Commit graph

105 commits

Author SHA1 Message Date
Khalim Conn-Kowlessar
8606cab5f0 fix(pv): credit PV only when connected to the dwelling's meter 🟩
Gate PV generation/credit in cert_to_inputs on gov-API pv_connection:
credit only when ==2 ('connected'); ==1 ('present but not connected to the
dwelling's meter') contributes zero to the dwelling's cost/CO2/PE per
RdSAP 10 §11.1 / SAP 10.2 Appendix M. Non-int (None / site-notes str) keeps
the credit-if-array behaviour, so the Elmhurst/Summary + synthetic paths are
unchanged (no regression).

Corpus: all 5 pv_connection=1 PV certs move inside ±0.5 (e.g. 100051118081
+6.5→+0.5); MAE 0.760→0.740, within-0.5 73.8→74.3%, no regression
(pv_connection=2 certs keep their credit).

Also corrects a now-load-bearing latent bug: the solar-recommendation
overlay tagged recommended arrays pv_connection=1 ('not connected') — which
the new gate would zero. A new install connects to the dwelling's meter, so
it must be 2; pinned by the overlay test.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-29 13:40:51 +00:00
Khalim Conn-Kowlessar
0a2ed67e94 Harden Dwelling-Roof Cap on real data: positional segments, ground-floor basis 🟩
Three corrections found by re-running property 742003 end-to-end:
- roofSegmentStats are POSITIONAL — real responses omit the segmentIndex field
  the fixture happened to carry; key the centre/area lookup by array position.
- Base the cap on ground_floor_area (the footprint the roof covers), not the
  greatest per-storey area; roof_area is the fallback.
- Clamp the basis by total_floor_area: predicted EPCs borrow the structural
  template's geometry (742003: a 118.62 m² MAIN ground floor) decoupled from
  the predicted 55 m² (ADR-0029), so without the clamp the cap reads the
  template's larger footprint.

Result: 742003 plan A/92.4 (16 kWp) -> C/74.4 (6.4 kWp). 29 solar tests +
orchestration threading + products green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-26 12:24:52 +00:00
Khalim Conn-Kowlessar
904c205e3a Dwelling-Roof Cap bounds the PV array to the dwelling's own roof 🟥
select_conservative_configs must accept the dwelling's roof area and cap panels
to its usable roof (ADR-0038) — bounding a 55m² dwelling to ~16 panels under
Google footprint conflation, while staying a no-op on correctly-matched homes.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-26 12:15:28 +00:00
Khalim Conn-Kowlessar
cf2780ed77 SolarPotential carries panel dims + per-segment centre/area 🟥
The Dwelling-Roof Cap (ADR-0038) sizes by usable roof area and ranks segments
by distance from the dwelling, so the projection must carry each panel's
footprint and each segment's centre + area (from roofSegmentStats).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-26 12:12:12 +00:00
Jun-te Kim
46fc8f338c
Merge pull request #1289 from Hestia-Homes/fix/solar-missing-max-array-panels
Treat solar block without array sizing as no-solar (fix KeyError maxArrayPanelsCount, 2 e2e failures)
2026-06-24 11:59:57 +01:00
Jun-te Kim
79f89d872e Treat solar block without array sizing as no-solar (fix KeyError)
2 modelling_e2e properties failed with KeyError: 'maxArrayPanelsCount'.

Google returns a `solarPotential` block with no array-level sizing fields
(`maxArrayPanelsCount` / `panelCapacityWatts`) for buildings with no usable
solar estimate. `SolarPotential.from_building_insights` hard-indexed those keys
and crashed the whole property.

Fix: the projection now returns Optional and yields None when those fields are
absent — the established "no solar potential" outcome (the orchestrator and
recommendation path already type it Optional and skip solar on None). Existing
callers (`_solar_potential_for`, harness) already assign to Optional.

Regression test + `assert is not None` narrowing on the valid-fixture tests.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:22:06 +00:00
Khalim Conn-Kowlessar
80d617aa5b modelling: glazing overlay models draught-proofing + frame-factor re-lodge
Fitting sealed glazing units changes two things beyond the pane's U/g
that the cascade reads, which the overlay didn't model — leaving the
double/secondary before→after pins ~0.7 SAP short (xfail):

1. Draught-proofing (RdSAP 10 §8.1). Sealed units draught-proof the panes
   they replace, re-lodging the dwelling-level `percent_draughtproofed`
   (cert 001431: 84 → 100). The §2 cascade reads that dwelling-level
   value, so the overlay now carries it. `_recompute_percent_draughtproofed`
   anchors on the lodged before-% — `after = round((round(before%/100 × N)
   + flips) / N × 100)`, N = openable windows (vertical + roof) + doors,
   flips = upgraded panes that were not draught-proofed — so it's robust
   to incomplete window extraction (unchanged openings are already in the
   aggregate). ~0.3 SAP.

2. Frame factor (§6 solar gains). A replacement unit re-lodges its own
   FF=0.70, overriding the pane it replaced — the two "single glazing,
   known data" panes lodge FF 1.00 / 0.50 (one is 6.6 m²), so leaving them
   unchanged understated solar gains by ~+150 kWh space heating. `WindowOverlay`
   now carries `frame_factor`, written flat onto the window. ~0.4 SAP.

Wiring: `EpcSimulation.percent_draughtproofed` + `WindowOverlay.frame_factor`
new fields; `apply_simulations` / `_fold_window` write them; the glazing
generator computes both from the upgraded set and cert 001431's after.

