Daniel Roth
a7ae408ab2 Report a void property when Abri finds no tenancy for the place 🟥
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-07-27 11:22:28 +00:00
KhalimCK
68a147edac
Merge pull request #1678 from Hestia-Homes/feat/boiler-fuel-archetypes
Oil & solid-fuel boiler archetypes, fuel-resolved (issue #1676)
2026-07-24 14:32:55 +01:00
KhalimCK
d5b94996df
Merge pull request #1677 from Hestia-Homes/feat/roof-sloping-ceiling
Pitched sloping-ceiling roof-type family (closes #1676)
2026-07-24 14:32:42 +01:00
KhalimCK
206ac197ee
Merge pull request #1544 from Hestia-Homes/feat/calico-stock-condition-ingestion
Calico roof-covering stock-condition ingestion (ADR-0064)
2026-07-24 14:31:54 +01:00
Khalim Conn-Kowlessar
0dd164567c Map oil and solid-fuel boilers to their SAP codes and companion set 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-24 09:15:53 +00:00
Khalim Conn-Kowlessar
04774a8888 Map oil and solid-fuel boilers to their SAP codes and companion set 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-24 09:14:33 +00:00
Khalim Conn-Kowlessar
6f8724aa04 Route sloping-ceiling roof descriptions deterministically off the loft ladder 🟩
Compose the party-ceiling and sloping-ceiling guards in the roof
GuardedColumnClassifier so a PitchedWithSlopingCeiling override resolves to the
Pitched, sloping ceiling family instead of being routed onto Pitched, N mm loft
insulation by the LLM (ADR-0066).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:53:56 +00:00
Khalim Conn-Kowlessar
82ac8c341b Compose the party-ceiling and sloping-ceiling roof guards ahead of the LLM 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:50:13 +00:00
Khalim Conn-Kowlessar
02a71feae1 Resolve a measured sloping-ceiling depth to its ladder member 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:48:50 +00:00
Khalim Conn-Kowlessar
870cb04631 Resolve a depthless sloping-ceiling marker to as built 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:47:11 +00:00
Khalim Conn-Kowlessar
6603d98c2c Resolve a depthless sloping-ceiling marker to as built 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:46:49 +00:00
Khalim Conn-Kowlessar
c01f48d4fd Carry the sloping-ceiling insulation depth into the overlay 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:38:00 +00:00
Khalim Conn-Kowlessar
e384e37f5f Carry the sloping-ceiling insulation depth into the overlay 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:26:48 +00:00
Khalim Conn-Kowlessar
9cccf83000 Defer an as-built sloping-ceiling override to the age-band default 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:25:37 +00:00
Khalim Conn-Kowlessar
bec6e17347 Recognise the pitched sloping-ceiling descriptions as roof types 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-23 13:24:28 +00:00
KhalimCK
09c2b93251
Merge pull request #1672 from Hestia-Homes/fix/sap10-accuracy-calc-batch
SAP 10.2 calculator accuracy batch: #1666 / #1667 / #1669 / #1668
2026-07-23 10:04:16 +01:00
KhalimCK
49a36581f0
Merge pull request #1546 from Hestia-Homes/feat/ara-scenario-export
ARA Scenario Export: branded sheet-per-scenario XLSX export (ADR-0065)
2026-07-23 09:34:51 +01:00
Daniel Roth
ae1da26558 Move the PasHub fetcher into the DDD layer structure 🟪
The service was the last one living wholly under backend/. It now follows
the same layering as abri and the other newer services:

  domain/pashub_fetcher/          core file classification, subfolders
  infrastructure/pashub_fetcher/  PasHub client, token getter, wire DTOs
  orchestration/                  PashubFetcherOrchestrator (was PashubService)
  applications/pashub_fetcher/    lambda handler, trigger request, dev tooling

core_files.py is split along the layer boundary: the domain module keeps the
filename/evidence-category classification rules and no longer imports
infrastructure.postgres, while the CoreFiles -> FileTypeEnum translation moves
to infrastructure/pashub_fetcher/core_file_types.py.

Tests move into the tests/ tree by layer. Note this puts them in the only
suite CI currently runs (unit_tests.yml is disabled), so these 73 tests now
execute on PRs for the first time; they were previously reachable only via
the legacy pytest.ini testpaths.

sharepoint_renamer's image now copies just domain/pashub_fetcher/ rather than
the whole service, since SharepointSubfolders is all it needed.

