- SAP-Schema-16.3: same reduced-field RdSAP shape as 16.2 — generalise the
normaliser to _normalize_sap_schema_16_x and route both 16.2/16.3 through it.
uprn_44012843 maps → SAP 79 (lodged 81).
- SAP-Schema-17.0: structurally identical to the full-SAP 17.1 schema (measured
sap_opening_types), so it parses with the 17.1 dataclass and reuses
from_sap_schema_17_1 with no normalisation. uprn_10023444324 → 80, uprn_
10023444320 → 81.
- Regression tests (16.3 dispatch, 17.0 dispatch) + sap_16_3.json / sap_17_0.json
fixtures; 0 new pyright errors. All 7 e2e UPRNs now map.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
SAP-Schema-16.2 (datatypes/epc/domain/mapper.py):
- 16.2 is structurally an RdSAP-17.1 cert under a different name; add
_normalize_sap_schema_16_2 (field renames + defaults) and dispatch to the
tested from_rdsap_schema_17_1 mapper. uprn_100020933699 maps → SAP 71.
- Honour a "Single glazed" windows description when multiple_glazing_type="ND"
(was defaulting to double) → RdSAP-21 code 5; eng 72→71 (lodged 70).
- 4 regression tests + sap_16_2.json fixture; 0 new pyright errors.
Flat party-wall fix (domain/sap10_calculator/worksheet/heat_transmission.py):
- Full-SAP flats carry flatness in dwelling_type, not property_type, so the
party-wall default fell through to the 0.25 house value instead of the RdSAP
Table-15 flat 0.0. Add _is_flat_or_maisonette_dwelling fallback + regression
test. uprn_10093116529 80→81 (matches the cert's lodged party u_value 0).
Accuracy corpus pins (tests/domain/sap10_calculator/test_real_cert_sap_accuracy.py):
- uprn_10093116543 (SAP-17.1 gas-combi semi): engine 81 (Elmhurst 77; documented
full-SAP→RdSAP residual — measured wall/floor U + PCDB boiler vs RdSAP defaults).
- uprn_10093116529 (SAP-17.1 g/f flat): engine 81 (Elmhurst 78).
devcontainer: add poppler-utils (pdfinfo) for the documents-parser PDF fixtures.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Golden regression fixture for the multi-feature dwelling that surfaced the
two Elmhurst-extractor bugs in a33707f8. case 43 is a 2-BP mid-terrace with
a DETAILED room-in-roof (two slopes, two flat ceilings, party + exposed
gables, two common walls), a MIXED-insulation multi-section roof (Main
insulated + Extension uninsulated 2.30), a DRY-LINED extension solid wall,
a mains-gas boiler (102 / control 2106) and a House-coal solid-fuel
secondary (633).
Routes the Summary PDF through the WHOLE extractor + mapper + calculator
pipeline (no hand-built EpcPropertyData) and pins the §3 fabric + SAP-rating
block at abs=1e-4: (29a) walls 74.5800, (30) roof 38.5008, (33) fabric
172.7844, continuous SAP 73.2332 = (258), CO2 3518.3037 = (272). Guards the
detailed-RR slope/common_wall surfaces, the dry-lining R=0.17 adjustment,
and the per-part mixed-roof billing together. Summary mirrored to
backend/documents_parser/tests/fixtures/Summary_001431_case43.pdf; provider
module mirrors the _case6/_case21 pattern, assertion in
test_section_cascade_pins. Harness 47/47; regression = the 3 pre-existing
fails; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two compensating Summary-extractor bugs surfaced by simulated case 43 (a
2-BP mid-terrace with a detailed room-in-roof + a dry-lined extension wall).
Their fabric errors nearly cancelled (walls net −0.76 W/K), hiding both
behind a deceptively small +0.05 SAP delta.
Bug 1 — main/extension wall dry-lining never read. The §7 "Dry-lining:
Yes/No" line was parsed only for ALTERNATIVE walls; the main/extension
WallDetails dropped it, so a dry-lined solid wall was billed at its
un-adjusted base U. RdSAP 10 §5.8 + Table 14: a dry-lined uninsulated wall
adds R=0.17 → U = 1/(1/U_base + 0.17). Case 43 Ext1: solid brick 1.70 →
1.32. Added `WallDetails.dry_lined`, read it in the extractor (both the
main-wall builder and the As-Main copy), threaded it to the domain
`wall_dry_lined` (emit None when undried — cascade-equivalent to False,
keeps the field absent for the non-dry-lined majority).