Un-xfails `test_{double,secondary}_glazing_overlay_reproduces_the_relodged_after`
— both now pin SAP/CO2/PE to the relodged after within tolerance. Updates
the two `test_glazing_recommendation` overlay expectations for the new
`frame_factor`. 96 modelling tests pass; zero new pyright errors.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-24 08:25:08 +00:00
Jun-te Kim
9956df07ff Land an override on the EPC's part at its position when the label is absent 🟩
A Landlord Override's building_part is a positional index (0=main, 1=extension
1…, ADR-0004), but the gov-API EPC can label that slot differently (e.g. lodge
the 2nd part as 'other', not 'extension_1'). The previous fix skipped such
orphaned overrides, silently discarding the landlord's correction. Now the
override falls back onto the EPC's part at that position (via _resolve_part), so
the correction lands; only a position the EPC models no part at is skipped
(no geometry to model a wholly-absent part). Replaces the skip-only behaviour.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:09:11 +00:00
Jun-te Kim
539f661430 Skip a landlord override that targets a building part the EPC lacks 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:35:19 +00:00
Jun-te Kim
a3e2566378 landlord override data added 2026-06-20 12:57:54 +00:00
Khalim Conn-Kowlessar
fc7c4d2d3b fix(climate): compute EPC CO2/PE on the postcode demand cascade (SAP 10.2 Appendix U p.124)
The SAP/EI rating is computed on UK-average weather (Appendix U Tables
U1-U3 region 0) so ratings are nationally comparable, but Appendix U
paragraph 1 (PDF p.124) requires that "other calculations (such as for
energy use and costs on EPCs) are done using local weather. Weather data
for each postcode district are taken from the PCDB". `Sap10Calculator.
calculate` ran ONE cascade (UK-average) and fed it to SAP, CO2 AND primary
energy, so every cert's EPC-displayed CO2/PE were computed on the wrong
climate. Because most of England is warmer than the UK-average, this
systematically OVER-counted heating demand on the emissions/PE outputs.

The two cascades (`cert_to_inputs` rating, `cert_to_demand_inputs`
postcode) already existed; this wires the demand cascade into the
production entry point and grafts its CO2/PE onto the rating result (SAP
unchanged). The corpus gauge's longstanding +5% CO2/PE over-estimate was
mostly this climate bug, NOT (as previously diagnosed) per-cert mapper
fidelity:
  CO2 MAE 0.26 -> 0.12 t/yr  (bias +0.18 -> +0.04)
  PE  MAE 13.6 -> 3.8 kWh/m2 (bias +9.0  -> +0.24)
  SAP within-0.5 = 69.7% (rating cascade, unchanged)

Worksheet-validated to 1e-4 on simulated case 45 (heat-pump ground-floor
flat, postcode W6): the P960 prints the current dwelling twice — Block 1
on UK-average weather (SAP 60.5318, CO2 692.13) and Block 2 on postcode
weather (CO2 626.78, PE 6581.59). Both reproduce exactly. Added a tracked
case-45 Summary fixture + two-cascade cascade pin as a permanent guard,
and ratcheted the corpus CO2/PE ceilings to 0.13 / 4.2. The e2e Elmhurst
suite (Block-1 line refs) now pins the rating cascade directly; the two
Vaillant overlay snapshots refreshed to demand-cascade CO2/PE.

pyright not installed in this codespace (strict gate not run locally);
change is type-trivial (dataclasses.replace over SapResult).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 14:15:34 +00:00
Khalim Conn-Kowlessar
3580d059ec feat(modelling): drive measure scoping from the Scenario's exclusions
The measures a run considers should come from the Scenario, not a CLI flag.
The live scenario table persists exclusions only (no inclusions column), as a
Postgres text-array of exact MeasureType values.

- Scenario gains `exclusions: frozenset[MeasureType]` + `considered_measures()`
  (all measures minus the excluded ones, or None when none are excluded).
- ScenarioModel.to_domain parses the `{a,b,c}` exclusions array into
  MeasureTypes, raising on a token that is not an exact MeasureType value
  (no high-level category expansion), per the strict-enum convention.
- ModellingOrchestrator._plan_for derives the allowlist from the Scenario's
  exclusions, combined (intersection) with any explicit considered_measures
  override via the new `combine_considered_measures`.
- run_modelling_e2e sources the allowlist from the Scenario; --measures /
  --exclude-measures become optional overlays (e.g. the technical
  secondary_heating_removal exclusion the catalogue cannot yet stock).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 15:26:25 +00:00
Khalim Conn-Kowlessar
53d9f21f73 fix(modelling): offer ASHP when the catalogue has no ASHP row
The ASHP bundle is priced from the rate sheet (ADR-0025); the catalogue
row is read only for its material id, which is nullable end-to-end. The
live `material` catalogue has no `air_source_heat_pump` row, so
`products.get` raised `ValueError: no active product` and aborted every
ASHP-eligible property.

Add `ProductNotFound(ValueError)` + a concrete `ProductRepository
.get_optional`, raise the typed error from both repos, and have
`_ashp_option` look the row up optionally — a missing row now yields an
ASHP Option with `material_id=None` rather than crashing.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 14:55:41 +00:00
Khalim Conn-Kowlessar
c11eb46b8a fix(modelling): HHR overlay sets off-peak immersion type so HW Table 13 applies
The HHR-storage HeatingOverlay (ADR-0024) added an off-peak electric
immersion cylinder but never set `immersion_heating_type`, so the overlaid
cert left it None. The calculator then could not resolve `immersion_single`
for the SAP 10.2 Table 13 HW high-rate split and billed hot water 100% at
the off-peak low rate — £127.41 vs the relodged after-cert's £169.39,
overstating the overlay's SAP by +1.26 (CO2/PE matched, isolating it to the
HW cost path).

