Commit graph

2402 commits

Author SHA1 Message Date
Khalim Conn-Kowlessar
fe3bf4eaed fix(ventilation): read Blower Door AP50 pressure test (Summary)
SAP 10.2 §2 (17)-(18): a measured/design air permeability at 50 Pa from a
Blower Door test routes infiltration via `(18) = AP50/20 + (8)`, in
preference to the components-based (16) estimate. The Elmhurst extractor
read only the AP4 ("Pulse") column of §12.2, so a Blower Door result
(§12.2 "Pressure Test Result (AP50)") fell through to the structural-
infiltration default — over-counting ventilation heat loss.

Surfaced by simulated case 44 (AP50 4.50): effective air change rate was
0.81 vs the worksheet's 0.58 (+38% ventilation loss). The cascade already
supports `air_permeability_ap50` (preferred over AP4); this wires the read
end to end (extractor → ElmhurstSiteNotes → SapVentilation → cert_to_inputs).

Pinned against the case-44 P960 §2 at abs=1e-4: (18) infiltration 0.3417
(= 4.5/20 + 0.1167) and (25) Jan effective ach 0.5812. Worksheet harness
stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 23:18:17 +00:00
Khalim Conn-Kowlessar
d4d2b222fc feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume)
Wire the non-separated conservatory into the §3 heat-transmission +
§1 dimensions cascade per RdSAP 10 §6.1 (PDF p.49) + Table 25 (p.51):

  "The floor area and volume of a non-separated conservatory are added to
   the total floor area and volume of the dwelling. Its roof area is taken
   as its floor area divided by cos(20°), and wall area is taken as the
   product of its exposed perimeter and its height. ... The conservatory
   walls and roof are taken as fully glazed ... Glazed walls are taken as
   windows, glazed roof as rooflight."

New `worksheet/conservatory.py` derives the geometry:
  - height from the equivalent storey count (§6.1: 1 storey → ground-floor
    room height; 1½ → ground + 0.25 + 0.5×first; etc.);
  - glazed WALL → window (27) at Table 25 U (double 3.1 / single 4.8) with
    the §3.2 curtain resistance (R=0.04) → U_eff 2.758;
  - glazed ROOF → rooflight (27a) at Table 25 roof U (double 3.4 / single
    5.3) + curtain → U_eff 2.993;
  - FLOOR → (28a) via BS EN ISO 13370 as an uninsulated SOLID ground floor
    with 300 mm walls (§5.12, spec p.43), exposed perimeter = glazed
    perimeter → U 0.89;
  - glazed wall + roof + floor areas join (31)/(36); the fully-glazed
    structure walls/roof add nothing (the glazing IS the window/rooflight).

`dimensions_from_cert` adds the conservatory floor area to TFA (4) and
floor area × height to volume (5) (feeds ventilation (8)), without making
it a storey (avg storey height for §2 infiltration is unchanged).

Pinned against the simulated case-44 P960 §3 at abs=1e-4 — every line ref
EXACT: (4) 95.3800, (5) 257.1630, (27) 96.1169, (27a) 38.2201, (28a)
21.4164, (29a) 35.5852, (30) 7.4688, (31) 294.2900, (33) 207.3274,
(36) 23.5432. The remaining whole-dwelling SAP/CO2 gap is the §6 solar
gains, closed in the next slice. Worksheet harness stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 15:59:26 +00:00
Khalim Conn-Kowlessar
fa131cca0b feat(conservatory): read §6.1 geometry through extractor + mapper
RdSAP 10 §6.1 (PDF p.49) models a non-separated (heated) conservatory as
part of the dwelling. Until now the Summary §5 block was reduced to an
inert `has_conservatory` bool and the geometry (floor area, glazed
perimeter, glazing, storey height) was dropped on both paths.

Plumbing only — no cascade consumer yet (Slices B/C/D wire §3/§6):
- ElmhurstSiteNotesExtractor reads the §5 Conservatory block into a new
  `Conservatory` site-notes record (scoped to §5 so the generic
  "Floor Area"/"Room Height" labels can't collide with §4 dimensions);
- domain gains a frozen `SapConservatory` (floor area, glazed perimeter,
  double/single glazing, thermally-separated guard, equivalent storey
  count) on `EpcPropertyData.sap_conservatory`;
- the Elmhurst mapper threads it through, dropping SEPARATED
  conservatories per §6.2 ("A separated conservatory ... is disregarded").

Verified against the simulated case-44 Summary (RefNo 001431): extracts
floor_area=12.0, glazed_perimeter=9.0, double_glazed=True, 1 storey.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 15:37:05 +00:00
Khalim Conn-Kowlessar
419e340477 test(worksheet): pin simulated case 43 at 1e-4 (RR + dry-line + mixed roof)
Golden regression fixture for the multi-feature dwelling that surfaced the
two Elmhurst-extractor bugs in a33707f8. case 43 is a 2-BP mid-terrace with
a DETAILED room-in-roof (two slopes, two flat ceilings, party + exposed
gables, two common walls), a MIXED-insulation multi-section roof (Main
insulated + Extension uninsulated 2.30), a DRY-LINED extension solid wall,
a mains-gas boiler (102 / control 2106) and a House-coal solid-fuel
secondary (633).

