recommend_floor_insulation(epc, products) detects an uninsulated ground floor
(SapBuildingPart.floor_insulation_thickness blank/zero) and its construction
from floor_construction_type — 'Suspended timber' -> suspended_floor_insulation,
'Solid' -> solid_floor_insulation — emitting the matching single Option (a
floor is one construction, like a cavity wall) with the overlay
(floor_insulation_thickness = 100 mm) and a priced Cost (ground-floor area x
the Product's fully-loaded unit cost + contingency).
- building_geometry.ground_floor_area(epc, identifier): the lowest floor's
(floor == 0) area. Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains floor_insulation_thickness (generic Applicator
writes it unchanged). suspended (0.20) / solid (0.26) floor contingencies.
Progress on #1159 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and parser. Four behaviour tests (suspended / solid
/ none / cost) + geometry pin. pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_loft_insulation(epc, products) detects an uninsulated main loft
(SapBuildingPart.roof_insulation_thickness == 0) and emits a
Recommendation("Roof") with one loft_insulation Option carrying the overlay
(roof_insulation_thickness = 270 mm, the recommended top-up) and a priced
Cost (roof area x the Product's fully-loaded unit cost + contingency).
- building_geometry.roof_area(epc, identifier): the part's greatest
per-storey floor area (RdSAP 10 §3.8). Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains roof_insulation_thickness; the generic Overlay
Applicator writes it with NO change (validated by the tracer) — the
deep-module field-fold paying off.
- loft_insulation contingency (0.10) added.
Progress on #1158 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and the parser fix. Four behaviour tests
(geometry pin; detect / none / cost). pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
domain/building_geometry.gross_heat_loss_wall_area(epc, identifier) sums
heat_loss_perimeter x room_height across a building part's storeys — the
heat-loss wall area (party walls excluded by construction), not total
wall area. Lives outside the calculator so Modelling cost quantities can
reuse it; the calculator computes the same quantity inline today and
should be DRY'd onto this later (coordinated with the calculator branch).
Pinned at 45.93 m^2 against the 000490 MAIN part. Toward #1155 cost
(behaviour 4). pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>