Add `immersion_heating_type` to HeatingOverlay, route it through
`_fold_heating` (it lives on `sap_heating`), and set it to 1 (single
off-peak immersion) on the HHR overlay to match the relodged reference.
Closes both `test_hhr_storage_overlay_reproduces_the_relodged_after_*`
cascade pins (electric-storage and no-system befores share the after).

Pre-existing failure (present before this branch's recent commits), outside
the handover regression gate. Full modelling suite 220 pass, pyright net-
zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-15 06:53:14 +00:00
Khalim Conn-Kowlessar
797b71cd13 test(modelling): secondary-heating-removal cascade validation (ADR-0028)
Two cascade tests on the worksheet-pinned 001431 build_epc() (the user's
before/after Summary PDFs trip the documented 001431 window-extraction bug, so
the repo's sanctioned 001431 baseline is used instead):
- electric-storage main (code 402) + secondary 691: removal reproduces the
  secondary-removed cert at delta 0 — RdSAP §A.2.2 re-forces a default secondary,
  matching the user's F35→F35 example;
- gas combi main (code 104) + secondary 691: removal strictly raises SAP
  (74.22→77.61) — the Table 11 fraction reallocates to the cheaper main.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 15:32:15 +00:00
Khalim Conn-Kowlessar
ae7959f57c feat(modelling): secondary-heating-removal generator + MeasureType (ADR-0028)
recommend_secondary_heating_removal offers one standalone Option that clears the
lodged secondary system. Eligibility is purely physical (offer iff
sap_heating.secondary_heating_type is set) — no effectiveness gate, since a
lodged secondary is a fixed emitter per RdSAP (portables are ignored), and the
electric-storage §A.2.2 no-op is the Optimiser's call (ADR-0028 decisions 1-2).
Priced at a flat per-dwelling decommission cost, not room-scaled.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 13:35:14 +00:00
Khalim Conn-Kowlessar
9b286e4a22 feat(modelling): SecondaryHeatingOverlay clears the lodged secondary (ADR-0028)
The first overlay surface that sets fields to *absent* rather than to a
target state: _fold_secondary_heating clears sap_heating.secondary_heating_type
+ secondary_fuel_type, so the calculator's Table 11 secondary-fraction split
(SAP 10.2 §9a) routes 100% of space heating to the main. On an electric-storage
main RdSAP §A.2.2 re-forces a default secondary, making removal a no-op there —
left to the Optimiser to de-select (ADR-0028 decisions 2-3).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 13:13:20 +00:00
Khalim Conn-Kowlessar
6ce6e89de1 feat(modelling): gate boiler upgrade on the existing boiler's efficiency
Don't offer a like-for-like gas boiler swap to a dwelling whose existing gas
boiler is already at least as efficient as the new condensing boiler (SAP 10.2
Table 4b codes 102/104 = 84% winter) — it gains nothing, and the dwelling gets
the tune-up (cylinder + controls) instead. `_already_condensing` compares the
existing code's Table 4b winter efficiency to 84%; a non-Table-4b code (solid
fuel) has no comparable efficiency and is never treated as already-condensing.

The gate is GAS-ONLY: a non-gas boiler → gas is a fuel switch whose value (cost
/ carbon) is not captured by winter efficiency, so oil/LPG/coal → gas is never
suppressed on efficiency grounds (only gated on the mains-gas connection).

This correctly demotes the gas-with-cylinder example (cert lodges code 114
"Regular, condensing", 84% winter) to a tune-up case — confirming that 114→102
is ~0 boiler-efficiency gain in both our calc and Elmhurst (both Table 4b 84%);
Elmhurst's uplift there came from the cylinder + flue, not the boiler. The
boiler-with-cylinder overlay stays validated by the lpg pin (code 115, non-
condensing + cylinder) and by recasting the 114 fixtures' code to a pre-1998
non-condensing boiler (110) in the boiler tests — the overlay overwrites the
code to 102 regardless, so only eligibility changes, not the delta-0 result.
New tests: an already-condensing gas boiler yields no boiler upgrade (but a
tune-up); an oil condensing boiler is not gated (the fuel switch survives).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:15:58 +00:00
Khalim Conn-Kowlessar
ae7e6a0c42 feat(modelling): composite per-dwelling boiler + tune-up costing (ADR-0027)
Replace the flat placeholder scalars (boiler £3000; tune-up £500/£900) with a
per-dwelling composite cost, mirroring the ASHP architecture (ADR-0025): a
`HeatingRates` table (data, `heating_rates.json`), typed `BoilerCostInputs` /
`TuneUpCostInputs`, pure `Products.boiler_bundle_cost` / `tune_up_cost`, and
modelling-layer interpreters that read the dwelling into those inputs.

The cost mirrors the Simulation Overlay component-for-component, sharing the
controls + cylinder pricing across both options:

- tune-up (standard) = standard controls + cylinder fixes
- tune-up (zone)     = zone controls + cylinder fixes
- boiler upgrade     = £3200 all-in + standard controls (only when the upgrade
  fired a controls change) + cylinder fixes

Standard controls are priced INCREMENTALLY — only the parts missing to reach
SAP 2106 (programmer £120 / room thermostat £150 / TRV £35×radiators), read
from a Table 4e Group-1 feature map so a dwelling that already has a room
thermostat + TRVs is only charged the programmer. Zone controls are a full
smart kit (hub £205 + smart TRV £50×radiators) — the smart TRV is itself the
room sensor, so there is no separate per-room sensor line. Cylinder fixes:
jacket £50 (when under-insulated) + thermostat £150 (when absent). The boiler
is a like-for-like wet swap (no radiators/flue/pipework — eligibility already
requires an existing wet boiler), so those dead-code extras are not modelled.

