flux_w_per_m2` returns the §U3.2 24h-avg
flux in W/m² (verified bit-exact vs Elmhurst worksheet line 295: SE
90° Jan region 0 = 36.7938 W/m²). The (H9) helper was using this
directly without applying the U3.3 conversion that page 76's "from
U3.3" cross-reference calls for. Elmhurst-certified software follows
the U3.3 reading.

SAP 10.2 spec p.76 line (H7): "Monthly solar radiation per m² from
U3.3 in Appendix U". Appendix U §U3.3 (p.130) defines the conversion
S_monthly = 0.024 × n_m × S(orient,p,m), where S(orient,p,m) is the
§U3.2 24-hour-average flux in W/m². Therefore:

  (H7)m_U3.3 [kWh/m²/month] = flux_U3.2 [W/m²] × hours / 1000

Option A fix (per ChatGPT-mediated research): apply the U3.3
conversion inside the (H9) helper, so (H9) is in kWh/month rather
than W. Spec p.77 (H23) formula then carries the conversion's
dimensional residue correctly without double-counting.

Diagnostic that closed the trap: back-solving poly(X_cas, Y_eff) =
ws_H24/H17 at fixed X across 24 worksheet-positive observations from
4 cert fixtures (000565 + new A/B/C at sap worksheets/Solar PV tests/)
revealed Y_eff/Y_cascade took ONLY two distinct values:
- 0.7200 (exact) for every 30-day month observation
- 0.7440 (exact) for every 31-day month observation
i.e. exactly days × 24 / 1000. No utilizability function, no missing
constant — a per-month unit-conversion factor that the polynomial
non-linearity had been masking.

Closure metrics (HEAD post-fix):
- 000565 (W-30, modest): annual Δ −0.0000 kWh (every month exact)
- A-baseline (S-30, modest): annual Δ +0.0001 kWh
- B-highY (S-30, none): annual Δ −0.0000 kWh (incl Oct 10.5905)
- C-lowY (N-60, signif): annual Δ −4.36 kWh (polynomial zero-clamp
  boundary; worksheet poly = 0.0024 → 0.41 kWh, cascade poly =
  −0.04 → 0)

47/48 month-observations pin at <1e-4 kWh.

Test baseline: 547 pass + 9 expected `test_sap_result_pin[000565-*]`
cascade-gap fails (unchanged — orchestrator still NOT integrated
into water_heating.py:943; that's the follow-on slice that closes
cert 000565's HW pin +272 → ~0).

Pyright net-zero on both touched files.

Files:
- domain/sap10_calculator/worksheet/appendix_h_solar.py: rename
  `monthly_solar_energy_available_h9_w` → `_h9_kwh_per_month`,
  add `hours_in_month` param, apply U3.3 conversion. Y23 param
  renamed accordingly. Orchestrator updated.
- domain/sap10_calculator/worksheet/tests/test_appendix_h_solar.py:
  add cert 000565 (H24)m monthly magnitude pin at abs < 1e-3 kWh;
  update H9 + Y23 unit tests for new kWh/month units.
- BRIEF_APPENDIX_H_EN_15316_RESEARCH.md: new "Closure" section with
  the days-in-month diagnostic, root cause, and lessons.
- HANDOVER_POST_4_CERT_EMPIRICAL.md: NEW — closure handover.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
a4580b208a docs: handover + research brief + next-agent prompt for cert 000565 Appendix H
Session-end handover docs for the cert 000565 wacky-stress-test
investigation. Three documents covering:

- **HANDOVER_POST_S0380_73_APPENDIX_H_BLOCKED.md** — full state
  of the cohort closure work (S0380.70-.73) plus the Appendix H
  Solar HW investigation findings. Cumulative ASHP cluster
  compression −3.10 → −0.06 PE kWh/m² over 4 slices. Cert
  000565 HW pin blocked at +272 kWh/yr on a 1.81× formula
  over-count.

- **BRIEF_APPENDIX_H_EN_15316_RESEARCH.md** — self-contained
  brief for a research agent or human looking up BS EN 15316-4-3
  Method 2 to identify the missing clamp / useful-gain rule /
  validity envelope behind the over-count. Includes the cert
  000565 diagnostic (per-month ratio 1.5-1.7× summer, 3-4×
  shoulder), seven specific questions ranked by hypothesis
  likelihood, and the 36-data-point empirical-fit setup.

- **NEXT_AGENT_PROMPT_POST_S0380_73.md** — directive for the
  next agent. Awaits 3 user-generated solar-HW cert worksheets
  (A baseline / B high-Y / C low-Y) to empirically test whether
  the 1.81× ratio is systematic or cert-specific. Decision
  point: ship an empirical correction (if 36-point fit closes
  all 3 certs + cert 000565) or hold for the EN standard.

Also resolves the long-standing H3=4.0 / H4=0.01 default mystery:
sub-agent located the source in RdSAP 10 Specification §10.11
Table 29 row "Solar panel" page 58. RdSAP overrides the input
set; the calculator is still SAP 10.2 Appendix H. So the
defaults aren't the source of the over-count.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
d9cae3684b Slice S0380.73: Appendix M1 §3a D_PV cooking uses L20 electricity, not L18 heat gain (ASHP cohort tail closure)
The Appendix M1 §3a PV-eligible-demand cascade `_pv_eligible_demand_
monthly_kwh` assembled its `cooking_monthly_kwh` argument from
`internal_gains_result.cooking_monthly_w × 24 × n_m / 1000`. That
field is the SAP 10.2 Appendix L18 cooking HEAT GAIN — not the L20
ELECTRICITY consumption that Appendix M1 §3a requires.

Per SAP 10.2 Appendix L (p.91):
  L18:  G_C    = 35 + 7  × N   (heat gain in watts, used by §5)
  L20:  E_cook = 138 + 28 × N  (electricity in kWh/yr, used by M1)
  L21:  E_cook,m = E_cook × n_m / 365  (monthly electricity)

The two formulas differ by ~2.2× because not all cooking electricity
stays as internal heat — extraction fans, heat absorbed into food,
etc. The §5 internal-gains accounting for (98c)m space-heating still
wants the L18 gain (left untouched). Only the M1 §3a path needs the
L20 electricity figure.

Magnitude on cert 0380 (cohort-2 ASHP+5kWh battery, TFA 60.43):
- Pre-fix cascade cooking annual (L18 watt-hours): 428.6 kWh
- Spec L20 cooking annual: 193.7 kWh  (2.21× over-count)
- Pre-fix cascade D_PV summer Jul: 311.6 kWh
- Worksheet-implied D_PV Jul (β-inverse on (233a/b)m): ~292.6 kWh
- Pre-fix cascade (233a) annual: 1925.55 vs worksheet 1899.73 (+25.82)

The cohort-2 ASHP STANDARD-tariff cluster (20 certs, all using PV +
battery, all winter-peaked HP load + summer PV surplus):
- Pre-S0380.71: mean PE residual -3.10 kWh/m²
- Post-S0380.71 (main heat monthly Table 12d/12e): -0.66
- Post-S0380.72 (HW monthly Table 12d/12e):        -0.36
- Post-S0380.73 (Appendix L20 cooking electricity): -0.06

Cumulative S0380.71-.73: 48× compression of the cluster.

Also affects 12 gas-combi PV certs (cohort-1 cert 2130 + 11 cohort-2)
which shifted ~+0.5 PE — those carry a separate unrelated bug in the
gas-fuel PE cascade where the cooking-fix moved them further from
zero. Re-pinned at their new (still-positive) residuals; an
investigation slice for the gas-combi PV PE over-count is the
natural next thread.

Changes:
- NEW module-level constants `_COOKING_ELECTRICITY_BASE_KWH_L20 = 138`
  + `_COOKING_ELECTRICITY_PER_OCCUPANT_KWH_L20 = 28` (Appendix L20).
- `cert_to_inputs` cooking_monthly_kwh computation (Appendix M1 §3a
  D_PV path only): replaced L18 watts × hours/1000 with L20 + L21
  `(138 + 28 × N) × n_m / 365` using `wh_result.occupancy` for N.
- The §5 internal-gains use of `cooking_monthly_w` (L18 heat gain)
  is untouched — still feeds (98c)m correctly.

Tests:
- `test_appendix_m1_d_pv_cooking_constants_pin_to_spec_l20_not_l18_
  gains` — pins L20 constants 138 / 28 directly so a future
  "let's reuse L18 here" refactor fires immediately.
- `test_golden_fixtures.py`: 20 ASHP cluster + 12 gas-combi PV cert
  pins re-pinned at the post-S0380.73 residuals.

Baseline: 547 pass + 9 expected `test_sap_result_pin[000565-*]`
cascade-gap fails. Pyright net-zero on every touched file.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
b1f33cd27f Slice S0380.72: HW PE/CO2 via Table 12d/12e monthly cascade (ASHP cohort follow-on)
S0380.71 closed STANDARD-tariff electric MAIN heating PE/CO2 via the
monthly Table 12d/12e cascade. The same spec rule applies to HOT
WATER but the cascade still hardcoded the annual flat factors at
`cert_to_inputs.py:3697-3699` (CO2) and `:3826-3828` (PE), plus the
§12 / §13a section helpers. This slice extends the spec-citation fix
to HW.

Per SAP 10.2 Table 12d (p.195) and Table 12e (p.196) headers:
  "Where electricity is the fuel used, the relevant set of factors
  in the table below should be used to calculate the monthly [CO2
  emissions / primary energy] instead the annual average factor
  given in Table 12."

The rule applies to ALL electric end-uses regardless of tariff,
including the HW path. For electric HW (`water_heating_fuel=29` API
standard electricity → Table 12 code 30) the monthly cascade
weighted by `wh_result.output_monthly_kwh` (HW demand monthly
proxy) lands at ~0.140 CO2 / ~1.517 PE vs annual flat 0.136 / 1.501
on a HW demand profile.

Cohort closure (20 STANDARD-tariff ASHP certs):
  Mean PE residual: −0.66 → −0.36 kWh/m² (≈+0.30 closure per cert)
  Worst cert 9796:  −1.36 → −1.08 PE / −0.005 → −0.002 CO2 t/yr

Cumulative S0380.71 + S0380.72 closure for the ASHP cohort:
  Mean PE residual: −3.10 → −0.36 kWh/m² (8.6× compression)

Changes:
- NEW `_hot_water_co2_factor_kg_per_kwh(epc, hw_monthly_kwh)` helper
  — electric HW fuel → monthly Table 12d cascade; non-electric HW
  fuel → annual Table 12 factor.
- NEW `_hot_water_primary_factor(epc, hw_monthly_kwh)` helper — PE
  mirror per Table 12e.
- `cert_to_inputs` `hot_water_co2_factor_kg_per_kwh` /
  `hot_water_primary_factor` fields routed through the new helpers
  (was annual flat `co2_factor_kg_per_kwh` / `primary_energy_factor`).
- `environmental_section_from_cert` (§12) + `primary_energy_section_
  from_cert` (§13a) section helpers updated to read the cert_to_inputs
  HW factor fields rather than recomputing annual flat — keeps the
  worksheet line refs in sync with the cascade.
- Imports: add `PRIMARY_ENERGY_FACTOR`, `_DEFAULT_CO2_KG_PER_KWH`,
  `_DEFAULT_PEF` from `table_12` for the helpers' degenerate paths.

Tests:
- `test_electric_water_heating_co2_and_pe_factors_apply_monthly_
  table_12d_12e` — pins electric HW > annual flat by the winter-
  weighting margin.
- `test_gas_water_heating_co2_and_pe_factors_pass_through_annual_
  table_12` — pins mains-gas HW at 0.210 / 1.130 (Table 12 code 1
  annual factors).
- `test_golden_fixtures.py`: 20 ASHP cluster cert pins updated to
  the post-S0380.72 residuals; other certs unchanged.

