Pulls in 42 commits of calculator/mapper accuracy fixes from the per-cert
mapper-validation and floor/roof/heating fronts.
Conflict resolutions:
- mapper `_is_elmhurst_roof_window`: main dropped the branch's "wall location →
vertical" guard (it broke cert 000516's rooflight), but that re-broke cert
001431's two External-wall U>3.0 windows (which must stay vertical). The two
certs lodge a BYTE-IDENTICAL §11 row, so neither location nor U separates
them — the real discriminator is the room-in-roof context. Replaced the
unconditional U>3.0 backstop with one gated on the BP having a room-in-roof
(`_elmhurst_bp_has_room_in_roof`): 000516's Main BP has a "Room in roof type
1" (→ rooflight), 001431's does not (→ vertical). Validated against BOTH —
full Elmhurst worksheet suite 1038 pass + the 001431 window-extraction pin.
- property_postgres_repository: kept main's `ids_by_uprn` method + the branch's
`_restrictions_of` helper.
- sap_fuel.py: the branch relocated it to domain/billing/ (already carrying
main's to_table_32_code normalization), so kept the old path deleted.
Fallout from main's fabric fixes (validated by the boiler-3 real-cert pin which
still reproduces at delta 0):
- re-pinned the boiler-1 + boiler-instant-hw ASHP snapshot scores;
- main's §14.2 gas-boiler main-fuel derivation resolved the BGB/102 baseline
gap, so `test_gas_boiler_instant_hw_before_baselines` is now a passing test
(was an xfail tripwire).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A Summary §14.0 Table 4b gas boiler (SAP code 101-119) lodges no §14.0
"Fuel Type" string in the newer Elmhurst export. The carrier was resolved
only from §15.0 "Water Heating Fuel Type" — fine when the same boiler
heats the water, but a gas boiler paired with a SEPARATE electric
immersion lodges §15.0 "Electricity", so `_elmhurst_gas_boiler_main_fuel`
returned None and the cascade strict-raised MissingMainFuelType.
Cert 001431 boiler-1/boiler-2 "before" variants are exactly this config:
§14.0 SAP code 102/104 (mains-gas boiler), §15.0 electric immersion
(code 909), §14.2 Meters "Main gas: Yes". The meter flag is the
authoritative carrier signal — a 101-119 boiler on mains gas burns mains
gas — so adopt it (SAP10 main_fuel 26 per _ELMHURST_MAIN_FUEL_TO_SAP10
"Mains gas") when §15.0 can't disambiguate. §15.0 gas/LPG still wins when
present (keeps LPG-vs-mains-gas precision); no mains-gas meter + non-gas
§15.0 still strict-raises rather than guessing.
Spec: SAP 10.2 Table 4b "Seasonal efficiency for gas and liquid fuel
boilers" (PDF p.168), rows 101-119. Both certs now resolve main_fuel=26
and compute (was: hard raise).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A 440 mm (>420 mm) solid brick AS-BUILT wall computed U = 1.70 (the
220 mm bucket default) instead of the RdSAP-correct 1.10. The §5.7
Table 13 thickness path only fired for *insulated* brick (external/
internal + thickness > 0); the as-built case fell through to the
Table 6 cavity/solid age-band default.
Spec: RdSAP 10 Specification (9th June 2025), §5.7 "U-values for
uninsulated brick walls, age bands A to E", Table 13 (PDF p.40):
≤200 mm → 2.5, 200–280 mm → 1.7, 280–420 mm → 1.4, >420 mm → 1.1.
Table 6 footnote (b) on the "Solid brick as built" row (PDF p.40):
"Or from 5.7 if wall thickness is other than 200mm to 280mm" — the
thickness table supersedes the flat 1.7 default whenever a documentary
wall thickness is lodged (200–280 mm gives 1.7 either way). The §5.8 /
Table 14 dry-lining R is added on top only when the wall is dry-lined,
per the §5.7 closing sentence.
Validated against the user-generated Elmhurst worksheet "simulated
case 21" (replica of API cert 2818-3053-3203-2655-9204: mid-terrace,
age band B, solid brick as-built 440 mm, room-in-roof). New §3 cascade
pin `test_section_3_wall_u_by_thickness_case21_match_pdf` routes the
Summary through the real extractor + mapper and pins:
(31) 155.1000, (33) 175.6208, (36) 23.2650, (37) 198.8858 — all 1e-4.
External walls Main U → 1.1000; Sheltered RR gable → 1/(1/1.10+0.5) =
0.71 (was 0.92). Pinned on §3 only (case-6 precedent): its code-908
instantaneous multi-point gas water heater has a separate §4 (219) gap.
Cross-check: sim case 20 (220 mm) stays at 1.70 — unchanged.
API SAP accuracy (scripts/eval_api_sap_accuracy.py, 896 computed certs):
% |err| < 0.5 SAP vs lodged: 42.6% → 43.8%; mean |err| 2.045 → 2.010.
Regression: tests/domain/sap10_calculator/ (1861), backend/
documents_parser/tests/ (574), datatypes/epc/ + rdsap golden fixtures
all green (pre-existing test_total_floor_area excepted). pyright strict
net-zero. No solid-brick fixture pin shifted (200–280 mm unchanged).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A Detailed room-in-roof lodges "Stud Wall" surfaces, but the cascade billed
every one through Table 17 from its insulation — over-counting fabric on
internal studs that carry no heat loss. sim case 20's two studs lodge §8.1
Default U-value 0.00 and the P960 worksheet omits them from BOTH fabric heat
loss (§3: (33)=285.9847) and total exposed area (31)=239.68; the cascade
computed ~0.52 each → (33) +4.16 W/K and continuous SAP 43.05 vs 43.6322.
Gate the drop on the lodged Default U-value: 0.00 → internal knee wall,
return None (no heat loss, no area); positive → a real exposed knee wall
(cert 000565 Ext2 Detailed: 0.31 / 0.10) that still falls through to the
Table-17 path. The earlier over-broad "drop all studs" zeroed 000565's
genuine studs — this keeps them.
Pins test_summary_001431_case20_fabric_heat_loss_matches_worksheet_line_33
((33)=285.9847 at 1e-4); case 20 continuous SAP now EXACT (43.6322). 2850
pass (the lone test_total_floor_area failure is pre-existing on base);
pyright strict net-zero (32=32).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Sim case 20's §11 lodges 5 windows but only 1 surfaced. The "W H Area"
cells tokenize inconsistently: a narrow Area column keeps all three on one
line ("1.80 2.10 3.78" — matches _WIDTH_HEIGHT_AREA_RE), but a wider Area
column triggers pdftotext's 2+-space split, dropping the Area onto its own
line ("5.79 2.00" then "11.58"). The 3-decimal data anchor never matched
those four rows, so they were lost — gutting §6 solar gains (5 windows →
1) and dropping continuous SAP 43.05 → 38.32 vs the worksheet's 43.6322.