Figures are research-validated 2025/26 UK installed costs (legacy Costs.py
lineage); fully-loaded totals with one contingency on top (Model B, not the
legacy VAT/preliminaries engine). Contingency: boiler 0.26; tune-ups 0.10
(was a 0.15 placeholder). ADR-0027 records the design; CONTEXT.md's Heating
Eligibility entry updated to cover the partial boiler/tune-up family + composed
cost. Products cost pins (delta<=1e-9) + interpreter tests + generator
composite-cost assertions.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 19:41:06 +00:00
Khalim Conn-Kowlessar
07f534ee11 feat(modelling): system tune-up options (standard + zone controls)
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:

- system_tune_up        — standard controls (programmer + room thermostat +
  TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned  — time-and-temperature zone control (code 2110, type 3):
  more SAP uplift for more cost

Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.

Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).

Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 10:20:46 +00:00
Khalim Conn-Kowlessar
2413bc87da feat(modelling): solid-fuel(coal)->gas boiler upgrade + boiler_flue_type end-state
Pin the coal-boiler-with-cylinder upgrade and add the `boiler_flue_type`
end-state field. A solid-fuel (coal) boiler (fuel 11, SAP code 153) on a
mains-gas street converts to a gas condensing boiler (fuel 11->26, code 102) —
the non-gas->gas path for a solid-fuel system, eligible because code 153 is in
the wet-boiler solid-fuel range 151-161 and mains gas is present.

New `boiler_flue_type` HeatingOverlay field, routed to main_heating_details[0]
and set to 2 (room-sealed/balanced) on both boiler shapes: every relodged after
lodges flue type 2, but coal's before lodged none. The field is SAP-inert (the
cascade score is unchanged by it), so it is written purely for end-state
fidelity — the overlay now represents the installed condensing boiler's flue.
Validated via the overlay-equality unit tests.

The coal after predates the user-locked "always add a cylinder thermostat when
absent" rule, so it stale-lodged thermostat 'N'; the pin corrects it to the
rule's end-state 'Y' in-test (the gas with-cylinder after got the same
correction by re-lodging). The cylinder is already 80 mm insulated, so the
jacket is skipped and only the thermostat is added; controls (2106) are
unchanged. Cascade-pinned delta 0 (SAP/CO2/PE).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:27:07 +00:00
Khalim Conn-Kowlessar
7bc9797a26 test(modelling): pin non-gas->gas + already-insulated-cylinder boiler upgrades
Two more boiler-upgrade cascade pins, validating the existing generator across
fuels and cylinder states (no source change):

- oil combi: an oil boiler (fuel 28, code 130) on a mains-gas street converts to
  a gas condensing combi (fuel 28->26, code 104). Proves the non-gas -> gas
  conversion gated on a mains-gas connection (ADR-0024 revised).
- already-insulated cylinder: a gas boiler heating a pre-jacketed cylinder
  (type 2 / 80 mm, no thermostat) gets a new boiler + a thermostat, with the
  jacket NOT re-applied. Proves the cylinder path's skip-jacket branch against a
  real cert. (Sourced from an LPG re-lodgement whose fuel the Summary mapper
  reads as mains gas 26 — a separate LPG fuel-mapping gap, noted in the test.)

Both pin delta 0 (SAP/CO2/PE) against the relodged after.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:37:32 +00:00
Khalim Conn-Kowlessar
63dd69ff8b feat(modelling): gas combi boiler upgrade + controls-when-inadequate
Extend the gas-boiler-upgrade Option to combi (no-cylinder) dwellings and add
the controls upgrade shared by both boiler shapes. A dwelling has a cylinder or
it does not, so the one `gas_boiler_upgrade` Option is shaped per dwelling:

- no cylinder -> a gas condensing combi (Table 4b code 104), no cylinder fields
  touched;
- a cylinder  -> a regular boiler (code 102) heating it, with the conditional
  cylinder jacket/thermostat (slice 1).

Controls: bring an inadequate boiler control up to full programmer + room
thermostat + TRVs (SAP 10.2 Table 4e Group 1 code 2106). "Inadequate" = the
Group-1 codes with NO room thermostat (2101, 2102, 2107, 2108, 2109, 2111) —
these lack boiler interlock (Table 4c(2) / footnote c) p.171), so adding a room
thermostat genuinely improves SAP. Room-thermostatted (2103/2104/2105/2106/2113)
or better zone controls (2110/2112) are left unchanged — never downgraded, so
no phantom uplift. The with-cylinder cert (control 2106) is therefore untouched
and its pin still holds at delta 0.

Validated by the combi before/after re-lodgement (cert 001431, gas boiler
upgrade - no cylinder): control 2111 "TRVs and bypass" -> 2106, fan flue
False->True, SAP code 112 -> 104. Cascade-pinned delta 0 (SAP/CO2/PE). Removed
the slice-1 placeholder test asserting no boiler Option fires without a cylinder
(the combi Option now correctly fires there).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:28:00 +00:00
Khalim Conn-Kowlessar
31c74ab500 feat(modelling): gas-boiler-upgrade-with-cylinder option in the heating rec
Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.

