Commit graph

2547 commits

Author SHA1 Message Date
Khalim Conn-Kowlessar
090e16ddc2 Dispatch PasHub mechanical ventilation into the §2 ACH cascade 🟩
The surveyed "Ventilation type" label never reached
mechanical_ventilation_kind, so ventilation_from_cert silently defaulted every
mechanical system to NATURAL (24d), dropping its ACH heat loss — 76/205
cohort fixtures lodge dMEV/MEV/PIV (issue #1590 bug 4). Mapping mirrors the
gov-API _API_MECHANICAL_VENTILATION_TO_KIND table (PIV-from-loft is
"as natural"). Harness: within-0.5 12.2% -> 18.5%, MAE 2.538 -> 1.730 — the
campaign's largest single move; floors ratcheted to 0.18 / 1.75.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:45:24 +00:00
Khalim Conn-Kowlessar
56b36ce7f0 Resolve the PasHub PV Connection label to the gov-API credit-gate int 🟩
"Not connected to electricity meter" -> 1 (zero Appendix M credit), "Connected
to dwellings electricity meter" -> 2; the raw string fell through the credit
gate's non-int branch to True, crediting a separately-metered array (issue
#1590 bug 3, fixture 499516101839 -6.9 SAP). Harness MAE 2.571 -> 2.538;
ceiling ratcheted to 2.55.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:41:04 +00:00
Khalim Conn-Kowlessar
f92d4f26b8 Extract the PasHub per-system PV block and diverter flag 🟩
"Photovoltaic array kWp Known? Yes" lodges a per-system block (kWp, pitch,
orientation, overshading) instead of the percent-roof estimate; the extractor
only read the estimate, so measured PV never reached the mapper and the
Appendix M credit was silently zero (issue #1590 bug 1). Harness MAE
2.632 -> 2.571 (fixture 507639151843's 13.5-SAP under-rate closes to +0.5);
ceiling ratcheted to 2.58.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:38:07 +00:00
Khalim Conn-Kowlessar
80de9b0c04 Extract the PasHub per-system PV block and diverter flag 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:35:34 +00:00
Khalim Conn-Kowlessar
bc58cf4930 Lodge explicit zero roof insulation for a surveyed "Insulation At: None" 🟩
"Insulation At: None" is the assessor recording zero loft insulation, not an
unknown — with thickness left None, u_roof fell through to the age-band
"assumed insulated" default (0.16 W/m²K at band J/K) instead of the Table 16
uninsulated row (2.30), understating roof loss ~14x (issue #1590 bug 2).
Harness MAE 2.701 -> 2.632 (the two ~7-SAP roof over-raters correct exactly);
ceiling ratcheted to 2.64.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:28:25 +00:00
Khalim Conn-Kowlessar
999008f9d0 Refresh pashub accuracy manifest pre_sap from the corrected DB rows
Two hubspot_deal_data corrections: 499539910905 D58->B82 (confirmed bad row)
and one C73->C75. Rebuilt via scripts/build_pashub_accuracy_fixtures.py
(no --force; PDFs unchanged).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:24:37 +00:00
Khalim Conn-Kowlessar
cab7e3d613 Close the last PasHub mapper gaps: secondary fuel + Group 3 heat-network control 🟩
Secondary fuel 'Mains gas'/'Mains Gas'->26 and 'House Coal'->11 (Table 32);
main-heating control resolution becomes group-aware with a Table 4e Group 3
map ('Charging system linked to use of community heating, room thermostat
only' -> 2306, the code the accredited Elmhurst certs lodge for this cohort;
all four linked-to-use codes are calculation-identical). All 205 Guinness
fixtures now compute (was 201/4 xfails); ratchet re-baselined to the
full-coverage aggregate (12.2% within-0.5 floor, MAE ceiling 2.71) with the
two newly-computable outliers documented for verification.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:24:36 +00:00
Daniel Roth
ecb113b52e Re-ratchet PasHub SAP-accuracy floor to the current integrated aggregate (12.4% within-0.5) 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:57:34 +00:00
Daniel Roth
df3fce0a3f
Merge branch 'main' into feature/pashub-map-main-heating-control-1557 2026-07-14 18:50:08 +01:00
Daniel Roth
98aa0127a7 Keep swallowing the control gap's boundary form in the accuracy harness 🟪
The control gap surfaces as UnmappedSapCode on main and as UnmappedPasHubLabel
once the #1557 control mapper lands (unmapped community-heating control), so the
harness must swallow both; only the closed fuel-specific MissingMainFuelType is
dropped as a fuel-drop tripwire.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:40:50 +00:00
Daniel Roth
88f221b86e Stop swallowing closed PAS Hub main-fuel gaps in the accuracy harness 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:24:15 +00:00
Daniel Roth
8529c71ff2 Capture PAS Hub main-heating fuel from the colon 'Fuel:' label variant 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:19:12 +00:00
Daniel Roth
2783c2c0c6 Capture PAS Hub main-heating fuel from the colon 'Fuel:' label variant 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:18:46 +00:00
Daniel Roth
aa69462b5b Raise PasHub SAP-accuracy floor to 13.4% within-0.5 on the merged fabric stack 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 16:55:03 +00:00
Daniel Roth
5da621c7a5 Ratchet PasHub SAP-accuracy floor to 10.9% within-0.5 (control-code fix unblocks 201/205) 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 16:43:54 +00:00
Khalim Conn-Kowlessar
e5fee3896a Add PAS Hub SAP-accuracy regression harness (Guinness 205 cohort)
Foundation for PRD #1555: runs each PAS Hub site-note PDF through the
extractor -> EpcPropertyData -> Sap10Calculator and gauges the computed
SAP against pashub's own SAP-10.2 `pre_sap` (from hubspot_deal_data).

