Reference the calculator-side wall_construction=6 disambiguation issue from the
strict-xfail tripwire and ADR-0019, so the blocker is traceable both ways.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 18:29:05 +00:00
Khalim Conn-Kowlessar
ea4534f3af feat(modelling): system-built walls take EWI+IWI (blocked on basement-code fix)
System-built (precast/no-fines concrete) takes both solid-wall Options like
solid brick (ADR-0019), keyed on `wall_construction == 6` (WALL_SYSTEM_BUILT,
Elmhurst `SY`). A basement-suitability guard (`main_wall_is_basement`) is added
since a below-ground basement wall is never EWI/IWI-suitable.

This is currently inert: `B Basement wall` also maps to 6 (mapper.py:2100) and
`main_wall_is_basement` is derived as `wall_construction == 6`, so every code-6
wall reads as basement and is guarded out — the live cohort is unchanged. The
system-built EWI/IWI cascade pin is committed as a strict-xfail tripwire that
flips green the moment the calculator disambiguates system-built from basement
(MAIN wall_construction==6 with main_wall_is_basement False). `wall_construction
== 8` is Park home, not system-built — not keyed.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 18:26:08 +00:00
Khalim Conn-Kowlessar
1c7997c471 feat(modelling): solid-wall generator offers EWI+IWI for solid brick
Slice 2a. New recommend_solid_wall emits one Main-wall Recommendation carrying
External + Internal wall-insulation Options for an uninsulated (wall_insulation
_type=4) solid-brick (wall_construction=3) main wall, each priced at the heat-
loss wall area. Cascade pin: the generator's EWI and IWI Options reproduce
their respective re-lodged afters at abs(diff) <= 1e-4.

Detection keys on wall_construction code, not description (ADR-0019 note
corrected): the Elmhurst ingestion path leaves walls[].description empty, so
the code is the only cross-path signal; codes 1-5 are consistent.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 15:28:15 +00:00
Khalim Conn-Kowlessar
da69dc27fd docs(modelling): wall-insulation eligibility + conservation-status ADRs
Captures the grill-with-docs session for solid-wall insulation: CONTEXT.md
gains EWI/IWI Measure Types + the Wall Insulation Eligibility rule (+ a
flagged-ambiguity that the three planning flags stay distinct, never recollapsed
to legacy restricted_measures). ADR-0019 records the eligibility policy (cavity
-> cavity only; brick/system -> IWI+EWI; timber -> IWI only; cob/stone -> none;
conservation/flat block EWI, listed/heritage block both). ADR-0020 records
conservation/listed/heritage as three distinct Property attributes sourced by
extending the geospatial S3 repo (flags co-located with lat/long).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>