Routes the Summary PDF through the WHOLE extractor + mapper + calculator
pipeline (no hand-built EpcPropertyData) and pins the §3 fabric + SAP-rating
block at abs=1e-4: (29a) walls 74.5800, (30) roof 38.5008, (33) fabric
172.7844, continuous SAP 73.2332 = (258), CO2 3518.3037 = (272). Guards the
detailed-RR slope/common_wall surfaces, the dry-lining R=0.17 adjustment,
and the per-part mixed-roof billing together. Summary mirrored to
backend/documents_parser/tests/fixtures/Summary_001431_case43.pdf; provider
module mirrors the _case6/_case21 pattern, assertion in
test_section_cascade_pins. Harness 47/47; regression = the 3 pre-existing
fails; pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 08:26:05 +00:00
Khalim Conn-Kowlessar
a33707f851 fix(elmhurst): read main-wall dry-lining + fix last-RR-row U over-read
Two compensating Summary-extractor bugs surfaced by simulated case 43 (a
2-BP mid-terrace with a detailed room-in-roof + a dry-lined extension wall).
Their fabric errors nearly cancelled (walls net −0.76 W/K), hiding both
behind a deceptively small +0.05 SAP delta.

Bug 1 — main/extension wall dry-lining never read. The §7 "Dry-lining:
Yes/No" line was parsed only for ALTERNATIVE walls; the main/extension
WallDetails dropped it, so a dry-lined solid wall was billed at its
un-adjusted base U. RdSAP 10 §5.8 + Table 14: a dry-lined uninsulated wall
adds R=0.17 → U = 1/(1/U_base + 0.17). Case 43 Ext1: solid brick 1.70 →
1.32. Added `WallDetails.dry_lined`, read it in the extractor (both the
main-wall builder and the As-Main copy), threaded it to the domain
`wall_dry_lined` (emit None when undried — cascade-equivalent to False,
keeps the field absent for the non-dry-lined majority).

Bug 2 — the LAST room-in-roof surface row's U over-read. The per-row token
scan stops at the next RIR-row name; the final surface (no successor) over-
read into the following section, shifting the trailing-token slotting and
silently zeroing its `default_u` (case 43 Common Wall 2: 1.90 → 0.00 → the
2.4 m² common wall billed at U=0 instead of the main-wall 1.90). Stop the
scan at the row's natural end — the "Yes"/"No" u_value_known flag plus the
trailing u_value numeric.

Case 43 now reproduces the P960 EXACTLY: (29a) walls 74.5800, (33) fabric
172.7844, continuous SAP 73.2332 = (258), CO2 3518.30 = (272), all <1e-4
(was SAP +0.0455 / CO2 −8.04). Harness 47/47 0 raised; regression = the 3
pre-existing fails; pyright net-zero (51=51).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 07:51:33 +00:00
Khalim Conn-Kowlessar
5d556faf86 fix(roof): bill at-rafters insulation on RdSAP 10 Table 16/18 column (2)
`u_roof` only implemented the joist column, so roofs lodged insulated at
rafters (`roof_insulation_location == 1`) were mis-billed at the joist U
on both the API and Summary paths — under-stating loss, over-rating SAP.

RdSAP 10 §5.11.2 Table 16 (spec p.42-43) gives a distinct "insulation at
rafters" column (2): the rafter cavity is shallower than a loft void, so
the same depth yields a higher U (200 mm: rafters 0.29 vs joists 0.21).
§5.11 Table 18 (p.45) likewise carries a rafters column (2) for unknown /
as-built thickness (footnote (1): "The value from the table applies for
unknown and as built") — band A-D = 2.30, E = 1.50, F = 0.68, diverging
from the joist column's 100 mm-equivalent 0.40 default (footnote (4)).

- add `_ROOF_RAFTERS_BY_THICKNESS` (Table 16 col 2) + `_ROOF_RAFTERS_BY_AGE`
  (Table 18 col 2) to rdsap_uvalues; `u_roof` selects them via a new
  `insulation_at_rafters` flag (ignored for flat / sloping-ceiling roofs).
- `heat_transmission` derives the flag PER BUILDING PART from
  `roof_insulation_location` (gov-API int 1 / Summary "R Rafters"), which
  also fixes the multi-part dedup-roof-join problem: each part's own
  location now drives its U, replacing the unattributable joined
  `epc.roofs[]` description.

Worksheet-validated to 1e-4: simulated case 41 (4-bp — Ext1 rafters 200mm
→ 0.29, Ext3 rafters As-Built band F → 0.68; roof total 24.8350) and case
42 (6 variants — rafters 50mm → 0.88, rafters unknown band C → 2.30,
joists/none unchanged). Case 40 stays exact (roof 35.340, total 441.1606);
worksheet harness 47/47.

Corpus within-0.5 66.9% → 66.5% (gates 0.65/1.08 hold) — a spec-correct
shift, NOT a regression: all 15 corpus rafter certs carry redacted (None)
thickness yet lodge roof EER 2-4 (insulated), so the open API blanked a
specified thickness and the spec's unknown-rafter 2.30 default correctly
over-states them. Recovery needs a roof-EER→thickness inference on the
API path (follow-up), not a change to the U-table.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 04:42:44 +00:00
Khalim Conn-Kowlessar
b2b6f8e954 fix(mapper): map Elmhurst "Value known" cylinder to measured volume (code 6)
The Elmhurst Summary §15.1 lodges "Cylinder Size: Value known" with the
measured volume in the "Cylinder Volume (l)" line — the Summary-path
equivalent of the gov-API "Exact" descriptor. The mapper had no entry for
"Value known" so `_elmhurst_cylinder_size_code` raised UnmappedElmhurstLabel,
and even once mapped the measured volume was never threaded through, so the
cascade dropped the cylinder storage loss (~468 kWh/yr) from (219) water
heating on every measured-volume-cylinder Summary.

Per RdSAP 10 §10.5 Table 28 (p.55) a measured cylinder volume is used
directly. Map "Value known" → cascade code 6 (Exact) and thread the §15.1
"Cylinder Volume (l)" value into SapHeating.cylinder_volume_measured_l, which
`_cylinder_volume_l_from_code` (cert_to_inputs.py:5281) already reads for
code 6 — mirroring the gov-API path (mapper.py:1575/1885).