Bug 2 — the LAST room-in-roof surface row's U over-read. The per-row token
scan stops at the next RIR-row name; the final surface (no successor) over-
read into the following section, shifting the trailing-token slotting and
silently zeroing its `default_u` (case 43 Common Wall 2: 1.90 → 0.00 → the
2.4 m² common wall billed at U=0 instead of the main-wall 1.90). Stop the
scan at the row's natural end — the "Yes"/"No" u_value_known flag plus the
trailing u_value numeric.
Case 43 now reproduces the P960 EXACTLY: (29a) walls 74.5800, (33) fabric
172.7844, continuous SAP 73.2332 = (258), CO2 3518.30 = (272), all <1e-4
(was SAP +0.0455 / CO2 −8.04). Harness 47/47 0 raised; regression = the 3
pre-existing fails; pyright net-zero (51=51).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`u_roof` only implemented the joist column, so roofs lodged insulated at
rafters (`roof_insulation_location == 1`) were mis-billed at the joist U
on both the API and Summary paths — under-stating loss, over-rating SAP.
RdSAP 10 §5.11.2 Table 16 (spec p.42-43) gives a distinct "insulation at
rafters" column (2): the rafter cavity is shallower than a loft void, so
the same depth yields a higher U (200 mm: rafters 0.29 vs joists 0.21).
§5.11 Table 18 (p.45) likewise carries a rafters column (2) for unknown /
as-built thickness (footnote (1): "The value from the table applies for
unknown and as built") — band A-D = 2.30, E = 1.50, F = 0.68, diverging
from the joist column's 100 mm-equivalent 0.40 default (footnote (4)).
- add `_ROOF_RAFTERS_BY_THICKNESS` (Table 16 col 2) + `_ROOF_RAFTERS_BY_AGE`
(Table 18 col 2) to rdsap_uvalues; `u_roof` selects them via a new
`insulation_at_rafters` flag (ignored for flat / sloping-ceiling roofs).
- `heat_transmission` derives the flag PER BUILDING PART from
`roof_insulation_location` (gov-API int 1 / Summary "R Rafters"), which
also fixes the multi-part dedup-roof-join problem: each part's own
location now drives its U, replacing the unattributable joined
`epc.roofs[]` description.
Worksheet-validated to 1e-4: simulated case 41 (4-bp — Ext1 rafters 200mm
→ 0.29, Ext3 rafters As-Built band F → 0.68; roof total 24.8350) and case
42 (6 variants — rafters 50mm → 0.88, rafters unknown band C → 2.30,
joists/none unchanged). Case 40 stays exact (roof 35.340, total 441.1606);
worksheet harness 47/47.
Corpus within-0.5 66.9% → 66.5% (gates 0.65/1.08 hold) — a spec-correct
shift, NOT a regression: all 15 corpus rafter certs carry redacted (None)
thickness yet lodge roof EER 2-4 (insulated), so the open API blanked a
specified thickness and the spec's unknown-rafter 2.30 default correctly
over-states them. Recovery needs a roof-EER→thickness inference on the
API path (follow-up), not a change to the U-table.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary §15.1 lodges "Cylinder Size: Value known" with the
measured volume in the "Cylinder Volume (l)" line — the Summary-path
equivalent of the gov-API "Exact" descriptor. The mapper had no entry for
"Value known" so `_elmhurst_cylinder_size_code` raised UnmappedElmhurstLabel,
and even once mapped the measured volume was never threaded through, so the
cascade dropped the cylinder storage loss (~468 kWh/yr) from (219) water
heating on every measured-volume-cylinder Summary.
Per RdSAP 10 §10.5 Table 28 (p.55) a measured cylinder volume is used
directly. Map "Value known" → cascade code 6 (Exact) and thread the §15.1
"Cylinder Volume (l)" value into SapHeating.cylinder_volume_measured_l, which
`_cylinder_volume_l_from_code` (cert_to_inputs.py:5281) already reads for
code 6 — mirroring the gov-API path (mapper.py:1575/1885).
