Support for the per-cert Elmhurst worksheet loop:
- goto()/save_close(): fall back networkidle -> domcontentloaded on
timeout so an incomplete-validation state (half-set RR, 0-area window)
no longer hangs navigation.
- add_combined_window(): select glazing first (AutoPostBack), then JS
input+change+blur the width/height with settle waits so the Area cell
computes before Add (a plain .fill() raced the postback -> 0.00 row).
- set_single_window(): leave the grid holding exactly one row, deleting
rows carried over from a prior build of the SHARED assessment (the
window grid is the only accumulating page).
- reset_transient_state(): return the shared assessment to neutral after
a run (clear RR age band, secondary = No, meter = Single).
KNOWN RESIDUAL: the window grid still intermittently persists a 0.00 area
through Save & Close (Elmhurst's "each Add wipes the previous row" +
last-row-undeletable behaviour), and the secondary-heating dialog's modal
background can intercept the cascade click. Reliable autonomous grinding of
per-cert builds needs these two hardened further; the loop currently
completes clean single-main gas certs (see the 47084930 flat-roof slice)
but stalls on secondary-heating + stale-window combinations. build_
100021924710.py is the WIP template for that harder shape.
No engine change.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
A FLAT roof lodges its insulation thickness in the DEDICATED gov-EPC API
`flat_roof_insulation_thickness` field (e.g. "75mm"), leaving
`roof_insulation_thickness` None (that field is for pitched-loft joists).
`heat_transmission_from_cert` read only the latter, so a measured
flat-roof thickness was ignored and the roof billed at the uninsulated
age-band flat default (age E = 1.5) instead of its Table-16 insulated U.
Fixed by preferring `flat_roof_insulation_thickness` when the part is a
flat roof — the exact mirror of the existing rafter-thickness branch.
An "AB"/"NI" (as-built/unknown) value parses to None and keeps the
age-band default, unchanged; only measured thicknesses move.
PER-CERT ELMHURST VALIDATION (cert 47084930, top-floor flat, flat roof
75 mm): built on the lodged inputs in accredited Elmhurst RdSAP10-Online
(evidence saved: elmhurst_summary.pdf / elmhurst_worksheet.pdf). The
worksheet bills "insulated flat roof" at U 0.5 (floor 0.70 + wall 0.25
also matching the engine). The fix takes the engine roof 96.4 -> 32.1 W/K
(= 64.26 x 0.5, Elmhurst-exact), PE +47 -> +0.2, SAP 69.51 -> 74.34 =
lodged 74.
Gauge: within 77.3% -> 77.7%, SAP MAE 0.648 -> 0.641, CO2 0.074 -> 0.072,
PE 3.1 -> 2.97. Unit-pinned in test_heat_transmission
(flat_roof_insulation_thickness -> U 0.5); RealCertExpectation 47084930
= 74 (Elmhurst-validated). Also adds the build script build_47084930.py.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Built the cert in accredited Elmhurst RdSAP10-Online on the lodged register
inputs; downloaded Input Summary + SAP Worksheets (committed alongside).
Confirmed:
- Slice 5 DIRECTION validated: the externally-insulated solid-brick wall is
billed insulated by both tools (Elmhurst U 0.48, engine U 0.29), far below
the uninsulated 1.40 the pre-fix §5.8 gate produced.
- ROOF matches EXACTLY (U 0.30, 9.35 W/K).
- Engine 71.74 = lodged 71; Elmhurst current SAP 66 (its "unknown external
insulation" default is more conservative + this build used a generic combi
and no keyed wall thickness, so 66 is not a clean engine-comparison).
Follow-up lead (documented in ELMHURST_FINDINGS.md): the engine feeds the
UNMEASURED lodged wall_thickness (360 mm, measured=N) into the §5.6 formula,
whereas RdSAP §5.3 uses measured thickness / Table-3 default otherwise. The
party-wall "difference" is NOT a bug (engine 0.25 is spec-correct, Table 15
row 4). Also adds the build script scripts/hyde/build_200004296092.py.
