The heat-network mirror of keep_existing_off_peak_meter: the override's
2313 default applies only when the replaced system's control is
cross-family (stale); an observed community control survives.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Per-axis choice (decided with Khalim): the kit axis concedes to the
evidence (community schemes skew modern; lodged community certs are
overwhelmingly thermostatted, none lodge 2301), the charging axis stays
flat-rate — usage-linked billing is scheme paperwork an override
cannot see.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0048's intended end-state (#1444 Part C): every mapped archetype now
resolves confident companions, so an incomplete set can only mean a new
archetype landed without choosing them — fail loudly at overlay time.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The last real archetype on the companion-gap log; the log test now
simulates a future incomplete archetype (warm-air heat pump, Group 5
control deliberately unmapped).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A system-replacing override whose category or control is not yet mapped
now logs an error naming the archetype and code, so the incomplete
companion set (which otherwise silently inherits the replaced system's
value) is visible for review — log-and-continue, matching flag_fuel_mismatch.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Control 2601 (SAP Table 4e Group 6 room-heater, +0.3 C conservative
default) now overlaid for electric room heaters, matching the gas/oil/
solid siblings, so a replaced storage heater's manual charge control
2401 (+0.7 C) no longer survives and over-warms the modelled dwelling.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Category 10 (SAP Table 4a Room heaters) now overlaid for electric room
heaters (691-701), so a replaced storage heater's category 7 no longer
survives onto the effective cert and mis-bills via the Table 12a resolver.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_category_for` mapped room heaters / heat pumps / heat networks but
returned None for electric-storage-heater codes (401-409), so a storage
system override emitted `sap_main_heating_code=409` +
`main_heating_category=None` while `_control_for` right beside it correctly
set the storage charge control — an asymmetry. Map storage codes to
category 7 so the overlaid cert is internally consistent (code 401-409 <->
category 7), matching the control/fuel/meter companions the overlay drags.
Consistency follow-up to the modelling HHRSH off-peak-pricing fix (#1426):
that PR's Table 12a resolver already prices any storage-coded system
off-peak regardless of category, so this is NOT a live mispricing — it
removes a latent code<->category inconsistency that other category-keyed
logic (responsiveness, pumps/fans) could trip on.
Tests: storage/HHRSH overlay tests now also assert `main_heating_category==7`.
tests/domain/epc (347) + prediction/override/reclassify (118) green; source
pyright-clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Addresses PR #1402 review: the guard only claimed dominant-single, leaving
the symmetric bug open — the LLM can flatten a dominant-double/triple split
onto its minority single (e.g. "96% Double glazing 2002 or later, 4% Single").
A dominant double/triple whose era is explicit ("pre-2002" / "2002 or later")
is just as fully determined as era-free single, so the guard now claims it via
_DOMINANT_MEMBER. Only a genuinely ambiguous era ("unknown age", unstated) still
defers to the LLM — the "96% double -> None" contract now holds solely for the
era-unknown case, not the era-stated one.
Backfill script reuses the same guard, so it now corrects any dominant split;
renamed reclassify_dominant_single_glazing.py -> reclassify_dominant_glazing.py
to match. Tests cover double/triple x pre-2002/2002-or-later and the still-
deferred unknown-age case; 14 green.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The landlord property-type description is a "<dwelling type>: <built form>: <floor>"
split whose leading token IS the dwelling type; the built-form tail is not. The
LLM occasionally over-read the tail and flipped the type — a handful of
"Bungalow: EndTerrace" / "Bungalow: MidTerrace" dwellings were stored as House.
Adds property_type_guard (claims the recognised leading token: House / Bungalow /
Flat / Maisonette / Park home; defers unrecognised phrasings to the LLM) and wires
property_type through a GuardedColumnClassifier, so the built-form tail can never
flip the type and the live path is deterministic.
Applied the scoped backfill to portfolio 796 (Hyde): 3 rows corrected from House
back to Bungalow. No enum migration needed — the targets are original members.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
MainFuelType had no individual wood-logs member — only "biomass (community)" —
so the LLM classifier funnelled "Solid Fuel: Wood Logs" into the community fuel,
inventing a community heat network the dwelling isn't on (and mislabelling the
connection). main_fuel had no deterministic guard at all, so nothing caught it.
Verified against domain/sap10_calculator/docs/specs: RdSAP 10 Specification
Table 32 lists "wood logs" as a solid fuel (code 20, 0.028 kgCO2e/kWh); the
calculator's input scheme (the gov EPC API fuel enum) codes it 6 -> Table 32 20
(sap_efficiencies._API_TO_TABLE32), and water_heating_overlay already pins the
same fuel to 6. So _FUEL_CODES["wood logs"] = 6 is confirmed, not guessed.
Adds MainFuelType.WOOD_LOGS + the _FUEL_CODES entry, a main_fuel_guard mirroring
water_heating_guard (claims the "wood log" token; dual fuel keeps its own member
since it has no "wood log" substring), and wires main_fuel through a
GuardedColumnClassifier so the live path is deterministic.
Applied the scoped backfill to portfolio 796 (Hyde): 21 rows off
"biomass (community)" -> "wood logs". property_overrides (TEXT) only; the
classifier-cache pgEnum member is deferred to the FE Drizzle migration.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A landlord glazing split like "4% Double glazing 2002 or later, 96% Single
Glazing" is a near-uniform *single*-glazing dwelling, but the LLM classifier
latched onto the 4% minority and wrote a "Double glazing…" override — over-
crediting the dwelling.
glazing_mix_guard rescued genuine mixes (no type >= 90%) to MIXED but returned
None for near-uniform splits, trusting the LLM to have applied the dominant type.
It hadn't. Single glazing is era-free, so a dominant-single split is fully
determined: the guard now returns SINGLE for it (dominant double/triple still
carry era ambiguity, so they stay the LLM's job — the existing "96% double" case
still defers).
Adds a portfolio-scoped backfill (reuses the same guard, so it can't drift from
the live path) and applied it to portfolio 796 (Hyde): 115 glazing overrides
corrected from a spurious Double back to Single.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>