Commit graph

362 commits

Author SHA1 Message Date
Khalim Conn-Kowlessar
39ae2cf0c2 fix(water-heating): split whc-903 immersion HW CO2/PE on off-peak tariffs
SAP 10.2 Table 12d/12e: electric water heating on a 7-/10-hour tariff bills
CO2/PE at the high-rate code (32/34) and low-rate code (31/33), kWh-weighted
by the Table 13 high-rate fraction. The cost path already applied this split;
the CO2/PE factors did not — they used the flat annual Table 12 figure
(0.136 CO2 / 1.501 PE) for ALL dual-rate electric HW.

That flat-annual behaviour (slice S0380.163) was validated only against
HW-from-main "low-rate cost" certs (100% low, no high-rate split). It is NOT
how Elmhurst bills a whc-903 ELECTRIC IMMERSION: the hand-built case-50
worksheet (000565 + dual immersion, 7-hour) splits HW CO2/PE into "high rate
cost" (CO2 0.1475 / PE 1.5514) + "low rate cost" (CO2 0.1238 / PE 1.4429)
weighted by the Table 13 fraction 0.1009. So flat-0.136 for immersion HW was
a spec gap on our side, not an Elmhurst divergence.

Fix: `_electric_immersion_hw_high_rate_fraction` threads the Table 13 fraction
(scoped to whc-903, 7-/10-hour, cylinder data present) into the HW CO2 + PE
factor helpers, which then blend the Table 12d/12e high/low codes. The flat
rule is unchanged for HW-from-main and 18-/24-hour (no Table 12d split), so
the S0380.163 41-variant cases and the existing pin are untouched.

Case 50: rating CO2 2413.48 -> 2397.1237 = Elmhurst EXACT; demand CO2 2007.1384
EXACT; demand PE +111 -> +32.5 residual (within corpus PE noise). Corpus
unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4 (62 whc-903 off-peak certs;
aggregate gauges hold). SAP unaffected (cost-based).

Pin: test_whc903_immersion_hw_co2_pe_factors_split_high_low_on_off_peak; doc
updated in SAP_CALCULATOR.md §8.1.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:05:21 +00:00
Khalim Conn-Kowlessar
cd5113abf2 fix(tariff): include MVHR fan electricity in the off-peak Grid 2 fan split
SAP 10.2 Table 12a Grid 2 (PDF p.191) bills "Fans for mechanical ventilation
systems" at 0.71 (7-hour) / 0.58 (10-hour), distinct from "All other uses"
(0.90 / 0.80) which covers circulation pumps, flue fans and the solar HW pump.

The cost-split mech-vent kWh (`mev_kwh_for_cost_split`) only summed the
decentralised-MEV (230b) fans, not the (230a) MVHR fan electricity — even
though the total pumps/fans bucket adds both. So an MVHR dwelling on an
off-peak tariff billed its fan electricity at the 0.90/0.80 "all other uses"
rate instead of 0.71/0.58. The comment already said "MEV/MVHR-fan portion";
only the MEV term was wired when MVHR landed. Fixed to mirror both
mechanical-ventilation fan terms summed into the total.

Worksheet-proven on simulated case 50 (000565 semi + MVHR Vent Axia + dual
electric immersion, Unknown meter -> 7-hour via the §12 dual-immersion
trigger): the fan bucket (315.64 kWh, 100% MVHR per worksheet line 230a) was
billing at 14.311 p/kWh (0.90) vs Elmhurst's 12.451 p/kWh (0.71) — +£5.87/yr,
-0.23 SAP. After the fix our existing-dwelling rating reconciles to Elmhurst
EXACTLY: SAP value 38.8426 (=Elmhurst 38.8426 -> 39), total cost £1317.0116
(=Elmhurst £1317.0116 to the penny).

Same `mev_kwh_for_cost_split` feeds the CO2 + PE cascades, so all three split
consistently. 0 corpus impact (all 3 corpus MVHR certs are standard tariff);
gauge unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4.

Pin: test_mvhr_fan_electricity_bills_at_grid2_fan_fraction_on_off_peak.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 22:16:58 +00:00
Khalim Conn-Kowlessar
eea5d3a5a8 fix(tariff): map electric boilers 191/193-196 to their Table 12a Grid 1 rows
SAP 10.2 Table 4a electric boilers (PDF p.170) split across three distinct
Table 12a Grid 1 SH rows (PDF p.191), not one "direct-acting" family as the
stale TODO in `_table_12a_system_for_main` implied:

  - 191 Direct-acting electric boiler   -> "Direct-acting electric boiler (a)"
    row: 7-hour 0.90, 10-hour 0.50 (NOT the 1.00/0.50 "Other direct-acting
    electric heating" room-heater row).
  - 193/194/195/196 Electric dry core / water storage boiler -> "Electric dry
    core or water storage boiler" row: 7-hour 0.00 (charged wholly off-peak =
    100% low rate, identical to the None fallback).
  - 192 Electric CPSU -> Appendix F; left falling through to None (off-peak
    low) until the Appendix-F high-rate cascade is implemented.

The enum + fractions already existed in table_12a.py; only the code->enum
mapping was missing. Resolves the TODO and pins the spec-correct 0.00 for the
storage boilers so 195 can't be mis-"fixed" up to a direct-acting fraction.

Forward guard, 0 corpus impact: storage boilers already billed 100% low via
the None fallback, and all corpus 191 certs are on standard tariff (Table 12a
off-peak split never fires). Corpus gauge unchanged 73.3% / MAE 0.774.

Pin: test_electric_boilers_191_195_map_to_distinct_table_12a_grid1_rows.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 21:48:59 +00:00
Khalim Conn-Kowlessar
9694650abe fix(water-heating): derive combi keep-hot from the PCDB record, default no-keep-hot
SAP 10.2 Table 3a (PDF p.160) additional combi loss (61)m. Two coupled
defects, both surfaced by simulated case 49 (000565 + gas combi, U985
"Combi keep hot type = None") sitting at SAP 71.43 vs the worksheet's 72:

1. The cascade defaulted EVERY non-PCDB combi to the flat keep-hot
   time-clock row (600 × n/365). A combi WITHOUT a keep-hot facility uses
   row 1 (600 × fu × n/365, fu = V_d/100 when daily HW < 100 L/day) —
   over-counting (61)m for the no-keep-hot cohort. `water_heating_from_
   cert` now defaults to the "without keep-hot" row.

2. `pcdb_combi_loss_override` returned None for keep_hot_facility=1/
   timer=1, leaning on the OLD flat-600 default. So flipping the default
   silently turned 190 corpus PCDB keep-hot-time-clock combis into
   no-keep-hot. Fixed to return the flat keep-hot row EXPLICITLY.

Key insight (the Summary is the input echo; the U985 keep-hot line is a
computed OUTPUT, so it must be derivable): keep-hot rides on the PCDB
boiler record (Table 105 keep_hot_facility/timer), resolved by
`pcdb_combi_loss_override`. A generic SAP-code combi with no PCDB record
(case 49, PCDF ref 0) has no keep-hot by construction → row 1. So the
default is not a guess — it is the spec-correct value for non-PCDB combis.

Worksheet-proven: case 49 → cost £726.696, SAP 72 — matching the
accredited worksheet to the digit (continuous 71.6945 = the worksheet's
own 71.6945). 000516 (keep-hot None) also exact (£860.716, SAP 63);
000490 (PCDB 10328, keep_hot_facility=1/timer=1) keeps its flat-600 via
the PCDB path. Masked until now because every prior combi-loss worksheet
fixture was keep-hot (000490/000474/000480 time-clock) or had V_d >= 100
every month (001431, rows coincide); case 49 is the first no-keep-hot one.

Corpus within-0.5 72.7% -> 73.3%, MAE 0.781 -> 0.774, PE 3.5 -> 3.4;
ratcheted _MAX_SAP_MAE 0.785 -> 0.775, _MAX_PE_PER_M2_MAE 3.6 -> 3.5.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 21:22:02 +00:00
Khalim Conn-Kowlessar
b7455aabe5 fix(ventilation): MVHR takes lodged 0 intermittent fans, not the Table 5 default
Extends the dMEV intermittent-fan fix (4db05e84) to MVHR. A balanced
whole-house MVHR system IS the dwelling's ventilation, so the lodged (7a)
intermittent-extract-fan count is explicit — a lodged 0 means 0, not the
RdSAP 10 Table 5 age-band "unknown" default. The cascade was substituting
the default (here 20 m³/h) into worksheet line (8) openings, inflating
(16/18) infiltration → (21) → (22b) → (25) effective ach → (38)
ventilation heat loss → the space-heating demand.

Worksheet-proven on simulated case 49 (000565 + Vent Axia 500140 MVHR,
lodged (7a)=0): our (8) openings 0.0723 -> 0.0000, (18) 0.7223 -> 0.6500,
(25)m Jan 0.9423 -> 0.8571, all now matching Elmhurst exactly; space-
heating demand 7857 -> 7528 kWh (worksheet 7546). SAP 70.90 -> 71.43
continuous. (The residual to the worksheet's 72 is its own continuous SAP
71.69 rounding up, driven by a separate gas-combi water-heating-loss gap,
not ventilation.)

Scoped to EXTRACT_OR_PIV_OUTSIDE + MVHR only — MV-without-HR
(mechanical_ventilation=1) stays on the default-substitution path
(forcing its lodged 0 regressed 47 Howsman / 18 Jutland and is not
worksheet-validated). Corpus within-0.5 holds 72.7%, MAE 0.782 -> 0.781.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 20:15:32 +00:00
Khalim Conn-Kowlessar
7b30b464e5 feat(ventilation): credit MVHR (24a) heat recovery via PCDB Table 323 + 329
MVHR (24a) heat-recovery support, part 2: the mapper + cascade wiring.