The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:

- Target is always a gas condensing boiler, not fuel-preserving: every after
  lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
  mains-gas connection; electric boilers are left alone (electrification is the
  upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
  151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
  + cylinder). The calculator derives the condensing seasonal efficiency from
  the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
  `fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
  the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
  field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
  the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
  cylinder is below 80 mm (never downgrading a better one). Both are conditional
  per-dwelling components, not a frozen overlay.

Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.

Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:16:46 +00:00
Khalim Conn-Kowlessar
7942a8101a feat(modelling): considered_measures allowlist on the orchestrator
Add domain/modelling/considered_measures.py::restrict_to_considered_measures —
the pure allowlist that limits a run to a chosen set of MeasureType (mirroring
the legacy engine's `inclusions`). It filters at the Option level, so a
multi-option Recommendation (e.g. Heating & Hot Water competing HHRSH against
an ASHP bundle) is kept with only its allowed Options; a Recommendation left
with none is dropped. None = consider everything (unrestricted default).

Thread `considered_measures: frozenset[MeasureType] | None` through
ModellingOrchestrator.run -> _plan_for -> _scored_candidate_groups /
_candidate_recommendations (applies the filter) and _measure_dependencies
(suppresses a forced dependency whose required measure is outside the
allowlist, so a restricted run forces nothing it is not considering). The
local-run seam (harness.console.run_modelling) gains the same param.

The Optimiser still freely chooses among survivors — including none. Tests:
the pure filter (3 cases) + an orchestrator-seam test proving a
{solar_pv}-restricted run yields only solar_pv options. 257 pass + 3 xfail;
pyright clean.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 20:32:11 +00:00
Khalim Conn-Kowlessar
9ef97be958 refactor(modelling): type measure_type fields as MeasureType
Tighten the recommendation/plan vocabulary off generic str:
MeasureOption.measure_type and PlanMeasure.measure_type are now MeasureType
(also _GlazingTarget.measure_type, MeasureDependency.triggers ->
frozenset[MeasureType], and the optimiser's chosen/required-type locals).
Because MeasureType is a StrEnum the change is transparent to persistence
(the `recommendation` varchar column), the optimiser group-by key, and every
`== "solar_pv"`-style comparison — so pyright now enforces the enum at every
construction site with no runtime behaviour change.

The catalogue boundary stays str: ProductRepository.get(measure_type: str)
and Product.measure_type are unchanged (they map arbitrary DB/JSON rows), so
the fake product repos in tests need no edit. Test construction helpers coerce
their str arg via MeasureType(...); direct constructions use members.

Suite green: tests/domain/modelling + orchestration + harness 253 pass + 3
xfail; pyright clean on production + tests (pre-existing moto + property-
override-rowcount baselines untouched).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 20:13:31 +00:00
Khalim Conn-Kowlessar
d58ac60d29 feat(modelling): MeasureType StrEnum as the canonical measure vocabulary
Introduce domain/modelling/measure_type.py — a StrEnum with one member per
modelled measure (the 15 the generators emit). A StrEnum so each member *is*
its string value: it persists straight into the `recommendation` varchar
column, is the optimiser's group-by key, and compares equal to the catalogue /
EPC strings — so it replaces the per-generator string constants with no
persistence or optimiser change.

Repoint every generator's measure-type constant/literal to a MeasureType
member (wall, solid_wall, roof, floor, glazing, lighting, ventilation,
heating, solar). Field annotations stay `str` for now; tightening them to
MeasureType is the next slice.

This is the enum the historical engine deferred (engine.py:970
"TODO - formalise property measure types into an enum") and the vocabulary the
forthcoming `considered_measures` allowlist will speak (mirroring the legacy
`inclusions`).

Suite green: tests/domain/modelling + orchestration + harness 253 pass + 3
xfail; pyright clean on the enum + generators.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 19:54:04 +00:00
Khalim Conn-Kowlessar
24492aa4ba Merge origin/main into feature/bill-derivation (calculator + mapper fixes)
Pulls in 42 commits of calculator/mapper accuracy fixes from the per-cert
mapper-validation and floor/roof/heating fronts.

Conflict resolutions:
- mapper `_is_elmhurst_roof_window`: main dropped the branch's "wall location →
  vertical" guard (it broke cert 000516's rooflight), but that re-broke cert
  001431's two External-wall U>3.0 windows (which must stay vertical). The two
  certs lodge a BYTE-IDENTICAL §11 row, so neither location nor U separates
  them — the real discriminator is the room-in-roof context. Replaced the
  unconditional U>3.0 backstop with one gated on the BP having a room-in-roof
  (`_elmhurst_bp_has_room_in_roof`): 000516's Main BP has a "Room in roof type
  1" (→ rooflight), 001431's does not (→ vertical). Validated against BOTH —
  full Elmhurst worksheet suite 1038 pass + the 001431 window-extraction pin.
- property_postgres_repository: kept main's `ids_by_uprn` method + the branch's
  `_restrictions_of` helper.
- sap_fuel.py: the branch relocated it to domain/billing/ (already carrying
  main's to_table_32_code normalization), so kept the old path deleted.