Pins simulated case 39 (P960-0001-001431): an age-A mid-terrace on direct-
acting electric room heaters (SAP code 691, cat 10, control 2602) with
electric-immersion DHW off a 117 L "Value known" cylinder. The full
extractor→mapper→calculator cascade now reproduces the worksheet's SAP-rating
block EXACTLY — SAP value 36.6365 (band F) and (272) CO2 2056.0731 kg/yr,
with (219) water heating 2637.5049 and (255) total energy cost 1802.0039.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Reduced-field window U: heat_transmission derived the synthesised-window
raw U from u_window(all None) -> the 2.5 placeholder regardless of glazing.
Now routes the (uniform) glazing_type code through u_window (RdSAP Table 24)
so e.g. double pre-2002 reads 2.8, not 2.5. Only the pre-SAP10 reduced-field
path is affected (21.0.1 certs carry per-window U upstream) — the RdSAP-21.0.1
corpus gauge is unchanged at 66.9% within-0.5.
test_real_cert_sap_accuracy: pin uprn_10002468137 (RdSAP-17.1, all-electric
storage heaters) at SAP 61, validated against Elmhurst on identical inputs
(dual off-peak immersion, 110 L cylinder, 2 baths). Our engine reproduces
Elmhurst's fuel cost to the penny; lodged 55 is the old SAP-2012 schema.
Tooling to grow the accuracy corpus:
- scripts/fetch_real_life_epc_sample.py — capture a cert by UPRN into the corpus.
- scripts/compare_epc_paths.py — diff gov-API vs Elmhurst-summary EpcPropertyData
and run both through the engine, localising mapper vs calculator differences.
- skill validate-cert-sap-accuracy — the end-to-end loop (capture -> Elmhurst
inputs -> human builds -> compare -> reconcile -> pin in the test).
- skill epc-to-elmhurst-rdsap-inputs reference: corrected immersion (code 1=dual),
cylinder size (code 2 = Normal/110 L), and bath-count (WWHRS sub-tab) mappings.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The realistic re-generation of case 37 (code-117 gas boiler, control 2102,
+ a MAINS-GAS condensing gas-fire secondary code 611, vs case 37's biogas
605). The full extractor -> mapper -> calculator pipeline reproduces the
worksheet's SAP-rating block EXACTLY: continuous SAP 60.9152 (Δ 2e-5) and
(272) CO2 5801.0770 (Δ ~0). This confirms the boiler-efficiency /
control-2102 −5pp interlock / secondary-fuel handling are all correct, and
that case 37's +7 gap was purely the biogas sub-fuel the Summary export
cannot carry.
Summary mirrored into backend/documents_parser/tests/fixtures so the pin
runs without the unstaged workspace. PE not pinned — it is a separate
DPER block (different scope) already guarded by the corpus PE gauge.
Worksheet harness 47/47 unchanged; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The §11 layout parser keys a window's wall Location on the glazing-prefix /
orientation tokens around its data row. An alt-wall window lodges its
"Alternative wall 1" Location wrapped across the lines bracketing the W×H×A
row. For a DOUBLE-glazed alt window the prefix line also carries the glazing
phrase ("Double between 2002 Alternative wall"), so the partition breaks
there and the location survives into the window's pre-data slice. For a
SINGLE-glazed alt window the "Alternative wall" line stands alone with no
glazing-type word, so _partition_after_manuf scanned past it and swallowed
it into the PREVIOUS window's suffix — the window then defaulted to
"External wall" and its opening deducted from the wrong wall.
Fix: treat a standalone wall-location line ("Alternative wall" / "External
wall" / "Party wall") as a window boundary in _partition_after_manuf, so it
attaches to the following window's prefix. Surfaced by simulated case 34
(cert 001431 electric-storage flat): 2 of 4 single-glazed alt-wall windows
were mis-allocated, splitting 2.75/10.78 m² instead of the worksheet's
4.63/8.90 corridor/external opening areas.