Behaviour is unchanged. tests/ goes 9927 -> 10000 passed (+73, exactly the
tests that moved in); the legacy suite keeps its same 17 pre-existing failures
and 11 errors. tests/test_lambda_packaging.py confirms both changed
Dockerfiles still copy their handler's full import closure.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-22 13:35:54 +00:00
Khalim Conn-Kowlessar
1b742f41aa Derive wet-underfloor responsiveness from RdSAP Table 29 subtype 🟩
Wet underfloor responsiveness was pinned at R=0.75 for the lumped gov-EPC emitter
code 2, regardless of floor construction. SAP 10.2 Table 4d splits it three ways
and RdSAP 10 Table 29 (p.56-57) selects from floor construction + age band:
timber floor 1.0, screed above insulation 0.75, concrete slab 0.25. A
concrete-slab system (solid floor, age A-E) was billed as screed, over-stating
responsiveness (higher MIT) and over-rating the dwelling; R=0.25 was unreachable.

_responsiveness now takes the cert and, for the lumped underfloor code, derives
the Table 29 subtype via _underfloor_responsiveness from the main part's floor
construction + age band: suspended TIMBER -> 1.0; solid A-E -> 0.25 (concrete
slab); solid F-M / suspended-not-timber / unknown / no ground floor -> 0.75
(screed, the prior default, so ambiguous no-ground-floor certs do not move). The
mapper stays a pass-through.

Spec: SAP 10.2 Table 4d (p.170), RdSAP 10 Table 29 (p.56-57). Corpus: MAE
0.570 -> 0.565 (net toward lodged), within-0.5 81.2%. Cert 100100137438 (solid,
band B) 72 -> 69, exactly lodged. Closes #1668 on the API path.

NOTE: the issue's worksheet adjudication (run 100100137438 through accredited
Elmhurst to confirm concrete-slab R=0.25) is still outstanding — it corrects to
lodged 69 exactly, but is not yet Elmhurst-worksheet-confirmed. The Elmhurst
site-notes path (_resolve_elmhurst_underfloor_subtype still raises for solid A-E)
is untouched — no corpus/fixture exercises it; separate follow-up.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-22 13:29:10 +00:00
Khalim Conn-Kowlessar
21faf63c89 Merge remote-tracking branch 'origin/main' into HEAD
# Conflicts:
#	tests/domain/sap10_calculator/worksheet/test_heat_transmission.py
2026-07-22 12:03:52 +00:00
Khalim Conn-Kowlessar
72f3e3a72d Add default-plan export selection + plan_name column (ADR-0065)
A second export selection alongside the per-Scenario one, chosen by
`plan_selection` on the export request:

- "scenario" (default, unchanged): one sheet per Scenario, freshest Plan per
  (property, scenario); scenario_ids required.
- "default" (new): a single "Default Plans" sheet of each home's is_default
  Plan (one-per-property across all Scenarios, ADR-0012/0017) — the portfolio's
  current state, one row per home; scenario_ids ignored.

Repository gains `default_rows_for(portfolio_id, property_ids)`: same read-model
and Effective-EPC join as `rows_for`, with the plan-selection WHERE swapped from
`scenario_id = :scenario_id` to `is_default = TRUE`. Orchestrator branches on
plan_selection; the router validates it and only requires scenario_ids for the
scenario selection. A recipe without plan_selection defaults to "scenario", so
the change is backward-compatible.

Both selections now surface the chosen Plan's `name` as a `plan_name` column.

Tests: repository default_rows_for (scenario-independent selection, plan_name,
non-default excluded); orchestrator default path (one "Default Plans" sheet;
empty selection is a recorded failure). 62 passed, pyright --strict clean.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-22 09:21:38 +00:00
KhalimCK
0e99ad711e
Merge pull request #1662 from Hestia-Homes/fix/floor-to-unheated-space-heat-loss
Bill a flat's floor to an unheated space as semi-exposed
2026-07-22 10:17:26 +01:00
Khalim Conn-Kowlessar
190325b23b Merge remote-tracking branch 'origin/main' into HEAD
# Conflicts:
#	tests/infrastructure/epc_client/test_sap_accuracy_corpus.py
2026-07-22 08:38:04 +00:00
Khalim Conn-Kowlessar
3f6129afc6 Bill a sheltered wall to a stairwell at Ru 2.1, not the corridor 0.5 🟩
RdSAP 10 §5.9 "U-values of sheltered walls" (PDF p.43): a wall between a
flat/maisonette and an unheated buffer takes SAP 10.2 §3.3's U = 1/(1/U0 + Ru),
and Ru depends on the BUFFER TYPE — "Use Ru = 0.5 m²K/W for corridors and
Ru = 2.1 m²K/W for stairwell."