Fallout from main's fabric fixes (validated by the boiler-3 real-cert pin which
still reproduces at delta 0):
- re-pinned the boiler-1 + boiler-instant-hw ASHP snapshot scores;
- main's §14.2 gas-boiler main-fuel derivation resolved the BGB/102 baseline
  gap, so `test_gas_boiler_instant_hw_before_baselines` is now a passing test
  (was an xfail tripwire).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 13:12:21 +00:00
Khalim Conn-Kowlessar
2f3b1dbd3f test(modelling): Solar PV Elmhurst cascade pins + battery tripwire
Slice 9 of the Solar PV Recommendation Generator (ADR-0026). Pins the
overlay→calculator PV cascade against Elmhurst's before/after re-lodgements of
cert 001431, across the orientation/pitch/overshading config space (the certs
lodge synthetic 1.00 kWp test vectors):
 - SE/SW, shaded (overshading 3/2), pitch 30°/45°
 - E/W, unshaded, pitch 60°/45°
 - NW/N, unshaded, pitch 60°/45° (the low-yield orientations)
Each hand-built SolarOverlay reproduces the relodged after at abs ≤ 1e-4 on
SAP / CO2 / primary energy.

Battery tripwire (per user): the "with battery" cert lodges a §19 5 kWh battery
the current extractor does NOT parse, so it scores identically to its
no-battery twin — the no-battery overlay reproduces it today, and the pin will
fail (alerting us to switch to the with-battery overlay) once the extractor
parses the battery. A companion test pins that the calculator already models
the 5 kWh battery (it raises SAP), so the fix target is established.

All five certs share an EES 'WGK' / SAP-code-502 main-heating lodgement the
mapper doesn't yet derive a fuel for; the pins patch the shared fuel (mains gas
26) identically on before+after to isolate the PV delta (the solar overlay
never touches heating), and `test_solar_before_baselines` xfails as the
forcing-function tripwire for that separate mapper-front gap.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 12:42:24 +00:00
Khalim Conn-Kowlessar
09cb8ceb9d feat(modelling): recommend_solar — eligibility + competing array Options
Slice 6 of the Solar PV Recommendation Generator (ADR-0026). `recommend_solar`
emits one "Solar PV" Recommendation of up to five conservatively-sized configs
× {no battery, battery} = ≤10 competing Options (a free Optimiser candidate).
Each Option folds a SolarOverlay built from the chosen config: one
PhotovoltaicArray per non-north segment (peak_power = panels × panelCapacityW /
1000; orientation/pitch from geometry; generation-calibrated overshading),
is_dwelling_export_capable set True absolutely, a diverter when the dwelling
has a cylinder (None for a combi), a 5 kWh battery for the battery variant, and
the per-config composite cost from Products.solar_bundle_cost.

Eligibility = house/bungalow ∧ not listed/heritage (blocks_internal, the same
gate as ASHP — a conservation area does NOT block PV) ∧ no existing PV ∧ a
feasible SolarPotential. Flats and existing-PV top-up are deferred.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 12:14:24 +00:00
Khalim Conn-Kowlessar
46bca47365 feat(modelling): Products.solar_bundle_cost + committed solar rate sheet
Slice 7 of the Solar PV Recommendation Generator (ADR-0026). Adds the
composite per-dwelling Solar PV cost on the Products collection (ADR-0025
pattern): pv_system(kWp band, nearest of the ECOPV06-13 EA bands 1.0→4.5 kWp,
floor/cap at the ends) + scaffolding(£900 first elevation + £450 each
additional, default 2) + enabling base (EICR £150 + DNO £50 + 2-way consumer
unit £330) + [diverter £980 if cylinder] + [battery if the with-battery
variant] → Cost(total, contingency_rate 0.15).

Rates are data in the committed solar_rates.json (Southern Housing "SOLAR PV &
BATTERY" EA column), loaded via SolarRates.from_json/.default and injectable.
The £2,000 / 5 kWh battery is NOT on the rate sheet — a flagged estimate
(battery_estimate=true), confirmed with the user to stand in until a DB rate.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 12:10:27 +00:00
Khalim Conn-Kowlessar
9dddfa00c8 feat(modelling): SolarOverlay + _fold_solar (sixth overlay surface)
Slice 5 of the Solar PV Recommendation Generator (ADR-0026). Adds the flat
`SolarOverlay` and `_fold_solar`, the sixth Simulation Overlay surface: like
the ventilation/lighting overlays it targets no building part and folds its
fields onto `sap_energy_source` (home of the SAP Appendix M PV inputs) —
photovoltaic_arrays (absolute target, one PhotovoltaicArray per non-north
segment, replacing the dwelling's existing arrays), pv_diverter_present,
pv_connection, is_dwelling_export_capable (set True absolutely), pv_batteries.
Omitted fields leave the baseline unchanged (combi → no diverter); the
baseline is never mutated.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 10:10:15 +00:00
Khalim Conn-Kowlessar
c03f4ff123 feat(modelling): conservative PV config selection (5-config spread)
Slice 4 of the Solar PV Recommendation Generator (ADR-0026).
`select_conservative_configs` turns Google's full solarPanelConfigs ladder
into up to five competing array configs for the Optimiser: drop north-facing
planes (within 30° of due north, wrap-aware), cap usable panels at ~70% of
maxArrayPanelsCount (imagery misses obstructions; MCS edge setback), collapse
rungs that trim to the same usable size keeping the higher-generation layout,
then sample five spanning min→max by expected generation. Returns () when
nothing usable remains.