- test_pashub_sap_accuracy.py: hybrid gate. Per-fixture "must compute"
  (xfail on the known in-progress mapper gaps MissingMainFuelType /
  UnmappedSapCode / UnmappedPasHubLabel) + aggregate within-0.5 ratchet
  floor, mirroring test_sap_accuracy_corpus.py.
- 205 image-stripped site-note PDFs + manifest.json. Images stripped so
  the repo footprint stays ~52MB while the text layer the extractor reads
  is byte-identical.
- build_pashub_accuracy_fixtures.py: provenance/rebuild from S3 +
  hubspot_deal_data.

All 206 currently xfail on the known heating-string mapper gaps; each fix
(#1556-1568) flips its fixtures to computing and ratchets the floor.

Refs #1555 #1568

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 15:32:18 +00:00
Daniel Roth
442352c378 Drop the unused DownloadedFile import from the client tests 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:07:23 +00:00
Daniel Roth
38cae15f4d Preserve SharePoint distribution when the site-note save fails loudly 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
e31d2ad2d1 Preserve SharePoint distribution when the site-note save fails loudly 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
62c0151469 Fill partial summaries best-effort, fail loudly, skip evidence-only jobs, and retry on Coordination Hub 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
377c030c77 Overlay PasHub as-surveyed performance onto saved Site-Notes property 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
43fac40595 Overlay PasHub as-surveyed performance onto saved Site-Notes property 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
ded8cf1e46 Raise loudly when RdSAP Summary fetch returns an HTTP error 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
eff4f64426 Raise loudly when RdSAP Summary fetch returns an HTTP error 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
83d92010de Raise UnauthorizedError when RdSAP Summary fetch returns 401 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
b596f32af1 Raise UnauthorizedError when RdSAP Summary fetch returns 401 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
af6c461c93 Map PasHub RdSAP Summary response to as-surveyed performance values 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
85482cdf9e Map PasHub RdSAP Summary response to as-surveyed performance values 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
b5c05166db Persist resolved UPRN on PasHub site-notes rows (#1537)
Thread the UPRN the PashubService has already resolved for a job into the
PasHub site-notes mapper so the EpcPropertyData aggregate is born with its
uprn set, and the existing save_epc_property_data path persists it.