Pre-merge a "W H" line + a following lone-decimal Area into the canonical
"W H Area" line, gated on Area ≈ W × H (the §11 Area is always the product)
so a frame factor / g-value / U-value below a dimension line is never
absorbed. One-line layouts (3 decimals) are untouched.
Pins via test_summary_001431_case20_extracts_all_five_section11_windows
(Summary_001431_case20.pdf mirrors sap worksheets/golden fixture debugging/
simulated case 20/). 573 documents_parser tests pass; pyright strict net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §2 (Ventilation, "Walls" row): "Structural infiltration: 0.25
for steel or timber frame or 0.35 for masonry construction ... System
build: treated as masonry." `_is_timber_or_steel_frame` wrongly included
wall_construction code 6 (system build) alongside code 5 (timber frame),
handing system-build dwellings the 0.25 structural ACH instead of 0.35.
On the cat-10 room-heater fixture (ref 001431, walls SY System Build →
code 6) this under-stated the infiltration rate (18) by exactly 0.10
(0.45 vs worksheet 0.55), dropping the effective air change (25), the
ventilation heat loss (38)m = 0.33 × (25)m × (5), and the heat-transfer
coefficient (39) — so space-heating demand (98) came out 404 kWh low
((211) 11158.6 vs worksheet 11563.2). Restrict the 0.25 branch to code 5
only; code 6 (and everything else) is masonry at 0.35.
Pins the rating-block (38)m ventilation heat loss mean = 83.3613 W/K at
abs 1e-4 and asserts the classifier treats the system-build wall as
masonry. §4 suite green (2415 passed, 1 skipped); no existing fixture
relied on system-build → 0.25.
Residual after this slice: SAP +0.03 / cost -£0.95 — a small fabric (33)
gap (-0.15 W/K) plus lighting (232) +1.0 kWh remain as separate causes.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Water heating SAP code 909 (electric instantaneous) and 907 (single-point
gas) heat water at the point of use, serving one outlet with no
distribution pipework. Per SAP 10.2 §4 (p.23, l.1416): "'Single-point'
heaters, which are located at the point of use and serve only one outlet,
do not have distribution losses either." So worksheet (46)m = 0 and the
heat-required line collapses to SAP 10.2 worksheet l.7704
(62)m = 0.85 × (45)m + (46)m + (57)m + (59)m + (61)m
= 0.85 × (45)m (all loss terms zero for a no-cylinder system).
`distribution_loss_monthly_kwh` already supported the
`is_instantaneous_at_point_of_use` flag (and its docstring already named
codes 907/909), but `water_heating_from_cert` hard-coded it to False, so
the cascade applied (46)m = 0.15 × (45)m to single-point heaters. That
0.15 distribution loss exactly cancelled the 0.85 reduction, leaving
(62)m = (45)m. On the cat-10 room-heater fixture (ref 001431, code 909)
that over-stated the water fuel (219) as 2082.6250 instead of the
worksheet's 1770.2313, and inflated the (65)m heat gains (692.47 vs
worksheet 442.55) which in turn suppressed space-heating demand.
Thread the cert's existing instantaneous flag (`_INSTANTANEOUS_WATER_CODES`
= {907, 909}) through `_water_heating_worksheet_and_gains` into both the
demand-pass and final `water_heating_from_cert` calls.
Pins (219) water fuel = 1770.2313 at abs 1e-4 via the extractor → mapper →
rating cascade. §4 suite green (2414 passed, 1 skipped); no existing
fixture exercised the 907/909 path. The residual space-heating fuel gap
((211) 11158.59 vs worksheet 11563.17) this exposes is a separate cause —
next slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
cert 001431's §11 lodges 17 windows but only 14 surfaced, via two distinct gaps:
1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
laid out as a standalone keyword line with the U-value on the next line
and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
"<source> <U>" Manufacturer-line shape. Now anchored by a standalone
data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
the absent frame cell.
2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
(U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
backstop even though both are lodged on an "External wall". A window
lodged on a wall is vertical by definition; guard the U-value backstop so
it only fires when location/BP give no roof signal.
With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows.
Re-homed onto the mapper-validation line from feature/bill-derivation
(orig f68cea27); the modelling-only regression test
(tests/domain/modelling/test_window_extraction_001431.py) stays on
bill-derivation. KNOWN: the mapper guard breaks cert 000516's
test_summary_pdf_mapper_chain pins (W6 U=3.10 routing) — must be resolved
before this PRs to main.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Modelling glazing overlay's draught-proofing recompute (RdSAP 10 §8.1 —
a count over openable windows + doors) needs every openable window captured
with its draught_proofed flag. cert 001431's §11 lodges 17 windows but only
14 surfaced, via two distinct gaps:
1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
laid out as a standalone keyword line with the U-value on the next line
and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
"<source> <U>" Manufacturer-line shape. Now anchored by a standalone
data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
the absent frame cell.
2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
(U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
backstop even though both are lodged on an "External wall". A window
lodged on a wall is vertical by definition; guard the U-value backstop so
it only fires when location/BP give no roof signal. The backstop's only
pinned cert (000516 W6) hand-builds its sap_roof_windows and so is
unaffected.
With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows, 14
draught-proofed — reconstructing Elmhurst's lodged 84% (16/19 = (14 windows
+ 2 doors) / (17 windows + 2 doors)). Full calculator + modelling +
orchestration suites green (1885 pass); the 2 glazing draught-proofing
xfails remain (the overlay recompute is the glazing agent's front).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): `_parse_thickness_mm` handles a None input and
returns Optional[int], so its call-return locals — and the Optional[str]
raws they read from `_local_val` — read clearer when annotated. Annotates
`thickness_raw`/`ins_thickness_raw: Optional[str]` and
`thickness_mm`/`insulation_thickness_mm: Optional[int]` at all four call
sites (_wall_details_from_lines, _alternative_walls_from_lines,
_roof_details_from_lines, _floor_details_from_lines), plus the adjacent
`u_val_raw`/`default_u` Optional pair in _floor_details_from_lines for
consistency. Matches the project convention of typehinting call-return
locals. No behaviour change; pyright clean, 569 parser tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes the secondary-glazing family. S0380.235 mapped the unknown-data
(7) and normal-emissivity (11) secondary variants; the RdSAP-21.0.1
`glazed_type` enum also defines code 12 "secondary glazing, low
emissivity", whose Elmhurst §11 label "Secondary glazing - Low
emissivity" was unmapped and would strict-raise. Cascade code 12 carries
the same daylight/solar bucket as 7/11 (g_L=0.80, g⊥=0.76); the lodged
manufacturer U/g drive §3/§6. With this the double family (codes 1/2/3/
7/13 via their Elmhurst phrasings) and the secondary family (4/11/12) are
fully covered. Coverage test extended.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §3.3: "As Main Wall: Yes" makes an extension inherit the main
dwelling's external wall CONSTRUCTION only — the party wall type is
lodged separately per building part in the Summary §7 block and may
differ. `_extract_extensions` was copying `main_walls.party_wall_type`
into the inherited WallDetails, so every extension reused the main's
party wall U.
