A room-in-roof carries its insulation on its own sloping/stud/gable surfaces
(RdSAP 10 §3.10, Table 17/18), which the roof overlay's flat
roof_insulation_thickness bump cannot model. Without a guard a RR with an
uninsulated loft fell through to the loft fallback and mis-recommended 300 mm
loft insulation. Return None when the main part lodges a sap_room_in_roof,
deferring until a dedicated RR branch lands (ADR-0021).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 (ADR-0021). `recommend_roof_insulation` now owns the loft branch as the
fallback — a plain pitched loft, a thatched roof (the covering doesn't block
insulating the loft floor), or an unlodged roof type all take loft (joist)
insulation at 300 mm when `roof_insulation_thickness == 0`. Sloping is tested
first; a no-access roof gets nothing. Retired the standalone
`recommend_loft_insulation`; the orchestrator and its tests now call the
dispatcher.
Pinned: thatch before→after (None→300) reproduces at 1e-4; the existing loft pin
still holds through the dispatcher. Behaviour-preserving on the golden cohort
(roof measure unchanged: none across all 57) — the dispatch is strictly more
precise (won't fire loft on a sloping/no-access roof).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
domain/modelling/ had grown to 15 flat modules. Group the behavioural ones into
subpackages — generators/ (wall/roof/floor Recommendation Generators), scoring/
(overlay applicator, package scorer, role-1/3 scoring), optimisation/ (optimiser
+ measure dependency) — and leave the shared value-object vocabulary
(recommendation, plan, scenario, product, contingencies, simulation) flat at the
top, since it is imported everywhere. Pure move + import-path rewrite across 89
import sites; no behaviour change. 136 pass, pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes #1158 end-to-end. recommend_loft_insulation now emits a
300 mm overlay (was 270 mm). The Elmhurst before/after re-lodgement of
the loft-insulation measure on cert 001431 lodges the after-cert at
300 mm roof insulation; pinning before→overlay→after requires the
overlay to match that depth — at 270 mm the cascade left a +0.173 SAP
residual, at 300 mm it closes at delta 0.000000 on SAP/CO2/PE.
Adds test_loft_overlay_reproduces_the_relodged_after and updates the
roof generator unit test's thickness assertion to 300.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_loft_insulation(epc, products) detects an uninsulated main loft
(SapBuildingPart.roof_insulation_thickness == 0) and emits a
Recommendation("Roof") with one loft_insulation Option carrying the overlay
(roof_insulation_thickness = 270 mm, the recommended top-up) and a priced
Cost (roof area x the Product's fully-loaded unit cost + contingency).
- building_geometry.roof_area(epc, identifier): the part's greatest
per-storey floor area (RdSAP 10 §3.8). Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains roof_insulation_thickness; the generic Overlay
Applicator writes it with NO change (validated by the tracer) — the
deep-module field-fold paying off.
- loft_insulation contingency (0.10) added.
Progress on #1158 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and the parser fix. Four behaviour tests
(geometry pin; detect / none / cost). pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>