The buffer type is lodged on `SapFlatDetails.heat_loss_corridor` (0-based per
item 1-11, PDF p.70: 0 none, 1 heated, 2 unheated corridor, 3 unheated
stairwell). That field was read NOWHERE under domain/ — corridor presence was
inferred only from a lodged sheltered alternative wall — so every sheltered wall
took the corridor 0.5 and every stairwell flat over-billed its sheltered wall,
under-rating the dwelling.

Distinct from `_SHELTERED_GABLE_ADDED_RESISTANCE_M2K_W`, which is RdSAP 10
Table 4 (p.22) for a room-in-roof sheltered gable — same 0.5, different rule,
deliberately untouched.

Corpus gauge ratcheted UP: within-0.5 78.8% -> 79.8% (+10 certs), SAP MAE
0.626 -> 0.613, PE MAE 2.9 -> 2.8. Failure set and pyright count identical to
main. Portfolio 824 is stairwell-heavy (60 properties at code 3); property
749898 over-bills 4.44 W/K on a 48 m2 flat.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-21 22:02:31 +00:00
Khalim Conn-Kowlessar
0ffc25506e Bill a flat's floor to an unheated space as semi-exposed 🟩
RdSAP 10 §3.12 (PDF p.26), the flats/maisonettes floor rules: "There is no heat
loss through the floor if there is another flat below. Otherwise the floor area
of the flat ... is ... a semi-exposed floor if there are unheated premises below
it (e.g. an enclosed garage) ... Semi-exposed (sheltered) floors are treated as
if they were fully exposed." §5.13 (p.48) confirms the U-value identity: Table 20
applies to exposed and semi-exposed alike.

API floor_heat_loss=2 -> floor_type "To unheated space" set no exposure signal,
so on a mid-/top-floor flat the dwelling-level heuristic (has_exposed_floor=False,
assuming a heated dwelling below) went unopposed and the ENTIRE floor was billed
at 0 W/K. 11 properties across portfolios 796+824, mean +4.02 SAP, 10 of 11
over-rating — we judged dwellings more efficient than the accredited assessment
and would withhold retrofit measures they need.

Exemplars: 750018 space heating -53.2% -> -8.1% vs the cert's own RHI figure,
SAP +8.22 -> +1.16; 749898 -43.0% -> +0.9%, SAP +6.29 -> -1.11.

SCOPED TO FLATS ON PURPOSE. §3.12 is the flats/maisonettes section, and the
accredited Elmhurst worksheet disagrees with Table 20 for a house: golden cert
7536-3827-0600-0600-0276 (detached) lodges floor_heat_loss=2 on its Main part and
the worksheet bills it on the BS EN ISO 13370 ground-floor cascade at U 0.97, not
Table 20's 1.20. An unscoped mapper-level fix broke that pin and the
uprn_100050881708 accuracy pin; the scoped fix leaves both untouched.

No regressions: identical failure set and pyright count vs main; the RdSAP-21.0.1
accuracy corpus gauge is unchanged at 78.8% within-0.5 / MAE 0.625 (correctly —
all 7 corpus certs lodging code 2 are houses).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-21 21:24:25 +00:00
Khalim Conn-Kowlessar
27060f4d81 Band every continuous SAP score through the published-rating rule 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-21 10:11:06 +00:00
Khalim Conn-Kowlessar
149d957248 Publish a half-point SAP rating rounded up 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-21 10:02:44 +00:00
Daniel Roth
dc96cf5aba
Merge pull request #1648 from Hestia-Homes/feature/abri-api-resource-field
Sync third_party_surveyor_identifier deal field from HubSpot
2026-07-20 11:02:11 +01:00
Khalim Conn-Kowlessar
35a0c6e972 Source export fabric from structured SAP fields; fix stale-cert selection
The "latest EPC per UPRN" selection ordered by e.id DESC, but row-id does not
track recency: a gov-EPC cert re-ingested after a PasHub survey lands with a
higher e.id, so the header/perf reads silently picked the stale gov cert (wrong
TFA, lodgement, property_type, current band) on 3 of portfolio 838. Order by the
effective lodgement date (registration -> completion -> inspection) DESC NULLS
LAST, e.id DESC tiebreak.

