The existing golden test compares calc PE/CO2 against the integer-rounded
lodged register values (energy_consumption_current / co2_emissions_current),
which conflates real calculator gaps with register rounding. This adds a
parallel pin against each cert's Elmhurst dr87 worksheet (286)/(272) at full
precision — a clean calculator-vs-Elmhurst signal for the 47 worksheet-backed
certs (9 ASHP + 38 cohort-2).
Findings at capture (calc − worksheet, on the worksheet's own decimal TFA):
- 37/47 exact on both PE (<0.05 kWh/m²) and CO2 (<0.02 kg).
- 10 higher-consumption gas certs carry PE +0.5..+1.5 kWh/m² AND
CO2 -0.5..-1.1 kg simultaneously. PE-over + CO2-under on the same
certs is the fingerprint of a small gas→electricity fuel-split
difference (elec PE 1.51 > gas 1.13, but elec CO2 0.136 < gas 0.21),
not a factor-value error — next slice candidate.
An earlier "41/47 PE gaps" reading was a JSON-integer-TFA division artifact;
comparing on the worksheet's decimal TFA (which the calculator also uses)
collapses it to the real 10. Worksheet values frozen as literals (the dr87
PDFs are untracked, so not parsed at test time) per the worksheet_unrounded_sap
convention. Also replaced a pre-existing pytest.approx with abs-diff to keep
the file at zero pyright errors (feedback_abs_diff_over_pytest_approx).
106 passed (was 59); pyright 0 errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 worksheet block 12b/13b (367)/(467) for a community heating
electric heat pump (Table 4a code 304 → Table 12 fuel 41 "heat from
electric heat pump"). The HP meters grid electricity, so per Table 12
note (s)/(t) + block 12b/13b footnote (a) its emission/PE factor is the
MONTHLY Table 12d/12e cascade (fuel 41 = standard-electricity profile),
weighted by the network heat profile, then × 1/heat-source-eff (1/COP):
(367)/(467) = [(307)+(310)] / COP × Σ((307+310)_m × factor_m)/Σ(...)
Per-line walk of CH3 (the displayed (367) 0.1535 / (467) 1.5717 are PDF
artifacts; the (373)/(473) totals reconcile only with):
CO2 factor = 0.15040 (monthly Table 12d wtd) vs cascade annual 0.136
PE factor = 1.55692 (monthly Table 12e wtd) vs cascade annual 1.501
Pre-slice the cascade routed code 304 through the non-electric branch
(`_co2_factor_kg_per_kwh(main) × 1/COP` = annual × scaling). New
`_is_heat_network_electric_main` (heat-network main whose fuel has a
Table 12d monthly set — i.e. fuel 41) routes all four factor helpers
(main + HW, CO2 + PE) through the monthly cascade × 1/COP. Non-electric
heat networks (gas 51 / oil 53 / coal 54) have no monthly set → annual
path unchanged (CH1, CH6 untouched).
Closure (CH3 was already SAP+cost EXACT):
CH3 (HP/Elec) CO2 −75.32→+0.0000 (= [(307+310)/3]×(0.1504−0.136)),
PE −249.32→−0.0000 (× (1.5569−1.501)) — FULLY EXACT
Corpus now 40/41 EXACT on all four metrics. Only CH6 remains: its
worksheet lodges a manual DLF=1.0 ("two adjoining dwellings") absent
from the Summary PDF (byte-identical to CH4 bar fuel type) — an
architectural limit, not a cascade gap. 2226 pass + 1 skip + 0 fail
(tolerances 1e-4 all metrics); pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 worksheet block 12b (CO2) / 13b (PE) for community heating
"CHP and boilers" (SAP code 302). Per unit of network heat fuel
H = (307)+(310) the effective generation factor is:
chp×100/(362)×f_fuel − chp×(361)/(362)×f_disp + (1−chp)×100/(367)×f_fuel
(363)/(463) CHP fuel = chp_frac × 100/heat_eff × f_fuel
(364)/(464) less credit = −chp_frac × elec_eff/heat_eff × f_disp
(368)/(468) boiler fuel = (1−chp_frac) × 100/boiler_eff × f_fuel
f_fuel = Table 12 heat-network fuel factor (the CHP unit and the back-up
boilers burn the same community fuel — verified vs CH2 gas / CH4 oil /
CH6 coal worksheets (363)/(368)); f_disp = Table 12f (PDF p.196) credit
for the CHP-generated electricity. RdSAP 10 §C (p.58) defaults: heat eff
50% (362), electrical eff 25% (361), boiler eff 80% (367); CHP heat frac
0.35 per-cert via community_heating_chp_fraction.
New `_heat_network_code_302_effective_factor` + Table 12f flexible
constants (0.420 CO2 / 2.369 PE) + RdSAP §C efficiency constants, wired
into all four factor helpers (main + HW, CO2 + PE) ahead of the existing
single-fuel / 1-over-heat-source-eff path. The worksheet (368)/(468)
boiler emissions DISPLAY rounded/mis-aligned in the PDF, but the
(373)/(473)/(386)/(486) totals reconcile only with the boiler at the
full Table 12 factor — verified EXACT.
Two spec citations applied:
- Table 12f flexible-operation default for RdSAP community CHP is an
Elmhurst engine choice (Table 12f notes make "standard" the default);
mirrored per [[feedback-software-no-special-handling]] and documented
in SAP_CALCULATOR.md §8.3.