- EpcPropertyDataMapper.from_site_notes gains uprn: Optional[int] = None and
  sets it unconditionally (site notes never carry a UPRN natively).
- parse_site_notes_pdf / _parse_pashub forward the uprn; the Elmhurst branch
  is untouched.
- PashubService coerces uprn str -> int in one place, carries it on the
  internal upload record, and passes it into parse_site_notes_pdf.
- No new lookups; jobs with no known UPRN still persist null, unchanged.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-10 13:19:28 +00:00
Jun-te Kim
e91e0fa33e Fix cylinder_size/boiler_flue_type input errors for UPRN 100010086084 (SAP-15.0)
Both flagged mismatches were Elmhurst input errors (same silent-stale-value
contamination class as the earlier chimneys/wall-thickness bugs), not
parser or calculator bugs:

- cylinder_size: build_100010086084.py's water_heating() selected
  DropDownListCylinderSize by raw value "2", but this DOM's option values
  ARE their visible litre-band text (no "2" among them) — Playwright
  silently no-ops on a non-matching value, leaving a prior cert's "Medium
  (131-170L)" selection in place. Fixed to match by text ("Normal"), and
  added the missing mapper dict entries (Normal/Large litre-suffixed
  labels) to _ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10 (a real mapper-coverage
  gap — the calculator raises UnmappedElmhurstLabel rather than silently
  mis-mapping).

- boiler_flue_type: the boiler-code search dialog's combined "Balanced/Open
  Flue" Table 4b category doesn't drive the separate, independently
  selectable RadioButtonListFlueType field, which was left at an inherited
  "Balanced" from a prior cert. Fixed space_heating() to explicitly select
  "Open" to match the lodged gov-API code. This field isn't consumed by
  Sap10Calculator (ML/generator-only), so it had zero effect on the SAP
  score.

Re-downloaded elmhurst_summary.pdf/elmhurst_worksheet.pdf after the fixes
(Recommendations page confirmed clean). Elmhurst-PDF-inputs path moved
46->47 SAP from the cylinder-volume correction; gov-API SAP (53) and
Elmhurst's own worksheet (51) are unchanged. Full accuracy suites re-run
clean (67 passed, 67 skipped, 1 xfailed, same as before).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-10 09:11:41 +00:00
Jun-te Kim
798d19d6ff Fix contaminated Elmhurst ground truth for UPRN 100010086084 (SAP-15.0)
The Elmhurst rebuild for this cert had two carryover bugs from the shared
Playwright session: TextBoxOpenChimneys silently inherited "2" from a prior
cert's build (this cert's register lodges open_fireplaces_count=0, which
the gov-API mapper already reads correctly), and wall thickness inherited
a stale 280mm. Also fixed a real bug in the space_heating() PCDB-ref-clearing
logic: input_value() returns the string "0" when already cleared, which is
truthy in Python, causing a spurious navigate-away that broke the next
E.goto() call.

Rebuilt cleanly (chimneys=0, wall thickness=220mm per RdSAP convention for
unrecorded solid-wall thickness, since CheckBoxWallThicknessUnknown does not
persist via Playwright in this tool version). Elmhurst's own worksheet score
moves from a contaminated 46/48 to 51, closing the gap against this engine's
53-on-gov-API-inputs from ~5-7pt to ~2pt. No mapper.py change was needed --
the gov-API mapper's open_chimneys_count=0 was correct all along.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-10 08:36:03 +00:00
Jun-te Kim
283b311fcd Real Elmhurst RdSAP10 ground truth for one SAP-Schema-15.0 cert
Built UPRN 100010086084 (the largest gov-API-vs-lodged outlier from the
20-cert batch) in Elmhurst's accredited RdSAP10 tool to get real ground
truth, per feedback that lodged rating isn't a valid comparison target.