On the double_glazing fixture (Summary_001431) the Main lodges party
"CU Cavity masonry unfilled" (SAP10 wall_construction 4 → u_party_wall
0.5) but the 1st Extension lodges "U Unable to determine" (→ 0 → RdSAP
default 0.25). Pre-fix both building parts used 0.5, inflating worksheet
(32) party-wall heat loss by 6.56 W/K (Ext1 26.25 m² × 0.25). After the
fix worksheet (32) is exact: ours 32.573 vs worksheet 32.5725.
Now reads the extension's own "Party Wall Type" from its §7 chunk,
falling back to the main's only when the extension lodges none. Adds a
fixture + test asserting Main=4 / Ext=0 with distinct u_party_wall.
Suite 2413 pass; no cohort regression.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The double_glazing recommendation fixture (Summary_001431) exercises every
RdSAP-21 §11 glazing lodging in one cert; five labels were missing from
`_ELMHURST_GLAZING_LABEL_TO_SAP10` and strict-raised `UnmappedElmhurstLabel`:
"Secondary glazing" -> 7 (Table 6b "secondary glazing", g_L 0.80)
"Secondary glazing - Normal emissivity" -> 11 (RdSAP-21 secondary normal-E, g_L 0.80)
"Triple pre 2002" -> 10 (triple pre-2002, g_L 0.70)
"Triple with unknown install date" -> 6 (generic triple glazed, g_L 0.70)
"Single glazing, known data" -> 15 (single known-data, g_L 0.90)
The glazing code's only cascade effect is the §5 (66)..(67) daylight factor
g_L in `_G_LIGHT_BY_GLAZING_CODE` (single 0.90 / double+secondary 0.80 /
triple 0.70); the lodged manufacturer U-value and solar_transmittance drive
§3 / §6 directly (`_g_perpendicular` prefers the lodged value). Codes are the
semantically-exact RdSAP-21 rows within the correct g_L bucket, kept distinct
for the strict-raise audit trail. Adds a full-coverage test over all 13
distinct labels. Suite 2413 pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix G4 (PDF p.72-73). A PV diverter routes surplus PV
generation (the would-be export EPV,m × (1 − βm)) to an immersion heater
in the hot-water cylinder. Per G4 step 4:
SPV,diverter,m = EPV,m × (1 − βm) × 0.8 × fPV,diverter,storageloss
(0.8 = cylinder heat-acceptance; fPV,diverter,storageloss = 0.9 for the
higher storage temperature), clamped to ≤ (62)m + (63a)m, and entered as
the negative worksheet (63b)m (step 5). The β factor is computed on the
PRE-diverter (219) per the §3a note (lines 5485-5486). Effects:
- (64)m = (62)m + (63b)m → less main-system water-heating fuel (219);
- export drops to EPV,ex,m = EPV,m(1 − βm) + (63b)m / 0.9 (§4 p.94
line 5501); the onsite dwelling portion EPV,m × βm is unchanged.
Inclusion (G4 step 1) requires ALL of: a PV system connected to the
dwelling; a cylinder larger than (43) average daily HW use; no solar
water heating; no battery — else the diverter is disregarded.
Three layers:
- extractor reads Summary §19 "Diverter present"; schema 21.0.0/21.0.1
SapEnergySource gains `pv_diverter` (API `sap_energy_source.pv_diverter`);
- `Renewables.pv_diverter_present` + domain `SapEnergySource.pv_diverter_present`,
set in both the Elmhurst and API mapper paths;
- `_pv_diverter_monthly_kwh` applies the G4 math after the β split;
`cert_to_inputs` recomputes (219) and the PV export.
On simulated case 19 (electric storage heaters, 7-hour, PV + diverter):
SAP continuous 50.33 → 51.34 (worksheet 51.2221; both round to the
lodged 51), cost (255) 1847.5 → 1812.3 (ws 1816.6), CO2 (272) 3331 →
3120 (ws 3126), with (233a) dwelling 1280.6 (ws 1280.4). The residual
+0.11 SAP is an upstream winter Appendix-M monthly-EPV-shape gap +
fabric (33) +1.0, tracked as the next case-19 cause. Suite: 2412 pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The gov-EPC API mapper sets BOTH roof_construction (int) and
roof_construction_type (str, derived via _API_ROOF_CONSTRUCTION_TO_STR),
but the Elmhurst mapper set only the string — leaving roof_construction
None on every site-notes cert. The SAP cascade reads the STRING (so SAP
cross-mapper parity always held), but consumers of the int (e.g.
domain/sap10_ml/transform.py ML aggregates `main_dwelling_roof_
construction`) silently saw None on the Elmhurst path.
New `_elmhurst_roof_construction_int` maps the Elmhurst roof-type code to
the same SAP10 int the API lodges (F→1, PN→3, PA→4, PS→8, S/A→7),
harvested from the committed Summary fixtures. Unlike the wall map it
returns None (not a strict-raise) for unmapped codes: the int is not
cascade-load-bearing, so an unknown roof must not block the cert (vaulted
5 / thatched 6 / NR omitted until a fixture surfaces them).
The 6 hand-built U985 reference fixtures gain the matching
roof_construction int (4/4/3 etc.) so test_from_elmhurst_site_notes_
matches_hand_built_* still asserts structural parity. SAP output is
unchanged (cascade reads the string). §4 suite green (2407 passed); the
two pre-existing stone-§5.6 sap10_ml failures are unrelated/out of scope.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP10 `wall_construction == 6` is canonically WALL_SYSTEM_BUILT — a
WALL TYPE — but the gov-EPC basement heuristic hijacked it: Elmhurst
lodges both "SY System build" and "B Basement wall" as code 6, and the
API lodges basements as code 6 too, so a system-built wall was
mis-flagged `main_wall_is_basement` → wrong RdSAP §5.17 / Table 23
u_basement_wall/u_basement_floor overrides, and downstream the solid-wall
Recommendation Generator couldn't offer EWI/IWI on system-built walls.