Elmhurst-extractor only; API gauge unaffected. Regression gate green (3
pre-existing fails unrelated); worksheet harness 47/47 unchanged. Case 34's
alt-wall opening area now matches the worksheet; the corridor wall net area
is correct (the cert's residual is now isolated to the unheated-corridor
door, a separate slice).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary §7 lodges "Alternative Wall N Sheltered Wall: Yes" for
a sub-area adjacent to an unheated buffer (e.g. a flat's corridor wall),
but the extractor dropped it and _map_elmhurst_alternative_wall never set
SapAlternativeWall.is_sheltered — so the cascade billed the sub-area at its
full exposed U instead of the RdSAP 10 Table 4 (p.22) sheltered U =
1/(1/U + 0.5).
The calculator already applies is_sheltered (_alt_wall_w_per_k) and the
gov-API path already wires sheltered_wall=="Y"; this brings the Elmhurst
front-end to parity. Three-part change: AlternativeWall.sheltered field +
_alternative_walls_from_lines parse ("Alternative Wall N Sheltered Wall") +
_map_elmhurst_alternative_wall is_sheltered=a.sheltered.
Surfaced by simulated case 34 (cert 001431 electric-storage flat): the
6.02 m² corridor wall billed at full U=1.50 (9.03 W/K) instead of the
sheltered 0.86 (5.18 W/K) — +3.85 W/K, -1.61 SAP. Post-fix the alt wall
matches the worksheet's (29a) 5.177 and case 34 closes from -1.61 to -0.30
(remaining residual is a separate window/wall area-allocation thread).
Elmhurst-mapper only: API SAP gauge unchanged (57.6% within 0.5); worksheet
harness 47/47 unaffected; regression gate green (3 pre-existing fails
unrelated); pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst dwelling-type classifier keyed "Top-floor flat" on a "dwelling
below" floor lodgement. A single-storey flat exposed BOTH top (a real
external roof) AND bottom (floor over partially-heated space, no dwelling
below) therefore fell through to "Ground-floor flat" — which the cascade's
_dwelling_exposure maps to has_exposed_roof=False, dropping the external
roof entirely.
Surfaced by simulated case 34 (cert 001431 reconfigured as a slimline
electric-storage flat): the worksheet bills (30) External roof = 39.98 m²
x U=2.30 = 91.95 W/K — the dominant heat-loss element — but the cascade
dropped it, under-stating space-heating demand by 42% (6550 vs 11357
kWh/yr) and over-predicting SAP by +21.76 (57.07 vs worksheet 35.31).
Fix: an exposed (non-party) roof puts the flat on the top storey
regardless of what is below it. Classify as "Top-floor flat" whenever the
roof is exposed; the flat's exposed floor is recovered downstream by the
existing per-BP is_above_partially_heated_space / is_exposed_floor override
in heat_transmission (§3). Party-roof flats ("another dwelling above") are
unaffected and stay Ground-/Mid-floor.
This is an Elmhurst-mapper (dwelling_type) bug, NOT a calculator bug: the
calculator correctly trusts dwelling_type, and the gov-API path supplies
the position directly (cert 0036 — a genuine ground-floor flat whose API
data lodges a "Pitched, no access" roof construction under another dwelling
— stays party, 2.51 W/K). API SAP gauge unchanged (57.6% within 0.5);
worksheet harness 47/47 unaffected; case 34 roof now exact (residual -1.61
is a separate flat-corridor wall-U thread). Regression gate green (3
pre-existing fails unrelated).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
When a property lodges an Alternative Wall, pdftotext interleaves the §11
"Location" column ("Alternative wall 1") into the wrapped glazing-TYPE cell,
producing labels like "Double between 2002 Alternative wall and 2021 1
Alternative wall" (cert 001431 storage-heater variants, simulated case 34).
The existing greedy trailing-suffix strip (\s+Alternative wall.*$) truncates
at the FIRST "Alternative wall", losing "and 2021" and yielding the
unmatchable "Double between 2002". Added a fallback that removes EVERY
"<External|Alternative|Party> wall [n]" fragment and any stray 1-2 digit
location index from the raw label, then retries the lookup. Loss-free: no
glazing-type key contains a wall-location phrase or a bare 1-2 digit number
(install-date years are 4 digits).