Both source paths now resolve balanced whole-house MV with heat recovery
to the MVHR kind:
- gov-API: `_API_MECHANICAL_VENTILATION_TO_KIND` 4 → "MVHR" (was None /
  treated as natural — under-stated ventilation heat loss, over-rating).
- Elmhurst Summary: `_ELMHURST_MV_TYPE_TO_KIND` "Mechanical ventilation
  with heat recovery (MVHR)" → "MVHR" (was UnmappedElmhurstLabel, which
  blocked the whole Summary for MVHR dwellings).

cert_to_inputs resolves the in-use heat-recovery efficiency + SFP for an
MVHR cert (`_mvhr_system_values`): pick the PCDB Table 323 data point by
the lodged wet-room count (SAP 10.2 §2.6.4), multiply the raw efficiency
by the Table 329 ducts-inside-envelope in-use factor (0.90) and the raw
SFP by the per-duct-type factor (rigid 1.4), and feed:
- the §2.6.6 eq (2) effective-air-change credit (23c) → (24a)/(25)m;
- the (230a) fan electricity (in-use SFP × 1.22 × V), costed but NOT
  added to the Table 5a gains (its effect is in the efficiency).
An MVHR lodged with no PCDF index falls back to the SAP 10.2 Table 4g
default (raw efficiency 66% × 0.70, raw SFP 2.0 × 2.5).

Worksheet-proven on simulated case 49 (000565 semi + Vent Axia Sentinel
Kinetic B 500140 + gas combi → Elmhurst Current SAP 72): every MVHR line
matches Elmhurst exactly — (33) fabric heat loss 100.5923, (23c) in-use
efficiency 81.9% = 91 × 0.90, (25)m Jan 0.8571, (230a) fan electricity
415.9325, (231) total pumps/fans 501.9325. The residual SAP 71 vs 72 is
the known 000565-family space-heating-demand artifact (same -1/-2 seen on
cases 47/48), not the MVHR logic.

Corpus: within-0.5 72.6% -> 72.7%, MAE 0.788 -> 0.782, PE 3.6 -> 3.5.
The 3 gov-API MVHR certs: Flat 1 +6 -> 0 (Table 4g default path) and
12a Princes Gate +3 -> +1 (heat-recovery credit); Apartment 707 -4 -> -6
is a separate baseline under-rate (it under-rated as natural too — the
MVHR credit correctly adds ventilation loss per Elmhurst's method).
Ratcheted _MAX_SAP_MAE 0.79 -> 0.785, _MAX_PE_PER_M2_MAE 3.7 -> 3.6.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:45:37 +00:00
Khalim Conn-Kowlessar
34cbd7d66c feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF
MVHR (24a) heat-recovery support, part 1: the PCDB data layer.

PCDB Table 323 (PCDF Spec Rev 6b §A.18, Format 426; pcdb10.dat carries
Format 431, header `$323,431,...`) holds the per-wet-room SFP + heat-
exchanger efficiency for centralised MEV / MVHR units. Added
`MvhrRecord` / `MvhrDataPoint`, `parse_centralised_mv_row` /
`parse_table_323`, the ETL step, the committed jsonl, and the
`mvhr_record(pcdb_id)` runtime lookup (mirrors Table 322).

SAP 10.2 §2.6.4/§2.6.6: "MVHR ... SFP is a single value depending on the
number of wet rooms" — each test group's leading field is the wet-room
count; callers select the group matching the dwelling lodgement.
Worksheet-proven on simulated case 49 (000565, 2 wet rooms, Vent Axia
Sentinel Kinetic B 500140 → flow 21.0, SFP 0.88, efficiency 91%).

Also decoded the MVHR heat-recovery efficiency in-use factor from Table
329 (Format 432): system_type 3 ducts-inside-envelope = 0.90 (case-49
(23c) = 91 × 0.90 = 81.9%), cross-checked against system_type 10 = 0.70
(= SAP 10.2 Table 4g default heat-recovery in-use factor). "Table 4h is
no longer used – data now stored in the PCDB" (SAP 10.2 p.176).

The outside-envelope efficiency columns + with-scheme SFP blocks are
preserved verbatim in `raw` (no fixture exercises them yet).

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:29:17 +00:00
Khalim Conn-Kowlessar
4db05e843c fix(ventilation): dMEV takes lodged 0 intermittent fans, not the Table 5 default (SAP 10.2 §2)
Chasing the space-heating demand gap on "simulated case 48" (main 691 + Unknown
meter + 903 dual immersion): our SAP 55 vs Elmhurst 57. Every §10a cost line
already matched to the penny; the residual was demand — our space-heating
energy 3849.8 kWh vs Elmhurst 3513.8 (+9.6%). Traced through the worksheet: our
ventilation heat loss (38) ran ~35.5 W/K vs Elmhurst 27.76 — we were adding 20
m3/h of intermittent extract fans (the Table 5 age-band default) on a dwelling
with a decentralised mechanical extract (dMEV) system that lodges 0 fans.

SAP 10.2 §2 (PDF p.13): a whole-house mechanical EXTRACT system provides
extraction via the (23a) 0.5 system air-change rate; the lodged intermittent
extract-fan count (7a) is then explicit — a lodged 0 means 0 (the dMEV is the
ventilation), NOT "unknown". The Table 5 default is an unknown-fallback for
NATURALLY ventilated dwellings only, so it must not be substituted here.

Fix: for EXTRACT_OR_PIV_OUTSIDE, take vc.intermittent_fans as-is (no age-band
default). Worksheet-proven on two dMEV builds of cert 000565: "case 48" lodges
(7a)=0 -> our SAP 55 -> 57 EXACT; the original 000565 fixture lodges (7a)=2 and
keeps 2 (its e2e pins are unchanged). An earlier draft that forced fans=0 broke
000565 (which legitimately has 2) — corrected to "lodged as-is".

within-0.5 72.5% -> 72.6%, MAE 0.789 -> 0.788; CO2/PE unchanged. The fix also
reduces a systematic under-rating bias in the 21-cert dMEV cohort (median dSAP
-0.22 -> -0.08). Scoped to EXTRACT_OR_PIV_OUTSIDE; balanced MVHR/MV kinds left
untouched pending their own worksheet. SAP-schema regression
test_18_0_0 pin 80 -> 81 (closer to its lodged 84, same cause). Spec-pinned in
test_cert_to_inputs (dMEV-lodged-0 vs natural-default). pyright not installed
in this container -- strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 11:33:07 +00:00
Khalim Conn-Kowlessar
fd0530159f feat(tariff): complete §12 Unknown-meter clause — GSHP/WSHP main triggers off-peak (RdSAP 10 PDF p.62)
Closes the follow-up from 22fe4f41. RdSAP 10 §12's third Unknown-meter
exception bullet — "main heating is ground source or water source heat pump" —
was unimplemented. Add `_GROUND_OR_WATER_SOURCE_HEAT_PUMP_CODES` (Table 4a,
SAP 10.2 PDF p.176-177: ground 211/215/221/225 + warm-air 521/525; water
213/216/223/226 + warm-air 523/526) to the Unknown-meter off-peak triggers;
once dual, Rules 1-4 (Rule 3) resolve it to 10-hour.

AIR-source heat pumps (214/217/224/227, 524/527) are deliberately EXCLUDED —
the spec names only ground/water source. Verified the only Unknown-meter heat
pumps in the corpus are "3/10 Bedford House" (main 214 = AIR source), which
correctly KEEP STANDARD. 0 corpus certs carry a GSHP/WSHP on an Unknown meter,
so this is a spec-completeness forward guard (gauge unchanged 72.5% / 0.789),
same family as the Scotland-J wall / rafters-M roof 0-impact spec fixes.
Coverage gap noted in-code: a database-index heat pump without a 211/213-style
SAP code can't have its source type read from the code alone (rare).

Spec-pinned (test_unknown_meter_ground_or_water_source_heat_pump_triggers_off_
peak). Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
suite 2989 passed (2 known pre-existing fails). pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 10:09:59 +00:00
Khalim Conn-Kowlessar
22fe4f41b8 fix(tariff): Unknown meter + dual electric immersion → off-peak per §12 (RdSAP 10 PDF p.62)
Supersedes the previous "verified non-fix" doc (3548f1f3): the spec DOES make
this a fix — Khalim was right that the Unknown-meter branch is driven by the
heating/water system, not a blanket STANDARD.

RdSAP 10 §12 (PDF p.62): "If the electricity meter is unknown, treat as single
meter EXCEPT where main heating OR WATER HEATING are intended to run off an
off-peak tariff (per systems listed in the text box above) ... If that results
in a dual meter, assign tariff per rules 1 to 4." The text-box off-peak systems
include DUAL ELECTRIC IMMERSION. Our `rdsap_tariff_for_cert` only triggered the
Unknown→off-peak exception on a storage/CPSU MAIN — it ignored the
dual-electric-immersion WATER-heating trigger, so an Unknown-meter dwelling
with a non-storage main (e.g. room heaters) + dual immersion was billed
STANDARD (13.19p flat) when it should be dual → Rules 1-4 on the main.

Fix: thread `water_is_off_peak_dual_immersion` (whc 903 + immersion lodged dual
via `_immersion_is_single is False`) into the Unknown-meter branch; when any
text-box trigger is present, resolve via the same Rules 1-4 dispatch (room
heaters → Rule 3 → 10-hour). Single-immersion / instantaneous (whc 909) certs
correctly stay STANDARD (no text-box system).

Worksheet-validated on "simulated case 48" (main 691 + Unknown meter + 903 dual
immersion): Elmhurst 10-Hour Off Peak, SAP 57; ours 45 → 55 (7-hour gives 45,
confirming 10-hour). Flips exactly ONE corpus cert — Apartment 241 (the genuine
-5.38 under-rater, main 691 + dual immersion) -5.38 → -1.05; every other
Unknown+dual-immersion cert already has a storage main (Rule 2). Corpus
within-0.5 holds 72.5%, MAE 0.793 → 0.789 (improved). CO2/PE unchanged.