System-built stays the wall type on its canonical code 6; the basement
signal moves OFF code 6 to a dedicated `is_basement` (SapAlternativeWall)
/ `wall_is_basement` (SapBuildingPart) Optional[bool] flag:
- Elmhurst: `_elmhurst_wall_is_basement` sets it from the distinct
"SY"/"B" labels (False for SY, True for B, None otherwise).
- gov-EPC API: per-wall code 6 can't be told apart at lodging time, so
`from_api_response` post-processes via `_clear_basement_flag_when_
system_built` — when the cert addendum marks the dwelling system-built,
the code-6 basement heuristic is cleared. A genuine basement (no
addendum signal) keeps the code-6 fallback.
- `main_wall_is_basement` / `is_basement_wall` honour the flag when set,
else fall back to the code-6 heuristic — so untouched API basements and
the cert 000565 "B" cohort are unchanged.
`EpcPropertyData.system_build` is a derived property over the wall type:
the MAIN wall is system-built iff `wall_construction == 6` and it is not
flagged basement. System-built lives on `wall_construction`; the basement
attribute is separate.
Acceptance: a system-built main wall (Elmhurst SY, or API addendum
system_build) → wall_construction == 6, main_wall_is_basement is False,
system_build is True; a genuine basement main wall → main_wall_is_basement
is True, system_build is False. Full §4 suite green (2404 passed).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP10 `wall_construction == 6` is canonically WALL_SYSTEM_BUILT, but
the gov-EPC basement heuristic hijacked it: Elmhurst lodges both "SY
System build" and "B Basement wall" as code 6, so a system-built wall
was mis-flagged `main_wall_is_basement` and routed to the RdSAP §5.17
`u_basement_wall` override instead of the system-built U-value table.
System-built stays on its canonical code 6; the basement signal moves
to an explicit `is_basement` (SapAlternativeWall) / `wall_is_basement`
(SapBuildingPart) Optional[bool] flag, set by the Elmhurst mapper from
the distinct "SY"/"B" codes via `_elmhurst_wall_is_basement` (True for
B, False for SY, None otherwise). The `main_wall_is_basement` /
`is_basement_wall` properties honour the flag when set and fall back to
the gov-EPC API code-6 heuristic when None — so the API path (basement
lodged as integer 6, no flag) and the cert 000565 "B" cohort are
unchanged.
Acceptance (a recommendation-summary generator depends on it): a
system-built MAIN wall reports wall_construction == 6 AND
main_wall_is_basement is False; a genuine basement main wall still
reports main_wall_is_basement is True.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Summary-path mapper raised UnmappedElmhurstLabel for a §15.1
"Cylinder Insulation Type: Jacket" lodging — only "Foam" (→1, factory)
was mapped. SAP10 cylinder_insulation_type uses 2 for loose jacket
(matching the GOV.UK API codes), and SAP 10.2 Table 2 Note 1 gives it a
separate ~2× storage-loss factor that the cascade now handles
(S0380.224). Add "Jacket" → 2 for cross-mapper parity with the API path
and so the loose-jacket storage-loss branch fires on the Summary path.
Surfaced by simulated case 19 (a 210 L jacket cylinder + electric storage
heaters), which previously couldn't extract at all. §4 suite 2397 passed;
mapper.py pyright unchanged at 32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Summary PDFs preprocessed from `pdftotext -layout` wrap the windows-table
header across several lines. The third header line's tail ("U value / g
value / Draught Proofed / Permanent Shutters") tokenises to "value value
Proofed Shutters" and lands directly above the FIRST window's data row.
Because the first window in a building part has `before_start = 0`, its
prefix block reaches back into that header remnant. The remnant is
neither an orientation nor a building-part fragment, so it survived the
pops in `_compose_window_descriptors` and leaked into glazing_type as
"value value Proofed Shutters Double between 2002 and 2021" (windows 2-3,
whose prefix starts after the previous window's manufacturer line, were
clean).
Fix: the glazing-type phrase always starts with a glazing-start word
(Single/Double/Triple/Secondary), so trim any prefix fragments preceding
that word before joining the glazing type. Orientation/bp pops still run
on the full prefix, so they are unaffected.
Reproduced from `sap worksheets/Recommendations Elmhurst Files/
cavity_wall_insulation - main wall/before/Summary_001431.pdf`. Added a
regression test driving the real `_extract_windows_from_layout` path with
the verbatim tokenised header+rows. 2306 passed (+4), pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated 001431 case (the cert that drove S0380.189/.190)
as an Elmhurst-only e2e fixture: Summary PDF → extractor → mapper →
calculator, every Block-1 SapResult field pinned against the
P960-0001-001431 worksheet at abs=1e-4. All 11 pins pass with zero
residual — the case is clean, confirming the S0380.190 gas-combi fuel
derivation closes the Summary path natively.
Verified the handover's flagged "+0.0007 SAP" was a target artifact, not
a cascade gap: the worksheet displays ECF (257) rounded to 1.6047 and
integer SAP (258)=78; the cascade's continuous SAP is computed from the
UNROUNDED ECF = (255)*(256)/((4)+45) = 660.9750*0.4200/173.0, giving
77.6147 — which matches the worksheet's own unrounded value. Pinning the
continuous SAP from the display-rounded ECF (→ 77.6144) was the wrong
target. Block-1 line refs all match exactly: (211) 10699.7225, (219)
3327.1592, (231) 86.0, (232) 283.2229, (255) 660.9750, (272) 3000.1664,
Σ(98) 8987.7669.
Summary mirrored into the tracked fixtures dir as
Summary_001431_gas_combi.pdf (distinct name — the corpus reuses cert
001431 across every heating variant); source Summary + worksheet tracked
under sap worksheets/golden fixture debugging/ as the pin ground truth.
2302 passed (+11), 0 failed; pyright net-zero on new/changed files.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
CH6's P960 worksheet input lodges Distribution Loss = "Two adjoining
dwellings sharing a single heating system" → (306) DLF = 1.0000, vs CH4's
"Calculated" → 1.5 → (306) = 1.4500. That DLF choice swings SAP/cost/CO2/PE
materially, but it is NOT present in the Summary PDF that the corpus pipeline
consumes (Summary → ElmhurstSiteNotesExtractor → mapper → calculator).
Proven empirically with a user-supplied controlled pair (CH adjoined
dwellings/Summary_001431 (1) vs (2)): the two Summaries are byte-identical
across every RdSAP INPUT field, differing only in the derived header
(SAP 80 vs 75, bill £954 vs £1237, emissions 5.407 vs 7.394 t). A
case-insensitive scan of the CH6 Summary for "distribution"/"adjoin" returns
0 hits. Since CH4/CH6 Summaries are themselves identical bar fuel type, no
Summary-derivable rule can yield CH4=1.45 AND CH6=1.0.