Pins simulated case 39 (P960-0001-001431): an age-A mid-terrace on direct-
acting electric room heaters (SAP code 691, cat 10, control 2602) with
electric-immersion DHW off a 117 L "Value known" cylinder. The full
extractor→mapper→calculator cascade now reproduces the worksheet's SAP-rating
block EXACTLY — SAP value 36.6365 (band F) and (272) CO2 2056.0731 kg/yr,
with (219) water heating 2637.5049 and (255) total energy cost 1802.0039.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-15 23:57:25 +00:00
Khalim Conn-Kowlessar
4fdc23f83d test(worksheet): pin simulated case 38 — mains-gas secondary reproduces worksheet exactly
The realistic re-generation of case 37 (code-117 gas boiler, control 2102,
+ a MAINS-GAS condensing gas-fire secondary code 611, vs case 37's biogas
605). The full extractor -> mapper -> calculator pipeline reproduces the
worksheet's SAP-rating block EXACTLY: continuous SAP 60.9152 (Δ 2e-5) and
(272) CO2 5801.0770 (Δ ~0). This confirms the boiler-efficiency /
control-2102 −5pp interlock / secondary-fuel handling are all correct, and
that case 37's +7 gap was purely the biogas sub-fuel the Summary export
cannot carry.

Summary mirrored into backend/documents_parser/tests/fixtures so the pin
runs without the unstaged workspace. PE not pinned — it is a separate
DPER block (different scope) already guarded by the corpus PE gauge.
Worksheet harness 47/47 unchanged; pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-15 13:31:36 +00:00
Khalim Conn-Kowlessar
5b2cf5edc7 Merge remote-tracking branch 'origin/main' into feature/per-cert-mapper-validation
# Conflicts:
#	datatypes/epc/domain/epc_property_data.py
#	datatypes/epc/domain/mapper.py
#	datatypes/epc/domain/tests/test_from_rdsap_schema.py
2026-06-13 22:20:15 +00:00
Jun-te Kim
1f40c3aeef fix engine dockerfile 2026-06-12 16:07:39 +00:00
Jun-te Kim
0159176772 python upgraded due to enum 2026-06-12 15:47:28 +00:00
Jun-te Kim
80ccec9b68 added floats helper 2026-06-12 14:28:41 +00:00
Jun-te Kim
a6123d762c Merge branch 'main' of https://github.com/Hestia-Homes/Model into feature/junte+khalim 2026-06-12 13:45:30 +00:00
Jun-te Kim
ff4a2e4242
Merge pull request #1198 from Hestia-Homes/feature/bill-derivation
Feature/bill derivation
2026-06-12 14:44:30 +01:00
Jun-te Kim
3995433816 Map RdSAP-Schema-17.0 certs to EpcPropertyData 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-12 12:40:04 +00:00
Jun-te Kim
5178197dc2 Map RdSAP-Schema-19.0 certs to EpcPropertyData 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-12 12:19:16 +00:00
Jun-te Kim
cfc337f04a Dispatch and map RdSAP-Schema-18.0 certs end-to-end 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-11 11:12:53 +00:00
Khalim Conn-Kowlessar
06989d6b0f fix(elmhurst-extractor): allocate single-glazed alt-wall windows to the alternative wall
The §11 layout parser keys a window's wall Location on the glazing-prefix /
orientation tokens around its data row. An alt-wall window lodges its
"Alternative wall 1" Location wrapped across the lines bracketing the W×H×A
row. For a DOUBLE-glazed alt window the prefix line also carries the glazing
phrase ("Double between 2002   Alternative wall"), so the partition breaks
there and the location survives into the window's pre-data slice. For a
SINGLE-glazed alt window the "Alternative wall" line stands alone with no
glazing-type word, so _partition_after_manuf scanned past it and swallowed
it into the PREVIOUS window's suffix — the window then defaulted to
"External wall" and its opening deducted from the wrong wall.

Fix: treat a standalone wall-location line ("Alternative wall" / "External
wall" / "Party wall") as a window boundary in _partition_after_manuf, so it
attaches to the following window's prefix. Surfaced by simulated case 34
(cert 001431 electric-storage flat): 2 of 4 single-glazed alt-wall windows
were mis-allocated, splitting 2.75/10.78 m² instead of the worksheet's
4.63/8.90 corridor/external opening areas.

Elmhurst-extractor only; API gauge unaffected. Regression gate green (3
pre-existing fails unrelated); worksheet harness 47/47 unchanged. Case 34's
alt-wall opening area now matches the worksheet; the corridor wall net area
is correct (the cert's residual is now isolated to the unheated-corridor
door, a separate slice).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:54:06 +00:00
Khalim Conn-Kowlessar
48b36d3d7e fix(elmhurst-mapper): carry §7 alternative-wall "Sheltered Wall" flag
The Elmhurst Summary §7 lodges "Alternative Wall N Sheltered Wall: Yes" for
a sub-area adjacent to an unheated buffer (e.g. a flat's corridor wall),
but the extractor dropped it and _map_elmhurst_alternative_wall never set
SapAlternativeWall.is_sheltered — so the cascade billed the sub-area at its
full exposed U instead of the RdSAP 10 Table 4 (p.22) sheltered U =
1/(1/U + 0.5).

The calculator already applies is_sheltered (_alt_wall_w_per_k) and the
gov-API path already wires sheltered_wall=="Y"; this brings the Elmhurst
front-end to parity. Three-part change: AlternativeWall.sheltered field +
_alternative_walls_from_lines parse ("Alternative Wall N Sheltered Wall") +
_map_elmhurst_alternative_wall is_sheltered=a.sheltered.

