RdSAP 10 §2 (Ventilation, "Walls" row): "Structural infiltration: 0.25
for steel or timber frame or 0.35 for masonry construction ... System
build: treated as masonry." `_is_timber_or_steel_frame` wrongly included
wall_construction code 6 (system build) alongside code 5 (timber frame),
handing system-build dwellings the 0.25 structural ACH instead of 0.35.
On the cat-10 room-heater fixture (ref 001431, walls SY System Build →
code 6) this under-stated the infiltration rate (18) by exactly 0.10
(0.45 vs worksheet 0.55), dropping the effective air change (25), the
ventilation heat loss (38)m = 0.33 × (25)m × (5), and the heat-transfer
coefficient (39) — so space-heating demand (98) came out 404 kWh low
((211) 11158.6 vs worksheet 11563.2). Restrict the 0.25 branch to code 5
only; code 6 (and everything else) is masonry at 0.35.
Pins the rating-block (38)m ventilation heat loss mean = 83.3613 W/K at
abs 1e-4 and asserts the classifier treats the system-build wall as
masonry. §4 suite green (2415 passed, 1 skipped); no existing fixture
relied on system-build → 0.25.
Residual after this slice: SAP +0.03 / cost -£0.95 — a small fabric (33)
gap (-0.15 W/K) plus lighting (232) +1.0 kWh remain as separate causes.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Water heating SAP code 909 (electric instantaneous) and 907 (single-point
gas) heat water at the point of use, serving one outlet with no
distribution pipework. Per SAP 10.2 §4 (p.23, l.1416): "'Single-point'
heaters, which are located at the point of use and serve only one outlet,
do not have distribution losses either." So worksheet (46)m = 0 and the
heat-required line collapses to SAP 10.2 worksheet l.7704
(62)m = 0.85 × (45)m + (46)m + (57)m + (59)m + (61)m
= 0.85 × (45)m (all loss terms zero for a no-cylinder system).
`distribution_loss_monthly_kwh` already supported the
`is_instantaneous_at_point_of_use` flag (and its docstring already named
codes 907/909), but `water_heating_from_cert` hard-coded it to False, so
the cascade applied (46)m = 0.15 × (45)m to single-point heaters. That
0.15 distribution loss exactly cancelled the 0.85 reduction, leaving
(62)m = (45)m. On the cat-10 room-heater fixture (ref 001431, code 909)
that over-stated the water fuel (219) as 2082.6250 instead of the
worksheet's 1770.2313, and inflated the (65)m heat gains (692.47 vs
worksheet 442.55) which in turn suppressed space-heating demand.
Thread the cert's existing instantaneous flag (`_INSTANTANEOUS_WATER_CODES`
= {907, 909}) through `_water_heating_worksheet_and_gains` into both the
demand-pass and final `water_heating_from_cert` calls.
Pins (219) water fuel = 1770.2313 at abs 1e-4 via the extractor → mapper →
rating cascade. §4 suite green (2414 passed, 1 skipped); no existing
fixture exercised the 907/909 path. The residual space-heating fuel gap
((211) 11158.59 vs worksheet 11563.17) this exposes is a separate cause —
next slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
cert 001431's §11 lodges 17 windows but only 14 surfaced, via two distinct gaps:
1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
laid out as a standalone keyword line with the U-value on the next line
and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
"<source> <U>" Manufacturer-line shape. Now anchored by a standalone
data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
the absent frame cell.
2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
(U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
backstop even though both are lodged on an "External wall". A window
lodged on a wall is vertical by definition; guard the U-value backstop so
it only fires when location/BP give no roof signal.
With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows.
Re-homed onto the mapper-validation line from feature/bill-derivation
(orig f68cea27); the modelling-only regression test
(tests/domain/modelling/test_window_extraction_001431.py) stays on
bill-derivation. KNOWN: the mapper guard breaks cert 000516's
test_summary_pdf_mapper_chain pins (W6 U=3.10 routing) — must be resolved
before this PRs to main.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The fuel codes the calculator now puts on SapResult are its own codes — raw
gov-API enums or already-Table-32, depending on the source mapper (ADR-0015).
sap_code_to_fuel now runs the code through table_32.to_table_32_code
(promoted from private _to_table_32_code) — T32-first, then API-translate,
the SAME normalization the calculator's pricing/CO2 helpers use — before the
Table-32 -> Fuel dispatch, so the bill's carrier matches what the calculator
billed (incl. the API/T32 collision codes, e.g. 20 = wood-logs not heat-net).