GSHP/WSHP-main trigger (the other §12 Unknown exception bullet) is a separate
follow-up. Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
000565 e2e 11/11, suite 2987 passed (2 known pre-existing fails). pyright not
installed in this container — strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 09:58:02 +00:00
Khalim Conn-Kowlessar
3548f1f31a docs(tariff): record Unknown-meter off-peak as a verified non-fix (RdSAP 10 §12 Rules, table_12a)
Khalim's hand-built "simulated case 48" Elmhurst worksheet (main 691 room
heaters + Unknown meter + 903 dual electric immersion + cylinder) proves
Elmhurst resolves an Unknown meter + Rule-3 room-heater main to 10-Hour Off
Peak — Elmhurst SAP 57; ours (STANDARD) 45; routing Unknown+Rule3 to off-peak
(10h) gives 55, 7h gives 45 (so Elmhurst uses 10-hour, RdSAP 10 §12 Rule 3,
PDF p.62). So the prior "Rule 3 is not off-peak evidence" comment was wrong
about Elmhurst's behaviour.

But adopting it REGRESSES the lodged-register corpus 72.5%->71.8% / MAE
0.793->0.827: of 11 Unknown+Rule-3 corpus certs only Apartment 241 improves
(-5.38->-1.05); the other 10 overshoot +2.7..+9.1 (Flat 2 +9.11). The
register's meter_type=3 certs were lodged with STANDARD-tariff costing — the
gov-API "Unknown" is lossy and does not mean off-peak. North star is
reproducing the lodged register, not Elmhurst's deliberate-Unknown worksheet,
so KEEP STANDARD (same "Elmhurst != noisy register" family as
roof-windows/shutters).

Comment-only; no behaviour change (corpus gauge unchanged 72.5% / 0.793).
pyright not installed in this container — strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 09:48:21 +00:00
Khalim Conn-Kowlessar
2ac5ec6eb5 chore(tooling): add median column to corpus profiler; document shutter non-implementation
profile_corpus_error.py: print median signed error alongside the mean in each
feature bucket. The mean is dragged by fat-tail register anomalies (e.g. electric
room heaters mean -1.09 but median -0.01) — median is the outlier-resistant lens
for finding TRUE systematic slices, so hunt by |median|, not |signed|.

heat_transmission.py: document why permanent-shutter R is deliberately NOT applied
(Elmhurst uses R=0.04 curtains on every window incl. insulated shutters, proven on
case 46; API-path trial worsens MAE). Comment-only.

pyright not installed locally — strict type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:46:00 +00:00
Khalim Conn-Kowlessar
6a4539f26b fix(fuel): close case 47 — correct the second main heating system's fuel (off-peak pricing + Elmhurst Summary solid-fuel)
Two second-main fuel errors mis-cost a dual-main dwelling whose two main systems
burn different fuels (SAP 10.2 §10a worksheet (213) bills main 2 at its own fuel):

1. Off-peak/legacy scalar cost path (calculator.py + cert_to_inputs.py): main 2's
   kWh was priced at main 1's `space_heating_fuel_cost_gbp_per_kwh` scalar. Split
   main 1 vs main 2 and price main 2 at its OWN rate via the new
   `_main_2_space_heating_fuel_cost_gbp_per_kwh` (+ CalculatorInputs field).
   Scoped to a NON-electric second main (wood/oil/coal) — an electric second
   main keeps main 1's scalar (its off-peak Table 12a split is the deferred §10a
   slice; per-system splitting it regresses the off-peak electric cohort, certs
   13 Parkers Hill / 34 Dunley Road). 0 corpus impact (no corpus cert has a
   non-electric second main on an off-peak meter).

2. Elmhurst Summary mapper (mapper.py): when §14.1 omits the Fuel Type cell, a
   fuel-fired second main (room-heater SAP code) inherited main 1's fuel. Derive
   it from the SAP code's Table 4a category (solid 631-636 -> house coal, gas ->
   mains gas, liquid -> oil) before the main-1 inherit, mirroring
   `_elmhurst_secondary_fuel_from_sap_code` (same modal sub-fuel caveat). Boiler
   codes (<601) still inherit main 1 (case 6 oil rads+UFH).

simulated case 47 (electric room heaters + solid room heaters 633): our SAP
37.81 -> 55.09 vs Elmhurst current 57 (residual is the wood-vs-coal sub-fuel the
Summary export does not carry). Corpus unchanged 72.5% / MAE 0.793; batch 0
raised / 0 diverge; 000565 e2e green. (mapper.py also carries an earlier,
behaviour-free roof-window doc comment.) Spec-cited unit pins added (AAA).
pyright not installed locally — strict type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:46:00 +00:00
Khalim Conn-Kowlessar
44fff76722 fix(fuel): raise UnpricedFuelCode for unrecognised fuels instead of silently defaulting to mains gas
`table_32.unit_price_p_per_kwh` silently returned the mains-gas default
(3.48 p/kWh) for any fuel code it could not resolve to a Table 32 price or a
translatable gov-API enum. An unhandled fuel billed at the gas rate mis-costs
the dwelling (same failure mode as the dual-main wood-vs-electric over-cost).
Raise `UnpricedFuelCode` (new, mirrors MissingMainFuelType / UnmappedSapCode)
so the gap surfaces at the price boundary. `None` (no fuel lodged) still
defaults — callers resolve "no system" upstream.

0 corpus impact: all 1000 certs compute (every lodged fuel resolves), so this
is a forward guard against future/unmapped fuels. Unit pin added; existing
None-default test docstring tightened. pyright not installed locally — strict
type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:31:04 +00:00
Khalim Conn-Kowlessar
702150002f fix(fuel): cost main heating system 2 at its own fuel price, not main 1's (SAP 10.2 §10a worksheet line 213)
Main heating system 2's space-heating fuel cost (worksheet (213)) was billed
at main system 1's Table 32 unit price (`main_2_high_rate_gbp_per_kwh` reused
`main_1_high_rate_gbp_per_kwh`). For a dual-FUEL pair this grossly mis-costs the
second main: cert 10032957680 "Copse Cottage" (main 1 electric room heaters
fuel 30, main 2 wood logs fuel 6) charged its 9481 kWh of wood at 13.19 p/kWh
instead of 4.23 p/kWh — +£850/yr → SAP 21.75 vs lodged 45.

Route main 2 through its own fuel code (`_main_fuel_code(details[1])`), mirroring
the existing secondary-fuel handling. Copse Cottage 21.75 -> 45.94. Corpus
within-0.5 holds 72.5%, SAP MAE 0.815 -> 0.793 (ratcheted ceiling 0.82 -> 0.80);
CO2/PE unchanged. Same-fuel dual mains (gas+gas) unaffected. Off-peak-tariff
dual-fuel mains still defer to the legacy scalar path (separate slice).

Spec-cited unit pin added (AAA). pyright not installed locally — strict type
gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:31:04 +00:00
Khalim Conn-Kowlessar
a9632937d5 fix(ventilation): use lodged extract-fan count when known, not max(lodged, age default) (RdSAP 10 §4.1 Table 5, PDF p.28)
Table 5 reads "Number of extract fans if known; if number is unknown:
[age-band default]" — the default is an UNKNOWN-fallback, NOT a floor. The
cascade applied `max(lodged, table_5_default)`, flooring a genuinely-lodged
count up to the age-band minimum: e.g. an age H-M dwelling lodging 2 extract
fans was billed at the 6-8-room default of 3, over-counting ventilation line
(8) and the heat-loss coefficient. Fixed to `lodged if lodged > 0 else
default` (a lodged 0 is the Elmhurst/RdSAP "unknown" form → default; any
positive count is taken literally).

Surfaced by Khalim's Elmhurst stress worksheet (simulated case 46): this was
its last ventilation residual — our Jan effective ACH 9.14 -> 9.0748 (exact
match to the accredited worksheet), SAP 29 -> 30 = Elmhurst, cost £1496 vs
£1493. Corpus IMPROVED: within-0.5 71.6% -> 72.5%, MAE 0.819 -> 0.815 (the
max-flooring over-counted ventilation on every cert lodging fans below its
age default). Floor ratcheted 0.71 -> 0.72. pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 06:22:26 +00:00
Khalim Conn-Kowlessar
34e52a893c fix(heating): assume portable-electric secondary for unheated habitable rooms (SAP 10.2 Appendix A.2.2)
When the main heating system does not heat every habitable room (heated rooms
< habitable rooms), SAP 10.2 Appendix A.2.2 assumes the unheated rooms are
served by a portable-electric secondary heater, so the Table 11 secondary
fraction (0.10 for a boiler main) must be costed at the electricity tariff —
even when the cert lodges no explicit secondary system.

`_secondary_fraction` previously returned 0 unless a secondary was lodged or
the main was a forced-secondary electric-storage code, dropping the assumed
secondary and billing 100% of space heat to the (cheaper) main fuel — an
over-rate. Added an `unheated_habitable_rooms` trigger plus
`_has_unheated_habitable_rooms(epc)`, which prefers the lodged
`any_unheated_rooms` flag and guards the gov-API `heated_rooms_count == 0`
"not provided" sentinel. The secondary fuel/efficiency cascade already
defaults to portable electric (code 693) when no secondary code is lodged.

Worksheet-validated on simulated case 46 (heated 4 < habitable 7, no lodged
secondary): the assumed 10% electric secondary (2289 kWh, ~£260) lifted our
SAP 39 -> 29.35 vs accredited Elmhurst 30 (cost £1502 vs £1493, within 0.6%).