Compose the descriptive fabric from the structured SAP fields a re-survey lodges
(no gov-EPC prose): walls/roof/floor from the main epc_building_part, heating and
hot water from epc_main_heating_detail + the water-heating codes, decoded with
the SAP engine's own code space (fabric_description.py). Structured fabric wins
where present and falls back to the gov-EPC prose otherwise; windows and lighting
stay on prose (their per-element codes do not reconstruct the dwelling phrase).

Add built_form (epc_property, code-decoded) and property_age_band (building part
construction_age_band -> RdSAP date range) columns.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-18 19:38:12 +00:00
Daniel Roth
18dfda038d tweaks 2026-07-17 13:21:47 +00:00
Daniel Roth
edd4ec00de Make the OpenHousing resource mandatory, dropping the default fallback
The deal's third_party_surveyor_identifier is now required by the log
and amend flows: the trigger contract rejects messages without it
(blank treated as missing, since a blank resource makes OpenHousing
silently drop the appointment), and LogJobRequest/AmendJobRequest carry
it as a required field. The ABRI_RELAY_DEFAULT_RESOURCE fallback and
its config/terraform/workflow wiring are removed as dead code.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-17 13:13:28 +00:00
Daniel Roth
c8fe4585bf Send the deal's third-party surveyor as the OpenHousing resource
Carry third_party_surveyor_identifier on the Abri trigger message and
through dispatch into the log and amend flows, booking the job against
that resource. LogJobRequest gains the optional resource field
AmendJobRequest already had; the client falls back to the configured
default surveyor when the deal names no third-party resource, so
existing deals behave unchanged.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-17 13:00:47 +00:00
Khalim Conn-Kowlessar
fac64a90cc Bill community-heating DHW at the network fuel rate 🟩
When DHW is supplied by a community heat network (WHC 901/902/914 on a
heat-network main), the network heat -- space AND water -- bills at the main's
Table-12 heat-network rate. The STANDARD-tariff §10a cost path (_fuel_cost)
re-derived the DHW rate inline from the cert-lodged HW fuel, which Elmhurst
defaults to 'Mains gas' (Table 32 code 26, 3.48 p/kWh) on community certs --
under-costing DHW and over-rating SAP. Now inherits the main heat-network rate
via _fuel_cost_gbp_per_kwh, mirroring the .173 inherit already applied on the
legacy/off-peak HW-rate paths. Scoped to community heating, so all other certs
are unchanged; the RdSAP-21.0.1 corpus gauge improves 78.6%->78.9% within-0.5
(MAE 0.628->0.622) with all 195 Elmhurst worksheet pins green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-16 18:38:02 +00:00
KhalimCK
04b7c26f67
PasHub SAP accuracy: infiltration inputs + immersion DHW + lights/lobby/heat-network (#1615)
* Electric-immersion DHW: bill at 100%, not the space boiler's efficiency 🟩

A separate electric immersion heater (SAP water-heating code 903) is 100%
efficient (SAP 10.2 Table 4a) and the space-heating boiler provides no water
heating, so Appendix D2.1 Eq D1 (the boiler seasonal-efficiency cascade) must
not apply to it. But `_water_heating_main` resolves DHW to the SPACE main — a
gas/oil boiler keeps its PCDB record — so three water-efficiency branches in
cert_to_inputs billed the immersion-heated cylinder at the boiler's ~87% summer
efficiency (a mongrel: electric fuel price x gas-boiler efficiency):

  1. the scalar `water_eff = water_pcdb_main.summer_efficiency_pct / 100`,
  2. the SAP §9.4.11 / Table 4c(2) -5pp no-interlock adjustment, and
  3. the Eq D1 (winter, summer) seasonal pair from `pcdb_main`.

Gate all three on `not dhw_is_electric_immersion`; the correct immersion path
(`_water_efficiency_with_category_inherit` -> 1.0, Eq D1 off) then applies,
mirroring the Table 3 zero-primary-loss gate already present for WHC 903.

General bug — fires for any WHC-903 dwelling whose space main is a PCDB gas/oil
boiler. It surfaced via the PasHub campaign's #1600 no-water-heating default
(WHC 999 -> 903) on a gas-combi dwelling: 58 Hackle St M11 4WU, SAP 55.30 ->
57.67 (pre_sap 58, verified 59).

