Three more pre-existing failures (present at 9ee38211, before this branch's
recent commits; same family as the orchestration multi-measure re-pin) —
golden-cert plan expectations that predate the ASHP generator (ADR-0025)
and the optimiser folding forced dependencies into candidate gain (ADR-0016):
- test_console: a multi-measure plan now leads with air_source_heat_pump,
not cavity_wall_insulation (which is dropped — its forced ventilation makes
the pair net-negative). Assert a measure actually in the package.
- test_report 0330: package is now {solid_floor_insulation, air_source_heat_
pump}; cavity_wall + forced mechanical_ventilation correctly excluded.
- test_report 0036: gain-maximising package is now {solid_floor_insulation,
low_energy_lighting}.
Same verified-correct optimiser evolution as 077e3a39 (cavity_wall +2.9 SAP
alone but its forced fabric→ventilation dep drags the pair net-negative).
Re-pin to the actual packages + their trigger fields; the forced wall→vent
edge stays covered by test_measure_dependency / test_optimiser.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Orchestrator runs recommend_secondary_heating_removal; report._triggers_for
explains it via the lodged secondary_heating_type; harness catalogue + ARA seed
price it. Re-pins the golden/integration plans it shifts: it is a cheap (\£250)
SAP lever, so on gas-main certs lodging an electric secondary (691) it displaces
the \£12k ASHP (0330, 0036) or joins the all-beneficial-measures package (000490,
where its marginal SAP is 0 under the category-4 ASHP but the heater is still
physically removed). Consistent with the optimiser's existing kitchen-sink
package behaviour.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:
- system_tune_up — standard controls (programmer + room thermostat +
TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned — time-and-temperature zone control (code 2110, type 3):
more SAP uplift for more cost
Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.
Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).
Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the `gas_boiler_upgrade` branch to `report._triggers_for`, mirroring the
generator's eligibility guard so a cohort report explains why the boiler upgrade
fired: the wet-boiler SAP code, the mains-gas connection that makes the gas
end-state installable, and the cylinder presence that shapes the bundle (combi
vs regular + cylinder fixes).
No golden API cert selects the boiler upgrade (it competes with — and on houses
loses to — the ASHP bundle within the one heating Recommendation), so the branch
is covered by a direct `_triggers_for` unit test, following the repo pattern for
testing internal helpers (cert_to_inputs).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The efficient Vaillant aroTHERM plus 5 kW (ADR-0025) now raises SAP even on gas
dwellings, so the Optimiser selects the ASHP bundle far more often -- a deliberate
product shift (user-confirmed). Updated the integration/harness tests:
- ARA multi-measure: ASHP is additive to the kept fabric package -> add to set.
- ARA listed_uprn: is_listed blocks walls AND ASHP (blocks_internal); the gate is
now observable via ASHP (selected unrestricted, blocked listed).
- report three-measures: ASHP + solid-floor displace the fabric stack; assert
their triggers (property_type, main_heating_category / floor).
- console hhr + solid_wall coverage tests: assert the measure is OFFERED as a
candidate (the wiring/eligibility intent), since ASHP now out-competes them in
selection; also assert the optimised package leads with ASHP.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the lighting generator (ADR-0023): run recommend_lighting in
_candidate_recommendations (no planning gate). Price low_energy_lighting in the
offline catalogue + contingency table (0.26, the legacy rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both. A run_modelling test pins
the wiring end-to-end (an incandescent-lit dwelling gets the LED upgrade in the
optimised package).
Downstream updates, all because lighting now fires on any cert with non-LED
bulbs: report.py gains the low_energy_lighting trigger (the non-LED counts); the
two golden-cert report tests and the multi-measure integration test now expect
low_energy_lighting alongside the fabric measures (the sample/golden EPCs lodge
low-energy-unknown bulbs); first-run integration seeds a low_energy_lighting
MaterialRow.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
format_report_csv emits one comma-safe row per property: the calculator-error
fields (lodged/calculated/Δ/flag), the Plan headline figures (baseline+post
SAP/band, measures, cost+contingency, bill & CO2 savings, valuation %), the
flattened measure triggers, and any captured error — sortable in a spreadsheet
for a large dump.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
format_report_markdown emits: (1) cohort parity stats + a per-property
lodged-vs-calculated table flagging |Δ| > 0.5 (errors shown inline),
(2) Plans + costings (SAP/band jump, cost + contingency, bill & CO2 savings,
valuation uplift), (3) each fired measure with the EPC attributes that
triggered it.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
build_property_reports models a dump in order (errors captured per-cert);
parity_report_for aggregates the lodged-vs-calculated SAP across the cohort
into the existing ParityReport (MAE/RMSE/bias/worst-N), excluding certs that
couldn't be mapped or scored. Residual convention is the calculator's own
(predicted - actual), the negative of PropertyReport.sap_error.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Section 3 of the report: build_property_report now runs the Modelling stage
and, for every Plan Measure, records the EPC attribute(s) that caused its
generator to fire (MeasureTrigger) — wall_construction/insulation for cavity
fill, roof thickness for loft, floor thickness/construction for floors, the
absent mechanical kind for ventilation. Modelling raises are captured as
plan_error, independent of the calculator-error capture.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Section 1 of the property inspection report: PropertyReport compares the
cert's lodged energy_rating_current to Sap10Calculator's un-rounded SAP and
flags |Δ| > 0.5 (the ADR-0010/0013 shadow-validation design target). A
mapping/scoring raise is captured per-cert as calculator_error, never
propagated, so one bad cert can't abort the sweep.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>