- Table 12 heat-network oil/biodiesel CO2 (codes 53/56) corrected
0.298 → 0.335 per Table 12 (p.189) "assumes 'gas oil'"; the code-302
oil cascade (CH4) was the first to exercise it. PE 1.180 was already
correct. No other variant uses these codes (no regression).
Closures (CO2 + PE only — the CHP credit does not touch cost/SAP):
CH2 (CHP/Gas) CO2 −1411.49→+0.0000, PE +1331.23→+0.0000 EXACT
CH4 (CHP/Oil) CO2 −4378.24→−0.0000, PE +319.81→−0.0000 EXACT
CH6 (CHP/Coal) CO2/PE re-pinned (+2411.54 / +5023.48) — its worksheet
lodges a manual DLF=1.0 the Summary doesn't carry, so
cascade DLF=1.45 over-scales H; same root as the CH6
SAP −7.49 / cost +£172 (separate DLF front).
CH2/CH4 are now CO2+PE-exact but still carry the heat-network cost/SAP
residual (+0.5277 SAP / −£12.16 cost, exposed by S0380.175 — cost-side,
untouched here). CH3 unchanged (code 304 community-HP COP front).
Corpus state: 37 variants EXACT on all four metrics (incl. CH1);
remaining residuals are CH2/CH4 cost+SAP, CH3 CO2+PE (HP COP), CH6
all-metric (DLF quirk). 2223 pass + 1 skip + 0 fail (tolerances 1e-4 all
metrics per S0380.181); pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix C §C3.2 (PDF p.51), verbatim: "CO2 emissions and
Primary Energy associated with the electricity used for pumping water
through the distribution system are allowed for by adding electrical
energy equal to 1% of the energy required for space and water heating."
Worksheet line (313) = 0.01 × [(307)+(310)]; its CO2 (372) and PE (472)
bill on the Table 12d/12e monthly factors for fuel code 50 ("electricity
for pumping in distribution network"), weighted by the monthly heat
profile per worksheet footnote (a). (307)m/(310)m = (space_demand +
hw_output) / efficiency (the cascade models a heat network's generator
efficiency as 1/DLF).
This un-defers the (372)/(472) front the post-S0380.179 handover flagged
"don't guess until the factor source is identified": the source is
§C3.2 + Table 12d/12e code 50, NOT an empirical constant. The apparent
0.1994/0.2114 "factor" is an Elmhurst DISPLAY artifact — the worksheet
shows the (372) energy column as 0.01×(307) (space only) while computing
emissions on 0.01×(307+310) per the §C3.2 text. Verified EXACT line-by-
line against the CH2 corpus worksheet: (372)=23.6007 CO2 (rating),
(472)=208.2267 PE (demand).
New `_heat_network_distribution_electricity` helper (gated on
`_is_heat_network_main`) precomputes the energy + effective CO2/PE
factors; three new CalculatorInputs fields + calculator.py CO2/PE
summation terms (0.0/None → no-op for individually-heated certs).
Closures:
CH1 (Boilers/Gas) CO2 −23.60→−0.00, PE −208.23→+0.00 — FULLY EXACT
CH3 (HP/Elec) CO2 −98.92→−75.32, PE −457.54→−249.32 (distribution
component closed; code-304 community-HP COP remains)
CH2/CH4/CH6 gain their (372)/(472) component (CO2 +23.6, PE
+208.2); dominant CHP displaced-electricity credit
residual (Table 12f + block 12b/13b) is next slice.
No regression on the other 36 corpus variants (helper returns None off
heat-network mains) + golden + U985 fixtures. 2223 pass + 1 skip + 0
fail; pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The calculator tests lived under domain/sap10_calculator/{tests,worksheet/
tests,rdsap/tests,climate/tests,validation/tests}, none of which are in
pytest.ini testpaths — so CI (which collects tests/) never ran them. Relocate
all five dirs to tests/domain/sap10_calculator/{,worksheet,rdsap,climate,
validation}, mirroring the tests/domain/property_baseline/ convention, so the
cascade-pin / golden / e2e conformance suites run in CI.
Mechanics:
- git mv preserves history (110 files).
- Flattening the trailing /tests keeps each file's depth-to-repo-root
identical, so all 16 repo-root parents[4] fixture refs stay valid. Only
test_pcdb_etl.py's parents[1] (→ pcdb data) and one hardcoded absolute
golden-fixture path in test_cert_to_inputs.py needed rebasing.
- Cross-imports rewritten domain.sap10_calculator.worksheet.tests →
tests.domain.sap10_calculator.worksheet (21 files incl. the external
importer backend/documents_parser/tests/test_summary_pdf_mapper_chain.py).
- Golden-fixture path strings in test_summary_pdf_mapper_chain.py +
scripts/fetch_cohort2_api_jsons.py updated to the new location (the JSONs
moved with the rdsap tests).
load_cells / gitignored worksheet xlsx: the xlsx-pinned tests (test_dimensions
/ ventilation / water_heating) read 2026-05-19-17-18 RdSap10Worksheet.xlsx,
which is gitignored (.gitignore `*.xlsx`) and so absent in CI. _xlsx_loader.
load_cells now pytest.skip()s when the file is absent, so those tests run
locally and skip cleanly in CI instead of erroring — no new CI failures from
the move, and the gitignore policy is respected.
Verified: tests/domain/sap10_calculator + backend/documents_parser +
tests/domain/property_baseline = 2248 pass, 1 skipped; pyright resolves the
new import paths with zero import-resolution errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>