Surfaced by simulated case 34 (cert 001431 electric-storage flat): the
6.02 m² corridor wall billed at full U=1.50 (9.03 W/K) instead of the
sheltered 0.86 (5.18 W/K) — +3.85 W/K, -1.61 SAP. Post-fix the alt wall
matches the worksheet's (29a) 5.177 and case 34 closes from -1.61 to -0.30
(remaining residual is a separate window/wall area-allocation thread).

Elmhurst-mapper only: API SAP gauge unchanged (57.6% within 0.5); worksheet
harness 47/47 unaffected; regression gate green (3 pre-existing fails
unrelated); pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:35:46 +00:00
Khalim Conn-Kowlessar
f3dcd7b43e fix(elmhurst-mapper): single-storey flat with exposed roof is Top-floor, not Ground-floor
The Elmhurst dwelling-type classifier keyed "Top-floor flat" on a "dwelling
below" floor lodgement. A single-storey flat exposed BOTH top (a real
external roof) AND bottom (floor over partially-heated space, no dwelling
below) therefore fell through to "Ground-floor flat" — which the cascade's
_dwelling_exposure maps to has_exposed_roof=False, dropping the external
roof entirely.

Surfaced by simulated case 34 (cert 001431 reconfigured as a slimline
electric-storage flat): the worksheet bills (30) External roof = 39.98 m²
x U=2.30 = 91.95 W/K — the dominant heat-loss element — but the cascade
dropped it, under-stating space-heating demand by 42% (6550 vs 11357
kWh/yr) and over-predicting SAP by +21.76 (57.07 vs worksheet 35.31).

Fix: an exposed (non-party) roof puts the flat on the top storey
regardless of what is below it. Classify as "Top-floor flat" whenever the
roof is exposed; the flat's exposed floor is recovered downstream by the
existing per-BP is_above_partially_heated_space / is_exposed_floor override
in heat_transmission (§3). Party-roof flats ("another dwelling above") are
unaffected and stay Ground-/Mid-floor.

This is an Elmhurst-mapper (dwelling_type) bug, NOT a calculator bug: the
calculator correctly trusts dwelling_type, and the gov-API path supplies
the position directly (cert 0036 — a genuine ground-floor flat whose API
data lodges a "Pitched, no access" roof construction under another dwelling
— stays party, 2.51 W/K). API SAP gauge unchanged (57.6% within 0.5);
worksheet harness 47/47 unaffected; case 34 roof now exact (residual -1.61
is a separate flat-corridor wall-U thread). Regression gate green (3
pre-existing fails unrelated).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:23:56 +00:00
Khalim Conn-Kowlessar
b0a47cda05 fix(elmhurst-mapper): strip interleaved Alternative-wall fragments from glazing label
When a property lodges an Alternative Wall, pdftotext interleaves the §11
"Location" column ("Alternative wall 1") into the wrapped glazing-TYPE cell,
producing labels like "Double between 2002 Alternative wall and 2021 1
Alternative wall" (cert 001431 storage-heater variants, simulated case 34).

The existing greedy trailing-suffix strip (\s+Alternative wall.*$) truncates
at the FIRST "Alternative wall", losing "and 2021" and yielding the
unmatchable "Double between 2002". Added a fallback that removes EVERY
"<External|Alternative|Party> wall [n]" fragment and any stray 1-2 digit
location index from the raw label, then retries the lookup. Loss-free: no
glazing-type key contains a wall-location phrase or a bare 1-2 digit number
(install-date years are 4 digits).

Unblocks the Summary cascade for any property with an Alternative Wall;
Summary-path only (the API path receives structured glazing codes, so the
API gauge is unaffected). Regression gate green (1 pre-existing fail
unrelated).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:07:08 +00:00
Khalim Conn-Kowlessar
85d6f8468c feat(elmhurst-extractor): capture section 15.1 Immersion Heater (Dual/Single)
The Elmhurst Summary section 15.1 "Hot Water Cylinder" block lodges
"Immersion Heater: Dual" / "Single"; the extractor dropped it, so the
Summary path left immersion_heating_type = None while the API path already
captured it. Capturing it drives SAP Table 13's high-rate-fraction
DHW-cost split (RdSAP 10 section 10.5 p.54: 1 = dual, 2 = single) and
brings the two front-ends to parity.

Three-file change: WaterHeating.immersion_type field +
_extract_water_heating parse (scoped to the 15.1..15.2 slice) +
_elmhurst_immersion_type_code mapper (strict-raise on an unmapped label,
mirroring _elmhurst_cylinder_insulation_code).

Safe to land now that the preceding commit zeroes the high-rate fraction
for 18-/24-hour tariffs: the 20 solid-fuel corpus certs (solid fuel 4-11:
WHC 903 dual immersion, 18-hour meter, 110 L) carry a dual immersion, but
their 18-hour tariff bills 100% low-rate per Table 12a's 7-/10-hour scope
— so they stay EXACT instead of regressing to the 10-hour-column ~0.10.
7-/10-hour Summary immersion certs now correctly cost the Table 13
high-rate fraction instead of falling to the immersion=None 100%-low
default.

Regression gate green (3 pre-existing fails unrelated); API gauge
unchanged (Summary-path-only): 57.6% within 0.5, mean|err| 1.185.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 22:16:21 +00:00
Khalim Conn-Kowlessar
020ac6f220 fix(elmhurst-mapper): strip wrapped building-part fragment from glazing label
pdftotext can wrap the §11 building-part column onto the glazing-TYPE
token without an intervening glazing-gap descriptor, e.g. "Double between
2002 and 2021 1st" (the "1st" marks the 1st Extension). The existing
trailing-gap fallback only strips the fragment when preceded by "N mm";
the bare ordinal raised UnmappedElmhurstLabel.