Elmhurst worksheet: SAP 46-48 (orientation-dependent), vs this engine's
53 on gov-API inputs -- a real ~5-7pt residual gap. Ruled out with
direct empirical tests: total_floor_area, missing party_wall_length,
region/climate (SAP rating always uses UK-average weather per Appendix
U -- confirmed inert), boiler/secondary efficiency (exact match, 66%/
63% both sides). Confirmed real but NOT blind-fixed (need more than one
cert's evidence, and a wall-U-value patch tested the wrong direction in
isolation): a wall-thickness-unknown U-value fallback mismatch (this
engine 1.70, Elmhurst's own "unknown" resolution 1.40) and a window
U-value divergence (1.85 vs 2.52 W/m2K for the same nominal glazing
pick). Single-window orientation confirmed a ~2pt partial contributor.

Also fixes a small, separate, evidenced gap the build surfaced: the
Elmhurst summary parser didn't recognise the live tool's "Medium
(131-170L)" cylinder-size label (only the bare "Medium").

Full write-up is in the RealCertExpectation comment for this cert in
test_real_cert_sap_accuracy.py and the worklist. Residual gap is
intentionally left open for follow-up, not force-closed.
2026-07-09 22:31:01 +00:00
Jun-te Kim
ce5899c5ec Validate SAP-Schema-15.0 mapper against 20 real certs from the failing task
Sampled all 20 unique property_ids that failed with "Unsupported EPC
schema: 'SAP-Schema-15.0'" across the sub_task history (114 total across
72 subtask rows), captured 20 real live certs, and pinned each as a
RealCertExpectation regression in the accuracy corpus.

16/20 land exact or within 1-3 SAP of the lodged rating, confirming the
door_count/WWHRS/FGHRS/draught-proofing defaults generalise beyond the
original two properties. The other 4 (all solid-brick, uninsulated,
age band C) diverge +6 to +12 — traced to a legitimate SAP-2009-vintage-
lodgement vs RdSAP10-recalculation methodology gap (u_wall() checked
directly against RdSAP10's own Table 6, returns the correct 1.70 — no
mapper defect), not a mapper bug, so pinned to the engine's observed
value rather than tuned to lodged.
2026-07-09 19:06:21 +00:00
Jun-te Kim
04d1df1343 Add remaining planning/address-profiling fields to HubSpot ETL sync
Sync Design Constraints, Planning Comments, Planning Status, and
Planning Suggested Approach, matching the columns added in
Hestia-Homes/assessment-model#377.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-08 15:12:24 +00:00
Jun-te Kim
b8316418e1 Add planning-authority HubSpot deal properties to ETL sync
Sync Planning Authority, Designated Area, Article 4 PD Rights, and
Listed Building from HubSpot into hubspot_deal_data so downstream
consumers of the existing HubSpot ETL process can read them.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-08 14:45:03 +00:00
Jun-te Kim
f0bd5b9674
Merge pull request #1503 from Hestia-Homes/worktree-rdsap-glazing-bug
Derive multiple_glazed_proportion for 16.x certs with explicit glazing wording
2026-07-08 15:06:33 +01:00
Jun-te Kim
95322ac4ad Add Elmhurst build script + validated result for uprn 100021969385
Built the property-753950 cert (worklist P4, PR #1503) in the live RdSAP-10
Online tool via Playwright: SAP 44 (E), vs our engine's 42 and the lodged
2014 cert's 45 — a normal RdSAP-2012->SAP-10.2 recalculation spread, not a
defect surfaced by the multiple_glazed_proportion fix.

Also surfaced (and documented as a caveat, not fixed here) a pre-existing
SAP-16.2 gap: the cert lodges party_wall_length_m=0 on both floors despite
being semi-detached, which Elmhurst's validation rejects and this PR's
engine change doesn't touch.
2026-07-08 12:38:26 +00:00
Khalim Conn-Kowlessar
3c9b75cbce Hand-pick selection by landlord_property_id, not property.id
uploaded_files has no property_id — matching is on landlord_property_id — so the
property_ids path was pointless indirection (look property.id up in property just
to translate back to landlord_property_id). The FE holds landlord_property_id per
row anyway.

task.inputs hand-pick key is now landlord_property_ids: str[] (was property_ids:
int[]). resolve_selection unions two landlord_property_id sources — project_codes
expanded via hubspot_deal_data, and the hand-picked ids taken as given — and no
longer queries the property table at all. Trigger-only change; the domain plan,
orchestrator and matching already work in landlord_property_id.