Real London example → 5 rungs at 4/12/19/26/34 panels (all ≤34.3 = 70% of
49); synthetic cases pin the north-drop and the 70% cap.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 10:02:15 +00:00
Khalim Conn-Kowlessar
82c3422788 feat(modelling): generation-calibrated PV overshading derivation
Slice 3 of the Solar PV Recommendation Generator (ADR-0026). Per roof segment,
back-solve the effective overshading factor ZPV from Google's expected
generation against SAP's own unshaded annual output:

    ZPV = (yearlyEnergyDcKwh × 0.955) / (0.8 × kWp × S)

reusing the calculator's Appendix U3.3 annual solar radiation S via a new
public seam `pv_annual_solar_radiation_kwh_per_m2`. Dividing Google's
generation by SAP's S cancels orientation/tilt and isolates shading; the
result snaps to the RdSAP bucket {1:1.0, 2:0.8, 3:0.5, 4:0.35} via the
ADR-0026 midpoint cutpoints (≥0.90→1, 0.65–0.90→2, 0.425–0.65→3, <0.425→4;
ZPV>1→1). The real London example's planes all back-solve to ZPV>1 → code 1.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 09:59:48 +00:00
Khalim Conn-Kowlessar
f31d5bcff9 feat(modelling): typed SolarPotential projection over Google buildingInsights
Slice 2 of the Solar PV Recommendation Generator (ADR-0026). Adds the
strictly-typed `SolarPotential` domain projection over the raw Google Solar
`buildingInsights` JSON that Ingestion persists (SolarRepository): the
`solarPanelConfigs` ladder, each rung broken into its roof segments with
Google's continuous azimuth/tilt mapped to the SAP octant
(`azimuth_to_sap_octant`, 0°=N clockwise → 1=N..8=NW, matching the
calculator's ORIENTATION_BY_SAP10_CODE) and RdSAP §11.1 pitch code
(`pitch_to_sap_code`, snap to {0→1,30→2,45→3,60→4,90→5}).