Corpus UNCHANGED (71.6% / MAE 0.819): all 17 corpus certs with heated <
habitable already lodge an explicit secondary description, so the gov-API
path was already costing it; this only adds the assumed secondary where none
is lodged (Elmhurst / reduced-field path). pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 06:15:37 +00:00
Khalim Conn-Kowlessar
d7a60efcdf fix(uvalues): thread glazing gap into pre-2002 window U fallback (RdSAP 10 Table 24, PDF p.50)
`u_window` hard-coded the 12 mm gap row for pre-2002 double/triple glazing
(double 2.8, triple 2.1), ignoring the lodged glazing gap. Table 24 splits
the pre-2002 rows by gap: double 6mm=3.1 / 12mm=2.8 / 16mm+=2.7; triple
6mm=2.4 / 12mm=2.1 / 16mm+=2.0 (PVC/wooden), with a metal-frame column
(+0.5/+0.5/+0.5 ish). Added a `glazing_gap` parameter + `_glazing_gap_row`
helper and wired `w.glazing_gap` through the synthesised-window caller in
heat_transmission.

Corpus impact nil by design: the gov-API mapper already resolves per-window
U gap-aware via `_API_GLAZING_TYPE_GAP_TO_TRANSMISSION` (e.g. code 3 + gap
"16+" → 2.7), so corpus certs use that lodged per-window U, not this fallback.
This aligns the reduced-field / worksheet fallback path with the mapper and
Table 24. Unknown gap still defaults to the 12 mm row.

(Metal frames are not distinguishable on the gov-API path — only a `pvc_frame`
boolean exists and Table 24 groups PVC+wooden — so the PVC/wooden U stands
there; the metal column applies only where frame material is lodged.)

Spec-pinned: pre-2002 double + triple gap-row tests. pyright not installed.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-20 14:14:31 +00:00
Khalim Conn-Kowlessar
fc5f10ea92 fix(rating): floor the continuous SAP score at 1 (SAP 10.2 §13 / RdSAP 10 §13)
The SAP rating is spec-floored at 1 ("if the result of the calculation is
less than 1, the rating is 1"). `sap_rating_integer` already clamps, but the
continuous `sap_score_continuous` did not — so a degenerate dwelling could
emit a physically impossible negative SAP. Apply the same max(1, …) floor to
the continuous value (the un-rounded part is for sensitivity near real
ratings, not for negative ratings).

Removes a -12.3 accuracy outlier on the committed corpus (cert 422000111926,
lodged at the floor of 1, was computing -11.3): within-0.5 70.2% -> 70.3%,
MAE 0.845 -> 0.833. Ratcheted the corpus MAE ceiling to 0.84. Unit-pinned in
test_calculator.

pyright not installed in this codespace (strict gate not run locally).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:03:13 +00:00
Khalim Conn-Kowlessar
a7de8c5c35 Merge remote-tracking branch 'origin/main' into feature/per-cert-mapper-validation 2026-06-18 15:00:32 +00:00
Khalim Conn-Kowlessar
8942d45772 fix(fuel): price secondary dual-fuel/anthracite at their own rate, not the colliding LPG code (RdSAP 10 Table 32)
The gov-API lodges secondary fuel as an enum whose value can COLLIDE with a
different same-valued RdSAP 10 Table 32 / SAP 10.2 Table 12 fuel code:
  - enum 9  = "dual fuel (mineral and wood)"  vs Table code 9  = LPG SC11F
  - enum 5  = "anthracite"                    vs Table code 5  = LPG (bulk)
The main-fuel boundary already canonicalises these (`_GOV_API_COLLISION_
FUELS`), but the SECONDARY-heating cost + CO2/PE paths never did — they took
the bare same-value lookup, so a dual-fuel room heater was priced as LPG
(3.48 vs dual-fuel 3.99 p/kWh) and emitted as LPG (CO2 0.241 vs 0.087),
and an anthracite secondary as bulk LPG (12.19 vs 3.64 p/kWh). The price
under-count over-rates SAP; the CO2 over-count inflates emissions.

Fix: add enum 9 to `_GOV_API_COLLISION_FUELS` (5 and 33 were already there)
and canonicalise the secondary fuel code on both the cost
(`_secondary_fuel_cost_gbp_per_kwh`) and factor (`_secondary_fuel_code`)
paths, mirroring the main-fuel boundary. canonical_fuel_code only touches
{5,9,33}, so genuinely Table-coded secondaries (House coal 11, wood logs 20,
community fuels 30-32) are left unchanged — confirmed by a full-map audit.

Corpus: within-0.5 69.7% -> 70.2% (MAE 0.854 -> 0.845; dual-fuel-secondary
cohort 42.9% -> 49.0%, signed +0.55 -> +0.41) and CO2 MAE 0.12 -> 0.08 t/yr
(bias +0.04 -> 0.00). Ratcheted the corpus floors (within 0.70, MAE 0.85,
CO2 0.09, PE 4.0). A prior session deferred enum 9 ("direction not
understood") while the EPC PE/CO2 lens was confounded by the climate-cascade
bug (fc7c4d2d); on the corrected lens the over-rate direction is clear.

pyright not installed in this codespace (strict gate not run locally).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 14:52:58 +00:00
Khalim Conn-Kowlessar
fc7c4d2d3b fix(climate): compute EPC CO2/PE on the postcode demand cascade (SAP 10.2 Appendix U p.124)
The SAP/EI rating is computed on UK-average weather (Appendix U Tables
U1-U3 region 0) so ratings are nationally comparable, but Appendix U
paragraph 1 (PDF p.124) requires that "other calculations (such as for
energy use and costs on EPCs) are done using local weather. Weather data
for each postcode district are taken from the PCDB". `Sap10Calculator.
calculate` ran ONE cascade (UK-average) and fed it to SAP, CO2 AND primary
energy, so every cert's EPC-displayed CO2/PE were computed on the wrong
climate. Because most of England is warmer than the UK-average, this
systematically OVER-counted heating demand on the emissions/PE outputs.

The two cascades (`cert_to_inputs` rating, `cert_to_demand_inputs`
postcode) already existed; this wires the demand cascade into the
production entry point and grafts its CO2/PE onto the rating result (SAP
unchanged). The corpus gauge's longstanding +5% CO2/PE over-estimate was
mostly this climate bug, NOT (as previously diagnosed) per-cert mapper
fidelity:
  CO2 MAE 0.26 -> 0.12 t/yr  (bias +0.18 -> +0.04)
  PE  MAE 13.6 -> 3.8 kWh/m2 (bias +9.0  -> +0.24)
  SAP within-0.5 = 69.7% (rating cascade, unchanged)

Worksheet-validated to 1e-4 on simulated case 45 (heat-pump ground-floor
flat, postcode W6): the P960 prints the current dwelling twice — Block 1
on UK-average weather (SAP 60.5318, CO2 692.13) and Block 2 on postcode
weather (CO2 626.78, PE 6581.59). Both reproduce exactly. Added a tracked
case-45 Summary fixture + two-cascade cascade pin as a permanent guard,
and ratcheted the corpus CO2/PE ceilings to 0.13 / 4.2. The e2e Elmhurst
suite (Block-1 line refs) now pins the rating cascade directly; the two
Vaillant overlay snapshots refreshed to demand-cascade CO2/PE.

pyright not installed in this codespace (strict gate not run locally);
change is type-trivial (dataclasses.replace over SapResult).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 14:15:34 +00:00
Khalim Conn-Kowlessar
72ef0f0e7b fix(water): don't apply heat-pump water SCOP to a separate immersion (SAP N3.7a)
When a heat-pump cert lodges a PCDB Table 362 record, the APM override
set BOTH the space efficiency (N3.6) and the water efficiency (N3.7a)
from the heat pump unconditionally. But the PCDB η_water applies only
when the DHW is heated BY the heat pump (water-heating code "from main":
901/902/914). A separate electric immersion (WHC 903) heats the water at
100% regardless of the space system, so applying the HP's water SCOP
(187.5% × 0.6 in-use = 112.5%) under-counted the immersion's hot-water
fuel.

Gate the η_water override on the DHW-from-main codes; a separate immersion
keeps its own 100% efficiency. Space η_space still always uses the APM
value (the heat pump is the space main).

Worksheet-validated to 1e-4 on simulated case 45 (HP space + WHC-903
immersion): water fuel (62) 1893.57 -> 2130.2639, total cost (255)
619.7433, CO2 692.13 — all matching the P960 exactly; SAP 60.53 -> rounds
to the worksheet's 61. RdSAP-21.0.1 corpus unchanged (no HP+WHC903 certs
in it). Pinned in test_cert_to_inputs (immersion fuel is main-independent).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 13:44:51 +00:00
Khalim Conn-Kowlessar
9b0c590bf8 fix(heat-transmission): bill a ground-floor flat's ground floor (RdSAP 10 §3.12)
The flat floor-exposure heuristic keys on dwelling_type: a flat defaults
to has_exposed_floor=False (assuming a heated dwelling below). The
Elmhurst Summary path lodges a ground-floor flat's vertical position as a
"Ground floor" floor_type rather than the API floor_heat_loss=1 exposed
code, and the mapper can label such a flat "Top-floor flat" — so the
cascade dropped the ground floor entirely (a ground floor is in contact
with the ground and carries heat loss).

Treat a "ground floor" floor_type as a heat-loss floor, overriding the
dwelling-level suppression upward — mirroring the existing "another
dwelling below" party override downward.