Doc-only change (comment in _EXPECTATIONS); 20/20 community-heating corpus
tests pass. Closes the CH6 re-litigation: pin held.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 worksheet block 12b/13b (367)/(467) for a community heating
electric heat pump (Table 4a code 304 → Table 12 fuel 41 "heat from
electric heat pump"). The HP meters grid electricity, so per Table 12
note (s)/(t) + block 12b/13b footnote (a) its emission/PE factor is the
MONTHLY Table 12d/12e cascade (fuel 41 = standard-electricity profile),
weighted by the network heat profile, then × 1/heat-source-eff (1/COP):
(367)/(467) = [(307)+(310)] / COP × Σ((307+310)_m × factor_m)/Σ(...)
Per-line walk of CH3 (the displayed (367) 0.1535 / (467) 1.5717 are PDF
artifacts; the (373)/(473) totals reconcile only with):
CO2 factor = 0.15040 (monthly Table 12d wtd) vs cascade annual 0.136
PE factor = 1.55692 (monthly Table 12e wtd) vs cascade annual 1.501
Pre-slice the cascade routed code 304 through the non-electric branch
(`_co2_factor_kg_per_kwh(main) × 1/COP` = annual × scaling). New
`_is_heat_network_electric_main` (heat-network main whose fuel has a
Table 12d monthly set — i.e. fuel 41) routes all four factor helpers
(main + HW, CO2 + PE) through the monthly cascade × 1/COP. Non-electric
heat networks (gas 51 / oil 53 / coal 54) have no monthly set → annual
path unchanged (CH1, CH6 untouched).
Closure (CH3 was already SAP+cost EXACT):
CH3 (HP/Elec) CO2 −75.32→+0.0000 (= [(307+310)/3]×(0.1504−0.136)),
PE −249.32→−0.0000 (× (1.5569−1.501)) — FULLY EXACT
Corpus now 40/41 EXACT on all four metrics. Only CH6 remains: its
worksheet lodges a manual DLF=1.0 ("two adjoining dwellings") absent
from the Summary PDF (byte-identical to CH4 bar fuel type) — an
architectural limit, not a cascade gap. 2226 pass + 1 skip + 0 fail
(tolerances 1e-4 all metrics); pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 §10b: hot water for a community-heating dwelling bills at the
heat-network rate, not the cert-lodged fuel. Elmhurst §15.0 lodges
`water_heating_fuel_type = "Mains gas"` (3.48 p/kWh) as a placeholder on
community certs; the worksheet (342) Water-heating cost = (310) × the
S0380.171 CHP heat-fraction blend — the SAME rate as space heating (340).
Per-line walk of the CH2 block 10b:
(340) space = 11837.83 × 0.037955 = 449.3047 (cascade EXACT)
(342) water = 3854.12 × 0.037955 = 146.2830 (cascade billed
3854.12 × 0.0348 = 134.12 → −£12.16, the whole residual)
(350) lighting + (351) standing → (355) 754.1502.
`_hot_water_fuel_cost_gbp_per_kwh`'s `inherit_main_for_community_heating`
path already routes HW cost through `_fuel_cost_gbp_per_kwh(main)` (the
CHP blend), but its gate `_is_community_heating_hw_from_main` excluded
code 302. S0380.182 wired the 302 CO2/PE credit via
`_heat_network_code_302_effective_factor`, which intercepts the HW
CO2/PE helpers ABOVE this predicate's branch — so extending the
predicate to include 302 now affects ONLY the cost path.
Closures:
CH2 (CHP/Gas) SAP +0.5277→−0.0000, cost −£12.16→−£0.00 — FULLY EXACT
CH4 (CHP/Oil) SAP +0.5277→−0.0000, cost −£12.16→−£0.00 — FULLY EXACT
CH6 (CHP/Coal) SAP −7.49→−8.02, cost +£172.68→+£184.84 — its HW now
also bills the blend, compounding the DLF=1.0 quirk
(cascade DLF=1.45); same separate CH6 DLF front.
Corpus now 39 variants EXACT on all four metrics (CH2/CH4 join). Open:
CH3 CO2/PE (code-304 community-HP COP), CH6 all-metric (DLF=1.0 manual
override the Summary doesn't carry). 2225 pass + 1 skip + 0 fail
(tolerances 1e-4 all metrics); pyright net-zero 32→32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 worksheet block 12b (CO2) / 13b (PE) for community heating
"CHP and boilers" (SAP code 302). Per unit of network heat fuel
H = (307)+(310) the effective generation factor is:
chp×100/(362)×f_fuel − chp×(361)/(362)×f_disp + (1−chp)×100/(367)×f_fuel
(363)/(463) CHP fuel = chp_frac × 100/heat_eff × f_fuel
(364)/(464) less credit = −chp_frac × elec_eff/heat_eff × f_disp
(368)/(468) boiler fuel = (1−chp_frac) × 100/boiler_eff × f_fuel
f_fuel = Table 12 heat-network fuel factor (the CHP unit and the back-up
boilers burn the same community fuel — verified vs CH2 gas / CH4 oil /
CH6 coal worksheets (363)/(368)); f_disp = Table 12f (PDF p.196) credit
for the CHP-generated electricity. RdSAP 10 §C (p.58) defaults: heat eff
50% (362), electrical eff 25% (361), boiler eff 80% (367); CHP heat frac
0.35 per-cert via community_heating_chp_fraction.
New `_heat_network_code_302_effective_factor` + Table 12f flexible
constants (0.420 CO2 / 2.369 PE) + RdSAP §C efficiency constants, wired
into all four factor helpers (main + HW, CO2 + PE) ahead of the existing
single-fuel / 1-over-heat-source-eff path. The worksheet (368)/(468)
boiler emissions DISPLAY rounded/mis-aligned in the PDF, but the
(373)/(473)/(386)/(486) totals reconcile only with the boiler at the
full Table 12 factor — verified EXACT.
Two spec citations applied:
- Table 12f flexible-operation default for RdSAP community CHP is an
Elmhurst engine choice (Table 12f notes make "standard" the default);
mirrored per [[feedback-software-no-special-handling]] and documented
in SAP_CALCULATOR.md §8.3.
- Table 12 heat-network oil/biodiesel CO2 (codes 53/56) corrected
0.298 → 0.335 per Table 12 (p.189) "assumes 'gas oil'"; the code-302
oil cascade (CH4) was the first to exercise it. PE 1.180 was already
correct. No other variant uses these codes (no regression).