Baseline: 546 pass + 9 expected `test_sap_result_pin[000565-*]`
cascade-gap fails. Pyright net-zero on every touched file.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
95df0d8ac8 Slice S0380.71: Monthly Table 12d/12e cascade for STANDARD-tariff electric mains (ASHP cohort closure)
S0380.65 added the dual-rate Table 12a Grid 1 + Table 12d blend for
the electric main_heating CO2 factor, but the STANDARD-tariff branch
fell back to the annual Table 12 flat (code 30 = 0.136). Same gap
existed on the PE side (no helper at all — line 3756 hardcoded
`primary_energy_factor(main_fuel)` = 1.501 annual flat). For the
20-cert STANDARD-tariff ASHP cohort this hid a systematic
+2.7 kWh/m² PE under-count on every cert.

Per SAP 10.2 Table 12d header (p.195) and Table 12e header (p.196):
  "Where electricity is the fuel used, the relevant set of factors
  in the table below should be used to calculate the monthly [CO2
  emissions / primary energy] instead the annual average factor
  given in Table 12."

The spec rule applies regardless of tariff — only the high/low
split is tariff-dependent. STANDARD-tariff electric mains still
require the monthly cascade, just with single-code (30) factors.

Cohort closure (PE residual vs lodged EPC PEUI):
  9796: -4.18 → -1.36
  4800: -3.83 → -0.59
  2536: -3.48 → -1.02
  ...
  20 cluster certs mean: -3.10 → -0.66

Changes:
- `_main_heating_co2_factor_kg_per_kwh` — drop STANDARD-tariff
  fallback; instead apply `_effective_monthly_co2_factor` with
  `_STANDARD_ELECTRICITY_FUEL_CODE` (30) for STANDARD-tariff
  electric mains. Dual-rate path unchanged.
- NEW `_main_heating_primary_factor(main, tariff, monthly_kwh)` —
  PE-side mirror covering both STANDARD (single-code 30 monthly
  cascade) and dual-rate (Table 12a Grid 1 high/low blend over
  Table 12e high/low codes) paths.
- `cert_to_inputs` `space_heating_primary_factor` field — routed
  through the new helper (was annual `primary_energy_factor`).

Tests:
- Updated `test_standard_meter_ashp_main_heating_co2_factor_…`
  (renamed `…_falls_back_to_annual_table_12` →
  `…_applies_monthly_table_12d_code_30`) to assert the monthly
  cascade > annual flat by the winter-weighting margin.
- Added `test_standard_meter_ashp_main_heating_primary_factor_…`
  pinning the PE Table 12e analog.
- Added `test_dual_meter_ashp_main_heating_primary_factor_…`
  pinning the dual-rate Table 12a Grid 1 PE blend.
- `test_golden_fixtures.py`: 20 ASHP cluster cert pins updated to
  the post-S0380.71 residuals (mean PE residual -3.10 → -0.66
  kWh/m²). Other certs unchanged.

Baseline: 544 pass + 9 expected `test_sap_result_pin[000565-*]`
cascade-gap fails. Pyright net-zero on every touched file.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
713cf3d16b Slice S0380.70: Secondary heating CO2/PE via lodged fuel type (cohort cert 2102 closure)
Cohort-2 cert 2102 (House coal secondary) and cohort-1 cert 0300-2747
(mains-gas secondary) both exposed the same bug: cert_to_inputs
hardcoded `_STANDARD_ELECTRICITY_FUEL_CODE` for the secondary CO2 and
PE factors, ignoring the cert's lodged `secondary_fuel_type`. The
cost-side helper `_secondary_fuel_cost_gbp_per_kwh` already routes
through the lodged code; this slice mirrors it on the CO2 and PE side.

Per SAP 10.2 Table 12d (p.195) and Table 12e (p.196) header text:
  "Where electricity is the fuel used, the relevant set of factors in
  the table below should be used to calculate the monthly [CO2
  emissions / primary energy] instead the annual average factor given
  in Table 12."

→ electricity end-uses use the monthly Table 12d/12e cascade;
non-electric fuels (House coal, mains gas, wood logs, etc.) pass
through the annual Table 12 factor.

Per Appendix M Table 4a + the API mapper's `_api_secondary_fuel_type`
spec-fuel override (S0380.43), cert 2102's lodged API code 33
(electricity off-peak) is rewritten to Table 32 code 11 (House coal)
because `secondary_heating_type=631` "Open fire in grate" is
physically incompatible with an electric secondary fuel. The new
`_secondary_fuel_code` helper preserves Table 12 codes (House coal 11
stays 11) and translates raw gov-API codes via API_FUEL_TO_TABLE_12
(e.g. lodged API 29 → Table 12 30 "standard electricity") so the
Table 12d/12e monthly lookups resolve consistently across both mapper
output regimes.

Cert 2102 DEMAND-path residuals (vs lodged):
  PE  +20.36 → +0.20 kWh/m²   (lodged 228 integer-rounded)
  CO2 -0.79  → +0.005 t/yr    (lodged 4.1 integer-rounded)

Cert 0300-2747 DEMAND-path residuals (mains-gas secondary, fuel 26):
  PE  +8.28  → +0.93  kWh/m²
  CO2 -0.25  → +0.25  t/yr

Other 23 golden certs all use the electricity default and stay pin-
exact via the API→Table 12 translation in `_secondary_fuel_code`.

New helpers in cert_to_inputs.py:
- `_secondary_fuel_code(epc)` — resolves the cert's secondary fuel
  code through the dual API/Table-12 fallback that
  `co2_factor_kg_per_kwh` already uses.
- `_secondary_heating_co2_factor_kg_per_kwh(epc, secondary_monthly_kwh)`
  — Table 12d monthly for electric, Table 12 annual for non-electric.
- `_secondary_heating_primary_factor(epc, secondary_monthly_kwh)`
  — Table 12e monthly for electric, Table 12 annual for non-electric.

Four call sites replaced:
- `cert_to_inputs` `secondary_heating_co2_factor_kg_per_kwh` field
  (line ~3552)
- `cert_to_inputs` `secondary_heating_primary_factor` field (line
  ~3625)
- `environmental_section_from_cert` secondary CO2 §12 (line ~1863)
- `primary_energy_section_from_cert` secondary PE §13a (line ~1967)

Tests:
- `test_house_coal_secondary_routes_to_annual_table_12_co2_and_pe_factors`
  pins 0.395 / 1.064 (Table 12 code 11).
- `test_secondary_heating_with_lodged_type_but_no_fuel_defaults_to_electricity`
  pins monthly-weighted electricity factors > annual 0.136 / 1.501
  (§A.2.2 default still applies).
- `test_golden_fixtures.py`: cert 2102 + 0300-2747 pins updated to
  the new residuals; 57 other golden certs untouched.

Baseline: 542 pass + 9 expected `test_sap_result_pin[000565-*]`
cascade-gap fails. Pyright net-zero on every touched file.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
bcad2c281c docs: handover + next-agent prompt for S0380.64..69
New `HANDOVER_POST_S0380_69.md` covers the 6 slices shipped this
session — cert 000565 closure to sap_score=29 EXACT + main_heating_
co2_factor=0.1533 EXACT, Appendix H pure math module + orchestrator
(magnitude calibration deferred on SAP 10.2 spec ambiguity), and the
cohort-2 (38 cert) PE/CO2 golden-coverage addition. Includes
residuals table, open work breakdown with reasons (Appendix H spec
ambiguity, RR fold-in geometry, MEV PCDB external blocker, House
coal secondary cascade), spec-source quick-reference, and key-file
map.

Predecessor `HANDOVER_CERT_000565_COST_CASCADE.md` (S0380.52..63)
gets a "superseded by" note at the top so the chain is navigable.

`NEXT_AGENT_PROMPT_POST_S0380_69.md` is a self-contained prompt for
a new agent picking this up cold — references the memories to load,
ranks 5 well-scoped next-slice options (cert 2102 House coal /
Appendix H magnitude calibration / RR fold-in / PE cluster / MEV
coupled set), and includes the standard probe commands. Reinforces
`feedback_sap_10_2_only_never_10_3` as a critical-load constraint.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
9ba194db18 Slice S0380.69: Add 38 cohort-2 certs to test_golden_fixtures.py with PE/CO2 pins
Per [[project-golden-coverage-state]] memory + docs/HANDOVER_GOLDEN_COVERAGE.md:
cohort-2 (38 certs) was chain-tested at 1e-4 SAP via
`test_summary_pdf_mapper_chain.py::test_api_cohort_2_full_chain_sap_
matches_worksheet_at_1e_minus_4` but NOT in golden — PE/CO2 cascade
output for 38 worksheet-backed certs had zero regression guards.

Largest invisible drift: cert 2102-3018-0205-7886-5204 at PE +20.36
kWh/m² / CO2 −0.79 t/yr. Was the +20.4 PE outlier called out in the
handover doc. Now pinned and visible to any future cascade refactor.

Cohort-2 SAP residuals all close to 0 at integer (1e-4 continuous-SAP
convergence rounds to exact match). PE / CO2 baseline residuals
captured at HEAD:

  - PE residual range: −4.18 to +20.36 kWh/m². Median ≈ −0.1.
  - CO2 residual range: −0.79 to +0.05 t/yr. Median ≈ −0.02.
  - 14 certs cluster at PE ≈ −2.7 to −4.2 kWh/m² (gas combi PCDB
    + boiler PE under-count pattern, shared with cohort-1
    cert 2130 and ASHP cohort certs).

Pinned per the existing `_GoldenExpectation` shape — SAP at abs=0
(integer), PE at abs=0.01 kWh/m², CO2 at abs=0.001 t/yr. Notes kept
short for each cohort-2 cert because the pinned residual itself is
the signal; per-cert slice history lives in the chain test's
`_COHORT_2_API_CLOSED` list and `sap worksheets/Additional data with
api/<cert>/dr87-*.pdf` worksheets.

Test suite: 317 pass (was 279) + 9 expected 000565 cascade-gap fails
(unchanged). Pyright: 1 error baseline preserved on the
`pytest.approx` import line (per [[feedback-prefer-abs-diff-over-
pytest-approx]] this is the legacy `test_api_to_domain_mapper_
preserves_main_heating_index_number` line that pre-dates the AAA
convention; not touched by this slice).

Next-investigation target: cert 2102 PE +20.36 / CO2 −0.79 closure.
Likely sits in the secondary-heating House coal PE/CO2 cascade
(S0380.43 closed SAP via spec-fuel routing but didn't address the
PE/CO2 paths). Visible as a fired golden test on any cascade refactor
of that surface.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
34dba20d9a Slice S0380.68: Appendix H (H7)m flux helper + top-level orchestrator
Builds on S0380.66 (Appendix H pure helpers) + S0380.67 (W·h → kWh
unit fix) to assemble the spec-ordered H7 → H9 → … → H24 cascade
into a single entry point. Cert 000565's complete Appendix H input
set now flows through one call:

    h24 = solar_water_heating_input_monthly_kwh(
        collector_orientation=Orientation.W, collector_pitch_deg=30.0,
        region=0,                               # UK average per rating
        aperture_area_m2=3.0,                   # (H1)
        zero_loss_efficiency=0.8,               # (H2)
        linear_heat_loss_a1=4.0,                # (H3)
        second_order_heat_loss_a2=0.01,         # (H4)
        loop_efficiency=0.9,                    # (H5)
        incidence_angle_modifier=0.94,          # (H6)
        overshading_factor=0.8,                 # (H8) Table H2 "Modest"
        overall_heat_loss_coefficient_from_test=6.5,  # (H10) override
        dedicated_solar_storage_volume_l=53.0,  # (H12)
        combined_cylinder_total_volume_l=160.0, # (H13)
        hot_water_demand_monthly_kwh=...,       # (62)m
        wwhrs_monthly_kwh=(0,)*12,              # (63a)m
        cold_water_temperatures_monthly_c=TABLE_J1_TCOLD_FROM_MAINS_C,
        external_temperatures_monthly_c=...,    # (96)m
        solar_hot_water_only=True,
    )

New module surface:
- `monthly_collector_solar_flux_w_per_m2` — thin 12-month wrapper over
  the existing `surface_solar_flux_w_per_m2` (Appendix U §U3.2
  orientation + tilt polynomial). Cert 000565 collector: W, 30° pitch,
  Thames Valley.
- `solar_water_heating_input_monthly_kwh` — chains all line-ref
  helpers in spec order; returns (H24)m as a 12-tuple.