Unblocks the Summary cascade for any property with an Alternative Wall;
Summary-path only (the API path receives structured glazing codes, so the
API gauge is unaffected). Regression gate green (1 pre-existing fail
unrelated).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary section 15.1 "Hot Water Cylinder" block lodges
"Immersion Heater: Dual" / "Single"; the extractor dropped it, so the
Summary path left immersion_heating_type = None while the API path already
captured it. Capturing it drives SAP Table 13's high-rate-fraction
DHW-cost split (RdSAP 10 section 10.5 p.54: 1 = dual, 2 = single) and
brings the two front-ends to parity.
Three-file change: WaterHeating.immersion_type field +
_extract_water_heating parse (scoped to the 15.1..15.2 slice) +
_elmhurst_immersion_type_code mapper (strict-raise on an unmapped label,
mirroring _elmhurst_cylinder_insulation_code).
Safe to land now that the preceding commit zeroes the high-rate fraction
for 18-/24-hour tariffs: the 20 solid-fuel corpus certs (solid fuel 4-11:
WHC 903 dual immersion, 18-hour meter, 110 L) carry a dual immersion, but
their 18-hour tariff bills 100% low-rate per Table 12a's 7-/10-hour scope
— so they stay EXACT instead of regressing to the 10-hour-column ~0.10.
7-/10-hour Summary immersion certs now correctly cost the Table 13
high-rate fraction instead of falling to the immersion=None 100%-low
default.
Regression gate green (3 pre-existing fails unrelated); API gauge
unchanged (Summary-path-only): 57.6% within 0.5, mean|err| 1.185.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
pdftotext can wrap the §11 building-part column onto the glazing-TYPE
token without an intervening glazing-gap descriptor, e.g. "Double between
2002 and 2021 1st" (the "1st" marks the 1st Extension). The existing
trailing-gap fallback only strips the fragment when preceded by "N mm";
the bare ordinal raised UnmappedElmhurstLabel.
New `_ELMHURST_GLAZING_LABEL_TRAILING_BP_RE` strips a trailing ordinal
("1st"/"2nd"/…) or "Main" and retries the lookup. No glazing-type key
ends in an ordinal or "Main", so it is loss-free. Surfaced by worksheet
`simulated case 33` (direct-acting electric boiler + immersion), which
previously could not be routed through the Summary cascade.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_separately_timed_dhw` returned True for any boiler+cylinder+from-main
cert, applying the SAP 10.2 Table 2b note b) ×0.9 temperature-factor
reduction unconditionally. For the lpg-boiler "before" worksheet (pre-
1998 LPG boiler SAP code 115 + 210 L cylinder, NO cylinder thermostat,
control 2113 "Room thermostat and TRVs" — no programmer) this dropped
the (53) temperature factor to 0.702 (= 0.60 × 1.3 × 0.9) where the
worksheet lodges 0.78 (= 0.60 × 1.3), under-counting cylinder storage
loss (55) by ~119 kWh/yr and over-rating SAP by ~0.25.
RdSAP 10 §10.5 (PDF p.57) "Hot water separately timed":
No programmer, pre-1998 boiler → No
Programmer, pre-1998 boiler → Yes
Post-1998 boiler → Yes
DHW is therefore NOT separately timed only when a pre-1998 boiler is
paired with a no-programmer control. Add the two SAP 10.2 Table 4c(2) /
Table 4b lookups (controls without a programmer = {2101, 2103, 2111,
2113}; pre-1998 gas/LPG boilers 110-119 + oil 124/125/128) and return
False for that combination; every other boiler+cylinder cert keeps the
separately-timed default, so the change is confined to old low-control
stock and the heating corpus + goldens are unchanged.
Effect: the full chain (Summary PDF → extractor → mapper → cert_to_inputs
→ calculator) now reproduces the lpg-boiler worksheet's §11a unrounded
SAP -6.6499 at abs < 1e-4 (was -6.4013). Full regression suite green bar
the 3 pre-existing unrelated fails.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
An LPG-boiler dwelling on the Summary → from_elmhurst_site_notes path
mapped to main_fuel_type=26 (mains gas), making it indistinguishable
from a mains-gas boiler downstream — wrong Table 12/32 cost / CO2 / PE
(bottled LPG is ~10.30 p/kWh vs mains gas 3.48), and it defeats any
"non-gas → gas only with a mains-gas connection" gate (an LPG dwelling
looks already-gas).