New `_ELMHURST_GLAZING_LABEL_TRAILING_BP_RE` strips a trailing ordinal
("1st"/"2nd"/…) or "Main" and retries the lookup. No glazing-type key
ends in an ordinal or "Main", so it is loss-free. Surfaced by worksheet
`simulated case 33` (direct-acting electric boiler + immersion), which
previously could not be routed through the Summary cascade.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 21:25:42 +00:00
Daniel Roth
d571ccaee5 remove number of address2uprn tests 2026-06-10 16:26:54 +00:00
Daniel Roth
26d34c345c get last_submission_date from hubspot 2026-06-10 14:45:25 +00:00
Khalim Conn-Kowlessar
5a74897fed fix(water-heating): gate DHW separate-timing on programmer + boiler age (RdSAP 10 §10.5)
`_separately_timed_dhw` returned True for any boiler+cylinder+from-main
cert, applying the SAP 10.2 Table 2b note b) ×0.9 temperature-factor
reduction unconditionally. For the lpg-boiler "before" worksheet (pre-
1998 LPG boiler SAP code 115 + 210 L cylinder, NO cylinder thermostat,
control 2113 "Room thermostat and TRVs" — no programmer) this dropped
the (53) temperature factor to 0.702 (= 0.60 × 1.3 × 0.9) where the
worksheet lodges 0.78 (= 0.60 × 1.3), under-counting cylinder storage
loss (55) by ~119 kWh/yr and over-rating SAP by ~0.25.

RdSAP 10 §10.5 (PDF p.57) "Hot water separately timed":
    No programmer, pre-1998 boiler → No
    Programmer, pre-1998 boiler    → Yes
    Post-1998 boiler               → Yes
DHW is therefore NOT separately timed only when a pre-1998 boiler is
paired with a no-programmer control. Add the two SAP 10.2 Table 4c(2) /
Table 4b lookups (controls without a programmer = {2101, 2103, 2111,
2113}; pre-1998 gas/LPG boilers 110-119 + oil 124/125/128) and return
False for that combination; every other boiler+cylinder cert keeps the
separately-timed default, so the change is confined to old low-control
stock and the heating corpus + goldens are unchanged.

Effect: the full chain (Summary PDF → extractor → mapper → cert_to_inputs
→ calculator) now reproduces the lpg-boiler worksheet's §11a unrounded
SAP -6.6499 at abs < 1e-4 (was -6.4013). Full regression suite green bar
the 3 pre-existing unrelated fails.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 10:07:27 +00:00
Khalim Conn-Kowlessar
90de1fc976 fix(elmhurst-mapper): map "Bottled gas" main fuel to bottled LPG, not mains gas
An LPG-boiler dwelling on the Summary → from_elmhurst_site_notes path
mapped to main_fuel_type=26 (mains gas), making it indistinguishable
from a mains-gas boiler downstream — wrong Table 12/32 cost / CO2 / PE
(bottled LPG is ~10.30 p/kWh vs mains gas 3.48), and it defeats any
"non-gas → gas only with a mains-gas connection" gate (an LPG dwelling
looks already-gas).

Root cause: the recommendation worksheets lodge the boiler carrier as
§15.0 "Water Heating Fuel Type: Bottled gas" (§14.0 carries only SAP
code 115, a Table 4b gas-family row, + "Main gas: Yes" in §14.2 — a
mains-gas CONNECTION, not the heating fuel). "Bottled gas" was absent
from `_ELMHURST_MAIN_FUEL_TO_SAP10`, so the §15.0 fuel resolved to None
and `_elmhurst_gas_boiler_main_fuel` fell through priority-1 to the
mains-gas meter flag → 26.

Map "Bottled gas" → 3 (bottled LPG MAIN heating): code 3 routes via
`API_FUEL_TO_TABLE_32`/`API_FUEL_TO_TABLE_12` → Table-code 3 (10.30 /
9.46 p/kWh). NOT the legacy "LPG bottled": 5 entry — API code 5 =
anthracite, and `canonical_fuel_code` resolves the same-valued Table-32
code 5 to anthracite (3.64 p/kWh), so a 5 here mis-prices the dwelling
as cheap solid fuel (verified: a 5 mapping moved SAP the WRONG way,
42.33 → 45.11; code 3 moves it to -6.40 vs the worksheet's -6.6499).
Also add 3 to `_GAS_LPG_MAIN_FUEL_CODES` so the §15.0-lodged bottled-LPG
water fuel is adopted as the boiler's space-heating carrier (priority 1)
instead of the meter flag.

Effect: main_fuel_type=3 (bottled LPG) and water_heating_fuel=3 (was
None). Mains-gas certs still → 26 (full regression suite green bar the 3
pre-existing unrelated fails); the MissingMainFuelType tripwire still
fires for genuinely-undeterminable carriers.

Spec: SAP 10.2 Table 12 / RdSAP 10 Table 32 (PDF p.95) — bottled LPG
main heating fuel code 3.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:48:15 +00:00
Khalim Conn-Kowlessar
b473f6a1ec fix(elmhurst-mapper): classify top-floor flat from roof type, not room-in-roof
`_elmhurst_dwelling_type` derived a flat's roof exposure from
`room_in_roof is not None`, so a top-floor flat whose roof is a plain
external "PS Pitched, sloping ceiling" (no room-in-roof) fell through to
"Mid-floor flat". The cascade's `_dwelling_exposure` then treats a
mid-floor flat's roof as a party ceiling (RdSAP 10 §5 / §3 — party
surfaces carry no heat loss) and drops the entire roof term: cert
001431's 105 m² roof at U=2.3 = 241.68 W/K (30) vanished, collapsing
(33) fabric heat loss 320.06 → 78.38 and over-rating SAP by ~5 points
(on top of the age-band roof-U bug — see prior commit).