Guardrails: the gov-API RdSAP corpus IMPROVES 78.8% -> 78.9% within-0.5, MAE
0.625 -> 0.622 (a handful of corpus certs with a boiler space main + electric
immersion move closer to accredited) — MAE ceiling ratcheted 0.626 -> 0.625.
Regression pinned in test_cert_to_inputs (RED before / GREEN after). pyright
0-new (cert_to_inputs baseline 30).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>

* PasHub SAP accuracy: thread low-energy lights + draught lobby (from_site_notes) 🟩

Two systematic silent-drops in the PAS Hub `from_site_notes` path, each a field
the gov-API/Elmhurst mappers thread but site-notes dropped, letting a favourable
default reach the SAP-10.2 calculator. Validated against the correct pashub
oracle (property_baseline_performance.effective_sap_score, portfolio 838):
cohort within-0.5 55.1% → 62.6%, MAE 0.599 → 0.521.

- Low-energy lights: when "exact LED/CFL known = No", PAS Hub lodges an aggregate
  "Number of fixed low energy lights?" count. Previously dropped (no dataclass
  field / extractor key / mapper thread) → calculator saw 0 low-energy bulbs and
  applied the pessimistic L5b/L8c no-data default, under-rating SAP. Now threaded
  into low_energy_fixed_lighting_bulbs_count, mirroring from_elmhurst_site_notes.
  ~6% of the cohort; resolves 58 Hackle (−0.43 vs oracle 59 with #1615).
- Draught lobby: _map_sap_ventilation set only the legacy `draught_lobby` field,
  never the canonical `has_draught_lobby` §2 (13) gate the cascade reads, so the
  surveyed lobby was ignored and infiltration over-stated. Now mirrors Elmhurst.

Two other audited levers were REJECTED against the pashub oracle (they matched
the gov-cert/RdSAP convention but pashub does not apply them): percent_draughtproofed
(cohort 30.8%) and the §A.2.2 assumed secondary heater (19.2%). A heat-network
control-code fix (2306→2303 for 16 Bingley) is HELD pending spec/Elmhurst
adjudication — it contradicts ADR-0053; see the NOTE on _PASHUB_HEAT_NETWORK_CONTROL_TO_SAP10.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>

* PasHub heat-network control: room-thermostat-only maps to 2308, not 2306 🟩

The Table 4e Group 3 label "charging linked to use of community heating, room
thermostat only" was mapped to 2306 — the linked-to-use *with-TRVs* code
(control type 3, space charging 1.00). The label explicitly excludes TRVs, so
it is control type 2 / space 1.05 = code 2308/2309 (linked-to-use → DHW 1.00).
2306 asserted TRVs the survey doesn't have and over-rated the cohort's sole
heat-network dwelling (16 Bingley Close 56.89 → 54.01 vs pashub oracle 52).

Verified against SAP 10.2 Table 4e as encoded in cert_to_inputs.py
(_CONTROL_TYPE_BY_CODE 2308→2, space-charging 2308→1.05, DHW 2308→1.00) and the
RdSAP control-label vocabulary in MainheatControlAttributes.py. 2303 (the earlier
audit's guess) is rejected: it is a flat-rate code (DHW 1.05) whose oracle match
was a coincidence of two offsetting spec violations. The residual +2.0 to oracle
52 is the documented SAP-10.2-engine-vs-lodged offset, not a fuel/flags gap
(those were threaded by the #1590 follow-up) — supersedes the ADR-0053 /
HANDOVER_838 "community fuel/flags" attribution.

16 Bingley is the only heat-network fixture in portfolio 838, so this moves one
fixture strictly toward its oracle. Harness ratcheted: within-0.5 0.51→0.58,
MAE 0.625→0.521 (observed 58.5% / 0.520 with all three 2026-07-15 levers).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>

* PasHub SAP accuracy: restore 3 dropped §2 infiltration inputs (from_site_notes)

`from_site_notes` uniquely dropped three ventilation inputs that the gov-API
and Elmhurst sibling mappers all set, causing a systematic cohort-wide SAP
under-rate vs the company's own accredited SAP-10.2 certs
(property_baseline_performance.effective_sap_score, portfolio 838):

1. percent_draughtproofed — never set, so §2(15) window infiltration was
   pinned at its 0.25-ACH worst case on every dwelling. Reconstructed as the
   area-weighted % of draught-proofed windows (mirrors Elmhurst
   `draught_proofing_percent`). Dominant term.
2. Upper-storey +0.25 m joist void — omitted; now added, matching
   `_UPPER_FLOOR_HEIGHT_ADD_M` on the gov-API/Elmhurst paths. This
   RE-ADJUDICATES #1601 ("keep raw"): that call was confounded by the
   then-present draught-proofing drop suppressing every verified dwelling.
3. sheltered_sides — left None → calculator's flat default of 2, which
   over-shelters end/semi/detached (RdSAP §S5 = 1/1/0). Now derived from
   built form.