Worksheet-validated to 1e-4 on simulated case 45 (a ground-floor flat
the mapper labelled "Top-floor flat"): floor (28a) 0 -> 25.38 W/K,
fabric (33) 75.63 -> 101.0104, HTC (39) 112.93 -> 145.3579, all matching
the P960 exactly; SAP 67.81 -> 62.52. RdSAP-21.0.1 corpus within-0.5
69.5% -> 69.7% (MAE 0.859 -> 0.854). Floors ratcheted. Pinned in
test_heat_transmission (ground-floor billed + party-floor suppressed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 13:16:44 +00:00
Jun-te Kim
d87718f316 Merge remote-tracking branch 'origin/main' into feature/hyde_make_it_more_accurate_with_tests
# Conflicts:
#	datatypes/epc/domain/mapper.py
2026-06-17 09:05:37 +00:00
Khalim Conn-Kowlessar
e136e937d6 fix(heat-transmission): match roof description per part by kind (RdSAP 10 §5.11)
The deduplicated `epc.roofs[]` list cannot be indexed 1:1 against the
building parts (190/329 multi-part certs have len(roofs) != len(parts)),
so every part's `u_roof` consumed a SINGLE join of all roof descriptions.
That leaked one part's insulation state onto another: a "Flat, no
insulation" extension dragged a "Pitched, insulated (assumed)" main roof
to the uninsulated 2.30, ~3x over-stating its heat loss. 3-part certs
systematically under-rated (56% within-0.5, mean -0.79 SAP).

Partition the non-RR roof descriptions into flat vs pitched/sloping and
match each part to its own kind (`_main_roof_descriptions_by_kind`),
falling back to the global join when a part's kind has no matching entry.

Corpus cert 100010129331: roof 110.5 -> 31.3 W/K, +13.10 -> -0.05 SAP.
RdSAP-21.0.1 within-0.5 68.8% -> 69.5% (MAE 0.888 -> 0.859; PE 13.9 ->
13.6); 3-part cohort 56% -> 61%. Floors/ceilings ratcheted. Pinned in
test_heat_transmission (by_kind split + mixed-roof no-contamination).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 00:48:50 +00:00
Khalim Conn-Kowlessar
2a4d67e396 feat(conservatory): §6.1 solar gains + TFA-occupancy (demand-side)
Close the §6.1 conservatory demand cascade per RdSAP 10 §6.1 + Table 25.

Solar gains (§6, solar_gains.py) — Table 25 note (PDF p.51): "The
orientation of windows in a conservatory is not recorded, thus solar
gains are calculated using the default solar flux (East/West orientation,
with 20° pitch for roof windows)." The glazed wall bills onto the (76)
East line (vertical, average-overshading Z); the glazed roof onto the
(82) roof-window line (20° pitch, Z=1.0), both at Table 25 g=0.76, FF=0.70.

TFA-occupancy (mapper) — §6.1: the conservatory floor area is added to the
dwelling total floor area. TFA drives occupancy → §5 internal gains + §4
hot-water demand, so the non-separated conservatory's floor area now
enters `EpcPropertyData.total_floor_area_m2` (the worksheet's (4) = 95.38
carries it). Separated conservatories (§6.2) stay excluded.

Pinned against the case-44 P960 demand cascade at abs=1e-4: (73) internal
gains 625.1759, (83) solar gains 495.8655, (95) useful gains 1079.6510,
(99) space heating per m² 89.8073 — the full §6.1 chain reproduces EXACTLY.

The whole-dwelling SAP (72.9517) / CO2 (3241.8656) are not pinned: the
case-44 Summary omits the House-Coal secondary heater (SAP 633) the P960
descriptor carries (cf. case 43), so the cascade computes no secondary —
the entire residual (+349.77 kg CO2). A Summary-input defect, independent
of §6.1; every conservatory-affected line ref is exact. Worksheet harness
stays 47/47 0-raised; corpus unchanged (API path; mirror is the next slice).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 23:21:08 +00:00
Khalim Conn-Kowlessar
fe3bf4eaed fix(ventilation): read Blower Door AP50 pressure test (Summary)
SAP 10.2 §2 (17)-(18): a measured/design air permeability at 50 Pa from a
Blower Door test routes infiltration via `(18) = AP50/20 + (8)`, in
preference to the components-based (16) estimate. The Elmhurst extractor
read only the AP4 ("Pulse") column of §12.2, so a Blower Door result
(§12.2 "Pressure Test Result (AP50)") fell through to the structural-
infiltration default — over-counting ventilation heat loss.

Surfaced by simulated case 44 (AP50 4.50): effective air change rate was
0.81 vs the worksheet's 0.58 (+38% ventilation loss). The cascade already
supports `air_permeability_ap50` (preferred over AP4); this wires the read
end to end (extractor → ElmhurstSiteNotes → SapVentilation → cert_to_inputs).

Pinned against the case-44 P960 §2 at abs=1e-4: (18) infiltration 0.3417
(= 4.5/20 + 0.1167) and (25) Jan effective ach 0.5812. Worksheet harness
stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 23:18:17 +00:00
Jun-te Kim
4d14607e7e Add SAP-16.2 schema coverage + single-glazing fix; flat party-wall fix; pin 2 certs
SAP-Schema-16.2 (datatypes/epc/domain/mapper.py):
- 16.2 is structurally an RdSAP-17.1 cert under a different name; add
  _normalize_sap_schema_16_2 (field renames + defaults) and dispatch to the
  tested from_rdsap_schema_17_1 mapper. uprn_100020933699 maps → SAP 71.
- Honour a "Single glazed" windows description when multiple_glazing_type="ND"
  (was defaulting to double) → RdSAP-21 code 5; eng 72→71 (lodged 70).
- 4 regression tests + sap_16_2.json fixture; 0 new pyright errors.

Flat party-wall fix (domain/sap10_calculator/worksheet/heat_transmission.py):
- Full-SAP flats carry flatness in dwelling_type, not property_type, so the
  party-wall default fell through to the 0.25 house value instead of the RdSAP
  Table-15 flat 0.0. Add _is_flat_or_maisonette_dwelling fallback + regression
  test. uprn_10093116529 80→81 (matches the cert's lodged party u_value 0).

Accuracy corpus pins (tests/domain/sap10_calculator/test_real_cert_sap_accuracy.py):
- uprn_10093116543 (SAP-17.1 gas-combi semi): engine 81 (Elmhurst 77; documented
  full-SAP→RdSAP residual — measured wall/floor U + PCDB boiler vs RdSAP defaults).
- uprn_10093116529 (SAP-17.1 g/f flat): engine 81 (Elmhurst 78).

devcontainer: add poppler-utils (pdfinfo) for the documents-parser PDF fixtures.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-16 18:53:00 +00:00
Khalim Conn-Kowlessar
d4d2b222fc feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume)
Wire the non-separated conservatory into the §3 heat-transmission +
§1 dimensions cascade per RdSAP 10 §6.1 (PDF p.49) + Table 25 (p.51):

  "The floor area and volume of a non-separated conservatory are added to
   the total floor area and volume of the dwelling. Its roof area is taken
   as its floor area divided by cos(20°), and wall area is taken as the
   product of its exposed perimeter and its height. ... The conservatory
   walls and roof are taken as fully glazed ... Glazed walls are taken as
   windows, glazed roof as rooflight."

New `worksheet/conservatory.py` derives the geometry:
  - height from the equivalent storey count (§6.1: 1 storey → ground-floor
    room height; 1½ → ground + 0.25 + 0.5×first; etc.);
  - glazed WALL → window (27) at Table 25 U (double 3.1 / single 4.8) with
    the §3.2 curtain resistance (R=0.04) → U_eff 2.758;
  - glazed ROOF → rooflight (27a) at Table 25 roof U (double 3.4 / single
    5.3) + curtain → U_eff 2.993;
  - FLOOR → (28a) via BS EN ISO 13370 as an uninsulated SOLID ground floor
    with 300 mm walls (§5.12, spec p.43), exposed perimeter = glazed
    perimeter → U 0.89;
  - glazed wall + roof + floor areas join (31)/(36); the fully-glazed
    structure walls/roof add nothing (the glazing IS the window/rooflight).

`dimensions_from_cert` adds the conservatory floor area to TFA (4) and
floor area × height to volume (5) (feeds ventilation (8)), without making
it a storey (avg storey height for §2 infiltration is unchanged).

Pinned against the simulated case-44 P960 §3 at abs=1e-4 — every line ref
EXACT: (4) 95.3800, (5) 257.1630, (27) 96.1169, (27a) 38.2201, (28a)
21.4164, (29a) 35.5852, (30) 7.4688, (31) 294.2900, (33) 207.3274,
(36) 23.5432. The remaining whole-dwelling SAP/CO2 gap is the §6 solar
gains, closed in the next slice. Worksheet harness stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 15:59:26 +00:00
Jun-te Kim
928fbbc33a Merge remote-tracking branch 'origin/main' into feature/hyde_make_it_more_accurate_with_tests
# Conflicts:
#	applications/sharepoint_renamer/handler.py
#	domain/sap10_calculator/worksheet/heat_transmission.py
2026-06-16 15:23:52 +00:00
Jun-te Kim
2f0eb49eee Checkpoint: UPRN 10093116543 Elmhurst build + devcontainer VNC/Playwright + perms
- Add SAP-accuracy sample for uprn_10093116543 (epc.json, elmhurst_inputs.md,
  summary/worksheet PDFs)
- Persist hyde viewer stack (xvfb/fluxbox/x11vnc/novnc/websockify) and Playwright
  chromium in the backend devcontainer; forward noVNC 6080
- Broaden .claude/settings.local.json allowlist (display/python/grep/tail)
- In-progress campaign mapper/cert_to_inputs work carried from prior cert

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-16 15:21:56 +00:00
Khalim Conn-Kowlessar
b55b969b84 fix(water-heating): use lodged cylinder_heat_loss declared-loss factor
The gov API lodges a manufacturer's declared cylinder loss factor
(kWh/day) in `sap_heating.cylinder_heat_loss`, in which case it leaves
the cylinder volume / insulation type / thickness None. That field was
undeclared on the 21.0.x schemas, so `from_dict` dropped it — then
`_cylinder_storage_loss_override` hit its insulation-None / volume-None
guards and returned None, dropping the §4 storage loss ENTIRELY. The
dwelling over-rated (the declared loss is typically ~1.5 kWh/day ≈
550 kWh/yr).