Pinned against the real London buildingInsights example (mirrored into
fixtures from the user-provided RTF): 400 W panels, maxArrayPanelsCount 49,
46-rung ladder, per-segment SE/NW/NE/SW octants at ~32° → pitch code 2.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 09:55:55 +00:00
Khalim Conn-Kowlessar
11fb82b485 test(modelling): pin boiler-1/2 ASHP to the Vaillant overlay snapshot
The boiler-1 and boiler-2 after-certs predate the Vaillant product swap (they
lodge the old aroTHERM index 101413), so rather than wait on regenerated certs
these now snapshot the Vaillant overlay's own output on the before (SAP/CO2/PE
at 1e-4), taken as correct because the same overlay reproduces the corrected
Vaillant cert at delta 0 in the boiler-3 (system-boiler) pin. Drops the xfail
markers and the two stale, now-unreferenced after-cert fixtures.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-07 20:16:58 +00:00
Khalim Conn-Kowlessar
dd92ba5972 refactor(modelling): load ASHP rates from a committed costs file
Slice 10 of ADR-0025 costing. The Southern Housing rate table moves from code
constants into ashp_rates.json (structured rows the flat scalar catalogue can't
hold), loaded via AshpRates.from_json. Products takes an injected AshpRates
(default: the committed sheet), so rates are now data -- tunable (e.g.
reuse_distribution_fraction) without a code change, and ready for ETL/DB-supplied
rates later. Behaviour-preserving: the 6 pinned cost tests still hold against the
default, plus a new test proving injected rates drive the total.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 23:19:53 +00:00
Khalim Conn-Kowlessar
32f1916619 test(modelling): finalize Vaillant ASHP swap on the cascade pins
The representative heat pump is now the Vaillant aroTHERM plus 5 kW (index
110257, committed with the generator). boiler-3's after-cert is re-sourced from
the corrected Vaillant relodgement and its cascade pin passes at delta 0
(SAP 63.85 -> 72.30). boiler-1 and boiler-2(instant-HW) pins are xfail pending
their own corrected Vaillant after-certs (_ASHP_PRODUCT_REPIN_REASON).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 21:33:09 +00:00
Khalim Conn-Kowlessar
f06a048a6f feat(modelling): ASHP option carries the composite per-dwelling cost
Slice 9 of ADR-0025 costing. _ashp_option now prices via Products.ashp_bundle_
cost(ashp_cost_inputs(epc)) instead of the flat catalogue scalar; the catalogue
row is still read for its material_id. Pinned on boiler-3: gas reuse dwelling
composes to 15600.60 (decommission 720 + pump 9720 + cylinder 2382.60 + reuse
distribution 2778) with 25% contingency.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 21:17:06 +00:00
Khalim Conn-Kowlessar
6f136a8d6a feat(modelling): classify ASHP existing system by fuel code
Slice 8 of ADR-0025 costing. _existing_system keys on the heating fuel code,
not the mains_gas flag -- the 001431 electric fixtures all lodge mains_gas=True
(gas available at the property) while heating electrically (fuel 30), which the
flag-based check misread as gas (and would have wrongly reused a non-existent
wet system). Electric/gas/oil/LPG map to their categories; empty details ->
NONE; unrecognised -> OTHER (gas-line fallback).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 21:10:45 +00:00
Khalim Conn-Kowlessar
f182f36802 feat(modelling): ashp_cost_inputs reads a dwelling into AshpCostInputs
Slice 7 of ADR-0025 costing: the modelling-layer interpretation half of the
split. ashp_cost_inputs derives existing system (mains_gas/fuel/SAP-code),
size band (floor area <= 75 m2), design heat loss (floor_area x 0.05 -- the
chosen proxy over HLC, ADR updated), radiator count (habitable + 3, floor-area
fallback) and reusable-wet-system flag. Catalogue math (Products) stays
EPC-free. ADR-0025 updated to record the floor-area pump-sizing choice.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:59:27 +00:00
Khalim Conn-Kowlessar
c7acf43b52 test(modelling): pin ASHP radiator-count clamp to table bounds
Slice 6 of ADR-0025 costing. Characterises the distribution clamp built in the
tracer: a radiator proxy below 4 prices as the 4-rad band, above 12 as the
12-rad band, in-range exact.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:44:57 +00:00
Khalim Conn-Kowlessar
fd9e020b09 test(modelling): pin ASHP heat-pump band round-up at the edges
Slice 5 of ADR-0025 costing. Characterises the pump-band selection built in
the tracer: a design heat loss is rounded UP to the smallest covering band
{5,8,11,15,16+} kW, and loads above the largest band take the top rate. Edge
pins (5.0/5.01/8.0/8.01/11.0/15.0/15.01/25.0) lock the boundaries.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:44:19 +00:00
Khalim Conn-Kowlessar
9860f06864 feat(modelling): ASHP decommission fallbacks for off-sheet systems
Slice 4 of ADR-0025 costing. ASHP is offered to any house regardless of fuel,
so _decommission now prices a fallback instead of raising: no system -> 0,
electric room/panel heaters -> electric-storage line, anything else -> gas
line (representative default). Never blocks ASHP eligibility.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:42:14 +00:00
Khalim Conn-Kowlessar
22612a19eb feat(modelling): ASHP reuse case prices flush + half distribution
Slice 3 of ADR-0025 costing. When the dwelling has a reusable wet system,
_distribution charges a power-flush (168) plus _REUSE_DISTRIBUTION_FRACTION
(0.5) of the full radiator band -- a documented stand-in for partial radiator
upsizing at ASHP flow temps, the headline uncertainty in the model. Without a
wet system the full new distribution is priced.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:41:06 +00:00
Khalim Conn-Kowlessar
cf7c2e017d feat(modelling): ASHP decommission cost by existing system
Slice 2 of ADR-0025 costing. _decommission maps the existing system to its
Southern Housing line: gas/oil flat 720, LPG 960 (tank+fuel removal),
electric-storage 570/840 by property-size band. Unmapped systems raise for
now -- the no-system/electric-other/other fallbacks land in the next slice.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:36:12 +00:00
Khalim Conn-Kowlessar
d23b84209d feat(modelling): Products.ashp_bundle_cost composite ASHP cost (tracer)
First slice of the per-dwelling ASHP bundle costing (ADR-0025). Products is
the rich catalogue collection over Product, owning the catalogue math: given
a typed AshpCostInputs it sums the applicable Southern Housing rate lines
(decommission + heat-pump band + fixed cylinder + full wet distribution) into
a Cost with the separate 25% ASHP contingency. Pure -- no EpcPropertyData or
calculator. Pinned exact (1e-9) against the real rate sheet. Reuse branch,
decommission variants, fallbacks, band edges and radiator clamp follow.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:32:54 +00:00
Khalim Conn-Kowlessar
d9c7638b3c test(modelling): ASHP from a system gas boiler with an existing cylinder
Pins the cylinder-OVERWRITE path the earlier ASHP pins did not exercise:
boiler-1/boiler-2 added a cylinder where none existed, whereas boiler-3's
before is a mains-gas regular boiler (SAP code 101) that already heats its
own cylinder (size 2 / insulation type 2 / 80 mm). The fixed _ASHP_OVERLAY
overwrites it to the heat-pump cylinder (size 4 / insulation type 1 / 50 mm)
and switches the dwelling off mains gas (fuel 26->30, code 101->index 101413
+ category 4). The existing overlay reproduces the re-lodged after at delta 0
on SAP / CO2 / primary energy -- no overlay change needed; immersion_heating_
type is None in both, so that field (the electric-with-cylinder case) is
untouched here.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 18:20:58 +00:00
Khalim Conn-Kowlessar
ec76acc3d8 test(modelling): ASHP pin from a gas boiler with instantaneous HW + fuel tripwire
Second ASHP before/after (boiler 2): a gas boiler whose hot water is electric/
instantaneous (water-heating SAP code 909, no cylinder). The cascade pin passes
at 1e-4, exercising the overlay's water_heating_code reset 909 -> 901 that the
boiler-1 pin (already 901) did not. (After lodges control 2209 vs the overlay's
2210 — SAP-equivalent zone controls.)

Adds an xfail(strict) tripwire test_gas_boiler_instant_hw_before_baselines: the
raw before is not scorable on its own because the mapper maps the 'BGB' gas-
boiler EES code to an empty main_fuel_type (boiler-1's 'RGE' resolves to 26),
so Sap10Calculator raises MissingMainFuelType. Harmless to the pin (the overlay
overwrites fuel -> 30); flips green when the mapper derives mains gas from the
gas-boiler SAP code (separate mapper-front fix). ADR-0024.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 17:40:25 +00:00
Khalim Conn-Kowlessar
9f17a27766 feat(modelling): ASHP overlay resets water_heating_code to the HP end-state
The ASHP bundle is a fixed whole-system end-state (confirmed: always the same
contractor cylinder), so the hot-water arrangement is fixed too. The overlay now
sets water_heating_code=901 ("from main system") absolutely, so a combi (909/611)
or electric (903/908) before is reset to HW-from-the-heat-pump — previously the
overlay relied on the before already lodging 901 (true for boiler-1, not in
general). No-op for the boiler-1 pin (stays 1e-4). Cascade pins for combi /
electric-with-cylinder befores await example certs. ADR-0024.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 17:18:58 +00:00