Setup for the RdSAP-21.0.1 corpus gauge campaign (74.2% within-0.5,
SAP MAE 0.721 at HEAD, 1000/1000 computed):
- scripts/corpus_1000/build_worklist.py — runs all 1000 corpus certs
through the gauge's own path (from_api_response -> Sap10Calculator),
ranks |engine - lodged| descending, clusters by dwelling signature,
and (re)writes scripts/corpus_1000/worklist.md preserving per-cert
statuses and notes. 258 certs outside 0.5 in 249 clusters.
- C001 (worst cert, Δ +23.9): uprn 4510053280, ground-floor flat 47 m²
on ASHP PCDB 100053 (Mitsubishi Ecodan 5 kW, PSR table 0.2-2.0).
Dwelling PSR 2.031 -> SAP 10.2 N2 footnotes 44/45 heat-pump extension
(reciprocal interpolation toward 100% at 2x largest PSR) = 305%
space efficiency, which accredited Elmhurst also applies (golden
case 56, record 100061). The LODGED software instead treated the
out-of-range record as invalid and billed 100% direct electric +
standard schedule (reproduces lodged CO2 to 1%). Lodged-software
methodology gap, worklist ⚠, engine untouched; observed engine 75
pinned in test_real_cert_sap_accuracy.
Gauge floors unchanged (no engine change).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>