No engine change in this commit.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Captures the calc-facing ventilation-type gap (older RdSAP mappers drop
mechanical_ventilation_kind), the FE-side Main Fuel display, the sweep survivor
clusters, and the predicted-property display path — all separate from ADR-0037.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
In-container Playwright runs were flaky: the chromium renderer crashed
mid-build ("Target crashed") on the 64M /dev/shm, and login intermittently
hung. Added `--disable-dev-shm-usage` + `--no-sandbox` launch args, a
4-attempt login retry loop (domcontentloaded + explicit selector wait),
and an `ELM_GUID` env override so a per-UPRN assessment can be targeted
without editing the module. Tooling only — no calculator impact.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Corpus validation of the modelling_e2e photovoltaic_supply-as-list fix. Cert
6102-6227-8000-0083-2292 (RdSAP-20.0.0 semi, gas combi + 2× 1.14 kW PV arrays)
crashed from_rdsap_schema_20_0_0 on the measured-array list; the fix routes it
through the dict-tolerant _map_schema_21_pv. PV correctly credited: engine 61
(no PV) → 66 (+5). Built in Elmhurst (evidence: epc.json + summary + worksheet,
fabric+heating; the PV "New Technologies" Panel-details grid deferred): worksheet
55 = engine-on-Elmhurst-inputs 55 exactly → calculator faithful. The +6 engine-vs-
Elmhurst base-dwelling residual is the documented RdSAP-default gap (band-C cavity-
uninsulated suspended-floor semi). Pinned engine 66.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Corpus validation of the modelling_e2e built_form fix. Cert 8742-6624-9300-2780-4926
(SAP-Schema-16.0, ground-floor electric-storage-heater flat) omits built_form; the
mapper now derives it from dwelling_type. built_form is ML-only so the fix is
SAP-neutral: engine 66 = lodged 66 exactly. Built in Elmhurst (evidence: epc.json +
summary + worksheet): worksheet 54, engine-on-Elmhurst-inputs 53 ≈ 54 → calculator
faithful. The +12 engine-vs-Elmhurst is a build/input gap (cert size-1 small cylinder
unrepresentable in Elmhurst's Normal/110L-minimum entry → higher HW + reduced-field
16.0 defaults). Pinned engine 66.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Two-pass org_ref-matched builder for property_overrides (classify via ChatGPT
into the landlord ledger, validate+apply user edits, write idempotently);
ephemeral-Postgres smoke proves the one-property chain without creds.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Every worklist UPRN now carries schema · engine SAP / lodged · flag. Tally:
64 healthy, 19 MVHR-not-credited (🚩 flag B), 6 heat-pump fuel-39 (🚩 flag A),
4 sparse/NOT MAPPABLE (⛔), 3 Elmhurst-pinned. MVHR is the largest accuracy gap.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Autonomous-run triage of the moderate eng-vs-lodged gaps resolves them into two
patterns, both flagged for owner review (not auto-fixable):
- Heat-pump fuel code 39 mis-priced as gas (over-rates; both gap directions).
- MVHR heat recovery modelled as plain extract loss → systematic UNDER-rating
(~8-12 SAP) on every full-SAP cert carrying a mechanical_vent_system_index_number.
New memory mvhr-heat-recovery-not-modelled; needs the Appendix Q / PCDB MVHR
efficiency model.
findings doc updated with the classification.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Some SAP-Schema-17.x/18.0.0 certs lodge sap_openings width/height in MILLIMETRES
mixed with metre rows in the same array (e.g. a 2025x2100 mm window beside a
3.06x1 m one). The 17.1 mapper read them all as metres → a 4.25M m2 window →
HTC in the millions → SAP clamped to 1.
Fix (TDD, datatypes/epc/domain/mapper.py): _sanitise_opening_dimension_m treats
any dimension > 50 m as mm and divides by 1000; _sap_opening_area_m2 applies it
to areas. Wired into the window, roof-window, and door-area-weighting paths.
The 3 broken certs (uprn_10093117227 / 10090317693 / 10091636031) now score
90 / 81 / 79 instead of 1.
3 RED->GREEN slices + refactor; new test class
TestFromSapSchema17_1OpeningUnitSanitisation + sap_17_1_mm_openings.json fixture;
0 new pyright errors; no regressions.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Schema coverage (datatypes/epc/domain/mapper.py):
- SAP-Schema-18.0.0: full-SAP shape ≡ 17.1 → from_sap_schema_17_1, no normalisation.
- SAP-Schema-16.0: same reduced-field 16.x path; default the omitted `tenure`
field in _normalize_sap_schema_16_x (metadata; SAP cascade never reads it).
Genuinely sparse 16.x certs (missing core fabric fields) still fail loud.
- Regression tests + sap_18_0_0.json / sap_16_0.json fixtures; 0 new pyright errors.
Autonomous triage of the worklist (scripts/hyde/autonomous_run_findings.md):
- Found + diagnosed 2 bugs (flagged, NOT fixed): (1) MAPPER — full-SAP openings
lodged in mm read as m → multi-million-m2 windows → SAP clamps to 1 (uprn_
10093117227 / 10090317693 / 10091636031); (2) CALCULATOR — database heat-pump
fuel code 39 mis-priced as gas, over-rates ~14 (uprn_10093114053).
- Most certs map within +/-4 of lodged.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>