The 5th EpcSimulation overlay surface and the deepest applicator fold yet: a
heating bundle is a whole-system replacement, so _fold_heating routes its
absolute-target fields across main_heating_details[0] (fuel/emitter/control +
sap_main_heating_code OR index+category), sap_heating (water_heating_* +
cylinder), the top-level EpcPropertyData (has_hot_water_cylinder), and
sap_energy_source (meter_type, mains_gas). ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The fuel codes the calculator now puts on SapResult are its own codes — raw
gov-API enums or already-Table-32, depending on the source mapper (ADR-0015).
sap_code_to_fuel now runs the code through table_32.to_table_32_code
(promoted from private _to_table_32_code) — T32-first, then API-translate,
the SAME normalization the calculator's pricing/CO2 helpers use — before the
Table-32 -> Fuel dispatch, so the bill's carrier matches what the calculator
billed (incl. the API/T32 collision codes, e.g. 20 = wood-logs not heat-net).
Falls back to the raw code for billing fuels the price table omits (the 41-58
heat-network range), which resolve to HEAT_NETWORK -> UnpricedFuel — stricter
than, and intentionally divergent from, the calculator's lossy
default-to-mains-gas for an unpriced code (ADR-0014 §5).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0014 BillDerivation attributes each end-use (HEATING / HOT_WATER /
SECONDARY / APPLIANCES / COOKING) to a fuel carrier and credits PV
export. SapResult already carried the per-end-use kWh but not WHICH
fuel each end-use burns, nor the annual exported kWh — so a downstream
SapResult->EnergyBreakdown adapter could not pick the right tariff.
Surfaces five output-only fields, threaded exactly like the recently
merged appliances/cooking change (2f039aeb):
main_heating_fuel_code RdSAP10 Table 32 / SAP 10.2 Table 12 fuel
main_2_heating_fuel_code code column (the lodged fuel code, e.g.
secondary_heating_fuel_code mains gas 26). None when the corresponding
hot_water_fuel_code system is absent / fuel not resolvable.
pv_exported_kwh_per_yr SAP 10.2 Appendix M1 §3-4 annual export kWh
(0.0 when no PV).
cert_to_inputs.py populates the four fuel codes from the existing
resolvers the cost/CO2 cascade already uses — `_main_fuel_code`,
`_secondary_fuel_code`, `_water_heating_fuel_code` (not reinvented);
Main 2 is the second `main_heating_details` entry, guarded for length.
There is a single CalculatorInputs construction site (cert_to_demand_
inputs delegates to cert_to_inputs). `pv_exported_kwh_per_yr` already
existed on CalculatorInputs; SapResult collapses its Optional to 0.0.
HARD CONSTRAINT honoured — output-only, zero rating drift. These fields
do NOT feed ECF / total_fuel_cost_gbp / co2_kg_per_yr / primary_energy_*
/ sap_score / any monthly value. Every golden-fixture, Elmhurst e2e
SapResult pin, section cascade pin, and heating-corpus residual stays
byte-identical: calculator suite 1658 -> 1661 passed (+3 new tests),
4 skipped, 0 failed before and after. pyright net-zero (51 -> 51 in
domain/; no new errors in the touched test files).
New tests: a synthetic threading test (four fuel codes + PV export pass
unchanged through calculate_sap_from_inputs; None PV collapses to 0.0)
and a cert-level pin (mains-gas combi cert 000516 -> main fuel code 26,
no Main 2, secondary 30, HW 26). Synthetic CalculatorInputs / SapResult
fixtures updated for the new SapResult fields (defaults cover Inputs).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Designs the heating Recommendation Generator via /grill-with-docs. Load-bearing
decisions: HW + controls + fuel + meter fold into each competing whole-system
bundle (the legacy heating-vs-HW split double-counted); each bundle is a fixed,
real, contractor-installable end-state (ASHP via PCDB index, HHR storage via
sap_main_heating_code=409), Product stays cost-only; eligibility encodes only
physical/planning installability since the Optimiser owns the economics (the
legacy ASHP built-form / 120 m² rule is dropped — research found no
authoritative basis); the Simulation Overlay is the deepest surface yet,
spanning main_heating_details[0] + sap_heating + top-level EpcPropertyData +
sap_energy_source. Build order HHRSH -> ASHP -> boiler (deferred).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Modelling glazing overlay's draught-proofing recompute (RdSAP 10 §8.1 —
a count over openable windows + doors) needs every openable window captured
with its draught_proofed flag. cert 001431's §11 lodges 17 windows but only
14 surfaced, via two distinct gaps:
1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
laid out as a standalone keyword line with the U-value on the next line
and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
"<source> <U>" Manufacturer-line shape. Now anchored by a standalone
data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
the absent frame cell.
2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
(U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
backstop even though both are lodged on an "External wall". A window
lodged on a wall is vertical by definition; guard the U-value backstop so
it only fires when location/BP give no roof signal. The backstop's only
pinned cert (000516 W6) hand-builds its sap_roof_windows and so is
unaffected.
With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows, 14
draught-proofed — reconstructing Elmhurst's lodged 84% (16/19 = (14 windows
+ 2 doors) / (17 windows + 2 doors)). Full calculator + modelling +
orchestration suites green (1885 pass); the 2 glazing draught-proofing
xfails remain (the overlay recompute is the glazing agent's front).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the lighting generator (ADR-0023): run recommend_lighting in
_candidate_recommendations (no planning gate). Price low_energy_lighting in the
offline catalogue + contingency table (0.26, the legacy rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both. A run_modelling test pins
the wiring end-to-end (an incandescent-lit dwelling gets the LED upgrade in the
optimised package).