Root cause: the recommendation worksheets lodge the boiler carrier as
§15.0 "Water Heating Fuel Type: Bottled gas" (§14.0 carries only SAP
code 115, a Table 4b gas-family row, + "Main gas: Yes" in §14.2 — a
mains-gas CONNECTION, not the heating fuel). "Bottled gas" was absent
from `_ELMHURST_MAIN_FUEL_TO_SAP10`, so the §15.0 fuel resolved to None
and `_elmhurst_gas_boiler_main_fuel` fell through priority-1 to the
mains-gas meter flag → 26.
Map "Bottled gas" → 3 (bottled LPG MAIN heating): code 3 routes via
`API_FUEL_TO_TABLE_32`/`API_FUEL_TO_TABLE_12` → Table-code 3 (10.30 /
9.46 p/kWh). NOT the legacy "LPG bottled": 5 entry — API code 5 =
anthracite, and `canonical_fuel_code` resolves the same-valued Table-32
code 5 to anthracite (3.64 p/kWh), so a 5 here mis-prices the dwelling
as cheap solid fuel (verified: a 5 mapping moved SAP the WRONG way,
42.33 → 45.11; code 3 moves it to -6.40 vs the worksheet's -6.6499).
Also add 3 to `_GAS_LPG_MAIN_FUEL_CODES` so the §15.0-lodged bottled-LPG
water fuel is adopted as the boiler's space-heating carrier (priority 1)
instead of the meter flag.
Effect: main_fuel_type=3 (bottled LPG) and water_heating_fuel=3 (was
None). Mains-gas certs still → 26 (full regression suite green bar the 3
pre-existing unrelated fails); the MissingMainFuelType tripwire still
fires for genuinely-undeterminable carriers.
Spec: SAP 10.2 Table 12 / RdSAP 10 Table 32 (PDF p.95) — bottled LPG
main heating fuel code 3.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_elmhurst_dwelling_type` derived a flat's roof exposure from
`room_in_roof is not None`, so a top-floor flat whose roof is a plain
external "PS Pitched, sloping ceiling" (no room-in-roof) fell through to
"Mid-floor flat". The cascade's `_dwelling_exposure` then treats a
mid-floor flat's roof as a party ceiling (RdSAP 10 §5 / §3 — party
surfaces carry no heat loss) and drops the entire roof term: cert
001431's 105 m² roof at U=2.3 = 241.68 W/K (30) vanished, collapsing
(33) fabric heat loss 320.06 → 78.38 and over-rating SAP by ~5 points
(on top of the age-band roof-U bug — see prior commit).
Read the roof TYPE instead — the dual of the floor's "Another dwelling
below" signal. A flat's roof is a party ceiling only when its Elmhurst
code is S / A / NR (Same/Another dwelling or Non-residential space
above); F / PN / PA / PS are exposed external roofs, so the dwelling is
on the top storey. `has_exposed_roof = room_in_roof present OR
_elmhurst_roof_is_exposed(roof)` — which is exactly what the function's
own docstring already described as the intent ("RR present or external
roof"), now implemented.
With both upstream fixes the full chain (Summary PDF → extractor →
mapper → cert_to_inputs → calculator) reproduces the worksheet's §11a
unrounded SAP 56.3649 at abs < 1e-4, with (30)/(33)/(37) matching to
the decimal. Only flat fixture reclassified; 000784 (top-floor, RR) and
000910 (ground-floor) unchanged. Regression suite green bar the 3
pre-existing unrelated fails.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary §3.0 "Date Built" lodges the per-building-part age
bands; the Main row reads "Main Property" / "C 1930-1949". But "Main
Property" ALSO heads the §4.0 Dimensions table, so the global
`_str_val("Main Property")` collides with it: when pdftotext renders
"3.0 Date Built:" glued onto its "Main Property" row token on one
layout line (as the recommendation worksheets do), the first standalone
"Main Property" match is the §4 dimensions header — returning its next
token "Floor" as the "age band".