Falls back to the raw code for billing fuels the price table omits (the 41-58
heat-network range), which resolve to HEAT_NETWORK -> UnpricedFuel — stricter
than, and intentionally divergent from, the calculator's lossy
default-to-mains-gas for an unpriced code (ADR-0014 §5).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0014 BillDerivation attributes each end-use (HEATING / HOT_WATER /
SECONDARY / APPLIANCES / COOKING) to a fuel carrier and credits PV
export. SapResult already carried the per-end-use kWh but not WHICH
fuel each end-use burns, nor the annual exported kWh — so a downstream
SapResult->EnergyBreakdown adapter could not pick the right tariff.
Surfaces five output-only fields, threaded exactly like the recently
merged appliances/cooking change (2f039aeb):
main_heating_fuel_code RdSAP10 Table 32 / SAP 10.2 Table 12 fuel
main_2_heating_fuel_code code column (the lodged fuel code, e.g.
secondary_heating_fuel_code mains gas 26). None when the corresponding
hot_water_fuel_code system is absent / fuel not resolvable.
pv_exported_kwh_per_yr SAP 10.2 Appendix M1 §3-4 annual export kWh
(0.0 when no PV).
cert_to_inputs.py populates the four fuel codes from the existing
resolvers the cost/CO2 cascade already uses — `_main_fuel_code`,
`_secondary_fuel_code`, `_water_heating_fuel_code` (not reinvented);
Main 2 is the second `main_heating_details` entry, guarded for length.
There is a single CalculatorInputs construction site (cert_to_demand_
inputs delegates to cert_to_inputs). `pv_exported_kwh_per_yr` already
existed on CalculatorInputs; SapResult collapses its Optional to 0.0.
HARD CONSTRAINT honoured — output-only, zero rating drift. These fields
do NOT feed ECF / total_fuel_cost_gbp / co2_kg_per_yr / primary_energy_*
/ sap_score / any monthly value. Every golden-fixture, Elmhurst e2e
SapResult pin, section cascade pin, and heating-corpus residual stays
byte-identical: calculator suite 1658 -> 1661 passed (+3 new tests),
4 skipped, 0 failed before and after. pyright net-zero (51 -> 51 in
domain/; no new errors in the touched test files).
New tests: a synthetic threading test (four fuel codes + PV export pass
unchanged through calculate_sap_from_inputs; None PV collapses to 0.0)
and a cert-level pin (mains-gas combi cert 000516 -> main fuel code 26,
no Main 2, secondary 30, HW 26). Synthetic CalculatorInputs / SapResult
fixtures updated for the new SapResult fields (defaults cover Inputs).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`test_epc_property_data_round_trips[RdSAP-Schema-21.0.1]` failed with
`sap_roof_windows: None != []` — a normalization mismatch, not lost data.
The 21.0.1 fixture has no roof windows, but the 21.0.1 API mapper emitted
an empty list `[]` while the domain field defaults to None
(`Optional[List[SapRoofWindow]] = None`), the 21.0.0 path yields None, and
the persistence reload yields None (roof windows aren't stored yet — doc
§2.4). Append `or None` so "no roof windows" has one canonical
representation across mapper paths and the round-trip.
No data-loss change: a cert WITH roof windows still produces the
populated list (test_golden_fixtures pins a 6-roof-window cert), and the
§2.4 roof-window persistence gap remains separately tracked. Full
sap10_calculator + documents_parser + epc-repository suites pass (2420);
pyright unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the `_api_resolve_wall_insulation_thickness` tests
passed literals straight into the Act call. Bind them as named variables
in Arrange (`lodged_thickness`, `measured_value_mm`, `ni_lodgement`) and
have the asserts reference those names, so the Act line reads
declaratively and the inputs/expectations are stated once. Applied to all
three tests in the class. No behaviour change; tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the simplified room-in-roof branch used cryptic
locals. Rename for clarity (behaviour-unchanged; the geom dict keys and
the builder-function locals are untouched):
rr_a_rr -> rr_roof_area (the worksheet's simplified A_RR)
rr_common -> rr_common_wall_area
rr_gable -> rr_gable_area
a_rr_final -> rr_residual_roof_area (leftover roof-going area after
deducting perimeter walls/gables
/rooflights — takes the roof U)
Names now mirror the `rr_*_area_m2` geom keys they read from and say
"area of what". Added a one-line note that `rr_roof_area` is the RdSAP 10
§3.10.1 A_RR. Pyright unchanged; 1087 heat-transmission/cascade-pin tests
pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the SQLModel column was Optional[str], but the
domain `SapBuildingPart.wall_insulation_thickness` is Optional[Union[str,
int]] — `_api_resolve_wall_insulation_thickness` returns an int mm when the
API lodges `wall_insulation_thickness == "measured"` (SAP 10.2 §5.7 /
Table 8). The plain str column round-trips that int back as the string
"100", corrupting the Table 8 insulated-wall U-value lookup.
