Review feedback (#1481): the address batcher and the Modelling Run batcher
implemented the same greedy packing; the core moves to
utilities/grouped_batching.py and both become thin wrappers.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
roof_construction codes group by FORM (empirical: 1=Flat 98%, 4/5/8=
Pitched 88-99%, 3=dwelling-above 100% over 7,974 certs; 7/9=premises-
above per #1452), so the filter matches families — an exact-code filter
would wrongly drop pitched neighbours lodged as 5/8. Historic prefixes
map to the same families; roof rooms and thatch stay unconditioned.
Harness ladder replay and telemetry mirror the new filter.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Evidence (439-pair harness, PR #1466): historic-vs-new age band agrees
52% exactly but 90% within one band (assessors re-band, skewing newer);
TFA agrees 45% within ±5% but 82% within ±20%. Equality/±5% steered the
cohort toward stale values where they engaged and relaxed everywhere
else. Band definitions are public so the harness's ladder replay shares
one source of truth.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Strip the pre-RdSAP-17 deprecation rider and alias the SAP-prefixed
forms before the code-table lookup. Raises the historic fuel resolution
rate from ~22% of pairs to ~92% of dump rows.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Ingestion's lookup chain becomes: new EPC API -> historic backup by exact
UPRN -> plain prediction. A found record's stable attributes fill the
gaps Landlord Overrides left (overrides always win) and enrich the target
with age band / fuel / TFA band; the persisted predicted-slot row carries
source="expired". Reader unwired or shard miss -> behaviour unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Age band (Table S1 letter), main fuel code, and a ±5% floor-area band —
the first numeric-tolerance filter — each ride _maybe_filter, so an
unresolved attribute (None) is inactive and a starving filter relaxes.
Existing callers pass no new fields and are behaviourally untouched.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The heat-network mirror of keep_existing_off_peak_meter: the override's
2313 default applies only when the replaced system's control is
cross-family (stale); an observed community control survives.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Per-axis choice (decided with Khalim): the kit axis concedes to the
evidence (community schemes skew modern; lodged community certs are
overwhelmingly thermostatted, none lodge 2301), the charging axis stays
flat-rate — usage-linked billing is scheme paperwork an override
cannot see.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
421 slab -> Other storage heaters (0.00); 422/423 integrated -> 0.20;
424/425 screed/timber -> 0.90/0.50 — per the Grid 1 row labels that name
the codes (PDF p.184). Closes the None all-low-rate fallback that
over-credited 7-hour-metered underfloor dwellings.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0048's intended end-state (#1444 Part C): every mapped archetype now
resolves confident companions, so an incomplete set can only mean a new
archetype landed without choosing them — fail loudly at overlay time.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The last real archetype on the companion-gap log; the log test now
simulates a future incomplete archetype (warm-air heat pump, Group 5
control deliberately unmapped).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
_u_brick_thin_wall_age_a_to_e's `<= 280` check put an uninsulated solid-
brick wall of exactly 280mm in the "200 to 280mm -> 1.7" row; RdSAP 10
§5.7 Table 13 (spec PDF p.41) shares 280 as an unlabelled edge between
that row and "280 to 420mm -> 1.4", so the table text alone doesn't say
which row owns it.
Found by building cert 100031768368 (280mm exactly, band C) in Elmhurst
and comparing every worksheet line to the calculator: volume/ACH/floor/
doors matched exactly, but the wall didn't (1.70 vs Elmhurst's 1.40)
despite an identical input crosswalk. Initially reverted a first attempt
at this fix when it appeared to regress an already-pinned cert
(217091901, band A, also nominally 280mm, previously "confirmed" at
U=1.70) — but that cert's build script never actually set a wall
thickness field, so its shared Elmhurst assessment had silently
inherited a stale 260mm from an earlier build. Fixed that build script
and rebuilt with the correct 280mm entry: Elmhurst's worksheet now also
gives U=1.40, matching 100031768368 and confirming the fix rather than
contradicting it.
Both certs move to (near-)exact lodged matches: 100031768368 59.12 ->
61.21 (lodged 61, within 0.5); 217091901 60.82 -> 61.59 (lodged 62,
exact). Corpus gauge 77.8% -> 78.6% within-0.5, MAE 0.636 -> 0.627 (14
corpus certs lodge exactly 280mm solid brick). TDD'd, 46 pins + full
suite green (2310 passed).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>