That garbage age propagated to `u_roof`: for a "Pitched, sloping
ceiling" (PS) roof with no lodged insulation thickness, `u_roof` returns
the spec uninsulated U=2.3 for the correct age C but U=0.4 for the
unparseable "Floor" — collapsing the roof heat-loss term and inflating
SAP by ~14 points on the affected cert.
Scope the read to the Date-Built block (between "3.0 Date Built" and
"4.0 Dimensions") and take the first age row — a line beginning with a
single A-M band letter + space ("C 1930-1949", "A before 1900",
"J 2003-2006"). Building-part name rows never start that way, and the
Main row precedes any extension / room-in-roof rows.
Regression: full sap10_calculator + documents_parser suite green bar the
3 pre-existing unrelated fails (2 stone-wall U tests, test_total_floor_
area); the multi-bp / "A before 1900" fixtures (000516, 001431_case*,
6035) keep their age bands.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pulls in 42 commits of calculator/mapper accuracy fixes from the per-cert
mapper-validation and floor/roof/heating fronts.
Conflict resolutions:
- mapper `_is_elmhurst_roof_window`: main dropped the branch's "wall location →
vertical" guard (it broke cert 000516's rooflight), but that re-broke cert
001431's two External-wall U>3.0 windows (which must stay vertical). The two
certs lodge a BYTE-IDENTICAL §11 row, so neither location nor U separates
them — the real discriminator is the room-in-roof context. Replaced the
unconditional U>3.0 backstop with one gated on the BP having a room-in-roof
(`_elmhurst_bp_has_room_in_roof`): 000516's Main BP has a "Room in roof type
1" (→ rooflight), 001431's does not (→ vertical). Validated against BOTH —
full Elmhurst worksheet suite 1038 pass + the 001431 window-extraction pin.
- property_postgres_repository: kept main's `ids_by_uprn` method + the branch's
`_restrictions_of` helper.
- sap_fuel.py: the branch relocated it to domain/billing/ (already carrying
main's to_table_32_code normalization), so kept the old path deleted.
Fallout from main's fabric fixes (validated by the boiler-3 real-cert pin which
still reproduces at delta 0):
- re-pinned the boiler-1 + boiler-instant-hw ASHP snapshot scores;
- main's §14.2 gas-boiler main-fuel derivation resolved the BGB/102 baseline
gap, so `test_gas_boiler_instant_hw_before_baselines` is now a passing test
(was an xfail tripwire).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A Summary §14.0 Table 4b gas boiler (SAP code 101-119) lodges no §14.0
"Fuel Type" string in the newer Elmhurst export. The carrier was resolved
only from §15.0 "Water Heating Fuel Type" — fine when the same boiler
heats the water, but a gas boiler paired with a SEPARATE electric
immersion lodges §15.0 "Electricity", so `_elmhurst_gas_boiler_main_fuel`
returned None and the cascade strict-raised MissingMainFuelType.
Cert 001431 boiler-1/boiler-2 "before" variants are exactly this config:
§14.0 SAP code 102/104 (mains-gas boiler), §15.0 electric immersion
(code 909), §14.2 Meters "Main gas: Yes". The meter flag is the
authoritative carrier signal — a 101-119 boiler on mains gas burns mains
gas — so adopt it (SAP10 main_fuel 26 per _ELMHURST_MAIN_FUEL_TO_SAP10
"Mains gas") when §15.0 can't disambiguate. §15.0 gas/LPG still wins when
present (keeps LPG-vs-mains-gas precision); no mains-gas meter + non-gas
§15.0 still strict-raises rather than guessing.
Spec: SAP 10.2 Table 4b "Seasonal efficiency for gas and liquid fuel
boilers" (PDF p.168), rows 101-119. Both certs now resolve main_fuel=26
and compute (was: hard raise).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A 440 mm (>420 mm) solid brick AS-BUILT wall computed U = 1.70 (the
220 mm bucket default) instead of the RdSAP-correct 1.10. The §5.7
Table 13 thickness path only fired for *insulated* brick (external/
internal + thickness > 0); the as-built case fell through to the
Table 6 cavity/solid age-band default.