SAP 10.2 §4 branch a) (PDF p.136): when the declared loss factor is
known, storage loss (50) = (48) declared loss × (49) Table-2b
temperature factor — replacing the Table 2 V×L×VF computation.

- declare `cylinder_heat_loss` on RdSapSchema21_0_0/21_0_1.SapHeating +
  EpcPropertyData.SapHeating; thread through the 21.0.x mappers.
- `cylinder_storage_loss_monthly_kwh` gains `declared_loss_kwh_per_day`:
  when set, combined_55 = declared × TF (volume/insulation unused).
- `_cylinder_storage_loss_override` resolves the declared loss BEFORE the
  insulation/volume guards (the gov omits those when the loss is lodged).

12 /tmp certs carry it (mean |err| 3.00 -> 2.51; the clean ones close
hard, e.g. 2360 2.65 -> 0.30, 0245 2.25 -> 0.53). Corpus within-0.5
67.0% -> 67.3% (MAE 1.025 -> 1.020); /tmp 71.2% -> 71.4% (0.889 ->
0.882). Worksheet harness 47/47; regression = only the 3 pre-existing
fails; pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 05:27:47 +00:00
Khalim Conn-Kowlessar
7cfd54129b fix(mapper): read the dropped rafter_insulation_thickness API field
Roofs lodged insulated at rafters carry their thickness in a DEDICATED
gov-EPC API field, `rafter_insulation_thickness` (e.g. "225mm"), while
`roof_insulation_thickness` stays None (rafters aren't loft joists). That
field was undeclared on the 21.0.x schemas, so `from_dict` silently
dropped it — the rafter certs only *looked* redacted (roof EER 2-4 =
insulated, yet no thickness), and the cascade fell to the Table 18 col (2)
unknown default (2.30), badly under-rating them.

- declare `rafter_insulation_thickness` on RdSapSchema21_0_0/21_0_1 +
  EpcPropertyData.SapBuildingPart (mirrors the existing
  sloping_ceiling_/flat_roof_insulation_thickness dropped-field handling).
- thread it through `from_rdsap_schema_21_0_0/21_0_1` (older schemas get
  None via getattr).
- `heat_transmission` prefers `rafter_insulation_thickness` over
  `roof_insulation_thickness` when the part is at-rafters, so the measured
  RdSAP 10 §5.11.2 Table 16 column (2) row applies (225 mm → 0.25).

Completes the rafters roof fix: with the real thickness read, the rafter
certs are recovered rather than over-stated — cert 3100-8675-0922-8628
(band E, rafters 225mm) +8.93 → +0.43 SAP. Corpus within-0.5 67.0%
(MAE 1.025) and /tmp 71.2% (MAE 0.889) — both NET ABOVE the pre-rafters
baseline (66.9% / 70.6%). Worksheet harness 47/47; regression = only the
3 pre-existing fails; pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 05:04:39 +00:00
Khalim Conn-Kowlessar
5d556faf86 fix(roof): bill at-rafters insulation on RdSAP 10 Table 16/18 column (2)
`u_roof` only implemented the joist column, so roofs lodged insulated at
rafters (`roof_insulation_location == 1`) were mis-billed at the joist U
on both the API and Summary paths — under-stating loss, over-rating SAP.

RdSAP 10 §5.11.2 Table 16 (spec p.42-43) gives a distinct "insulation at
rafters" column (2): the rafter cavity is shallower than a loft void, so
the same depth yields a higher U (200 mm: rafters 0.29 vs joists 0.21).
§5.11 Table 18 (p.45) likewise carries a rafters column (2) for unknown /
as-built thickness (footnote (1): "The value from the table applies for
unknown and as built") — band A-D = 2.30, E = 1.50, F = 0.68, diverging
from the joist column's 100 mm-equivalent 0.40 default (footnote (4)).

- add `_ROOF_RAFTERS_BY_THICKNESS` (Table 16 col 2) + `_ROOF_RAFTERS_BY_AGE`
  (Table 18 col 2) to rdsap_uvalues; `u_roof` selects them via a new
  `insulation_at_rafters` flag (ignored for flat / sloping-ceiling roofs).
- `heat_transmission` derives the flag PER BUILDING PART from
  `roof_insulation_location` (gov-API int 1 / Summary "R Rafters"), which
  also fixes the multi-part dedup-roof-join problem: each part's own
  location now drives its U, replacing the unattributable joined
  `epc.roofs[]` description.

Worksheet-validated to 1e-4: simulated case 41 (4-bp — Ext1 rafters 200mm
→ 0.29, Ext3 rafters As-Built band F → 0.68; roof total 24.8350) and case
42 (6 variants — rafters 50mm → 0.88, rafters unknown band C → 2.30,
joists/none unchanged). Case 40 stays exact (roof 35.340, total 441.1606);
worksheet harness 47/47.

Corpus within-0.5 66.9% → 66.5% (gates 0.65/1.08 hold) — a spec-correct
shift, NOT a regression: all 15 corpus rafter certs carry redacted (None)
thickness yet lodge roof EER 2-4 (insulated), so the open API blanked a
specified thickness and the spec's unknown-rafter 2.30 default correctly
over-states them. Recovery needs a roof-EER→thickness inference on the
API path (follow-up), not a change to the U-table.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 04:42:44 +00:00
Jun-te Kim
5c11fd35c8 Validate SAP calculator vs Elmhurst; fix reduced-field window U; add accuracy harness
Reduced-field window U: heat_transmission derived the synthesised-window
raw U from u_window(all None) -> the 2.5 placeholder regardless of glazing.
Now routes the (uniform) glazing_type code through u_window (RdSAP Table 24)
so e.g. double pre-2002 reads 2.8, not 2.5. Only the pre-SAP10 reduced-field
path is affected (21.0.1 certs carry per-window U upstream) — the RdSAP-21.0.1
corpus gauge is unchanged at 66.9% within-0.5.

test_real_cert_sap_accuracy: pin uprn_10002468137 (RdSAP-17.1, all-electric
storage heaters) at SAP 61, validated against Elmhurst on identical inputs
(dual off-peak immersion, 110 L cylinder, 2 baths). Our engine reproduces
Elmhurst's fuel cost to the penny; lodged 55 is the old SAP-2012 schema.

Tooling to grow the accuracy corpus:
- scripts/fetch_real_life_epc_sample.py — capture a cert by UPRN into the corpus.
- scripts/compare_epc_paths.py — diff gov-API vs Elmhurst-summary EpcPropertyData
  and run both through the engine, localising mapper vs calculator differences.
- skill validate-cert-sap-accuracy — the end-to-end loop (capture -> Elmhurst
  inputs -> human builds -> compare -> reconcile -> pin in the test).
- skill epc-to-elmhurst-rdsap-inputs reference: corrected immersion (code 1=dual),
  cylinder size (code 2 = Normal/110 L), and bath-count (WWHRS sub-tab) mappings.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-15 15:26:11 +00:00
Khalim Conn-Kowlessar
e7177a8bd4 fix(electric-heaters): code-699 "electric heaters assumed" bills Table 12a direct-acting split
A "No system present: electric heaters assumed" lodging carries SAP
Table 4a code 699 (electric room heaters) but RdSAP main_heating_category
1, NOT 10. `_table_12a_system_for_main` keyed the direct-acting-electric
routing on category==10 only, so the category-1 form fell through to None
and `_space_heating_fuel_cost_gbp_per_kwh` billed space heating 100% at
the off-peak LOW rate — as if direct-acting room heaters charged overnight
like storage.

Per RdSAP 10 §12 Rule 3 (PDF p.62) electric room heaters (691-694, 699)
route to the 10-hour tariff, and SAP 10.2 Table 12a Grid 1 (PDF p.191)
gives the "other direct-acting electric" row a 0.50 high-rate fraction at
10-hour (1.00 at 7-hour). Route those SAP codes — the same set §12 Rule 3
already uses — to OTHER_DIRECT_ACTING_ELECTRIC alongside the category-10
gate.

Found via the PE/CO2-vs-cost split on the worst over-rater in the /tmp
sample: cert 2958 PE +0% / CO2 -1% (energy correct) but SAP +32.2 — a
pure cost-side bug. Space rate 7.50 -> 11.09 p/kWh; cert 2958 +32.2 ->
+14.7. The committed corpus gauge is unchanged (its 3 non-category-10
code-699 certs are all on Single meters -> STANDARD tariff, so this split
never applies to them); the win is on the unbiased /tmp population's
single worst cert.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-14 09:16:22 +00:00
Khalim Conn-Kowlessar
9ee3821138 fix(pv): zero exported PV when dwelling is not export-capable
SAP 10.2 Appendix M1 (PDF p.94): "EPV,ex,m = 0 if the PV system is not
connected to an export-capable meter." The cascade computed the β-split
export stream regardless of `is_dwelling_export_capable`, so a non-export-
capable dwelling was credited the full PV export — in the §10a COST it
credits at the Table 32 import rate (13.19 p/kWh), which dominates the rating.
On 7 Wybourn Terrace S2 5BJ the PE (144 vs lodged 151) and CO2 (27 vs 29)
already matched, yet the phantom export cost credit pulled SAP from ~73 to
92.1 (+19). Zero `epv_exported_monthly_kwh` after the Appendix-G4 diverter
adjustment when not export-capable; the onsite (EPV,dw) consumption and the
diverter HW reduction are unchanged.