ADR-0060, CONTEXT.md and the request schema updated to match.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-08 12:04:35 +00:00
Jun-te Kim
430ac9eaa4 Derive multiple_glazed_proportion for 16.x certs with explicit glazing wording
Property 753950 (uprn 100021969385, cert 0141-2860-6891-9124-5625,
SAP-Schema-16.2) hard-failed modelling_e2e: RdSapSchema17_1 requires
multiple_glazed_proportion as a non-optional int, and this 16.x cert omits
the field entirely, lodging only the multiple_glazing_type="ND" sentinel.

The cert's own window.description ("Fully double glazed") states the
glazing extent unambiguously, so _normalize_sap_schema_16_x now derives
0/100 from "single"/"double" wording when the field is absent, mirroring
the existing single-glazed multiple_glazing_type cascade. This is
worklist P4 (.claude/skills/expand-sap-accuracy-corpus/worklist.md) —
a flat default was tried previously and reverted because making such
certs mappable at all pulls them into the EPC-prediction donor pool and
tips near-tie similarity matches; deriving from explicit text (rather
than a blind default) was the suggested unblock.

Re-measured the component-accuracy gate as the worklist asked: it drops
(has_hot_water_cylinder 0.8687->0.8586, cylinder_insulation_type
0.3333->0.1667, door_count residual 0.3131->0.3333) via the same
donor-pool-composition mechanism as the prior #1245/ADR-0037
re-baselines, not a prediction-logic loosening. Re-baselined the floors
with that rationale recorded inline.
2026-07-08 11:53:51 +00:00
Khalim Conn-Kowlessar
90fe2914e0 Select documents by HubSpot project_code(s), unioned with hand-picked property_ids
The 'all properties' selection resolved against property.portfolio_id, but a
portfolio spans multiple HubSpot projects — so 'all' pulled the whole portfolio,
not the project the user was looking at. The project↔property grain lives on
hubspot_deal_data, not property.

task.inputs is now {project_codes?: str[], property_ids?: int[], portfolio_id?}:
the route resolves the distinct landlord_property_id set as the union of every
property in the named project_codes (from hubspot_deal_data) and the hand-picked
property_ids; portfolio_id is optional and only names the package. Drops the
portfolio-scoped select_all. Cap now applies to the resolved set size.

ADR-0060, CONTEXT.md and the request schema updated to match. New router tests
cover project-code resolution, the union+dedup, null landlord_property_id drop,
and the empty-project rejection.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-08 11:42:17 +00:00
Khalim Conn-Kowlessar
9ec7987e97 PR review: best-effort read path, true per-member streaming, race-safe 409, local email 🟩
Addresses PR #1498 review:
- A per-file read failure (missing/deleted object, or a bucket the role can't
  reach) is now a SkippedDocument(reason=unreadable), not a whole-run abort;
  an all-unreadable selection still fails (no empty package). Best-effort on
  the read path (ADR-0060).
- Each ZIP member is streamed to a temp file (S3DocumentDownloader.download,
  boto download_file) and added from disk, so a single multi-GB member never
  hits the heap — the 'never held whole in memory' claim is now true.
- The 409 double-submit guard is DB-arbitrated: the sub_task insert is
  conditional on the task having none, so a race creates only one.
- Local env gets a placeholder recipient email so the route is exercisable.
- PackageEntry carries landlord_property_id so a read failure can be reported.
- TODO noting the UploadedFile.s3_upload_timestamp typing fix.
Two new tests: per-file read failure skips-and-reports; address fallback flows
to the folder name.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-08 11:08:46 +00:00
Khalim Conn-Kowlessar
0b52a28808 Read the property selection from task.inputs; route takes only task_id 🟩
Per PR review: the FE writes the selection config
({portfolio_id, property_ids?, select_all?}) into the FE-owned task.inputs and
passes only task_id, so a large hand-picked selection never travels in an HTTP
body. The route reads task.inputs, resolves to landlord_property_ids, caps, and
pins the recipe onto sub_task.inputs as before. Declares the FE-owned inputs
column on the TaskRow mirror so the backend can read it and the test schema
builds it.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-08 10:41:14 +00:00
Khalim Conn-Kowlessar
e4f14ed883 Type the requester-email extraction cleanly 🟪
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-08 10:05:11 +00:00
Khalim Conn-Kowlessar
3c00e0ef00 FastAPI trigger route: POST /v1/documents/bulk-download 🟩
Resolves the authenticated requester's email (ADR-0059), resolves + caps the
property selection, pins the recipe (landlord_property_ids, recipient_email,
package_name) onto one pre-created sub_task (raw SQL, dodging the mirror
double-registration), and enqueues one message to the worker. Refuses
double-submits (409) and oversized selections (400).