The three are NON-ADDITIVE — each overshoots alone (which is why all three
were previously rejected individually) — but together they land all 7
verified ground-truth dwellings toward truth (none regress) and every built
form near zero. Cohort 62.1% -> 83.3% within-0.5, MAE 0.507 -> 0.377.

Guardrails: gov-API RdSAP corpus unchanged (78.9%, these are from_site_notes-
only helpers). pashub harness 58.5% -> 79.5% / MAE 0.520 -> 0.389; ratchets
tightened 0.58->0.78 and 0.521->0.40. pyright zero-new (mapper baseline 39).
New focused tests in TestFromSiteNotesInfiltrationFixes cover all three
fields incl. area-weighting and the built-form shelter map; goldens updated.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>

---------

Co-authored-by: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-16 00:30:55 +01:00
Daniel Roth
589eedba8a Cite C6 rather than C3.2 for the heat-network standing charge rule 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 13:53:59 +00:00
Daniel Roth
43e69f159a Charge the C6 half heat-network standing charge on a water-only dwelling's off-peak fuel bill 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 13:45:21 +00:00
Daniel Roth
4472e47ed4 Charge the C6 half heat-network standing charge on a water-only dwelling's fuel cost worksheet 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 13:41:17 +00:00
Daniel Roth
cc84a091e6 Include the C6 half heat-network standing charge on top of a water-only dwelling's fuel standing 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 13:32:34 +00:00
Daniel Roth
8a96003d45 Include the C6 half heat-network standing charge on top of a water-only dwelling's fuel standing 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 13:31:33 +00:00
Daniel Roth
7e355ce2ea Treat water-only heat-network primary pipework as insulated 🟩
SAP 10.2 Table 3 ("For heat networks apply the formula above with p = 1.0
and h = 3 for all months") and §4.3's "insulated pipework" literal both
scope on the DHW source, so a water-only network gets the same row as a
network space main. Was falling back to the RdSAP §3 age-band default —
band E → p=0, h=5 — billing 64.58 kWh in January against the spec's 23.26.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 10:29:48 +00:00
Daniel Roth
ef44a744a3 Accrue Table 3 primary-circuit loss for water-only heat-network cylinders 🟩
SAP 10.2 §4.3 (p.24) scopes itself to "where hot water is provided by a
heat network" and requires the Table 3 primary loss, so the gate keys on
the DHW source. Checked off the WHC before the main-keyed branches so a
non-boiler space main (cert 9093's warm air) can't zero it out.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 10:28:19 +00:00
Daniel Roth
353ebe5556 Price water-only heat-network DHW without a plant-efficiency divisor 🟩
SAP 10.2 §4.3 (p.24) puts the water-heating efficiency in the Table 12
heat price, and C4 (p.53) scopes the plant efficiency to CO2/PE only, so
worksheet (310) = (64) × (305a) × (306) carries no efficiency term. The
dwelling-side divisor was applying it a second time.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 10:24:34 +00:00
Khalim Conn-Kowlessar
65fb4fabad Extract per-Property row construction behind a shape helper 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:16:27 +00:00
Khalim Conn-Kowlessar
9c1e79efc6 Carry Property identity and Effective-EPC fields onto the export row 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:15:40 +00:00
Khalim Conn-Kowlessar
c2aca6d2e6 Carry the Plan's post-works figures onto the export row 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:14:41 +00:00
Khalim Conn-Kowlessar
91c88743f7 Pivot solar PV with a battery to its own column 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:13:22 +00:00
Khalim Conn-Kowlessar
a6eaac5fe3 Total each Property's retrofit cost from its measure costs 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:12:23 +00:00
Khalim Conn-Kowlessar
b52b38e6f3 Roll up each Property's SAP points and savings across its measures 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:11:36 +00:00
Khalim Conn-Kowlessar
23ff1e73a8 Guarantee every measure column on every scenario sheet 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:10:16 +00:00
Khalim Conn-Kowlessar
c4e1cc4229 Pivot a Property's measure cost onto its scenario-sheet column 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-13 23:09:00 +00:00