Read the roof TYPE instead — the dual of the floor's "Another dwelling
below" signal. A flat's roof is a party ceiling only when its Elmhurst
code is S / A / NR (Same/Another dwelling or Non-residential space
above); F / PN / PA / PS are exposed external roofs, so the dwelling is
on the top storey. `has_exposed_roof = room_in_roof present OR
_elmhurst_roof_is_exposed(roof)` — which is exactly what the function's
own docstring already described as the intent ("RR present or external
roof"), now implemented.

With both upstream fixes the full chain (Summary PDF → extractor →
mapper → cert_to_inputs → calculator) reproduces the worksheet's §11a
unrounded SAP 56.3649 at abs < 1e-4, with (30)/(33)/(37) matching to
the decimal. Only flat fixture reclassified; 000784 (top-floor, RR) and
000910 (ground-floor) unchanged. Regression suite green bar the 3
pre-existing unrelated fails.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:18:51 +00:00
Khalim Conn-Kowlessar
1033526812 fix(elmhurst-extractor): read Main Property age band from §3.0 Date Built block
The Elmhurst Summary §3.0 "Date Built" lodges the per-building-part age
bands; the Main row reads "Main Property" / "C 1930-1949". But "Main
Property" ALSO heads the §4.0 Dimensions table, so the global
`_str_val("Main Property")` collides with it: when pdftotext renders
"3.0 Date Built:" glued onto its "Main Property" row token on one
layout line (as the recommendation worksheets do), the first standalone
"Main Property" match is the §4 dimensions header — returning its next
token "Floor" as the "age band".

That garbage age propagated to `u_roof`: for a "Pitched, sloping
ceiling" (PS) roof with no lodged insulation thickness, `u_roof` returns
the spec uninsulated U=2.3 for the correct age C but U=0.4 for the
unparseable "Floor" — collapsing the roof heat-loss term and inflating
SAP by ~14 points on the affected cert.

Scope the read to the Date-Built block (between "3.0 Date Built" and
"4.0 Dimensions") and take the first age row — a line beginning with a
single A-M band letter + space ("C 1930-1949", "A before 1900",
"J 2003-2006"). Building-part name rows never start that way, and the
Main row precedes any extension / room-in-roof rows.

Regression: full sap10_calculator + documents_parser suite green bar the
3 pre-existing unrelated fails (2 stone-wall U tests, test_total_floor_
area); the multi-bp / "A before 1900" fixtures (000516, 001431_case*,
6035) keep their age bands.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:41:00 +00:00
Jun-te Kim
3b7d26fe34 added test for a 1000 examples 2026-06-09 16:02:21 +00:00
Daniel Roth
5178cd02c5 UploadedFile, FileTypeEnum, FileSourceEnum importable from infrastructure.postgres.uploaded_file_table 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-09 11:50:51 +00:00
Jun-te Kim
b48700e964 Merge branch 'main' into feature/junte+khalim 2026-06-08 16:56:15 +00:00
Jun-te Kim
0ccb0e0bf9
Merge pull request #1196 from Hestia-Homes/feautre/additional_properties_for_tracking
Feautre/additional properties for tracking
2026-06-08 16:19:34 +01:00
Jun-te Kim
a1b4bf4e98 added 4 deal proeprties 2026-06-08 14:42:06 +00:00
Khalim Conn-Kowlessar
24492aa4ba Merge origin/main into feature/bill-derivation (calculator + mapper fixes)
Pulls in 42 commits of calculator/mapper accuracy fixes from the per-cert
mapper-validation and floor/roof/heating fronts.

Conflict resolutions:
- mapper `_is_elmhurst_roof_window`: main dropped the branch's "wall location →
  vertical" guard (it broke cert 000516's rooflight), but that re-broke cert
  001431's two External-wall U>3.0 windows (which must stay vertical). The two
  certs lodge a BYTE-IDENTICAL §11 row, so neither location nor U separates
  them — the real discriminator is the room-in-roof context. Replaced the
  unconditional U>3.0 backstop with one gated on the BP having a room-in-roof
  (`_elmhurst_bp_has_room_in_roof`): 000516's Main BP has a "Room in roof type
  1" (→ rooflight), 001431's does not (→ vertical). Validated against BOTH —
  full Elmhurst worksheet suite 1038 pass + the 001431 window-extraction pin.
- property_postgres_repository: kept main's `ids_by_uprn` method + the branch's
  `_restrictions_of` helper.
- sap_fuel.py: the branch relocated it to domain/billing/ (already carrying
  main's to_table_32_code normalization), so kept the old path deleted.

Fallout from main's fabric fixes (validated by the boiler-3 real-cert pin which
still reproduces at delta 0):
- re-pinned the boiler-1 + boiler-instant-hw ASHP snapshot scores;
- main's §14.2 gas-boiler main-fuel derivation resolved the BGB/102 baseline
  gap, so `test_gas_boiler_instant_hw_before_baselines` is now a passing test
  (was an xfail tripwire).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 13:12:21 +00:00
Daniel Roth
bd4ad9022c Merge branch 'main' into feature/handle-new-magicplan-response-structure 2026-06-08 12:36:27 +00:00
KhalimCK
1b94da16d0
Merge pull request #1189 from Hestia-Homes/feature/per-cert-mapper-validation
Feature/per cert mapper validation
2026-06-08 13:19:58 +01:00
Daniel Roth
c22ee3821b Merge branch 'main' into feature/handle-new-magicplan-response-structure 2026-06-08 09:57:26 +00:00
Daniel Roth
41a40c9ba0 Fix Pylance unknowns in SQLModel table tests and correct pytest paths 2026-06-08 09:56:54 +00:00
Khalim Conn-Kowlessar
6b04514645 fix(mapper): resolve gas-boiler main fuel from §14.2 mains-gas meter
A Summary §14.0 Table 4b gas boiler (SAP code 101-119) lodges no §14.0
"Fuel Type" string in the newer Elmhurst export. The carrier was resolved
only from §15.0 "Water Heating Fuel Type" — fine when the same boiler
heats the water, but a gas boiler paired with a SEPARATE electric
immersion lodges §15.0 "Electricity", so `_elmhurst_gas_boiler_main_fuel`
returned None and the cascade strict-raised MissingMainFuelType.