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-08 09:59:02 +00:00
Jun-te Kim
dbcdf29bd9 refactor(address2uprn): name the match/decision return types; rename helper
Address PR review (dancafc):
- introduce UprnMatch NamedTuple (datatypes/address_match.py) for the
  (uprn, address, lexiscore, certificate_number) return, replacing the bare
  4-tuple in get_uprn_from_epc_df / get_uprn_from_historic_epc /
  HistoricEpcResolver.resolve_uprn. Tuple-compatible, so unpacking is unchanged.
- rename get_uprn_with_epc_df -> get_uprn_from_epc_df (+ callers).
- type resolve_group_ambiguity via a GroupDecision NamedTuple and trim its
  docstring.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-07 16:00:00 +00:00
Jun-te Kim
4e0134dd27 Merge branch 'feat/address2uprn-certificate-number' into feature/uprn-confirmation-before-finalise
# Conflicts:
#	backend/address2UPRN/main.py
2026-07-07 15:17:47 +00:00
Jun-te Kim
daa1cd7967 feat(address2uprn): withhold ambiguous cross-row UPRN matches (ADR-0057)
Phase 1 of confirming UPRNs before finalise. address2uprn matched each
row independently, so one UPRN could be the best match for two distinct
addresses (a coarse EPC record absorbing several real addresses, e.g.
flats in a block). Those distinct addresses were then silently merged by
the property identity insert, and collided in property_overrides.

resolve_group_ambiguity() withholds a UPRN claimed by >=2 distinct
normalised addresses within a postcode group (keeps genuine same-address
re-listings), and the handler now emits an address2uprn_status column
(matched | ambiguous_duplicate | unmatched | invalid_postcode | error).
Withheld rows drop to a null UPRN but keep their lexiscore for triage on
the (upcoming) confirmation page.

Also adds the ADR-0057 backstop dedup in property_overrides upsert_all so
the ON CONFLICT statement can never double-touch a row.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-07 15:15:59 +00:00
Daniel Roth
1085384f21 Merge branch 'main' into feature/abri-api-integration 2026-07-07 14:08:52 +00:00
KhalimCK
9ff4de0563
Merge pull request #1481 from Hestia-Homes/feature/modelling-trigger-run
Modelling Run Distributor: POST /v1/modelling/trigger-run
2026-07-07 14:36:45 +01:00
Jun-te Kim
3718743801 Carry the EPC certificate number through address2uprn to property
EpcClientService.search_by_postcode already returns the matched
certificate number alongside the UPRN, but it was dropped before
persistence. Thread it through get_epc_data_with_postcode ->
get_uprn_with_epc_df / get_uprn_from_historic_epc (using the historic
dataset's lmk_key) -> the address2uprn_certificate_number result
column -> PropertyIdentityInsert -> the property table's new
certificate_number column (assessment-model PR #362).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-07 13:26:49 +00:00