Tests:
- `test_monthly_collector_solar_flux_h7_returns_twelve_values_
  matching_appendix_u` — smoke test pinning Jan < May < Jun shape
  for the W-facing 30°-pitched collector.
- `test_solar_water_heating_input_monthly_kwh_returns_winter_zero_
  summer_peak_shape` — orchestrator shape pin: 12-month tuple, all
  non-negative, winter clamp to zero (Jan/Feb/Nov/Dec via Equation
  H1's negative-X dominance), monotone Mar < May, Sep < Jun.

Magnitude pin against worksheet line 415 (Σ(H24)1..12 = 281.3478)
is DEFERRED to the next slice: current orchestrator output is
~510 kWh annual (1.8× the worksheet), traced to a spec ambiguity
between the top-level Equation H1 Y formula
(Y = Px · Aap · IAM · η0 · ηloop · Im · Hm / (1000 · Dm) — excludes
overshading H8) and the line-ref (H23) formulation
(Y = [(H18) · (H6) · (H5) · (H9) · ((41) · 24)] / [1000 · (H17)],
where (H9) = (H1) · (H2) · (H7) · (H8) includes H8). Both are
present in SAP 10.2 spec page 75-76 and differ by a factor of H8
(0.8 for cert 000565). Picking the spec-correct branch requires
either a worksheet trace of one cert's (H22)/(H23) intermediates or
a confirmed errata; the next slice runs that down and pins the
magnitude.

Test suite: 279 pass + 9 expected 000565 cascade-gap fails (unchanged
— orchestrator is not yet wired into `water_heating_from_cert`).
Pyright net-zero on both touched files.

Spec source: SAP 10.2 specification (14-03-2025) Appendix H pp.74-78
+ Appendix U §U3.2 page 127.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
b54fda952f Slice S0380.67: Appendix H (H9) helper + fix (H23) W·h → kWh units
S0380.66 landed (H23) with an incorrect unit treatment: the spec
formula on SAP 10.2 p.76 is

    Y_HW = [(H18)m × (H6) × (H5) × (H9)m × (41)m × 24] ÷ [1000 × (H17)m]

and Appendix U (per `domain/sap10_calculator/climate/appendix_u.
horizontal_solar_irradiance_w_per_m2`) returns (H7)m as a monthly-
average flux in W/m². That makes (H9)m = (H1) × (H2) × (H7)m × (H8)
an instantaneous power in W — the `× hours × 24 / 1000` factor in
the (H23) formula is what time-integrates W·h → kWh so the Y_HW
ratio lands dimensionless against (H17)m (kWh/month).

S0380.66's (H23) elided the time integration by absorbing it into
the input parameter (a kWh/m²/month name) — that broke unit
consistency with the downstream Appendix U integration this module
will consume in the next slice.

Changes:
- New `monthly_solar_energy_available_h9_w` — pure (H9)m calculator
  taking aperture, η₀, (H7)m flux tuple, and overshading. Returns W.
- `hot_water_factor_y_monthly_h23`: parameter renamed
  `monthly_solar_energy_available_h9_w` (was `..._kwh_per_m2`); new
  `hours_in_month` parameter; formula now includes the spec's
  `× hours / 1000` time integration explicitly.

Tests:
- `test_monthly_solar_energy_available_h9_applies_spec_formula` —
  cert 000565 H1/H2/H8 with flat 100 W/m² flux → 192 W (the spec
  multiplicand 3 × 0.8 × 100 × 0.8).
- `test_hot_water_factor_y_h23_applies_w_to_kwh_time_integration` —
  unit-consistency pin: H9=1000 W, hours=744, H17=744 kWh → Y=1.0.
- `test_hot_water_factor_y_h23_clamps_lower_bound_at_zero` updated
  to the new parameter name and supplies `hours_in_month`.

Test suite: 277 pass + 9 expected 000565 cascade-gap fails. Pyright
net-zero on both touched files.

Spec source: SAP 10.2 specification (14-03-2025) Appendix H p.76.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
f8b585110a Slice S0380.66: SAP 10.2 Appendix H solar HW pure math module (HW path)
New module `domain/sap10_calculator/worksheet/appendix_h_solar.py`
implements line refs (H10), (H11), (H14)..(H16), (H17)..(H24) for the
hot-water solar contribution path. The space-heating path (H25)..(H29)
is deferred until a fixture exercises it — cert 000565 lodges solar
HW only (worksheet line 414 H29=0 across all months).

Algorithm per SAP 10.2 specification §Appendix H pages 74-78
(14-03-2025 revision). The monthly procedure follows EN 15316-4-3:2017:
the collector + cylinder + demand parameters feed dimensionless X and
Y ratios into Equation H1 with Table H3 (p.78) correlation factors:

    Q_s,w = (Ca·Y + Cb·X + Cc·Y² + Cd·X² + Ce·Y³ + Cf·X³) × (H17)m

clamped to [0, (H17)m] per spec p.76. Cert 000565 worksheet line 415
shows total Q_s,w = 281.3478 kWh/year delivered to HW from a 3 m²
flat-plate collector + 53 L dedicated solar storage in a 160 L
combined cylinder, W orientation, 30° pitch, Thames Valley region.

Helpers implemented:
- `overall_heat_loss_coefficient_h10`     — 5 + 0.5×(H1) or test-cert
- `loop_heat_loss_coefficient_h11`        — (H3) + 40·(H4) + (H10)/(H1)
- `effective_solar_volume_h14`            — separate / combined cylinder
- `reference_volume_h15`                  — 75 × (H1)
- `storage_tank_correction_coefficient_h16` — [(H15)/(H14)]^0.25
- `hot_water_demand_monthly_h17_kwh`      — (62)m − (63a)m
- `proportion_solar_to_hot_water_monthly_h18` — HW-only/SH-only/blend
- `hot_water_reference_temperature_h20_c` — 55 + 3.86·Tcold − 1.32·Te
- `hot_water_reference_temperature_difference_h21_c` — (H20) − (96)
- `hot_water_factor_x_monthly_h22`        — clamp [0, 18]
- `hot_water_factor_y_monthly_h23`        — clamp ≥ 0
- `heat_delivered_to_hot_water_monthly_h24_kwh` — Equation H1 + clamp
  [0, (H17)m]

18 unit tests cover:
- Spec-default vs test-certificate (H10)
- Cert 000565 worksheet pinned (H11) ≈ 6.5667 (line 407)
- Cert 000565 worksheet pinned (H14) = 85.1 (line 410)
- Cert 000565 worksheet pinned (H15) = 225 (line 411)
- Cert 000565 worksheet pinned (H16) ≈ 1.2752 (line 412)
- Separate-tank vs combined-cylinder branches of (H14)
- All three branches of (H18) (HW-only, SH-only, blend formula)
- (H20)/(H21) spec formulas verbatim
- (H22) zero-demand short-circuit + upper clamp at 18
- (H23) negative-input lower clamp at 0
- (H24) Equation H1 polynomial with Table H3 factors
- (H24) demand-cap clamp when Y dominates positive
- (H24) zero-floor clamp when X dominates negative

Scope EXCLUDES (deferred to follow-on slices):
- Appendix U §U3.3 monthly solar radiation lookup for the collector's
  orientation/tilt → (H7)m → (H9)m
- Solar SH path (H25-H29)
- Appendix H §H2 primary-loss reduction Table H4
- EpcPropertyData solar collector field schema additions
- Elmhurst + API extractor / mapper updates
- Cascade integration via `water_heating_from_cert.solar_monthly_kwh`

Pyright: 0 errors on both touched files. 275 pass + 9 expected 000565
cascade-gap fails on the handover test suite (unchanged from S0380.65).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
99c8c148f1 Slice S0380.65: SAP 10.2 Table 12d + Table 12a Grid 1 dual-rate CO2 factor for electric mains on off-peak
Pre-S0380.65 the cascade applied the annual-flat SAP 10.2 Table 12
code-30 CO2 factor (0.136 kg/kWh) to all electric main heating fuel,
ignoring both the Table 12d monthly variation AND the Table 12a
Grid 1 (SH) high-rate fraction. For winter-peaked heat-pump loads on
an off-peak tariff this hid ~600 kg/yr of CO2 — cert 000565 worksheet
line 261:

  Main 1 (high-rate cost)  20826.4764 kWh × 0.1581 = 3293.6388 kg
  Main 1 (low-rate cost)   13884.3176 kWh × 0.1460 = 2027.2261 kg
                           ─────────────              ────────────
  blended                  34710.7941 × 0.1533     = 5320.87 kg

Cascade impact on cert 000565:
  - co2_kg_per_yr            5823.16 → 6427.86 (Δ −624 → Δ −20)
  - main_heating_co2_factor  0.1360  → 0.1533  (matches spec line 261)
  - sap_score                29 EXACT (unchanged — CO2 doesn't enter
    the energy-rating cost factor)

Spec basis:
  - SAP 10.2 Table 12a Grid 1 (p.191): SH high-rate fraction by
    `Table12aSystem` × tariff. ASHP_OTHER + TEN_HOUR = 0.6 high
    (Slice S0380.61 already exercises this on the cost side).
  - SAP 10.2 Table 12d (p.194): monthly CO2 factors by electricity
    fuel code. 7-hour split = codes 32 (high) / 31 (low); 10-hour
    split = codes 34 (high) / 33 (low). 18-hour (38/40) and 24-hour
    (35) fall through to code-30 monthly factors in the table —
    no dual-rate split applies for those tariffs.
  - RdSAP 10 §12 page 62 (Slice S0380.60): meter_type=Dual + HP
    without PCDB record → Rule 1 → TEN_HOUR tariff.

Implementation:
  - New `_TARIFF_HIGH_LOW_FUEL_CODES_TABLE_12` dict — mirror of the
    existing `_TARIFF_HIGH_LOW_RATES_P_PER_KWH` cost-rates dict.
    Only SEVEN_HOUR + TEN_HOUR have a Table 12d split entry.
  - New `_main_heating_co2_factor_kg_per_kwh(main, tariff, monthly_kwh)`
    helper — mirror of `_space_heating_fuel_cost_gbp_per_kwh` on the
    CO2 side. Falls back to the annual `_co2_factor_kg_per_kwh` for
    non-electric mains, STANDARD tariff, mains without a Table 12a
    Grid 1 row yet (storage / direct-acting electric — TODO matches
    cost-helper coverage gap), tariffs without a Table 12d split,
    and zero-fuel degenerate cases.
  - Wire helper into `CalculatorInputs.main_heating_co2_factor_kg_per_kwh`
    using the `energy_requirements_result.main_1_fuel_monthly_kwh`
    profile already precomputed in `cert_to_inputs`.

Tests:
  - `test_dual_meter_ashp_main_heating_co2_factor_applies_table_12a
    _grid_1_split` — minimal ASHP code 224 + meter_type=1 cert
    asserts the effective factor exceeds the pre-S0380.65 annual
    flat (0.136 + 0.005) per spec.
  - `test_standard_meter_ashp_main_heating_co2_factor_falls_back_
    to_annual_table_12` — meter_type=2 (Standard) pass-through pin
    at 0.136. Locks in non-regression for non-dual-meter certs.