Cert 001431 boiler-1/boiler-2 "before" variants are exactly this config:
§14.0 SAP code 102/104 (mains-gas boiler), §15.0 electric immersion
(code 909), §14.2 Meters "Main gas: Yes". The meter flag is the
authoritative carrier signal — a 101-119 boiler on mains gas burns mains
gas — so adopt it (SAP10 main_fuel 26 per _ELMHURST_MAIN_FUEL_TO_SAP10
"Mains gas") when §15.0 can't disambiguate. §15.0 gas/LPG still wins when
present (keeps LPG-vs-mains-gas precision); no mains-gas meter + non-gas
§15.0 still strict-raises rather than guessing.

Spec: SAP 10.2 Table 4b "Seasonal efficiency for gas and liquid fuel
boilers" (PDF p.168), rows 101-119. Both certs now resolve main_fuel=26
and compute (was: hard raise).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 17:48:04 +00:00
Khalim Conn-Kowlessar
27375d93a4 fix(u-value): solid brick as-built U by thickness — §5.7 Table 13
A 440 mm (>420 mm) solid brick AS-BUILT wall computed U = 1.70 (the
220 mm bucket default) instead of the RdSAP-correct 1.10. The §5.7
Table 13 thickness path only fired for *insulated* brick (external/
internal + thickness > 0); the as-built case fell through to the
Table 6 cavity/solid age-band default.

Spec: RdSAP 10 Specification (9th June 2025), §5.7 "U-values for
uninsulated brick walls, age bands A to E", Table 13 (PDF p.40):
  ≤200 mm → 2.5, 200–280 mm → 1.7, 280–420 mm → 1.4, >420 mm → 1.1.
Table 6 footnote (b) on the "Solid brick as built" row (PDF p.40):
"Or from 5.7 if wall thickness is other than 200mm to 280mm" — the
thickness table supersedes the flat 1.7 default whenever a documentary
wall thickness is lodged (200–280 mm gives 1.7 either way). The §5.8 /
Table 14 dry-lining R is added on top only when the wall is dry-lined,
per the §5.7 closing sentence.

Validated against the user-generated Elmhurst worksheet "simulated
case 21" (replica of API cert 2818-3053-3203-2655-9204: mid-terrace,
age band B, solid brick as-built 440 mm, room-in-roof). New §3 cascade
pin `test_section_3_wall_u_by_thickness_case21_match_pdf` routes the
Summary through the real extractor + mapper and pins:
  (31) 155.1000, (33) 175.6208, (36) 23.2650, (37) 198.8858 — all 1e-4.
External walls Main U → 1.1000; Sheltered RR gable → 1/(1/1.10+0.5) =
0.71 (was 0.92). Pinned on §3 only (case-6 precedent): its code-908
instantaneous multi-point gas water heater has a separate §4 (219) gap.

Cross-check: sim case 20 (220 mm) stays at 1.70 — unchanged.

API SAP accuracy (scripts/eval_api_sap_accuracy.py, 896 computed certs):
% |err| < 0.5 SAP vs lodged: 42.6% → 43.8%; mean |err| 2.045 → 2.010.

Regression: tests/domain/sap10_calculator/ (1861), backend/
documents_parser/tests/ (574), datatypes/epc/ + rdsap golden fixtures
all green (pre-existing test_total_floor_area excepted). pyright strict
net-zero. No solid-brick fixture pin shifted (200–280 mm unchanged).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 14:40:06 +00:00
Khalim Conn-Kowlessar
1ed6d06804 fix(mapper): drop only U=0 internal RR stud walls, keep positive-U ones
A Detailed room-in-roof lodges "Stud Wall" surfaces, but the cascade billed
every one through Table 17 from its insulation — over-counting fabric on
internal studs that carry no heat loss. sim case 20's two studs lodge §8.1
Default U-value 0.00 and the P960 worksheet omits them from BOTH fabric heat
loss (§3: (33)=285.9847) and total exposed area (31)=239.68; the cascade
computed ~0.52 each → (33) +4.16 W/K and continuous SAP 43.05 vs 43.6322.

Gate the drop on the lodged Default U-value: 0.00 → internal knee wall,
return None (no heat loss, no area); positive → a real exposed knee wall
(cert 000565 Ext2 Detailed: 0.31 / 0.10) that still falls through to the
Table-17 path. The earlier over-broad "drop all studs" zeroed 000565's
genuine studs — this keeps them.

Pins test_summary_001431_case20_fabric_heat_loss_matches_worksheet_line_33
((33)=285.9847 at 1e-4); case 20 continuous SAP now EXACT (43.6322). 2850
pass (the lone test_total_floor_area failure is pre-existing on base);
pyright strict net-zero (32=32).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 10:47:30 +00:00
Khalim Conn-Kowlessar
795d36b732 fix(extractor): re-join §11 windows whose Area cell split onto its own line
Sim case 20's §11 lodges 5 windows but only 1 surfaced. The "W H Area"
cells tokenize inconsistently: a narrow Area column keeps all three on one
line ("1.80 2.10 3.78" — matches _WIDTH_HEIGHT_AREA_RE), but a wider Area
column triggers pdftotext's 2+-space split, dropping the Area onto its own
line ("5.79 2.00" then "11.58"). The 3-decimal data anchor never matched
those four rows, so they were lost — gutting §6 solar gains (5 windows →
1) and dropping continuous SAP 43.05 → 38.32 vs the worksheet's 43.6322.