Closures (CO2 + PE only — the CHP credit does not touch cost/SAP):
CH2 (CHP/Gas) CO2 −1411.49→+0.0000, PE +1331.23→+0.0000 EXACT
CH4 (CHP/Oil) CO2 −4378.24→−0.0000, PE +319.81→−0.0000 EXACT
CH6 (CHP/Coal) CO2/PE re-pinned (+2411.54 / +5023.48) — its worksheet
lodges a manual DLF=1.0 the Summary doesn't carry, so
cascade DLF=1.45 over-scales H; same root as the CH6
SAP −7.49 / cost +£172 (separate DLF front).
CH2/CH4 are now CO2+PE-exact but still carry the heat-network cost/SAP
residual (+0.5277 SAP / −£12.16 cost, exposed by S0380.175 — cost-side,
untouched here). CH3 unchanged (code 304 community-HP COP front).
Corpus state: 37 variants EXACT on all four metrics (incl. CH1);
remaining residuals are CH2/CH4 cost+SAP, CH3 CO2+PE (HP COP), CH6
all-metric (DLF quirk). 2223 pass + 1 skip + 0 fail (tolerances 1e-4 all
metrics per S0380.181); pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The corpus residual-pin tolerances had drifted looser than the comment
above them claimed ("pin at 1e-4 relative to lodged precision"): SAP was
1e-3, cost ±£0.01, CO2 ±0.1 kg, PE ±0.1 kWh. A ±0.1 kg CO2 band could
silently mask a ~0.09 kg drift on a variant we report as EXACT.
The worksheet pins are extracted from the P960 PDF text, which prints
4 d.p., so the hard residual floor is ~5e-5 (half a unit in the last
printed digit) regardless of cascade precision. 1e-4 sits just above
that floor. All 41 variants hold at uniform 1e-4 on continuous SAP,
cost, CO2 AND PE — confirming the 37 EXACT variants are genuinely exact
to PDF print-rounding and the looser bands were masking nothing.
Aligns the guard with [[feedback-zero-error-strict]] /
[[feedback-continuous-sap-tolerance]] (basically zero error across all
four metrics). Test-only change; no cascade behaviour touched.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix C §C3.2 (PDF p.51), verbatim: "CO2 emissions and
Primary Energy associated with the electricity used for pumping water
through the distribution system are allowed for by adding electrical
energy equal to 1% of the energy required for space and water heating."
Worksheet line (313) = 0.01 × [(307)+(310)]; its CO2 (372) and PE (472)
bill on the Table 12d/12e monthly factors for fuel code 50 ("electricity
for pumping in distribution network"), weighted by the monthly heat
profile per worksheet footnote (a). (307)m/(310)m = (space_demand +
hw_output) / efficiency (the cascade models a heat network's generator
efficiency as 1/DLF).
This un-defers the (372)/(472) front the post-S0380.179 handover flagged
"don't guess until the factor source is identified": the source is
§C3.2 + Table 12d/12e code 50, NOT an empirical constant. The apparent
0.1994/0.2114 "factor" is an Elmhurst DISPLAY artifact — the worksheet
shows the (372) energy column as 0.01×(307) (space only) while computing
emissions on 0.01×(307+310) per the §C3.2 text. Verified EXACT line-by-
line against the CH2 corpus worksheet: (372)=23.6007 CO2 (rating),
(472)=208.2267 PE (demand).
New `_heat_network_distribution_electricity` helper (gated on
`_is_heat_network_main`) precomputes the energy + effective CO2/PE
factors; three new CalculatorInputs fields + calculator.py CO2/PE
summation terms (0.0/None → no-op for individually-heated certs).
Closures:
CH1 (Boilers/Gas) CO2 −23.60→−0.00, PE −208.23→+0.00 — FULLY EXACT
CH3 (HP/Elec) CO2 −98.92→−75.32, PE −457.54→−249.32 (distribution
component closed; code-304 community-HP COP remains)
CH2/CH4/CH6 gain their (372)/(472) component (CO2 +23.6, PE
+208.2); dominant CHP displaced-electricity credit
residual (Table 12f + block 12b/13b) is next slice.
No regression on the other 36 corpus variants (helper returns None off
heat-network mains) + golden + U985 fixtures. 2223 pass + 1 skip + 0
fail; pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The calculator tests lived under domain/sap10_calculator/{tests,worksheet/
tests,rdsap/tests,climate/tests,validation/tests}, none of which are in
pytest.ini testpaths — so CI (which collects tests/) never ran them. Relocate
all five dirs to tests/domain/sap10_calculator/{,worksheet,rdsap,climate,
validation}, mirroring the tests/domain/property_baseline/ convention, so the
cascade-pin / golden / e2e conformance suites run in CI.
Mechanics:
- git mv preserves history (110 files).
- Flattening the trailing /tests keeps each file's depth-to-repo-root
identical, so all 16 repo-root parents[4] fixture refs stay valid. Only
test_pcdb_etl.py's parents[1] (→ pcdb data) and one hardcoded absolute
golden-fixture path in test_cert_to_inputs.py needed rebasing.
- Cross-imports rewritten domain.sap10_calculator.worksheet.tests →
tests.domain.sap10_calculator.worksheet (21 files incl. the external
importer backend/documents_parser/tests/test_summary_pdf_mapper_chain.py).
- Golden-fixture path strings in test_summary_pdf_mapper_chain.py +
scripts/fetch_cohort2_api_jsons.py updated to the new location (the JSONs
moved with the rdsap tests).
load_cells / gitignored worksheet xlsx: the xlsx-pinned tests (test_dimensions
/ ventilation / water_heating) read 2026-05-19-17-18 RdSap10Worksheet.xlsx,
which is gitignored (.gitignore `*.xlsx`) and so absent in CI. _xlsx_loader.
load_cells now pytest.skip()s when the file is absent, so those tests run
locally and skip cleanly in CI instead of erroring — no new CI failures from
the move, and the gitignore policy is respected.
Verified: tests/domain/sap10_calculator + backend/documents_parser +
tests/domain/property_baseline = 2248 pass, 1 skipped; pyright resolves the
new import paths with zero import-resolution errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Closes the "no system" corpus variant fully (ΔSAP +1.18 → <1e-4 on all
four metrics).
The cert lodges §15.0 "Water Heating Code: NON / SapCode 999" and §15.1
"Hot Water Cylinder Present: No". Per RdSAP 10 §10.7 (PDF p.55) "No
water heating system" verbatim: "the calculation is done for an
electric immersion heater. If the electric meter is dual the immersion
heater is also dual, but is a single immersion otherwise... for a
cylinder defined by the first row of Table 28 (110 litres) and the
first row of Table 29." Table 29 row 1 gives age-band cylinder
insulation (age G -> 25 mm foam) and assumes a cylinder thermostat
present for immersion-heated DHW.
