Tighten the recommendation/plan vocabulary off generic str:
MeasureOption.measure_type and PlanMeasure.measure_type are now MeasureType
(also _GlazingTarget.measure_type, MeasureDependency.triggers ->
frozenset[MeasureType], and the optimiser's chosen/required-type locals).
Because MeasureType is a StrEnum the change is transparent to persistence
(the `recommendation` varchar column), the optimiser group-by key, and every
`== "solar_pv"`-style comparison — so pyright now enforces the enum at every
construction site with no runtime behaviour change.
The catalogue boundary stays str: ProductRepository.get(measure_type: str)
and Product.measure_type are unchanged (they map arbitrary DB/JSON rows), so
the fake product repos in tests need no edit. Test construction helpers coerce
their str arg via MeasureType(...); direct constructions use members.
Suite green: tests/domain/modelling + orchestration + harness 253 pass + 3
xfail; pyright clean on production + tests (pre-existing moto + property-
override-rowcount baselines untouched).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Introduce domain/modelling/measure_type.py — a StrEnum with one member per
modelled measure (the 15 the generators emit). A StrEnum so each member *is*
its string value: it persists straight into the `recommendation` varchar
column, is the optimiser's group-by key, and compares equal to the catalogue /
EPC strings — so it replaces the per-generator string constants with no
persistence or optimiser change.
Repoint every generator's measure-type constant/literal to a MeasureType
member (wall, solid_wall, roof, floor, glazing, lighting, ventilation,
heating, solar). Field annotations stay `str` for now; tightening them to
MeasureType is the next slice.
This is the enum the historical engine deferred (engine.py:970
"TODO - formalise property measure types into an enum") and the vocabulary the
forthcoming `considered_measures` allowlist will speak (mirroring the legacy
`inclusions`).
Suite green: tests/domain/modelling + orchestration + harness 253 pass + 3
xfail; pyright clean on the enum + generators.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
With the mapper now in main, cert 001431 parses: it lodges four single-glazed
windows — codes 1 ("Single") and 15 ("single glazing, known data", a single
pane with manufacturer U/g). The generator only detected code 1, so it missed
two panes. Detect {1, 15}; set the secondary target to code 11 ("Secondary
glazing - Normal emissivity", what the cert re-lodges; score-neutral vs 7 but
exact).
A deterministic green pin proves the overlay reproduces the after's 14 windows
exactly. The full-SAP before->after pins are xfail(strict) tripwires: the
overlay nails the windows, but the measure also re-lodges percent_draughtproofed
84->100 (sealed units draught-proof the replaced openings) plus a ~0.4 SAP
fabric residual the overlay doesn't model yet — a glazing-measure coupling to
close later.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the glazing generator (ADR-0022): a conservation/listed/heritage
protection (PlanningRestrictions.blocks_external) hard-picks secondary_glazing
instead of double_glazing -- an internal second pane, since the external units
can't be replaced on a protected building. Each single-glazed window upgrades
to the secondary target pinned from cert 001431 (glazing_type=7, u_value=2.90,
solar_transmittance=0.85 -- the outer single pane still drives solar gain).
The before/after cascade pins for both measures remain deferred behind the
glazing-label mapper coverage (owned by another agent).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The glazing Recommendation Generator (ADR-0022): detect single-glazed
windows (SAP10.2 Table U2 code 1) and emit one "Windows" Recommendation whose
single Option rewrites every single-glazed window to the double-glazing target
pinned from cert 001431's before->after (glazing_type=5, u_value=1.40,
solar_transmittance=0.72). The overlay writes the per-window U/g into
WindowTransmissionDetails because the calculator consumes those directly.
Priced as a flat per-window average x count. No single-glazed windows -> None.
Planning gate (-> secondary) and the before/after cascade pins land next; the
pins are blocked on glazing-label mapper coverage (owned by another agent).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>