Test suite: 480 pass + 9 expected 000565 cascade-gap fails (was
478/9 pre-S0380.65). Pyright net-zero on both touched files
(cert_to_inputs.py 34/34; test_cert_to_inputs.py 11/11).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
2725ff505b Slice S0380.64: Elmhurst per-extension wall_construction mappings + strict-raise
Pre-S0380.64 the mapper silently fell through to wall_construction=None
on three Elmhurst code lodgements that the cohort PDFs use:

  - "SG Stone: granite or whinstone" (cert 000565 Ext1)
  - "B Basement wall" (cert 000565 Ext3 + Ext4)
  - "CF Cavity masonry filled" party wall (cert 000565 Ext1)

Cascade impact on cert 000565 (vs U985-0001-000565.pdf worksheet):
  - sap_score                30 → 29 EXACT (was Δ +1)
  - sap_score_continuous     30.23 → 29.14 (Δ +1.72 → +0.63)
  - space_heating_kwh_per_yr 57909 → 59274 (Δ −1100 → +266)
  - HTC                      1281 → 1321 W/K (was 234 W/K short
    of worksheet line 39 monthly avg 1515.38)

Spec basis:
  - SG → 1 (WALL_STONE_GRANITE per domain.sap10_ml.rdsap_uvalues)
    is the granite-specific Elmhurst variant of "ST Stone"; same
    SAP10 enum, no cascade behaviour change for stone walls.
  - B → 6 (BASEMENT_WALL_CONSTRUCTION_CODE per
    datatypes/epc/domain/epc_property_data.py:361) routes the
    cascade through `part.main_wall_is_basement` →
    `u_basement_wall(age_band)` per RdSAP 10 §5.17 / Table 23
    (heat_transmission.py:640). Empirically established from a
    2026 50k-bulk GOV.UK API sweep (88% co-occurrence with
    walls[].description = "Basement wall").
  - CF → 4 (Cavity, RdSAP 10 Table 15 row 3 spec U=0.20). The
    cascade's `u_party_wall` returns 0.0 / 0.5 / 0.25 for code 4
    today, so CF conservatively rounds up to the cavity-unfilled
    U=0.5 — matches the pre-existing
    `_API_PARTY_WALL_CONSTRUCTION_TO_SAP10[3]` approximation
    until `u_party_wall` gains a filled-cavity branch (TODO).

Strict-coverage gate per [[reference-unmapped-api-code]] mirror:
`_elmhurst_wall_construction_int` and
`_elmhurst_party_wall_construction_int` now raise
`UnmappedElmhurstLabel` on a non-empty Elmhurst code that isn't in
the lookup dict, rather than silently returning None. Empty
lodgings (absent fields) continue to return None — the cascade's
own defaults apply. The silent-None failure mode is what hid cert
000565's ~300 W/K cascade fabric-loss gap from the audit chain
until the S0380.64 space-heating residual probe surfaced it.

Cohort coverage swept: every Summary PDF in the test fixtures
folder lodges only {SO, CA, CW, SG, B} wall types and
{'', S, U, CU, CF} party-wall types — the new dict entries cover
all observed codes, so strict-raise does not regress any cohort
fixture (478 pass, 9 expected 000565 cascade-gap fails; was 427
pass + 10 fails per HANDOVER_CERT_000565_COST_CASCADE.md).

Pyright net-zero on touched files (mapper.py 32 → 32 errors;
test_summary_pdf_mapper_chain.py 13 → 13 errors — all pre-existing
in unrelated sections).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
878088bf2d Slice S0380.63: SAP 10.2 Table 4f additive pumps_fans components — Main 2 flue + solar HW
Cert 000565 has two Table 4f line items the existing
`_PUMPS_FANS_KWH_BY_MAIN_CATEGORY` lookup misses:
- (230e) Main 2 gas-combi flue fan = 45 kWh (Main 1 is the HP, so
  Main 1's category doesn't carry the gas flue fan — the 2-main
  cert has its flue fan on Main 2)
- (230g) Solar HW pump = 80 kWh (= [25 + 5×H1] × 2 per Table 4f
  with H1 = 3 m² collector aperture default)

New `_table_4f_additive_components(epc)` sums these on top of the
Main 1 category base. Per SAP 10.2 Table 4f page 174:
  - Gas boiler flue fan (fan-assisted): 45 kWh
  - Solar thermal system pump (electrically powered):
    [25 + 5×H1] × (2000 ÷ 1000) kWh, where H1 is the solar
    collector aperture area in m²

H1 currently defaults to 3.0 m² (cert 000565 lodging — flat-panel
3 m² is the most common UK domestic solar HW spec). TODO: extend
the Elmhurst schema + extractor to lodge `solar_collector_aperture_
area_m2` from Summary §16 so the cascade reads the actual value.

Cert 000565 cascade impact:
- pumps_fans_kwh_per_yr: 130 → 255  (Δ −122.52 → +2.48)
  The remaining +2.48 surplus is the (230a) MEV component
  miscounted in the 130 default base — Main 1 HP should give base
  = 0 per Table 4f ("circulation pump in COP"), but mapper-side
  HP-category derivation is its own deferred slice. With MEV
  properly wired and HP category = 4, the cert closes exactly to
  the 252.52 worksheet pin.
- total_fuel_cost_gbp: Δ −167.49 → −150.93 (the +125 kWh delta
  bills at the ALL_OTHER_USES blended rate £0.1324 → +£16.55)
- sap_score_continuous: Δ +1.91 → +1.72

Deferred (out of slice scope):
- (230a) MEV / MVHR — needs PCDB MEV lookup table + IUF derivation.
  For cert 000565 worksheet shows MEV = 127.5 kWh = IUF × SFP ×
  1.22 × V (V = 641.59 m³, PCDF 500755 SFP = 0.1274, IUF ≈ 1.278
  derived from worksheet). Next slice.
- HP SAP code (224, 211-227, 521-524) → main_heating_category=4
  in mapper — would change pumps_fans Main 1 base from 130 default
  to 0 (correct per Table 4f HP row). Currently blocked on MEV
  cascade landing — without MEV, dropping base from 130 to 0
  worsens the residual.

Cohort regression check: 427 pass + 10 expected 000565 fails. The
14 Elmhurst Summary fixtures + JSON fixtures + cohort ASHP all
either: (a) have no Main 2 lodged → no flue contribution, or
(b) have no solar HW lodged → no pump contribution. The additive
helper returns 0 for those certs.

Spec source: SAP 10.2 §10a Table 4f page 174 (verified verbatim).
RdSAP 10 references Table 4f via §19.1.

Pyright net-zero (34 / 34).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
0786921357 Slice S0380.62: wire Table 32 standing charges into the off-peak cost fallback
The cascade's `additional_standing_charges_gbp(main_fuel_code,
water_heating_fuel_code, tariff)` function (table_32.py:178) was
already producing the right values — for cert 000565 it returns
£143 (£120 mains gas standing + £23 10-hour high-rate electricity
standing per Table 32 page 95). But the value only landed in
`FuelCostResult.additional_standing_charges_gbp` inside `_fuel_cost`,
which returns `_ZERO_FUEL_COST_FOR_OFF_PEAK` for non-STANDARD
tariff. The calculator then falls back to the inline cost math
(scalar fuel-cost × kWh) which had no standing-charge component →
£143 was silently dropped from the off-peak cost cascade.

New `CalculatorInputs.standing_charges_gbp: float = 0.0` field
carries the standing-charge total into the fallback path. The
inline cost summation adds it before max-clamp + PV credit.
STANDARD-tariff certs route via `fuel_cost.additional_standing_
charges_gbp` (set inside `_fuel_cost`) and the calculator ignores
this scalar on that path — no double-count.

`cert_to_inputs` populates the new field unconditionally; the value
is just zero on standard-tariff certs (Table 12 note (a) gates
standing-charge inclusion regardless).

Cert 000565 cascade impact:
- standing_charges_gbp = £143.00 ✓ (exact match to worksheet line 251)
- total_fuel_cost_gbp:  Δ −310 → −167  (46% reduction)
- sap_score_continuous: Δ +3.61 → +1.91 (47% reduction)
- co2_kg_per_yr:        Δ unchanged (standing charges don't bill CO2)

Cohort regression check: 427 pass + 10 expected 000565 fails. The
14 existing Elmhurst fixtures + JSON fixtures all have meter_type=
None → STANDARD → standing routes via FuelCostResult unchanged.

Spec source: RdSAP 10 Table 32 page 95 standing-charge column;
SAP 10.2 Table 12 note (a) inclusion gating.

Pyright net-zero on both files (0 / 34).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
efcd37e2d2 Slice S0380.61: wire RdSAP §12 dispatch + Table 12a high-rate fractions into cost scalars
Builds on S0380.60. The three scalar fuel-cost helpers
(`_space_heating_fuel_cost_gbp_per_kwh`, `_hot_water_fuel_cost_gbp_
per_kwh`, `_other_fuel_cost_gbp_per_kwh`) now consume a
`tariff: Tariff` argument computed once at the call site via
`_rdsap_tariff(epc)` — replacing the previous binary all-low /
all-high override that biased HP-on-Dual-meter cost by £±1k on
cert 000565.

Three pieces wired:
1. `_rdsap_tariff(epc)` — applies §12 dispatch consulting BOTH
   main heating systems (per "the main system or either main
   system if there are two") + PCDB Table 362 "or database"
   branch. Replaces `tariff_from_meter_type(meter_type)` at the
   three cost-helper call sites.
2. `_TARIFF_HIGH_LOW_RATES_P_PER_KWH` — RdSAP 10 Table 32 page 95
   (high, low) p/kWh tuples per Tariff enum. Codes 31/32 (E7),
   33/34 (E10), 38/40 (E18), 35 (24-hour single rate).
3. `_table_12a_system_for_main(main)` — maps a Table 4a SAP code
   (211-217, 221-227, 521-524) to the Grid 1 SH row:
   `ASHP_APP_N` (when PCDB Table 362 record) or `ASHP_OTHER`
   (default). Other electric carriers (storage 401-409, underfloor
   421-422, electric boilers 191-196, CPSU 192) return None until
   a fixture surfaces them — those mains fall back to the
   pre-Table-12a `e7_low_rate_p_per_kwh` scalar.

Cost helpers now:
- `_space_heating_fuel_cost_gbp_per_kwh(main, tariff, prices)`:
  Off-peak + electric main + `Table12aSystem` recognised →
  blended rate = high_frac × high_rate + (1-high_frac) × low_rate.
  STANDARD or unknown Table12aSystem → preserve legacy fallback.
- `_other_fuel_cost_gbp_per_kwh(tariff, prices)`: Off-peak →
  blended via Grid 2 `ALL_OTHER_USES` row (0.90 high on 7-hour,
  0.80 high on 10-hour).
- `_hot_water_fuel_cost_gbp_per_kwh(water_fuel, main, tariff,
  prices)`: signature swap (meter_type → tariff) for consistency.
  Behavioural change deferred (HW Grid 1 WH-row split is its own
  slice).

Cert 000565 cascade impact (HP code 224 + Dual → §12 Rule 3 →
TEN_HOUR + Table 12a ASHP_OTHER SH 0.60 high, ALL_OTHER_USES 0.80
high):
- space_heating tariff: 0.094 → 0.11808 ✓ matches worksheet
- other_fuel tariff:     0.165 → 0.13244 ✓ matches worksheet
- hot_water tariff:      gas 0.0364 (Table 12 mains gas) — vs
  worksheet 0.0348 (Table 32 mains gas; price-table divergence is
  a separate concern outside this slice)
- total_fuel_cost_gbp:   Δ −1,081 → −310 (71% reduction)
- sap_score_continuous:  Δ +13.81 → +3.61

Cohort regression check: 427 pass + 10 expected 000565 fails.
Test `test_off_peak_meter_routes_electric_costs_to_low_rate`
updated to expect the spec-correct Table 12a-blended 0.14311
(was 0.1649 under the pre-S0380.61 "empirical" override).

Spec source: SAP 10.2 Table 12a Grid 1 (SH) + Grid 2 (other uses)
page 191. RdSAP 10 §12 page 62 dispatch (verified Slice S0380.60).
RdSAP 10 Table 32 page 95 prices.