The BRE-approved Elmhurst engine confirms the substitution: the P960
worksheet header lodges "WHS: 903 Electric immersion, Single", a 110 L
cylinder, and storage loss (56) = 594.32 kWh/yr, so HW (64) = (45)
1935.37 + 594.32 = 2529.6927.
Pre-slice the cascade trusted the lodged "no cylinder" -> added no
storage loss and a spurious Table 3a keep-hot combi loss; the wrong HW
heat-gains also propagated through §5/§7, over-stating the base MIT by
+0.25 K and space fuel by +228 kWh. New
`_apply_rdsap_no_water_heating_system_default(epc)` rebinds the epc at
the top of cert_to_inputs (the demand cascade delegates here too) when
water_heating_code == 999, injecting WHC 903 + electricity fuel +
110 L cylinder + Table 29 insulation + assumed cylinder thermostat.
This closes HW fuel AND the downstream space residual in one move.
Age bands A-F (12 mm loose jacket) raise UnmappedSapCode — no corpus
member exercises that and the Table 2 loss-factor dispatch only has the
factory-foam path plumbed. Gate is keyed on code 999, unique to "no
system" in the corpus; 40 other variants + 858 section pins + 6 U985
fixtures unchanged. 936 pass; pyright net-zero 32 -> 32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Closes the residual S0380.177 exposed on oil 6. The cascade's central
heating pump used the bare Table 4f age default (41 kWh for "2013 or
later") but the worksheet (230c) = 53.3 kWh.
SAP 10.2 Table 4f (PDF p.175) footnote a) on the "Circulation pump"
rows reads verbatim: "Multiply by a factor of 1.3 if room thermostat
is absent." oil 6 lodges control code 2101 ("No time or thermostatic
control of room temperature") = no room thermostat, so 41 x 1.3 = 53.3
= ws (230c) EXACTLY; pumps/fans (231) = 53.3 + 100 (liquid-fuel boiler
flue fan/pump) = 153.3 EXACT. Same root cause (absent room thermostat)
as the S0380.177 Table 4c(2) interlock fix — both keyed on the new
`_BOILER_NO_ROOM_THERMOSTAT_CONTROL_CODES = {2101, 2102}`.
`_table_4f_circulation_pump_kwh` now multiplies the resolved pump kWh
by `_TABLE_4F_NO_ROOM_THERMOSTAT_PUMP_MULTIPLIER = 1.3` when the main's
control code is in that set.
oil 6 now FULLY EXACT on all four metrics (ΔSAP/cost/CO2/PE < 1e-4).
The sibling oil 5 (same "2013 or later" pump age but control 2106 WITH
a room thermostat) keeps the bare 41 kWh and is unaffected — as do the
other 39 corpus variants (2101/2102 appear only on oil 6). 935 pass;
pyright net-zero 32 -> 32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
oil 6 (B30K standard liquid-fuel boiler, Table 4b code 126 winter 80 /
summer 68) lodges Main Heating Controls Sap code 2101 ("No time or
thermostatic control of room temperature") WITH a cylinder thermostat.
The cascade's `no_interlock` gate only checked the cylinder thermostat,
so oil 6 kept raw efficiency despite the P960 worksheet header lodging
"Boiler Interlock: No".
Per RdSAP 10 §3 (PDF p.57): boiler interlock is "assumed present if
there is a room thermostat and (for stored hot water systems heated by
the boiler) a cylinder thermostat. Otherwise not interlocked." Control
code 2101 (and 2102 "Programmer, no room thermostat") provides no room
thermostat — the two Table 4e Group 1 rows carrying the "+0.6 °C /
Table 4c(2)" annotation — so the boiler is NOT interlocked regardless
of the cylinderstat. SAP 10.2 Table 4c(2) (PDF p.169) "No thermostatic
control of room temperature – regular boiler" then deducts 5pp from
BOTH the Space and DHW seasonal efficiency.
Three changes in cert_to_inputs.py:
- new `_BOILER_NO_ROOM_THERMOSTAT_CONTROL_CODES = {2101, 2102}`;
- `no_interlock` now ORs room-thermostat absence with the existing
stored-HW cylinderstat-absence test (the RdSAP §3 conjunction);
- the Space -5pp leg fires for Table 4b non-PCDB boilers (code
101-141), not only PCDB-record boilers; the DHW leg is gated on a
cylinder being present (Table 4c(2) combi DHW = 0).
Result for oil 6: space fuel (211) = 13446.3457 EXACT, HW fuel (219) =
4099.5872 EXACT. ΔSAP +3.0518 → +0.0782, Δcost -£69.79 → -£1.68,
ΔCO2 -240.66 → -1.71, ΔPE -1112.66 → -18.61.
The spec-correct fix exposes a single residual cause (per
[[feedback-software-no-special-handling]]): the central heating pump
(230c) — cascade reads pump_age=2 → Table 4f 41 kWh but ws (230c) =
53.3 kWh. The 12.3 kWh gap fully accounts for the residual across all
three metrics; pinned as the S0380.178 forcing function.
All other 40 corpus variants + 858 section pins + 6 U985 fixtures
unchanged (2101/2102 boiler codes appear only on oil 6). Pyright
net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 §4 line 7702 (PDF p.137) defines (61)m as "Combi loss for
each month from Table 3a, 3b or 3c (enter '0' if not a combi
boiler)". Table 4b sub-rows 128 / 129 / 130 are explicit combi sub-
rows per the spec row names:
128: Combi oil boiler, pre-1998
129: Combi oil boiler, 1998 or later
130: Condensing combi oil boiler
Pre-slice `_table_3a_combi_loss_default_applies` gated only on
`main_heating_category ∈ {1, 2, 3, 6}`. The Elmhurst mapper leaves
`main_heating_category=None` on Table 4b liquid-fuel boilers (FAME,
HVO, B30K) — the cascade fell through to (61)m=0 despite the lodged
SAP code being a combi sub-row, under-counting (62)m by 600 kWh/yr
for FAME combi certs.
Extended the helper with a `_TABLE_4B_COMBI_OR_CPSU_CODES` fall-
through (set already exists for the symmetric `_primary_loss_
applies` Table 4b non-combi branch — see S0380.146). The set carries
the canonical combi + CPSU sub-row codes (103/104/107/108/112/113/
118/120-123/128-130). For cylinder-lodged certs the existing
`if epc.has_hot_water_cylinder: combi_loss_override = zero_monthly`
guard in `_water_heating_worksheet_and_gains` still pre-empts the
combi-loss fall-through correctly — non-combi codes with cylinders
remain (61)m=0.