Not-export-capable PV cohort (corpus, 4 certs): 7 Wybourn +19.1 -> +6.5,
4 Lime Ave +11.1 -> +0.4, 8 Hatherleigh +7.6 -> -0.2, Flat 5 ~-0.4. Gauge
66.1% -> 66.9%, MAE 1.124 -> 1.039. Floor 0.64 -> 0.65 / ceiling 1.18 -> 1.08.
Worksheet harness 47/47 0 diverge (Summary certs carry export-capable meters).
1 AAA test, pyright net-zero. Found by auditing the worst over-rater without a
worksheet: PE/CO2-match + cost-miss localised it to the PV export credit.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-14 08:48:38 +00:00
Khalim Conn-Kowlessar
94275d07cc fix(hot-water): default present-but-unsized cylinder to Table 28 Normal 110 L
RdSAP 10 §10.5 (PDF p.55): "If the actual size is not determined, the size of
a hot-water cylinder is taken as according to Table 28." When a cylinder is
present (has_hot_water_cylinder) but no size descriptor resolves — the gov API
lodges cylinder_size=0, or Exact with no measured volume — `_hot_water_
cylinder_volume_l` returned None, silently dropping BOTH the cylinder's
storage loss and the Table 13 electric-DHW high-rate fraction, under-costing
and over-rating the dwelling. Default such cylinders to the Table 28 baseline
"Normal" 110 L (the value §10.7 also instantiates as the first-row default).

The context-dependent Inaccessible 210/160 values are deliberately NOT applied
here — they are tied to the explicit "Inaccessible" descriptor (code 5) the
assessor lodges, not to an unpopulated size field.

Scope: 7 of 301 cylinder certs in the corpus (2%). Correctness fix — closes a
real spec gap; marginal on the headline (within-0.5 66.1% unchanged, MAE
1.128 -> 1.124) because these certs' residual is dominated by a separate HW-
demand gap, not the cylinder. Worksheet harness 47/47 0 diverge (Summary certs
lodge a real size, so the fallback never fires). 1 AAA test, pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-14 08:20:34 +00:00
Khalim Conn-Kowlessar
bec62b9167 fix(storage-heaters): Table 12a code-408 integrated-storage high-rate fraction
SAP 10.2 Table 12a Grid 1 (PDF p.191): electric storage heater SAP code 408
is an "Integrated (storage + direct-acting) system" with a 0.20 space-heating
high-rate fraction on a 7-hour tariff — NOT the 0.00 of "other storage
heaters". `_table_12a_system_for_main` returned None for all storage codes (an
explicit TODO), so code 408 fell back to the 100%-low-rate path and billed
space heating at the bare 7-hour low rate (5.50 p/kWh) — under-costing →
over-rating. Mapped cat-7 storage: 408 -> INTEGRATED_STORAGE_DIRECT (0.20),
others -> OTHER_STORAGE_HEATERS (0.00, unchanged behaviour). The enum +
fraction rows already existed; this only wires the dispatch, so the split
flows self-consistently to both the §10a cost and the Appendix-M1 D_PV
high-rate fraction.

Corpus: sap408 over-raters +14.6/+12.9/+12.7 -> +7.1/+5.1/+3.4 (two crossed
into within-0.5). Gauge 65.9% -> 66.1%, MAE 1.160 -> 1.128. Floor 0.63 -> 0.64
/ MAE ceiling 1.22 -> 1.18. Worksheet harness 47/47 0 diverge. The residual
+3..+7 is the "all other uses" 0.90 high-rate fraction (lighting/pumps/HW
still billed 100%-low on the off-peak legacy path) — the next slice.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-14 02:12:39 +00:00
Khalim Conn-Kowlessar
dfcd7af57c fix(heat-network): apply Table 4c(3) flat-rate charging factor to demand
SAP 10.2 Table 4c(3) (PDF p.169) "Factor for controls and charging method"
multiplies a heat network's heat requirement by 1.05-1.10 for FLAT-RATE
charging (note d: household pays a fixed amount regardless of heat used, so
no incentive to economise), and by 1.0 for charging linked to use. The
worksheet folds it into the heat-network requirement alongside the Table 12c
distribution loss factor:
  (307) space = (98c) x (302) x (305) x (306)
  (310) DHW   = (64)  x (305a) x (306)
Our cascade applied (306) DLF but never (305)/(305a), so every flat-rate
community-heating cert under-counted demand -> over-rated SAP.

Folded the factor into the 1/DLF efficiency override at the space-heating
(206) and DHW (water-inherits-from-main) sites. Space column adds +0.05 for
no thermostatic control (2301/2302); DHW column is 1.05 flat-rate / 1.0
linked-to-use.

Corpus (RdSAP-21.0.1, 1000 certs): community cluster median +0.32 -> -0.19,
within-0.5 38% -> 62% (control 2307 +0.83 -> -0.19; 2306 unchanged at factor
1.0 as spec requires). Overall gauge 65.0% -> 65.9%, MAE 1.174 -> 1.160.
Ratcheted the corpus-test floor 0.62 -> 0.63 / MAE ceiling 1.25 -> 1.22.

Also records (corpus-test comment + scripts/decompose_co2_pe_error.py) the
disproof of the prior "CO2/PE +5% is a factor/scope bug" lead: factors are
spec-exact, scope identical, and the bias is per-cert demand fidelity
(corr(SAP-err, PE-diff) = -0.54), not a one-slice factor fix.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-14 01:54:51 +00:00
Khalim Conn-Kowlessar
5317175dd3 fix(water-heating): count electric showers in Noutlets for mixer demand (App J)
The mixer-shower hot-water demand (worksheet 42a) divided N_shower by the
count of MIXER outlets only. But SAP 10.2 Appendix J step 1a is explicit:
"Establish how many shower outlets are present in the dwelling, Noutlets
(including in the count any instantaneous electric showers)" — and the
electric-shower step (64a) uses that same Noutlets from step 1a. So a
dwelling with both a mixer and an electric shower assigned the FULL N_shower
to the mixer system AND billed the electric shower on top of it, double-
counting shower demand → over-counted main HW → under-rated the dwelling.

Fix: thread the electric-shower count into the mixer demand so the
denominator is the total outlet count (mixer + electric), iterating the
warm-water draw over the mixer outlets only (per step 1e).

shower_types=1,2 cohort: -0.37 median -> +0.28 (crossed zero); API gauge
68.4% -> 69.0% within-0.5. Golden cert 0300-2747 (1 mixer + 1 electric)
re-pinned: PE +0.93 -> -0.10, CO2 +0.25 -> +0.15 (both toward zero,
confirming the double-count). Worksheet harness 47/47, 0 divergers (the
Elmhurst fixtures have no electric showers).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-13 23:31:02 +00:00
Khalim Conn-Kowlessar
4fb9b853dc fix(ventilation): apply Table 4g note 3 in-use factor to index-less MEV SFP
The no-PCDB MEV fan-electricity path fed the SAP 10.2 Table 4g default SFP
(0.8 W/(l/s)) directly as SFPav. But Table 4g note 3 (PDF p.176) is explicit:
the default SFP values "are to be multiplied by the appropriate in-use factor
for default data from the PCDB" — PCDB Table 329 system_type 10 ("default
data, used when SFP is taken from Table 4g rather than the PCDB"), IUF 2.5
(duct-agnostic per note 2). Table 4h, which previously held these factors, is
retired ("no longer used – data now stored in the PCDB").

Omitting the IUF under-billed the index-less MEV fan electricity by 2.5x
(SFPav 0.8 instead of 0.8 x 2.5 = 2.0), so cost was too low and the cohort
over-rated. This is distinct from the with-index path, which already applies
the tested-product system_type-2 "no scheme" IUF (~1.45) per fan.

Index-less gas-house MEV cohort: +1.37 median -> -0.18 (12% -> 92% within 0.5),
no overshoot — the missing IUF was exactly the over-rate. API gauge 67.7% ->
68.4% within-0.5 (mean|err| 0.992 -> 0.986, signed +0.031 -> +0.006).
Worksheet harness 47/47, 0 divergers (Summary-path MEV certs carry a PCDB
index or are natural, so unaffected).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-13 23:15:32 +00:00
Khalim Conn-Kowlessar
5b2cf5edc7 Merge remote-tracking branch 'origin/main' into feature/per-cert-mapper-validation
# Conflicts:
#	datatypes/epc/domain/epc_property_data.py
#	datatypes/epc/domain/mapper.py
#	datatypes/epc/domain/tests/test_from_rdsap_schema.py
2026-06-13 22:20:15 +00:00
Khalim Conn-Kowlessar
6884ec9fda fix(fabric): honour the gov-EPC lodged per-element U-values (RdSAP §5.1)
The gov-EPC API surfaces the assessor's RdSAP-assessed per-element U-values
as `roof_u_value` / `wall_u_value` / `floor_u_value` on each building part.
These were undeclared on the RdSAP 21.0.0/21.0.1 schemas, so `from_dict`
silently dropped them, and `heat_transmission` re-derived each U from the §5.6
/§5.7/§5.11 construction-default cascade. The gov OPEN data routinely redacts
the backing insulation thickness, so that re-derivation mis-bills an insulated
element as uninsulated.

RdSAP 10 §5.1: a known element U-value (documentary evidence / the lodged
RdSAP output) is used directly in place of the construction-default cascade.
Per [[project_per_cert_mapper_validation_state]] the gov API carries RdSAP
OUTPUT, so the lodged U reproduces the official's element heat loss exactly.

Worst case in the 2026 sample: cert 7921-0052-0940-5007-0663, an age-C
"Pitched, sloping ceiling" (rc=8) top-floor flat lodging roof_u_value=0.2 with
no thickness. The cascade returned the uninsulated 2.30 W/m²K → SAP 56.9 vs
lodged 80 (-23.09, the single largest error in the sample). The roof override
alone recovers ~15 SAP; the wall override (lodged 0.34 vs cascade) closes the
rest of this cohort.

Override applies to the MAIN wall only (alt-wall sub-areas keep their own
per-area U) and the part's floor=0. Fires only when the rare field is present
(9 of 909 computed certs), so the Summary path — which never lodges these
API fields — is untouched.