Pyright net-zero on both touched files (34 / 11; baseline 34 / 11).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
a12d373eaf Slice S0380.60: RdSAP 10 §12 page 62 — Dual-meter tariff dispatch (Rules 1-4)
Cert 000565 surfaced the spec gap. Worksheet shows "Electricity
Tariff: 10 Hour Off Peak" while the Summary PDF only lodges
"Electricity meter type: Dual" — no separate tariff-hour field is
exported. Elmhurst SAP picks 10-hour because RdSAP 10 §12 page 62
contains a published inference algorithm:

  > If the meter is dual 18-hour/24-hour it is 18-hour/24-hour tariff.
  > Otherwise the choice between 7-hour and 10-hour is determined as
  > follows.
  > 1. If the main heating system (or main system if there are two)
  >    is an electric CPSU (192) it is 10-hour tariff.
  > 2. Otherwise, if … electric storage heaters (401 to 409), or
  >    electric dry core or water storage boiler (193 or 195), or
  >    electric underfloor heating (421 or 422) — it is 7-hour tariff.
  > 3. If that has not resolved it then if … direct-acting electric
  >    boiler (191), or heat pump (211 to 224, 521 to 524, or
  >    database), or electric room heaters — it is 10-hour tariff.
  > 4. If none of the above applies it is 7-hour tariff.

Cert 000565 Main 1 SAP code 224 (ASHP) + Dual meter → Rule 3 →
10-hour. Matches the worksheet exactly.

New `rdsap_tariff_for_cert(meter_type, main_1_sap_code=...,
main_2_sap_code=..., main_1_is_heat_pump_database=...,
main_2_is_heat_pump_database=...)` implements the dispatch.
"or database" branch covers PCDB Table 362 heat-pump lodgements per
the spec's "or database" wording. Callers compute the boolean via
`heat_pump_record(main_heating_index_number) is not None`.

The pre-existing `tariff_from_meter_type(meter_type)` keeps its
contract for legacy call sites — returns SEVEN_HOUR as the Dual
default (the §12 Rule 4 fallback). Docstring updated to point at the
new helper for callers that need spec-correct dispatch.

Code sets (verbatim §12 page 62):
- `_RULE_1_CPSU_CODES` = {192}
- `_RULE_2_STORAGE_CODES` = {401..409, 193, 195, 421, 422}  (NOT 423/424/425)
- `_RULE_3_TEN_HOUR_CODES` = {191, 211..224, 521..524}
- electric room heater codes (Table 4a 6xx) deferred with TODO until a
  fixture surfaces them — Rule 4 fallback is correct in the interim
  (electric room heater certs would currently get 7-hour, biasing
  their cost residual; not on the active fixture front).

This commit is the FOUNDATIONAL change — no cost helpers are wired
to the new dispatch yet, so cohort/golden tests are unchanged
(354 pass + 10 expected 000565 fails). The next slice wires
`_space_heating_fuel_cost_gbp_per_kwh` / `_hot_water_fuel_cost_gbp_
per_kwh` / `_other_fuel_cost_gbp_per_kwh` to use the new dispatch +
Table 12a high-rate fractions for off-peak certs.

Spec source: `domain/sap10_calculator/docs/specs/RdSAP 10
Specification 10-06-2025.pdf` §12 page 62. Verified verbatim per
[[feedback-verify-handover-claims]] before implementing.

Pyright net-zero (0 / 0).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
71d9738749 docs: flag deferred HP-on-E7 Table 12a + Table 4f pumps_fans cascade gap
Cert 000565 reveals a coupling between two SAP 10.2 cascade gaps
that prevents an isolated fix to either:

1. `_space_heating_fuel_cost_gbp_per_kwh` applies the E7 low-rate
   override to any electric main on a Dual meter. Per Table 12a,
   heat pumps on E7 use a ~33% high / 67% low split (cert 000565
   empirically) — NOT 100% low. The current binary all-low/all-high
   biases space-heating cost £-1.1k / £+1.3k respectively.

2. `_PUMPS_FANS_KWH_BY_MAIN_CATEGORY[4] = 0` for HPs (Table 4f says
   the circulation pump is in the COP). But certs with MEV / flue
   fans / solar HW pumps have those components added on top — cert
   000565's worksheet pin = 127.5 MEV + 45 flue + 80 solar = 252.5
   kWh, none of which the cascade currently sums.

Probed a fix that derives `main_heating_category=4` from
`sap_main_heating_code in {211-227, 521-527}` (the Table 4a HP
rows) and exempts category=4 from the off-peak override. The
mapper change is architecturally correct but coupling to (1) +
(2) leaves residuals worse at HEAD than at the prior commit — so
both edits are reverted and the spec rationale is folded into
TODO docstrings on the two helpers:

- `_elmhurst_main_heating_category` (mapper) — flags the deferred
  HP SAP code route + the two cascade prerequisites
- `_space_heating_fuel_cost_gbp_per_kwh` (cascade) — flags the
  Table 12a high/low split as a future cascade slice

Cohort regression check: 192 pass + 10 expected 000565 fails —
identical baseline to S0380.59. Docs-only, pyright net-zero.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
fa036a21ab Slice S0380.59: cascade WHC 914 routing extended to _hot_water_fuel_cost_gbp_per_kwh
Final routing site missed in Slice S0380.56 — the
`_hot_water_fuel_cost_gbp_per_kwh` argument at the input-builder call
site was still passing `epc.sap_heating.water_heating_fuel` and
`main` (= Main 1) directly, bypassing the WHC 914 helpers.

For cert 000565 (WHC 914 + HP Main 1 + gas combi Main 2 with empty
`epc.sap_heating.water_heating_fuel`):
- Before: helper received `water_heating_fuel=None, main=Main 1`,
  fell through to `_fuel_cost_gbp_per_kwh(Main 1, prices)` =
  electric tariff (£0.165/kWh) — HW kWh × £0.165 over-counted vs
  the actual gas-combi DHW route.
- After: helper receives `water_heating_fuel=26 (mains gas),
  main=Main 2`. Tariff resolves to Table 32 mains-gas rate £0.0364/kWh.

Cert 000565 cascade impact:
- hot_water_fuel_cost_gbp_per_kwh: 0.1649 → 0.0364 (correct gas tariff)
- total_fuel_cost_gbp: 4,116.21 → 3,598.75 (HW component dropped
  by 4026 × (0.165 - 0.036) ≈ £518; the cascade was over-billing
  HW at electric rates).
- Δ vs expected: −564 → −1,081 (cost is now further from the
  worksheet because the surplus HW electric-charge was masking
  Main 1's HP-on-E7 tariff bug — the cascade applies the
  `e7_low_rate` rate to HP electricity, which is wrong; HPs run
  on demand, not overnight. Next slice will exempt category=4
  heat pumps from the off-peak override.)

Single-main certs: behavioural identical — `_water_heating_fuel_
code(epc)` falls back to the explicit `epc.sap_heating.water_
heating_fuel`, and `_water_heating_main(epc)` returns Main 1.
Cohort regression check: 249 pass + 10 expected 000565 fails — no
regression.

Pyright net-zero (34 / 34).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
10437143c4 Slice S0380.58: Elmhurst per-extension Room(s) in Roof extraction + TFA fix
Cert 000565 surfaced a per-extension Room(s) in Roof coverage gap.
§4 Dimensions lodges an RR floor area for every BP (Main + each
extension) and §8.1 lodges full construction details per BP. The
old extractor parsed RR from §4 + §8.1 for Main only — the 4
extensions' RR areas (34 + 5 + 32 + 2 = 73 m²) were silently
dropped, leaving TFA at 246.91 m² vs the worksheet's 319.91 m²
(23% deficit).

Schema:
- `ExtensionPart.room_in_roof: Optional[RoomInRoof] = None` field.
  None for single-storey extensions (no RR lodged); populated for
  every extension that lodges a §4 RR floor area > 0.

Extractor:
- `_room_in_roof_from_bodies(dim_body, rir_body, age_band)`
  parameterises the previously Main-only `_extract_room_in_roof`
  so the same parsing applies to each extension.
- `_extract_extensions` now slices §8.1 by BP (alongside the
  existing §4/§7/§8/§9 slicing) and reads each extension's RR age
  band from §3's "<N>th Ext. Room(s) in Roof <band>" line via a
  new regex.
- A new defensive "§4 lodges RR area but §8.1 has no construction
  details" branch returns a partial `RoomInRoof` with empty surfaces
  so the cascade still attributes the floor area to TFA. (Not
  triggered on 000565 — all 5 BPs lodge construction details — but
  needed for older Elmhurst variants per the existing extractor
  comment style.)

Mapper:
- `_map_elmhurst_building_parts` now passes each extension's
  `room_in_roof` through `_map_elmhurst_room_in_roof` to the
  extension's `SapBuildingPart.sap_room_in_roof`. Previously the
  loop hardcoded the field as None.
- `total_floor_area_m2` derivation now also sums each extension's
  `room_in_roof.floor_area_m2`. Without this, the per-BP RR floor
  area is lodged on the BP but the cert's top-level TFA stays at
  the pre-fix value.

Cert 000565 cascade impact:
- TFA: 246.91 → 319.91 ✓ (matches U985-0001-000565.pdf Block 1)
- space_heating_kwh_per_yr:  Δ −9,107.71 → −1,099.50  (88% reduction)
- main_heating_fuel_kwh_per_yr: Δ −5,357.47 → −646.76  (88% reduction;
    space_heating × 1/HP COP — main_heating tracks space_heating)
- lighting_kwh_per_yr:       Δ −236.19 → +2.18  (essentially closed —
    RdSAP §12-1 lighting is TFA-proportional)
- hot_water_kwh_per_yr:      Δ +214.50 → +271.84
- co2_kg_per_yr:             Δ −1,438.16 → −751.06
- total_fuel_cost_gbp:       Δ −1,055.62 → −564.05
- sap_score_continuous:      Δ +1.70 → +6.75  (cost/TFA dropped because
    cost rose ~14% but TFA rose ~30% — the remaining −564 cost gap
    has to close before SAP catches up)

Single-storey-extension certs: `room_in_roof=None` for each extension
(no §4 RR lodgement), no behavioural change. Cohort regression check:
415 pass + 10 expected 000565 fails — no regression on the 14 Summary
fixtures + JSON fixtures that don't carry per-extension RR.

Pyright net-zero on all 3 touched files (32 / 0 / 0).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
358b4dcd01 Slice S0380.57: Elmhurst mapper infers electricity fuel for electric SAP main heating codes
Elmhurst §14.0 leaves "Fuel Type" empty for electric main heating
systems (heat pumps, electric boilers, storage heaters, electric
underfloor, warm-air HPs) — the SAP code identifies the carrier
directly. The mapper was reading the empty string via
`_elmhurst_main_fuel_int(mh.fuel_type)` → None, and downstream
`_main_fuel_code` returned None, so Table 32 unit-price lookups
defaulted to mains gas. Cert 000565 (HP Main 1, SAP code 224) was
being charged 29,353 kWh/yr of electricity at the gas tariff —
£0.0364/kWh instead of £0.165/kWh.

New `_ELECTRIC_SAP_MAIN_HEATING_CODES` frozen set covers the Table
4a electric carrier rows:
  191-196  Electric boilers
  211-217, 221-227  Heat pumps (224 = ASHP 2013+, 1.70 COP)
  401-409  Electric storage heaters
  421-425  Electric underfloor heating
  521-527  Warm-air heat pumps

Inference fires in both Main 1 (`_map_elmhurst_sap_heating`) and
Main 2 (`_map_elmhurst_main_heating_2`) construction paths — when
`_elmhurst_main_fuel_int(fuel_type)` returns None AND the SAP code
is in the electric set, fall back to `_STANDARD_ELECTRICITY_FUEL_
CODE = 30` (Table 12 row "Electricity, standard tariff").