Spec: RdSAP 10 Specification (9th June 2025), §5.7 "U-values for
uninsulated brick walls, age bands A to E", Table 13 (PDF p.40):
≤200 mm → 2.5, 200–280 mm → 1.7, 280–420 mm → 1.4, >420 mm → 1.1.
Table 6 footnote (b) on the "Solid brick as built" row (PDF p.40):
"Or from 5.7 if wall thickness is other than 200mm to 280mm" — the
thickness table supersedes the flat 1.7 default whenever a documentary
wall thickness is lodged (200–280 mm gives 1.7 either way). The §5.8 /
Table 14 dry-lining R is added on top only when the wall is dry-lined,
per the §5.7 closing sentence.
Validated against the user-generated Elmhurst worksheet "simulated
case 21" (replica of API cert 2818-3053-3203-2655-9204: mid-terrace,
age band B, solid brick as-built 440 mm, room-in-roof). New §3 cascade
pin `test_section_3_wall_u_by_thickness_case21_match_pdf` routes the
Summary through the real extractor + mapper and pins:
(31) 155.1000, (33) 175.6208, (36) 23.2650, (37) 198.8858 — all 1e-4.
External walls Main U → 1.1000; Sheltered RR gable → 1/(1/1.10+0.5) =
0.71 (was 0.92). Pinned on §3 only (case-6 precedent): its code-908
instantaneous multi-point gas water heater has a separate §4 (219) gap.
Cross-check: sim case 20 (220 mm) stays at 1.70 — unchanged.
API SAP accuracy (scripts/eval_api_sap_accuracy.py, 896 computed certs):
% |err| < 0.5 SAP vs lodged: 42.6% → 43.8%; mean |err| 2.045 → 2.010.
Regression: tests/domain/sap10_calculator/ (1861), backend/
documents_parser/tests/ (574), datatypes/epc/ + rdsap golden fixtures
all green (pre-existing test_total_floor_area excepted). pyright strict
net-zero. No solid-brick fixture pin shifted (200–280 mm unchanged).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A Detailed room-in-roof lodges "Stud Wall" surfaces, but the cascade billed
every one through Table 17 from its insulation — over-counting fabric on
internal studs that carry no heat loss. sim case 20's two studs lodge §8.1
Default U-value 0.00 and the P960 worksheet omits them from BOTH fabric heat
loss (§3: (33)=285.9847) and total exposed area (31)=239.68; the cascade
computed ~0.52 each → (33) +4.16 W/K and continuous SAP 43.05 vs 43.6322.
Gate the drop on the lodged Default U-value: 0.00 → internal knee wall,
return None (no heat loss, no area); positive → a real exposed knee wall
(cert 000565 Ext2 Detailed: 0.31 / 0.10) that still falls through to the
Table-17 path. The earlier over-broad "drop all studs" zeroed 000565's
genuine studs — this keeps them.
Pins test_summary_001431_case20_fabric_heat_loss_matches_worksheet_line_33
((33)=285.9847 at 1e-4); case 20 continuous SAP now EXACT (43.6322). 2850
pass (the lone test_total_floor_area failure is pre-existing on base);
pyright strict net-zero (32=32).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Sim case 20's §11 lodges 5 windows but only 1 surfaced. The "W H Area"
cells tokenize inconsistently: a narrow Area column keeps all three on one
line ("1.80 2.10 3.78" — matches _WIDTH_HEIGHT_AREA_RE), but a wider Area
column triggers pdftotext's 2+-space split, dropping the Area onto its own
line ("5.79 2.00" then "11.58"). The 3-decimal data anchor never matched
those four rows, so they were lost — gutting §6 solar gains (5 windows →
1) and dropping continuous SAP 43.05 → 38.32 vs the worksheet's 43.6322.
Pre-merge a "W H" line + a following lone-decimal Area into the canonical
"W H Area" line, gated on Area ≈ W × H (the §11 Area is always the product)
so a frame factor / g-value / U-value below a dimension line is never
absorbed. One-line layouts (3 decimals) are untouched.
Pins via test_summary_001431_case20_extracts_all_five_section11_windows
(Summary_001431_case20.pdf mirrors sap worksheets/golden fixture debugging/
simulated case 20/). 573 documents_parser tests pass; pyright strict net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>