Downstream updates, all because lighting now fires on any cert with non-LED
bulbs: report.py gains the low_energy_lighting trigger (the non-LED counts); the
two golden-cert report tests and the multi-measure integration test now expect
low_energy_lighting alongside the fabric measures (the sample/golden EPCs lodge
low-energy-unknown bulbs); first-run integration seeds a low_energy_lighting
MaterialRow.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the lighting generator (ADR-0023): two real Elmhurst before/after
cascade pins, sourced from the low_energy_lighting recommendation folder. Both
close cleanly at 1e-4 with NO xfail — lighting changes only bulb counts →
Appendix L (232), no fabric coupling (contrast glazing's draught-proofing).
- zero existing LEDs: 20 incandescent → 20 LED
- some existing LEDs: 5 LED + 15 incandescent → 20 LED (partial-upgrade path)
The overlay-emits-correct-counts assertion lives in the Slice 2 unit tests.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of the lighting generator (ADR-0023): detect non-LED bulbs
(incandescent + CFL + low-energy-unknown > 0) and emit one "Lighting"
Recommendation whose single low_energy_lighting Option converts every bulb to
LED — the overlay sets led = total, the other three counts 0. Priced as a flat
per-bulb average x the non-LED count, contingency 0.26; the description names
"LED" while the measure_type stays MEASURE_MAP-aligned. None when already
all-LED or no bulb counts are lodged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the lighting generator (ADR-0023): the first whole-dwelling,
top-level overlay surface. LightingOverlay carries the four fixed-lighting
bulb-count fields by their exact EPC names (all Optional, absolute counts) +
EpcSimulation.lighting. The applicator's _fold_lighting writes the non-None
counts directly onto the result EpcPropertyData by name (setattr) — simpler
than ventilation's nested fold since the counts live top-level. Baseline
unmutated; pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Resolved in a grill-with-docs pass. recommend_lighting converts ALL non-LED
bulbs (incandescent + CFL + low-energy-unknown) to LED — all the way to LED, not
the legacy "fill to low energy", because SAP §12-1 rates LED efficacy (100)
above LEL (80) / CFL (55). A free Optimiser candidate (it improves SAP), unlike
ventilation's forced dependency. Its overlay is the first whole-dwelling,
top-level surface: a LightingOverlay carrying the four bulb-count fields by
their exact EPC names, folded directly onto EpcPropertyData (led=total, others
0). Priced per-bulb x non-LED count, contingency 0.26, measure_type
low_energy_lighting (MEASURE_MAP-aligned; "LED" in the description). Validation:
real before/after cascade pins (zero-existing-LEDs + some-existing-LEDs) at 1e-4,
clean (no fabric coupling). Ground-truth confirmed: 20 incandescent -> 20 LED
drops lighting (232) 783.7 -> 232.7 kWh/yr.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
With the mapper now in main, cert 001431 parses: it lodges four single-glazed
windows — codes 1 ("Single") and 15 ("single glazing, known data", a single
pane with manufacturer U/g). The generator only detected code 1, so it missed
two panes. Detect {1, 15}; set the secondary target to code 11 ("Secondary
glazing - Normal emissivity", what the cert re-lodges; score-neutral vs 7 but
exact).
A deterministic green pin proves the overlay reproduces the after's 14 windows
exactly. The full-SAP before->after pins are xfail(strict) tripwires: the
overlay nails the windows, but the measure also re-lodges percent_draughtproofed
84->100 (sealed units draught-proof the replaced openings) plus a ~0.4 SAP
fabric residual the overlay doesn't model yet — a glazing-measure coupling to
close later.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0019 warns that wall_construction code 8 is Park home (PH), NOT system-
built. It was already excluded (8 isn't in the constructable-options map), but
only implicitly. Add an explicit early-return + named constant so a park home
can never be mis-keyed as system-built, with a pin as the tripwire. A park
home's proprietary panel is never EWI/IWI-suitable.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`test_epc_property_data_round_trips[RdSAP-Schema-21.0.1]` failed with
`sap_roof_windows: None != []` — a normalization mismatch, not lost data.
The 21.0.1 fixture has no roof windows, but the 21.0.1 API mapper emitted
an empty list `[]` while the domain field defaults to None
(`Optional[List[SapRoofWindow]] = None`), the 21.0.0 path yields None, and
the persistence reload yields None (roof windows aren't stored yet — doc
§2.4). Append `or None` so "no roof windows" has one canonical
representation across mapper paths and the round-trip.
No data-loss change: a cert WITH roof windows still produces the
populated list (test_golden_fixtures pins a 6-roof-window cert), and the
§2.4 roof-window persistence gap remains separately tracked. Full
sap10_calculator + documents_parser + epc-repository suites pass (2420);
pyright unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the `_api_resolve_wall_insulation_thickness` tests
passed literals straight into the Act call. Bind them as named variables
in Arrange (`lodged_thickness`, `measured_value_mm`, `ni_lodgement`) and
have the asserts reference those names, so the Act line reads
declaratively and the inputs/expectations are stated once. Applied to all
three tests in the class. No behaviour change; tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the simplified room-in-roof branch used cryptic
locals. Rename for clarity (behaviour-unchanged; the geom dict keys and
the builder-function locals are untouched):
rr_a_rr -> rr_roof_area (the worksheet's simplified A_RR)
rr_common -> rr_common_wall_area
rr_gable -> rr_gable_area
a_rr_final -> rr_residual_roof_area (leftover roof-going area after
deducting perimeter walls/gables
/rooflights — takes the roof U)
Names now mirror the `rr_*_area_m2` geom keys they read from and say
"area of what". Added a one-line note that `rr_roof_area` is the RdSAP 10
§3.10.1 A_RR. Pyright unchanged; 1087 heat-transmission/cascade-pin tests
pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>