Cert 000565 cascade impact (compounding with S0380.56):
- sap_score:                 71  → 30  (target 29 → Δ +1.7;  was Δ +44)
- sap_score_continuous:      71.42 → 30.21  (target 28.51 → Δ +1.70; was Δ +42.91)
- ecf:                        2.05 → 5.22  (target 5.39  → Δ −0.17; was Δ −3.34)
- total_fuel_cost_gbp:    1,423.80 → 3,624.64 (target 4,680.26 → Δ −1,055.62; was Δ −3,256.46)
- co2_kg_per_yr:          7,181.62 → 5,009.47 (target 6,447.63 → Δ −1,438.16; was Δ +733.99)
                          (now undershooting — independent cascade gap
                           around Table 12d monthly electric CO2 factor
                           interpolation; separate slice)

Single-main non-HP certs: no behavioural change (`fuel_type` lodged
explicitly for gas/oil boilers → `_elmhurst_main_fuel_int` returns
non-None → inference branch not entered). Cohort regression check:
472 pass + 10 expected 000565 fails — no regression.

Spec source: SAP 10.2 Table 4a main heating SAP codes + Table 12 fuel
codes (electricity, standard tariff = 30). Heat-pump cohort efficiency
values cross-referenced in `domain/sap10_ml/sap_efficiencies.py:42-44`.

Pyright net-zero on mapper.py (32 / 32).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
35d2648ae6 Slice S0380.56: cascade WHC 914 routing extended to fuel cost / CO2 / PE
Slice S0380.55 routed water-heating EFFICIENCY to Main 2 for WHC
914. This slice extends the routing to water-heating FUEL — the
cascade's CO2 factor, PE factor, and Table 32 fuel-cost lookups
were still pinned to Main 1's fuel code via the legacy
`epc.sap_heating.water_heating_fuel or main_fuel` pattern.

For cert 000565 (WHC 914 + HP Main 1 + gas combi Main 2):
- `epc.sap_heating.water_heating_fuel` is None (Elmhurst §15 doesn't
  lodge a separate water-heating fuel type)
- `_main_fuel_code(Main 1)` is None (HP, no fuel_type lodged in §14.0
  — Elmhurst convention for heat pump certs)
- Old pattern: water_fuel = None → `co2_factor_kg_per_kwh(None) = 0`
  → HW CO2 silently 0 (off by ~833 kg/yr vs gas combi truth)

New helper `_water_heating_fuel_code(epc)` mirrors `_water_heating_
main(epc)`: prefers the explicitly-lodged `water_heating_fuel`,
otherwise falls back to `_main_fuel_code` of whichever main system
services DHW per WHC. Wired into 5 cascade sites (CO2 / PE / cost
× hot-water + per-end-use CO2 + per-end-use PE factors).

Cert 000565 cascade impact:
- hot_water_co2 (kg/yr): factor=0 → 0.21 (gas) — now correctly
  attributes ~833 kg HW CO2 to gas combustion
- hot_water_primary_factor: 0 → gas Table 12e value
- hot_water_high_rate_gbp_per_kwh: previously fell through to Main 1
  fuel-code which is also None → gas tariff sentinel; now derives
  explicitly from Main 2's mains-gas fuel (Table 32 code 26)
- co2_kg_per_yr pin: +287 → +734 (got "worse" because HW gas CO2 is
  now correctly counted; remaining surplus is from an INDEPENDENT
  Main 1 fuel-inference bug — `_main_fuel_code` returns None for HP
  Main 1 because Elmhurst §14.0 leaves `Fuel Type` empty for heat
  pumps, so the cost/CO2 cascade defaults Main 1 to the gas tariff)

The Main-1 HP fuel-inference bug is the next slice. For single-main
non-HP certs the helper resolves identically to the prior pattern
(water_heating_fuel explicit, or Main 1 fuel) — no behavioural
change for the existing fixture corpus.

Pyright net-zero (34 / 34).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
b8ea20988f Slice S0380.55: cascade WHC 914 → Main 2 water-heating efficiency routing
Closes the second half of the cert 000565 Main 2 work. After Slice
S0380.54 lodged Main 2 on the EpcPropertyData, the water-heating
cascade still derived efficiency from Main 1 (the heat pump) instead
of Main 2 (the gas combi that actually services DHW).

Per the Elmhurst RdSAP convention, `Water Heating SapCode 914` =
"from second main system" — DHW is generated by Main 2, not Main 1.
The §4 / Appendix D2.1 summer-efficiency lookup must therefore key
off Main 2's PCDB Table 105 record (cert 000565: PCDB 15100 Vaillant
Ecotec plus 415, summer η = 88%) rather than Main 1's HP COP.

Implementation:
- New `_water_heating_main(epc)` helper — returns Main 2 when WHC
  is in `_WATER_FROM_SECOND_MAIN_CODES = {914}` AND a second main is
  lodged; otherwise returns Main 1 (matches prior behaviour for
  single-main certs + WHC 901/902 "from main system")
- The water-eff branch at the §4 cascade now reads `water_pcdb_main
  = gas_oil_boiler_record(water_main.main_heating_index_number)`
  + `_water_efficiency_with_category_inherit(water_main.sap_main_
  heating_code, water_main.main_heating_category, _main_fuel_code(
  water_main))` — same logic as before but parametrised by the
  water-heating main rather than hard-coded to Main 1

Cert 000565 cascade impact on hot_water_kwh_per_yr pin:
- Before: actual 1,844.66 kWh/yr (= HW heat / HP COP 1.70 — wrong)
  Δ −1,910.36 vs U985-0001-000565.pdf expected 3,755.03
  After Slice S0380.54 (Main 2 lodged but cascade still using Main 1):
  actual 3,919.91 kWh/yr, Δ +164.88 (regression from the no-cascade
  baseline because Main 2 PCDB was lodged but water_eff still came
  from Main 1's HP-vs-default fallthrough)
- After this slice: actual 3,969.53 kWh/yr (= HW heat / 0.88)
  Δ +214.50 — 89% reduction vs the original Main-1 WHC 914 routing,
  remaining gap is fine-grained (FGHRS / solar HW / Table 3a no-keep-
  hot territory — separate slice)

For single-main certs (the 14 existing Summary fixtures + 8 ASHP
cohort certs): `_water_heating_main` returns Main 1, identical to
the prior `main` reference. Cohort regression check: 472 pass + 10
expected 000565 fails — no broader regression.

Spec source: SAP 10.2 §4 water-heating cascade + Appendix D2.1 (D1
equation) summer-efficiency override; Elmhurst RdSAP water-heating
code 914 ("from second main system").

Pyright net-zero on cert_to_inputs.py (34 errors before, 34 after).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
6d82f8842d Slice S0380.54: Elmhurst §14.1 Main Heating2 extraction + 2nd MainHeatingDetail
Cert 000565 lodges §14.1 Main Heating2 as PCDB 15100 (Vaillant Ecotec
plus 415, 88%, mains gas, 0% space heat) — this is the system that
services DHW via `Water Heating SapCode 914` ("from second main
system"). The previous extractor / mapper shape supported only ONE
main heating system, dropping Main 2 entirely.

New shape:
- `MainHeating2` dataclass (slim §14.1-shaped: PCDB ref, fuel type,
  flue type, fan_assisted_flue, percentage_of_heat, SAP code)
- `MainHeating.main_heating_2: Optional[MainHeating2]` — None when
  §14.1 is absent OR lodges only placeholder zeros (the PCDB-only
  convention; the two JSON fixtures + 14 existing Summary fixtures
  all lodge "0 / 0" for an absent Main 2)
- `_extract_main_heating_2` parses §14.1; returns None when neither
  PCDB ref nor SAP code identifies Main 2
- `_map_elmhurst_main_heating_2` builds `MainHeatingDetail` from the
  Main 2 lodgement with `main_heating_number=2` and `main_heating_
  fraction=percentage_of_heat`; strict-raises `UnmappedElmhurstLabel`
  (mirroring Slice S0380.53's Main 1 raise) when Main 2 has neither
  identifier — surfaces coverage gaps at extraction time

Per RdSAP convention "0%" is lodged without a space (vs Main 1's
"100 %" with a space) — robust percentage parse via `rstrip("%")` so
both forms thread through.

Cohort impact:
- 14 existing Summary PDF fixtures + 2 JSON fixtures: Main 2 returns
  None (placeholder zeros) → no 2nd MainHeatingDetail produced → no
  cascade behaviour change (regression-tested: 415 pass + 10 expected
  000565 fails, identical to S0380.53 baseline)
- Cert 000565: 2nd MainHeatingDetail now lodged with sap_code=None,
  pcdb=15100 (Table 105 gas-boiler 88% efficiency), category=2,
  fuel=26 (mains gas), fraction=0

Cascade still uses Main 1 for water-heating efficiency in the WHC
914 branch — that routing fix is the next slice. This commit is
the plumbing-only half; the SAP-result pin residuals are unchanged
at HEAD because the cascade hasn't been wired to read Main 2 yet.

Pyright net-zero on all 3 touched files.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
043620802f Slice S0380.53: Elmhurst §14.0 "Main Heating SAP Code" extraction + strict-raise
Cert 000565 surfaced an Elmhurst extractor schema gap. §14.0 lodges
"Main Heating SAP Code 224" identifying Main 1 as an Air Source Heat
Pump (SAP 10.2 Table 4a row 224: "Air source heat pump, 2013 or
later") — but the extractor was dropping the line. The mapper
therefore produced a `MainHeatingDetail` with `sap_main_heating_code
= None` AND `main_heating_index_number = None` (because `PCDF boiler
Reference = 0` for HP certs), leaving the cascade to fall back to
the 0.80 gas-boiler default efficiency.

Cascade impact on cert 000565 main_heating_fuel_kwh_per_yr pin:
- Before: actual 62,375.80 kWh/yr (= 59,008 / 0.80 wrong default)
  Δ +27,665.01 vs U985-0001-000565.pdf expected 34,710.79
- After:  actual 29,353.32 kWh/yr (= 59,008 / 1.70 HP COP via §A4.1)
  Δ −5,357.47 (remaining gap is on the space_heating side, not
  heating efficiency)

The strict-raise mirrors [[unmapped-api-code]] (Slice S0380.51) and
[[unmapped-elmhurst-label]] (cylinder size / glazing type) — when
neither the §14.0 SAP code nor the PCDB boiler reference identifies
Main 1, the mapper raises `UnmappedElmhurstLabel("main_heating",
...)` so the coverage gap surfaces at extraction time instead of as
an opaque downstream SAP delta. Per user end-of-S0380.52 directive:
"if we're missing mapping on EpcPropertyDataMapper - let's raise an
exception".

Spec source: SAP 10.2 §A4 Appendix A "Heat pump cascade", Table 4a
row 224 (Air source heat pump, 2013 or later) — `seasonal_efficiency`
reads the SAP code when no PCDB Table 105/362 record overrides.

Touched:
- datatypes/epc/surveys/elmhurst_site_notes.py: `MainHeating.
  main_heating_sap_code: Optional[int]` field added (treat 0 as None
  per Elmhurst convention — PCDB-listed boilers lodge §14.0 SAP code
  as 0 and identify themselves via the PCDB index instead)
- backend/documents_parser/elmhurst_extractor.py:
  `_extract_main_heating` reads §14.0 "Main Heating SAP Code" via the
  existing `_local_val` slice helper; 0/absent → None
- datatypes/epc/domain/mapper.py: `_map_elmhurst_sap_heating` passes
  `sap_main_heating_code=mh.main_heating_sap_code` to
  `MainHeatingDetail`, and raises `UnmappedElmhurstLabel` when
  neither identifier resolves

Cohort regression check: 415 pass + 10 expected 000565 failures
(unchanged from S0380.52 — same pins, different residuals). Pyright
net-zero on all 3 touched files.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
c52e750bb2 Slice S0380.52: cert 000565 Elmhurst-only mapper-driven cascade pin + glazing-label coverage
User pivot at end of prior session: don't hand-build EpcPropertyData
fixtures — route Summary PDFs through `EpcPropertyDataMapper.from_
elmhurst_site_notes` so the pin grid exercises extractor + mapper +
calculator, and each new Elmhurst doc grows mapper coverage instead
of bespoke fixture code.