API gauge: 67.1% → 67.7% within-0.5, mean|err| 1.024 → 0.992.
Worksheet harness: 47/47, 0 divergers (unchanged).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 13:51:26 +00:00
Khalim Conn-Kowlessar
42e0bb3122 fix(thermal-mass): gov-API system built (wall code 8) is masonry, not park home
The §5.16 Table 22 thermal-mass-parameter (TMP) "always low-mass" set was
{timber 5, cob 7, park home 8}. But wall_construction code 8 is OVERLOADED by
the same gov-API/calc code-space divergence as the wall-U fix: the Summary
path's "PH" mapping uses 8 for park home, while the gov-EPC API enum uses 8
for SYSTEM BUILD (Summary system build = code 6). So every API system-built
cert was mis-rated as low-mass 100 kJ/m²K instead of masonry 250 (Table 22
lists system build as masonry — PDF p.48, line "System build 250...").

A too-low TMP shortens the §7 time constant tau = Cm/(3.6·H), over-cutting
the temperature reduction so mean internal temperature is UNDER-stated →
space-heating demand under-stated → SAP over-rated. This was the cause of the
uninsulated system-built over-rate cluster (n=9 gas-boiler certs at signed
+2.39 vs cavity +0.43 / solid-brick +0.08 at the same bands — a system-built-
specific anomaly with a spec-correct wall U).

Fix: drop 8 from the always-low set and gate it on `property_type` — code 8 is
the low-mass park-home value only when the dwelling really is a park home,
otherwise it is gov-API system build and keeps masonry 250. Disambiguated by
the same `property_type == "park home"` signal used elsewhere in the cascade.

Worksheet harness UNAFFECTED (47/47, 0 divergers): the Summary path uses code
6 for system build and code 8 only for genuine park homes (which stay
low-mass via the property_type gate). API gauge 65.3% -> 67.1% within-0.5
(mean|err| 1.059 -> 1.024, signed +0.050 -> -0.002). The uninsulated
system-built cluster collapses +2.82 -> +0.28 signed (0/11 -> 7/11 within
0.5). 2 AAA tests (parametrised code-8 system-built -> 250; park-home
property -> 100). pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 12:12:25 +00:00
Khalim Conn-Kowlessar
a97ff60b01 fix(water-heating): complete RdSAP Table 28 cylinder-size map (codes 5 + 6)
`_CYLINDER_SIZE_CODE_TO_LITRES` held only codes 2/3/4 (Normal/Medium/Large →
110/160/210 L); codes 5 (Inaccessible) and 6 (Exact) fell through to None,
so the Table-13 high-rate fraction AND the cylinder storage loss were skipped
for those certs (20 code-6 certs in the API sample).

Per RdSAP 10 Specification (10-06-2025) §10.5 Table 28 (PDF p.55):
- Code 6 "Exact": use the lodged measured volume. The gov API carries it in
  `cylinder_size_measured` (e.g. 150 L) — now plumbed through the 21.0.0/21.0.1
  schema → mapper → `SapHeating.cylinder_volume_measured_l`.
- Code 5 "Inaccessible": 210 L if off-peak electric dual immersion, 160 L from
  a solid-fuel boiler, otherwise 110 L (n=0 in the current sample, but
  spec-complete).

New `_cylinder_volume_l_from_code` centralises Table 28 resolution and replaces
the three raw-dict call sites (`_hot_water_cylinder_volume_l`, the cylinder
storage-loss path, and the PCDB performance check) so all three honour codes
5/6 identically. `_cylinder_inaccessible_volume_l` applies the code-5 context
rule via the existing immersion/off-peak-meter/solid-fuel-boiler detectors.

Worksheet harness UNAFFECTED (47/47, 0 divergers): the Summary path lodges
neither code 5/6 nor a measured volume. API gauge: within-0.5 64.4% -> 65.1%
(mean|err| 1.085 -> 1.075) — the 20 code-6 certs now size their cylinder from
the measured volume. 4 AAA tests (code 6 measured; code 5 solid-fuel/default/
off-peak-dual-immersion). pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 10:02:39 +00:00
Khalim Conn-Kowlessar
781efd75c0 fix(heat-transmission): apply dry-lining Table 14 R=0.17 to the main wall
The main-wall `u_wall(...)` call dropped the `dry_lined` kwarg, so the RdSAP 10
§5.7/§5.8 (PDF p.40-41) Table 14 dry-lining adjustment — U_adj = 1/(1/U₀ +
0.17) for a dry-lined (incl. lath-and-plaster) uninsulated wall — was never
applied to any main wall, even when the cert lodged `wall_dry_lined=Y`. The
ALTERNATIVE-wall path already passes `dry_lined` (line 1367); this one-sided
omission billed every dry-lined main wall at the un-adjusted (too-high) U →
wall heat loss too high → SAP under-rated.

Per-cert: a solid-brick (construction 3) band-A 230 mm main wall computes
U₀=1.70; dry-lined it is 1/(1/1.70+0.17)=1.32 — we were 22% too high. Across
the API gov-EPC sample the dry-lined `wall_construction=3` (solid brick)
sub-cohort sat at 10% within-0.5 / signed -1.33.

Fix: pass `dry_lined=bool(part.wall_dry_lined)` to the main-wall `u_wall`
call, mirroring the alt-wall path. `part.wall_dry_lined` is already plumbed
(Optional[bool], None → False). The three dry-lining branches in `u_wall`
(stone §5.6, solid-brick-by-thickness §5.7, generic uninsulated bucket §5.8)
are all spec-correct and already worksheet-validated (the bucket-0 cavity
case against cert 7700 age-C → 1.20).

Worksheet harness UNAFFECTED (47/47, 0 divergers): the Elmhurst/Summary
extractor only captures dry-lining for ALTERNATIVE walls (Summary §7), never
the main wall, so `part.wall_dry_lined` stays None on that path — this is a
pure API-path improvement. API gauge: within-0.5 60.1% -> 64.4% (mean|err|
1.163 -> 1.085, signed -0.097 -> +0.049). Both affected buckets improved
with no overshoot: solid brick (wc=3) 50% -> 57% within-0.5; cavity (wc=4,
dry-lined via the §5.8 bucket-0 path) 68% -> 72%.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 09:43:50 +00:00
Khalim Conn-Kowlessar
450e33e15d fix(ventilation): corridor flat assumes a draught lobby, zeroing §2 (13)
A flat accessed via an unheated corridor/stairwell assumes a draught lobby
is present, so SAP 10.2 §2 line (13) = 0.0 rather than the 0.05 no-lobby
infiltration penalty. Per RdSAP 10 Specification (10-06-2025, p.30, "Draught
lobby"): "add infiltration 0.05 if draught lobby is not present, or use 0.0
if present. ... Flat or maisonette: Assume draught lobby if entrance door is
facing corridor (heated or unheated) or stairwell."

Signal: a SHELTERED alternative wall (the RdSAP §5.9 wall-to-unheated-corridor
surface) is the evidence that the flat's entrance faces a corridor — the same
evidence the corridor door (Table 26 U=1.4) rides on. New helper
`_has_sheltered_corridor_wall` factors that check out of `_corridor_door_count`
and gates `_has_draught_lobby`. Houses and exposed-gable flats (no sheltered
alt wall) keep the lodged value / "assume no lobby if cannot be determined"
default, so the §2 cascade is unchanged for every non-corridor dwelling.

The cascade previously added the 0.05 penalty unconditionally, over-counting
(16)/(18)/(21) by 0.05 ACH. On simulated case 34 (cert 001431 storage flat)
this lifted effective air change (25)m from the worksheet's monthly 0.572-0.638
to 0.574-0.668, over-counting space-heating demand (98) by +46.3 kWh/yr
(+0.41%) -> SAP -0.18. Closing it lands (25)m exactly on the worksheet (avg
0.6024) and (98) at 11356.3 vs ws 11357.2:

  case 34 SAP 35.1325 -> 35.3130 vs ws 35.3094  (Δ -0.1769 -> +0.0036)

Guard-rails held (both improved): worksheet harness 47/47, 0 divergers (the
other corridor flat, cert 2474, -0.32 -> -0.02); API gauge 60.0% -> 60.1%
within 0.5, mean|err| 1.167 -> 1.163.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 09:00:54 +00:00
Khalim Conn-Kowlessar
c10881ae7a feat(heat-transmission): door to unheated corridor uses Table 26 U=1.4 on the sheltered wall
A door opening to an unheated corridor/stairwell takes U=1.4 W/m²K (RdSAP 10
Table 26, p.51 — any age band) instead of the 3.0 external-door default, and
its area deducts from the SHELTERED wall, not the main wall (RdSAP §3.7,
p.18: "the door of a flat/maisonette to an unheated stairwell or corridor
... is deducted from the sheltered wall area"). The cascade previously
billed every door at the external U on the main wall.

Signal: a SHELTERED alternative wall (`is_sheltered`, the RdSAP §5.9
wall-to-unheated-corridor surface, already modelled) is the evidence that
the dwelling is accessed via an unheated corridor, so one lodged door opens
to it. `_corridor_door_count` returns 1 when a sheltered alt wall is present
and >=1 door is lodged, else 0 — so the door channel is unchanged for every
non-corridor dwelling (houses, exposed-gable flats). `heat_transmission_
from_cert` gains a `corridor_door_count` param (default 0): it splits the
door area into external (main wall, age-default U) + corridor (sheltered
alt wall, U=1.4), threading the corridor door's area into that wall's
opening deduction and billing it at 1.4.

Validated on TWO faithful worksheets: simulated case 34 (cert 001431
storage flat — doors 8.14 exact, fabric 207.47 ≈ ws 207.48) and the
long-standing worksheet-harness diverger cert 2474 (−0.87 → −0.32, the
"space-demand thread" was the dropped corridor door). The worksheet harness
is now 47/47 with ZERO divergers.

API SAP gauge: 57.6% → 60.0% within 0.5; mean|err| 1.185 → 1.167; signed
−0.165 → −0.115 — ~22 sheltered-corridor flats were a systematic gap.
Regression gate green (3 pre-existing fails unrelated); pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 08:03:06 +00:00