Pre-merge a "W H" line + a following lone-decimal Area into the canonical
"W H Area" line, gated on Area ≈ W × H (the §11 Area is always the product)
so a frame factor / g-value / U-value below a dimension line is never
absorbed. One-line layouts (3 decimals) are untouched.

Pins via test_summary_001431_case20_extracts_all_five_section11_windows
(Summary_001431_case20.pdf mirrors sap worksheets/golden fixture debugging/
simulated case 20/). 573 documents_parser tests pass; pyright strict net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 10:35:21 +00:00
Jun-te Kim
98297f803a
Merge pull request #1186 from Hestia-Homes/feature/landlord_data
fix
2026-06-05 20:03:55 +01:00
Jun-te Kim
e60ca6ee5d source of the problem in address2uprn 2026-06-05 19:03:33 +00:00
Khalim Conn-Kowlessar
efa10fe6cb S0380.239: system-build walls take masonry structural infiltration (0.35)
RdSAP 10 §2 (Ventilation, "Walls" row): "Structural infiltration: 0.25
for steel or timber frame or 0.35 for masonry construction ... System
build: treated as masonry." `_is_timber_or_steel_frame` wrongly included
wall_construction code 6 (system build) alongside code 5 (timber frame),
handing system-build dwellings the 0.25 structural ACH instead of 0.35.

On the cat-10 room-heater fixture (ref 001431, walls SY System Build →
code 6) this under-stated the infiltration rate (18) by exactly 0.10
(0.45 vs worksheet 0.55), dropping the effective air change (25), the
ventilation heat loss (38)m = 0.33 × (25)m × (5), and the heat-transfer
coefficient (39) — so space-heating demand (98) came out 404 kWh low
((211) 11158.6 vs worksheet 11563.2). Restrict the 0.25 branch to code 5
only; code 6 (and everything else) is masonry at 0.35.

Pins the rating-block (38)m ventilation heat loss mean = 83.3613 W/K at
abs 1e-4 and asserts the classifier treats the system-build wall as
masonry. §4 suite green (2415 passed, 1 skipped); no existing fixture
relied on system-build → 0.25.

Residual after this slice: SAP +0.03 / cost -£0.95 — a small fabric (33)
gap (-0.15 W/K) plus lighting (232) +1.0 kWh remain as separate causes.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 19:00:02 +00:00
Khalim Conn-Kowlessar
cbdee9ec3c S0380.238: single-point instantaneous water heaters incur no distribution loss
Water heating SAP code 909 (electric instantaneous) and 907 (single-point
gas) heat water at the point of use, serving one outlet with no
distribution pipework. Per SAP 10.2 §4 (p.23, l.1416): "'Single-point'
heaters, which are located at the point of use and serve only one outlet,
do not have distribution losses either." So worksheet (46)m = 0 and the
heat-required line collapses to SAP 10.2 worksheet l.7704
  (62)m = 0.85 × (45)m + (46)m + (57)m + (59)m + (61)m
        = 0.85 × (45)m   (all loss terms zero for a no-cylinder system).

`distribution_loss_monthly_kwh` already supported the
`is_instantaneous_at_point_of_use` flag (and its docstring already named
codes 907/909), but `water_heating_from_cert` hard-coded it to False, so
the cascade applied (46)m = 0.15 × (45)m to single-point heaters. That
0.15 distribution loss exactly cancelled the 0.85 reduction, leaving
(62)m = (45)m. On the cat-10 room-heater fixture (ref 001431, code 909)
that over-stated the water fuel (219) as 2082.6250 instead of the
worksheet's 1770.2313, and inflated the (65)m heat gains (692.47 vs
worksheet 442.55) which in turn suppressed space-heating demand.

Thread the cert's existing instantaneous flag (`_INSTANTANEOUS_WATER_CODES`
= {907, 909}) through `_water_heating_worksheet_and_gains` into both the
demand-pass and final `water_heating_from_cert` calls.

Pins (219) water fuel = 1770.2313 at abs 1e-4 via the extractor → mapper →
rating cascade. §4 suite green (2414 passed, 1 skipped); no existing
fixture exercised the 907/909 path. The residual space-heating fuel gap
((211) 11158.59 vs worksheet 11563.17) this exposes is a separate cause —
next slice.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 19:00:02 +00:00
Khalim Conn-Kowlessar
97f44b5364 fix(extractor): capture all 17 openable §11 windows on cert 001431
cert 001431's §11 lodges 17 windows but only 14 surfaced, via two distinct gaps:

1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
   data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
   laid out as a standalone keyword line with the U-value on the next line
   and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
   "<source> <U>" Manufacturer-line shape. Now anchored by a standalone
   data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
   the absent frame cell.

2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
   (U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
   backstop even though both are lodged on an "External wall". A window
   lodged on a wall is vertical by definition; guard the U-value backstop so
   it only fires when location/BP give no roof signal.

With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows.

Re-homed onto the mapper-validation line from feature/bill-derivation
(orig f68cea27); the modelling-only regression test
(tests/domain/modelling/test_window_extraction_001431.py) stays on
bill-derivation. KNOWN: the mapper guard breaks cert 000516's
test_summary_pdf_mapper_chain pins (W6 U=3.10 routing) — must be resolved
before this PRs to main.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 19:00:02 +00:00
Daniel Roth
198d2afdb1 Merge branch 'main' into feature/handle-new-magicplan-response-structure 2026-06-05 14:35:56 +00:00
Daniel Roth
8e349704b1 move magic plan handler to applications/ 2026-06-05 14:33:26 +00:00