This column was missed in the round-trip-fidelity §1 JSONB sweep
(#1129) — its `Union[str, int]` sibling `roof_insulation_thickness` was
converted, but `wall_insulation_thickness` was not, and no 21.0.0/21.0.1
fixture lodges "measured" so the gap stayed latent. Convert to JSONB
(matching `roof_insulation_thickness` / `flat_roof_insulation_thickness`),
align the column type to Optional[Union[str, int]] (also removes a pyright
type-mismatch), record it in the migration doc §1, and add a round-trip
guard test asserting an int survives as an int (fails as '100' == 100 on
the old str column).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): `_parse_thickness_mm` handles a None input and
returns Optional[int], so its call-return locals — and the Optional[str]
raws they read from `_local_val` — read clearer when annotated. Annotates
`thickness_raw`/`ins_thickness_raw: Optional[str]` and
`thickness_mm`/`insulation_thickness_mm: Optional[int]` at all four call
sites (_wall_details_from_lines, _alternative_walls_from_lines,
_roof_details_from_lines, _floor_details_from_lines), plus the adjacent
`u_val_raw`/`default_u` Optional pair in _floor_details_from_lines for
consistency. Matches the project convention of typehinting call-return
locals. No behaviour change; pyright clean, 569 parser tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Captures the diagnosis so the next agent doesn't re-derive it: what's done
(S0380.235-237), what's confirmed correct (calculator U-adjustment, party
wall, glazing labels), the worksheet pin targets, and the two open causes —
crucially the 000516 trap (byte-identical Summary data classified as a roof
window there but a wall window here, so flipping the U>3 rule regresses
000516). Includes a rebuildable tracer recipe.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes the secondary-glazing family. S0380.235 mapped the unknown-data
(7) and normal-emissivity (11) secondary variants; the RdSAP-21.0.1
`glazed_type` enum also defines code 12 "secondary glazing, low
emissivity", whose Elmhurst §11 label "Secondary glazing - Low
emissivity" was unmapped and would strict-raise. Cascade code 12 carries
the same daylight/solar bucket as 7/11 (g_L=0.80, g⊥=0.76); the lodged
manufacturer U/g drive §3/§6. With this the double family (codes 1/2/3/
7/13 via their Elmhurst phrasings) and the secondary family (4/11/12) are
fully covered. Coverage test extended.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §3.3: "As Main Wall: Yes" makes an extension inherit the main
dwelling's external wall CONSTRUCTION only — the party wall type is
lodged separately per building part in the Summary §7 block and may
differ. `_extract_extensions` was copying `main_walls.party_wall_type`
into the inherited WallDetails, so every extension reused the main's
party wall U.
On the double_glazing fixture (Summary_001431) the Main lodges party
"CU Cavity masonry unfilled" (SAP10 wall_construction 4 → u_party_wall
0.5) but the 1st Extension lodges "U Unable to determine" (→ 0 → RdSAP
default 0.25). Pre-fix both building parts used 0.5, inflating worksheet
(32) party-wall heat loss by 6.56 W/K (Ext1 26.25 m² × 0.25). After the
fix worksheet (32) is exact: ours 32.573 vs worksheet 32.5725.
Now reads the extension's own "Party Wall Type" from its §7 chunk,
falling back to the main's only when the extension lodges none. Adds a
fixture + test asserting Main=4 / Ext=0 with distinct u_party_wall.
Suite 2413 pass; no cohort regression.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The double_glazing recommendation fixture (Summary_001431) exercises every
RdSAP-21 §11 glazing lodging in one cert; five labels were missing from
`_ELMHURST_GLAZING_LABEL_TO_SAP10` and strict-raised `UnmappedElmhurstLabel`:
"Secondary glazing" -> 7 (Table 6b "secondary glazing", g_L 0.80)
"Secondary glazing - Normal emissivity" -> 11 (RdSAP-21 secondary normal-E, g_L 0.80)
"Triple pre 2002" -> 10 (triple pre-2002, g_L 0.70)
"Triple with unknown install date" -> 6 (generic triple glazed, g_L 0.70)
"Single glazing, known data" -> 15 (single known-data, g_L 0.90)
The glazing code's only cascade effect is the §5 (66)..(67) daylight factor
g_L in `_G_LIGHT_BY_GLAZING_CODE` (single 0.90 / double+secondary 0.80 /
triple 0.70); the lodged manufacturer U-value and solar_transmittance drive
§3 / §6 directly (`_g_perpendicular` prefers the lodged value). Codes are the
semantically-exact RdSAP-21 rows within the correct g_L bucket, kept distinct
for the strict-raise audit trail. Adds a full-coverage test over all 13
distinct labels. Suite 2413 pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>