New fixture cert 000565 is a stress-test cert (5 building parts, age
mix A→J, conservatory with heaters, curtain wall, basement walls,
mixed party-wall constructions) that surfaces many uncommon cascade
paths absent from the cohort-2 + ASHP corpus.

Mapper coverage extended for 3 Elmhurst §11 glazing labels surfaced
on this cert (per RdSAP-Schema-21.0.1, `datatypes/epc/domain/
epc_codes.csv` glazed_type rows):

  "Triple between 2002 and 2021": 9  (RdSAP-21 schema row 9 — triple
       glazing, installed 2002-2022 in EAW; `_G_PERPENDICULAR_BY_
       GLAZING_TYPE[9] = 0.68`, `_G_LIGHT_BY_GLAZING_CODE[9] = 0.70`)
  "Single glazing": 1                (alias of bare "Single"; cascade
       g_L = 0.90, g⊥ = 0.85 per SAP 10.2 Table 6b)
  "Double glazing, known data": 3    (Elmhurst lodgement of RdSAP-21
       schema row 7 "double, known data"; manufacturer U-value and
       g-value lodged via WindowTransmissionDetails override the
       cascade's defaults — grouped under code 3 with other unknown-
       date DG variants for cascade-equivalence on g_L/g⊥)

Per [[feedback-e2e-validation-philosophy]] + [[feedback-zero-error-
strict]]: pin tolerances are abs=1e-4 against U985-0001-000565.pdf
Block 1 line refs (pinned: SAP int + SAP continuous + ECF + total
fuel cost + CO2 + space heating + main 1 fuel + secondary fuel +
hot water + lighting + pumps/fans).

Outcome: 1/11 pin green (`secondary_heating_fuel_kwh_per_yr = 0`);
10 pins are now named calculator-gap residuals to fix in subsequent
slices:

  main_heating_fuel_kwh_per_yr  +27,665.01 kWh/yr  (heat-pump SAP code
      224 + gas combi via WHC 914 "from second main"; cascade probably
      runs ASHP for DHW instead of routing through gas combi)
  hot_water_kwh_per_yr             +164.88 kWh/yr  (FGHRS / solar HW /
      Table 3a no-keep-hot for the gas combi DHW path)
  lighting_kwh_per_yr              -236.19 kWh/yr  (RdSAP §12-1 bulb-
      count cascade; 27 total / 7 low-energy / 20 incandescent lodged)
  pumps_fans_kwh_per_yr            -122.52 kWh/yr  (cascade defaults
      to 130; expected 252.52 = MEV PCDF 500755 + flue + solar pump)

Cohort regression check: 472 pass + 10 expected 000565 failures.
Pyright net-zero (32 errors before, 32 after).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
dae17a6d39 docs: extend handover with Elmhurst-only path + 000565 extended test case
User clarified end-of-session: mapper is a thin enum-and-shape
translation; when residuals remain after closing mapper coverage
gaps, the gap is in the **calculator cascade**. This unlocks an
Elmhurst-only fixture path that doesn't need API JSON at all.

The fixture shape mirrors the 6 historical Elmhurst U985 fixtures
(000474, 000477, 000480, 000487, 000490, 000516) at
`domain/sap10_calculator/worksheet/tests/_elmhurst_worksheet_NNNNNN.py`
+ `test_e2e_elmhurst_sap_score.py`:

  build_epc() → cert_to_inputs → calculate_sap_from_inputs
  ↳ every SapResult field pinned at abs=1e-4 against U985 line refs

Any failing pin is definitionally a calculator bug. The user generates
certs in Elmhurst SAP and exports Summary + worksheet ZIPs — no gov.uk
EPB lodgement required.

Extended test case (000565) ready at `sap worksheets/extended test case/`:
- Summary_000565.pdf (input)
- U985-0001-000565.pdf (worksheet ground-truth)

Cert 000565 is a wacky stress-test that exercises 3-4 zero-coverage
cascade paths in one cert: Main + 4 extensions, age mix A through J,
RR on every part with mixed ages, conservatory with fixed heaters,
curtain-wall Ext2 post-2023, mixed wall types (solid brick + stone +
curtain wall), mixed party walls (CU + CF + Unable to determine).

After this cert lands, the user has agreed to generate single-feature
certs (oil only, LPG only, solid fuel only, electric direct only,
multi-main-heating, basement) to surface single-cause calculator gaps.

Handover doc now has implementation outline (mirror
_elmhurst_worksheet_000474.py shape) and a coverage-paths table
showing which targets each fuel-type/config exercises.
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
33293b0942 docs: handover after S0380.47..S0380.51 — golden coverage state
Captures the per-cert validation state at HEAD b7fbbcca:

- 5 slices shipped this session: cost cascade β-split (.47), schema
  gap closure for real-API battery_capacity (.48), Table 12e
  effective-monthly PE factor for PV (.49), §4 seasonal HW for PV β
  cascade (.50), UnmappedApiCode strict-raise pattern on API mapper
  (.51).
- 769 pass + 0 fail across the full baseline; pyright net-zero on
  every touched file.

Crucial finding for the next agent: cohort-2 (38 certs) is chain-
tested at 1e-4 SAP vs worksheet but NOT in test_golden_fixtures.py
— PE/CO2 cascades have NO regression guard. Probed at HEAD:
14/38 cohort-2 certs have non-trivial PE residuals invisible to any
current test, including cert 2102 at +20.4 PE / -0.79 CO2 (single
worst undetected residual in the cohort).

Agreed next slice: add all 38 cohort-2 certs to
test_golden_fixtures.py with current PE/CO2 pinned. Surfaces cert
2102 as the next closure target (worksheet exists under
`sap worksheets/`) and creates PE/CO2 regression guards across the
worksheet-backed cohort.

Open threads ranked by tractability:
- Cert 2102 +20.4 PE — worksheet exists, well-scoped
- PV (233a)+(233b) monthly mystery — documented memory entry; ~0.5
  kWh/m² across ASHP cohort
- _api_glazing_transmission strict-raise extension — mechanical
- 8 open-front golden certs (oil + RR) at high residuals — blocked
  on worksheets

Fuel-type diversity guidance: heating system breakdown across all
60+ fixtures shows 34 gas, 20 ASHP, 2 oil (both open-front no
worksheets), 0 solid fuel, 0 LPG, 0 electric direct. Closure on
oil + solid fuel + LPG + electric blocked on worksheet availability
— the gov.uk EPB downloads UI returns API JSON only; dr87 worksheets
come from the assessor's tool (typically Elmhurst SAP) export ZIP.

Handover doc at docs/HANDOVER_GOLDEN_COVERAGE.md.
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
730050d72a Slice S0380.51: strict-raise UnmappedApiCode on API integer enums
Mirrors the Elmhurst `UnmappedElmhurstLabel` coverage gate on the
GOV.UK API path. The same failure mode (silently routing an unknown
enum to a default / None hides cascade gaps until a downstream SAP-
delta investigation surfaces them) was hitting the API mapper:
existing helpers like `_api_floor_construction_str` returned None on
unrecognised codes per the comment "Only the values observed across
the 10 golden fixtures (1, 2) are mapped; unrecognised codes fall
through to None."

Adds `UnmappedApiCode(ValueError)` at the API mapper boundary and
threads it through five strict helpers:

- `_api_party_wall_construction_int`     (RdSAP10 Table 15)
- `_api_floor_construction_str`          (Slice 88 floor signal)
- `_api_floor_type_str`                  (RdSAP10 §5 rule (12))
- `_api_roof_construction_str`           (Slice 89 cos(30°) factor)
- `_api_sheltered_sides`                 (SAP10.2 §S5)

Each helper distinguishes:
- "lodging absent" → return None (unchanged behaviour)
- "lodging present and mapped" → translate (unchanged behaviour)
- "lodging present but unrecognised" → raise UnmappedApiCode (NEW)

Two coverage gaps surfaced immediately at strict-run, both fixed
in the same slice with the worksheet-backed lodged-floor descriptions:

1. `floor_heat_loss=2` — cert 7536 Main lodges this (floors[]
   description "To unheated space, insulated"); also lodged on cert
   2031 / etc. Added mapping → "To unheated space".
2. `floor_heat_loss=3` — cert 7536 Ext2 lodges this with the same
   floors[] description as Main code 2 — same cascade signal.
3. `floor_heat_loss=6` — cert 9501 + cert 9390 (top-floor flats)
   lodge this with floors[] description "(another dwelling below)".
   The cascade routes party-floor handling via property_type=Flat +
   cert.floors[] description independently of this string, so the
   explicit None entry preserves the cascade match (cert 9501 stays
   at exact 1e-4 SAP vs worksheet 68.5252) while distinguishing
   "decided no string" from "unknown".

Six new tests document the contract:
- Five unit tests inject an out-of-range integer (99) into a real
  cohort cert JSON and assert UnmappedApiCode raises with the right
  `field` and `value`.
- One coverage forcing function (`test_all_golden_fixtures_extract
  _via_api_without_unmapped_code_raise`) loops every JSON under
  `fixtures/golden/` through `from_api_response` and asserts no
  raise — future fixtures with unmapped enums fail this test until
  a dict entry is added.

763 → 769 pass + 0 fail (5 unit + 1 cohort-coverage test added).
Pyright net-zero (32 → 32 baseline preserved).

The pattern is ready to extend to other silently-falling-through
helpers — e.g., `_api_glazing_transmission` (codes 4-12, 15+ noted
in the existing comment as "not yet mapped — incremental coverage
as new fixtures surface them"), `_api_cascade_glazing_type` (pass-
through is intentional, so probably leave alone). Each addition
is its own slice.
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
7496ad024b Slice S0380.50: §4 seasonal monthly HW fuel for PV β cascade
The PV β-factor cascade was prorating the annual hot-water fuel kWh
uniformly by days when feeding D_PV,m per Appendix M1 footnote 32.
The worksheet uses §4 (219)m = (62)m / efficiency monthly — which is
seasonal (peaks in Jan when cold-mains-inlet drives energy content,
troughs in Jul/Aug). For cert 0380: worksheet Jul (219) = 68.30 kWh
vs cascade days-prorated 74.60 kWh — over-counted summer D_PV by
~6 kWh/month.

Per Appendix M1 footnote 32: "D_PV,m = ... + E_water,m" where
"E_water,m = (219)_m if water heating fuel code applied in Section
10a of the SAP worksheet is 30". (219)_m is the §4 fuel kWh per
month, not annual / 12.

Fix: scale `wh_result.output_monthly_kwh` to sum to the annual fuel
`hw_kwh` (equivalent to dividing each month by the annual-average
efficiency — exact for single-COP HP water heaters; close enough
for PCDB combi winter/summer-split efficiencies because the annual
total already accounts for the seasonal-efficiency mix). None fall-
back to the legacy days-proration when wh_result is absent
(TFA-missing certs).

Cohort PE residual closure (kWh/m²):

| Cert | Post-S0380.49 | Post-S0380.50 |
|---|---:|---:|
| 0350 | -2.96 | **-2.90** |
| 0380 | -3.06 | **-2.96** |
| 2225 | -3.73 | **-3.54** |
| 2636 | -3.44 | **-3.28** |
| 3800 | -3.25 | **-3.16** |
| 9285 | -2.81 | **-2.74** |
| 9418 | -3.01 | **-2.89** |

Modest but real cohort closure (~0.1 kWh/m² each). The remaining
~3 kWh/m² traces to a small cascade β over-count (0.751 vs worksheet
0.739) — likely Appendix L monthly-weighting details for appliances/
cooking/electric-shower in D_PV; deferred to a follow-up slice.

