RdSAP 10 §5.11.4: a pitched roof lodging thickness "NI" with description
"...insulated (assumed)" was billed at the §5.11.4 observed-retrofit
50 mm row (U 0.68) while the SAME description lodged with "ND" fell
through to the Table 18 age-band default (0.40 for bands A-G). The
ND-vs-NI sentinel is lodging-software noise; "(assumed)" means the
insulation PRESENCE is an age-band assumption, not an observed
retrofit, so Table 18's "thickness cannot be determined" clause
governs both forms. The bare "insulated" description (observed
retrofit, no qualifier) keeps the 50 mm row.
Evidence: the 27-cert loc4+NI corpus cohort was systematically
under-rated (~-1 SAP; zero positive movers among "(assumed)" certs),
vs the 102-cert loc4+ND cohort already on Table 18 at ~0 bias.
Gauge: within-0.5 74.2% -> 75.5%, SAP MAE 0.721 -> 0.708, CO2 MAE
0.09 -> 0.074, PE MAE 3.5 -> 3.2 (floors ratcheted). Unit-pinned in
test_rdsap_uvalues (assumed -> Table 18; bare-insulated -> 0.68
regression guard); integration pin in test_heat_transmission updated;
RealCertExpectation pinned for 10094975827 (66 = lodged, was -1.87).
Ledger: C002 103001004 deferred pending Elmhurst arbitration
(single-immersion off-peak pricing + declared cylinder loss vs
Table-2); C006 quadruplet marked ⚠ (LIG-21.0 software honours lodged
0 extract fans literally vs the Elmhurst-validated 0=unknown->default
convention, worksheet case 46).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Setup for the RdSAP-21.0.1 corpus gauge campaign (74.2% within-0.5,
SAP MAE 0.721 at HEAD, 1000/1000 computed):
- scripts/corpus_1000/build_worklist.py — runs all 1000 corpus certs
through the gauge's own path (from_api_response -> Sap10Calculator),
ranks |engine - lodged| descending, clusters by dwelling signature,
and (re)writes scripts/corpus_1000/worklist.md preserving per-cert
statuses and notes. 258 certs outside 0.5 in 249 clusters.
- C001 (worst cert, Δ +23.9): uprn 4510053280, ground-floor flat 47 m²
on ASHP PCDB 100053 (Mitsubishi Ecodan 5 kW, PSR table 0.2-2.0).
Dwelling PSR 2.031 -> SAP 10.2 N2 footnotes 44/45 heat-pump extension
(reciprocal interpolation toward 100% at 2x largest PSR) = 305%
space efficiency, which accredited Elmhurst also applies (golden
case 56, record 100061). The LODGED software instead treated the
out-of-range record as invalid and billed 100% direct electric +
standard schedule (reproduces lodged CO2 to 1%). Lodged-software
methodology gap, worklist ⚠, engine untouched; observed engine 75
pinned in test_real_cert_sap_accuracy.
Gauge floors unchanged (no engine change).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>