Closures (heating-systems corpus 001431):
oil 3 (code 128, FAME, no cylinder) ALL EXACT (±0.0000):
ΔSAP_c +2.5863 → -0.0000
Δcost -£61.89 → -£0.00
ΔCO2 -14.58 → +0.00
ΔPE -967.10 → +0.00
oil 4 (code 129, FAME, no cylinder) ALL EXACT (±0.0000):
ΔSAP_c +2.5603 → +0.0000
Δcost -£56.66 → +£0.00
ΔCO2 -13.35 → +0.00
ΔPE -884.90 → +0.00
Oil 6 (code 126, NOT a combi, with cylinder) unchanged — the fix
is gated on the combi sub-row set. Cohort moves from 9 pinned
residuals to 7.
933 pass + 0 fail (+1 new mapper test). Pyright net-zero on cert_
to_inputs.py + tests.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
SAP 10.2 Table 4e Group 3 (PDF p.173) — heat-network control codes
2301-2314 dispatch to control_type 1, 2, or 3. Code 2306 = "Charging
system linked to use of heating, programmer and TRVs" →
control_type=3, temperature_adjustment=0. Per Table 9 the elsewhere-
zone off-hours depend on control_type: type 1/2 → (7, 8); type 3 →
(9, 8). The two extra off-hours change the §7 (90) T_rest mean by
~0.6 K → (92) MIT by ~0.4 K → (98) SH demand by ~390 kWh/yr.
Pre-slice diagnosis: cascade defaulted `main_heating_control=2`
(modal RdSAP) when the §14.0 "Main Heating Controls Sap" field was
empty. The 5 community heating corpus variants ALL lodge the SAP
code in §14.1 Community Heating "Heating Controls SAP" instead
(format: bare 4-digit integer, e.g. "2306"). The extractor was
storing this in `CommunityHeating.heating_controls_sap` but the
mapper only read `mh.heating_controls_sap` (§14.0).
Two changes:
1. `_elmhurst_sap_control_code` extended to accept bare 4-digit form
("2306") in addition to the §14.0 narrative form ("SAP code 2106,
Programmer, room thermostat and TRVs"). Empty-string returns None
instead of swallowing through the original `re.match` regex.
2. `_map_elmhurst_sap_heating` falls through to
`mh.community_heating.heating_controls_sap` when the §14.0 main
block leaves `heating_controls_sap` empty.
Closures (heating-systems corpus 001431):
CH1 ΔSAP_c -1.0572 → +0.0000 EXACT
Δcost +£24.36 → -£0.00 EXACT
CH3 ΔSAP_c -1.0572 → +0.0000 EXACT
Δcost +£24.36 → -£0.00 EXACT
CH2/CH4 SAP-side flip ±0.42 → ±0.53 (CHP-split blend reacts to
the now-lower SH demand × CHP rate)
CH6 ΔSAP_c -8.4406 → -7.4942 (DLF=1.0 P960 quirk untouched)
Remaining CH1/CH3 ΔCO2 -23.60 / ΔPE -208.23 is the §13a (372)
"Electrical energy for heat distribution" line (118.38 kWh × electric
factors 0.1993 CO2 / 1.760 PE). Cascade doesn't currently meter this
electricity overhead separately from heat-network heat — next slice.
932 pass + 0 fail (+5 new mapper tests). No regressions on the other
36 corpus variants — the mapper change is gated on `mh.community_
heating is not None` and only fires when §14.0 leaves the control
field empty. Pyright net-zero on mapper.py + corpus test.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
SAP 10.2 §4 "Heat networks" (PDF p.17 line 1482):
"Primary circuit loss for insulated pipework and cylinderstat
should be included (see Table 3)."
SAP 10.2 Table 2b note b (PDF p.159) verbatim:
"Multiply Temperature Factor by 0.9 if there is separate time
control of domestic hot water (boiler systems, warm air systems
and heat pump systems)."
The Table 2b note b ×0.9 multiplier is restricted to "boiler / warm
air / heat pump systems" — community heating is omitted from that
verbatim list. Pre-slice the cascade applied the ×0.9 reduction
unconditionally when DHW was separately timed, AND omitted the Table
3 primary-loss path for heat-network mains entirely. Combined the
two gaps under-counted (62)m HW total demand by ~320 kWh/yr for
heating-systems corpus 001431 community heating 1 (8164 + 0 vs
448.74 + 273.90 spec losses).
Three changes:
1. New `_HEAT_NETWORK_PIPEWORK_INSULATION_FRACTION = 1.0` constant.
`_primary_loss_override` selects this for heat-network mains
instead of the RdSAP §3 age-band default, per the spec's literal
"insulated pipework" + back-solve from worksheet (59) Jan = 23.26
= 31 × 14 × (0.0091×3 + 0.0263).
2. Extended `_primary_loss_applies` with a new branch: heat-network
main + WHC ∈ {901, 902, 914} + cylinder present → primary loss
applies.
3. New `_table_2b_note_b_multiplier_applies(epc, main)` predicate
that gates the ×0.9 storage-loss reduction on the spec's verbatim
system-type list, returning False for heat-network mains. The
primary-loss `_separately_timed_dhw` continues to return True for
community heating (Table 3's "separately timed" row is system-
type-agnostic and gives h=3 all year).
Closures (heating-systems corpus 001431):
CH1 HW kWh 3391.90 → 3854.12 (= ws 3854.1175, abs Δ < 1e-3)
CH1 HW cost £143.82 → £163.41 (= ws £163.41, EXACT)
CH1 (65)m heat gains 793.51 → 1221.62 (= ws 1221.62, EXACT)
CH2/CH3/CH4/CH6 same shape — HW path closes against ws (310).
§4 fix is spec-correct on all 5 CH variants. The closure surfaces a
separate §7 MIT (92)m over-count of +0.46 K (cascade Jan = 17.22 vs
ws 16.76) that the pre-slice (65)m gain under-count was masking. Per
[[feedback-software-no-special-handling]] apply the spec-correct
fix uniformly; new pinned residuals reflect the exposed MIT gap.
New residuals (vs pre-slice):
CH1 ΔSAP -0.5273 → -1.0572 ΔPE -9.15 → +408.67
CH2 ΔSAP -0.0076 → -0.4187 ΔPE +1506 → +1779
CH3 ΔSAP -0.5273 → -1.0572 ΔPE -387.03 → -239.03
CH4 ΔSAP -0.0076 → -0.4187 ΔPE +494.61 → +767.13
CH6 ΔSAP -8.0295 → -8.4406 ΔPE +7864.60 → +8137.11
927 pass + 0 fail (+1 new test). No regressions on the other 36
corpus variants — the gate is narrow on `_is_heat_network_main`.
Pyright net-zero (43 → 43) on cert_to_inputs.py + tests.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>