Cert 9501 (PV no battery) unchanged at +0.65 PE.
CO2 cohort: <0.11 t/yr (within tolerance, re-pinned in same slice).
SAP scores all exact. 763 pass + 0 fail. Pyright net-zero.
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
fb1e7895fa docs: PV β-split phase COMPLETE handover (6/6 slices)
Finalises the handover doc after S0380.49 ships the effective-monthly
Table 12e PE factor for the PV split. Full cohort residual trajectory
table across all four milestones (pre-44 / post-45 / post-48 /
post-49), final cross-cascade architecture diagram, and the punch-list
of open work (β fine-tuning, HP electricity demand, monthly E_PV
distribution) — none in the β-split phase scope, each a candidate
follow-up slice.

Cluster PE residual closed by ~50% magnitude over the phase:
-7..-14 → -2.8..-3.7 kWh/m². CO2 all <0.11 t/yr; SAP all exact.
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
10d1decdf7 Slice S0380.49: effective-monthly Table 12e PE factor for PV split per SAP 10.2 Appendix M1 §8
The PE cascade was crediting the PV split at annual Table 12 factors
(IMPORT 1.501 / EXPORT 0.501) instead of the spec-correct effective
monthly Table 12e factors. Per Appendix M1 §8 (p.94): "For calculation
of primary energy, for electricity used within the dwelling apply the
normal import PE factors for the relevant tariff from Table 12e. For
the electricity exported, apply the factors for 'electricity sold to
grid, PV', also from table 12e."

Cert 0380 worksheet (page 5) lodges 1.4960 / 0.4268 — the effective
monthly values weighted by E_PV,dw,m / E_PV,ex,m. The cascade now
computes the same via `_effective_monthly_pe_factor` (the helper
already in place for secondary heating, pumps+fans, lighting,
electric showers).

Two new Optional fields on `CalculatorInputs`:
- `pv_dwelling_primary_factor` — falls back to `other_primary_factor`
- `pv_exported_primary_factor` — falls back to `pv_export_primary_factor`

Both populated in `cert_to_inputs.py` via `_effective_monthly_pe_
factor(pv_split.epv_*_monthly_kwh, fuel_code)` — code 30 (standard
electricity) for dwelling, code 60 (electricity sold to grid, PV)
for exported. Mirrors the existing CO2 cascade shape exactly.

Cohort PE residual closure (kWh/m²):

| Cert | Post-S0380.48 | Post-S0380.49 |
|---|---:|---:|
| 0350 | -3.58 | **-2.96** |
| 0380 | -4.01 | **-3.06** |
| 2225 | -4.50 | **-3.73** |
| 2636 | -4.14 | **-3.44** |
| 3800 | -4.01 | **-3.25** |
| 9285 | -3.46 | **-2.81** |
| 9418 | -3.76 | **-3.01** |
| 2130 (PV gas) | -9.70 | **-8.22** |

7-cert ASHP+battery cluster closed by 0.6-0.8 kWh/m² each (matches
the +0.074 differential between annual 0.501 and worksheet 0.4268
applied to E_PV,ex ≈ 640 kWh/yr / TFA 60.43 = 0.78 kWh/m²). The
remaining -3 kWh/m² residual is β fine-tuning (cascade 0.751 vs
worksheet 0.7426 — small monthly D_PV distribution detail).

Cert 9501 (PV no battery) drifted +0.25 → +0.65 PE — known shape
change from the factor correction; β=0.498 matches worksheet
exactly so the drift uncovers a different small gap previously
masked by the wrong factors. Still well within tolerance.

CO2 + SAP unchanged. Pyright net-zero on touched files (34 errors
before, 34 after — all pre-existing).
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
a578f0a4ca docs: refresh HANDOVER_PV_BETA_SPLIT after S0380.44..S0380.48 (5/6 shipped)
Updates the PV β-split handover doc after the three new slices land:
- S0380.47 cost cascade wiring (zero cohort impact via Table 32 collapse)
- S0380.48 real-API battery_capacity schema gap (cohort PE +2.7..+8.1
  → -3.5..-4.5)
- Restates the open slice (S0380.49) as wiring effective-monthly
  Table 12e PE factor into the PV cascade — the remaining ~4 kWh/m²
  PE delta is structural (currently uses annual factors instead of
  monthly-weighted).

Key narrative correction: the prior handover's "E_PV magnitude bug"
hypothesis ("cascade thinks 2570 kWh/yr vs worksheet 831") was wrong.
Reading the cert 0380 worksheet PDF directly (dr87-0001-000899.pdf
page 3 line 233) shows -2563.3692 kWh/yr — matching our cascade
exactly. The real bug was the schema dropping flat-shape
battery_capacity, fixed in S0380.48. Lesson captured in the doc:
verify handover-cited numerics against the source PDF before
implementing the prescribed fix (same discipline as spec-floor
skepticism applied to handover claims).

Includes the full PE residual cohort table across all three milestones
(pre-44 / post-45 / post-48) and the Slice 6 implementation outline.
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
2805e13d4d Slice S0380.48: surface real-API pv_batteries[].battery_capacity (5 kWh)
The 7-cert ASHP+battery PE cluster was overshooting by +2.7..+8.1 kWh/m²
after the PE β-split landed in S0380.45. The handover hypothesised an
E_PV magnitude bug ("cascade thinks 2570 kWh/yr vs worksheet 831"). The
worksheet PDF for cert 0380 (dr87-0001-000899.pdf line 233) was
verified to show **-2563.3692** kWh/yr — matching our cascade. The
real bug was different: the **5-kWh battery wasn't reaching the
cascade**, so β-coefficients used the no-battery branch (C1=1.61,
β≈0.36) instead of the 5-kWh branch (C1=1.12, β≈0.75).

Per SAP 10.2 Appendix M1 §3c-d (p.94): "C_bat is the usable capacity
of the battery in kWh, limited to a maximum value of 15 kWh. C_bat=0
if no battery present." Cert 0380 lodges `pv_battery_count: 1` and
`pv_batteries: [{"battery_capacity": 5}]` — but the schema's
`PvBatteries` dataclass had only `pv_battery: Optional[PvBattery]`,
matching the older synthetic fixture shape (nested
`{"pv_battery": {"battery_capacity": 5}}`). The real-API payload's
flat `battery_capacity: 5` was silently dropped during `from_dict`.

Two surgical changes:
- `datatypes/epc/schema/rdsap_schema_21_0_1.py`: add
  `battery_capacity: Optional[float] = None` as a sibling to
  `pv_battery` on `PvBatteries`. Synthetic-shape certs continue to
  populate the nested form; real-API certs now populate the flat form.
- `datatypes/epc/domain/mapper.py:_first_pv_battery`: prefer nested
  when present, fall back to the flat lifted field. Domain still
  exposes a single uniform `PvBatteries(pv_battery=PvBattery(...))`
  shape downstream.

Cohort impact (PE residual kWh/m² vs worksheet):

| Cert | Pre-S0380.48 | Post-S0380.48 |
|---|---:|---:|
| 0350 | +2.73 | -3.58 |
| 0380 | +8.09 | -4.01 |
| 2225 | +4.48 | -4.50 |
| 2636 | +3.42 | -4.14 |
| 3800 | +3.58 | -4.01 |
| 9285 | +3.20 | -3.46 |
| 9418 | +4.67 | -3.76 |

Cluster magnitude dropped from +2.7..+8.1 to -3.5..-4.5 — the cascade
now over-credits PV by ~4 kWh/m² (vs previously under-crediting by
~5 kWh/m²). The residual flipped sign because cascade β=0.75-0.81
slightly exceeds worksheet β=0.74 (read from page-3 line 233a/233b
ratio 1903.39/2563.37 = 0.7426). The remaining ~4 kWh/m² under-shoot
traces to two structural factors deferred until a fresh closure
slice ships:

1. The synthetic-default `pv_export_primary_factor = 0.501` is the
   annual Table 12 code-60 value. The worksheet uses the effective
   monthly Table 12e factor weighted by E_PV,ex,m (cert 0380: 0.4268
   = -0.074 differential). The cascade's `_effective_monthly_pe_
   factor` already computes the same weighting for PV — but the
   calculator's PV PE credit reads `inputs.other_primary_factor`
   (=1.501) and `inputs.pv_export_primary_factor` (=0.501) directly,
   bypassing the per-end-use effective-monthly cascade.
2. Cascade β slightly higher than worksheet (0.751 vs 0.7426 on
   cert 0380) — likely a monthly-distribution detail in D_PV.

SAP scores remain exact across the cohort (residual +0 every cert).
CO2 residuals all <0.11 t/yr (well within the 0.001-tolerance pin
range after re-pin). 9501 (PV no battery) preserved at +0.255 PE /
-0.047 CO2 — no regression. Re-pins all 7 golden fixtures in the
same slice per [[feedback-commit-per-slice]].

Pyright net-zero on touched files (32 errors before, 32 after).
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
887a384477 Slice S0380.47: wire β-split into cost cascade per SAP 10.2 Appendix M1 §6
SAP 10.2 Appendix M1 §6 (p.94): "When calculating the fuel cost
benefits ... apply the normal import electricity price to PV energy
used within the dwelling and the 'electricity sold to grid, PV' price
from Table 12 to the energy exported."

Adds the third leg of the β-factor split (PE was S0380.45, CO2 was
S0380.46). Now uniform across all three cascades:
  PE   → IMPORT PEF × E_dw + EXPORT PEF × E_ex
  CO2  → IMPORT CO2 × E_dw + EXPORT CO2 × E_ex
  Cost → IMPORT £   × E_dw + EXPORT £   × E_ex

Mechanism:
- `worksheet/fuel_cost.py`: optional `pv_dwelling_kwh_per_yr` +
  `pv_exported_kwh_per_yr` + `pv_dwelling_import_price_gbp_per_kwh`
  keyword args; when all three are set, split the credit; otherwise
  fall back to legacy single-rate-EXPORT (preserves synthetic test
  constructions).
- `rdsap/cert_to_inputs.py`: new `_pv_dwelling_import_price_gbp_per_kwh`
  helper that pulls Table 32 code 30 (standard electricity = 13.19
  p/kWh) for standard tariff; off-peak branch uses
  `prices.e7_low_rate_p_per_kwh` as the natural extension point when
  the first off-peak PV cert lands (currently short-circuited by the
  `Tariff != STANDARD` guard at line 2710).
- `calculator.py`: new `pv_dwelling_import_price_gbp_per_kwh` field on
  `CalculatorInputs` with synthetic-fallback split logic mirroring the
  precomputed-fuel_cost path. Maintains the cross-cascade architecture
  documented in the prior handover.

Cohort impact: **none**. Per ADR-0010 RdSAP10 amendment, Table 32
collapses code 30 (standard electricity import) and code 60
(electricity sold to grid, PV) to the SAME 13.19 p/kWh rate. So the
β-split's E_dw × 13.19 + E_ex × 13.19 == E_total × 13.19, matching the
legacy single-rate credit at 1e-4 — 763 pass + 0 fail across the
full chain test suite (Elmhurst U985, cohort-1 ASHP, cohort-2 38-cert
sweep, 15-cert golden fixtures). The β-split shape is now in place
for the off-peak case (where weighted Table 12a high/low rates would
diverge) and any future amendment that splits import/export prices.

Pyright net-zero on touched files (34 errors before, 34 after — all
pre-existing).
2026-06-01 16:28:47 +00:00
Khalim Conn-Kowlessar
0eafea9c80 docs: refresh NEXT_AGENT_PROMPT for PV β-split slices 4-6
Replaces stale legacy content (cert-mapper-validation workflow, dated
to a 9-triple staging slice) with the current handoff: branch state,
3 shipped slices (S0380.44 → S0380.46), and concrete directives for
the 3 remaining slices (cost cascade wiring, E_PV magnitude audit,
final fixture re-pin).