The heat-network mirror of keep_existing_off_peak_meter: the override's
2313 default applies only when the replaced system's control is
cross-family (stale); an observed community control survives.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Per-axis choice (decided with Khalim): the kit axis concedes to the
evidence (community schemes skew modern; lodged community certs are
overwhelmingly thermostatted, none lodge 2301), the charging axis stays
flat-rate — usage-linked billing is scheme paperwork an override
cannot see.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0048's intended end-state (#1444 Part C): every mapped archetype now
resolves confident companions, so an incomplete set can only mean a new
archetype landed without choosing them — fail loudly at overlay time.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The last real archetype on the companion-gap log; the log test now
simulates a future incomplete archetype (warm-air heat pump, Group 5
control deliberately unmapped).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A system-replacing override whose category or control is not yet mapped
now logs an error naming the archetype and code, so the incomplete
companion set (which otherwise silently inherits the replaced system's
value) is visible for review — log-and-continue, matching flag_fuel_mismatch.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Control 2601 (SAP Table 4e Group 6 room-heater, +0.3 C conservative
default) now overlaid for electric room heaters, matching the gas/oil/
solid siblings, so a replaced storage heater's manual charge control
2401 (+0.7 C) no longer survives and over-warms the modelled dwelling.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Category 10 (SAP Table 4a Room heaters) now overlaid for electric room
heaters (691-701), so a replaced storage heater's category 7 no longer
survives onto the effective cert and mis-bills via the Table 12a resolver.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_category_for` mapped room heaters / heat pumps / heat networks but
returned None for electric-storage-heater codes (401-409), so a storage
system override emitted `sap_main_heating_code=409` +
`main_heating_category=None` while `_control_for` right beside it correctly
set the storage charge control — an asymmetry. Map storage codes to
category 7 so the overlaid cert is internally consistent (code 401-409 <->
category 7), matching the control/fuel/meter companions the overlay drags.
Consistency follow-up to the modelling HHRSH off-peak-pricing fix (#1426):
that PR's Table 12a resolver already prices any storage-coded system
off-peak regardless of category, so this is NOT a live mispricing — it
removes a latent code<->category inconsistency that other category-keyed
logic (responsiveness, pumps/fans) could trip on.
Tests: storage/HHRSH overlay tests now also assert `main_heating_category==7`.
tests/domain/epc (347) + prediction/override/reclassify (118) green; source
pyright-clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
MainFuelType had no individual wood-logs member — only "biomass (community)" —
so the LLM classifier funnelled "Solid Fuel: Wood Logs" into the community fuel,
inventing a community heat network the dwelling isn't on (and mislabelling the
connection). main_fuel had no deterministic guard at all, so nothing caught it.
Verified against domain/sap10_calculator/docs/specs: RdSAP 10 Specification
Table 32 lists "wood logs" as a solid fuel (code 20, 0.028 kgCO2e/kWh); the
calculator's input scheme (the gov EPC API fuel enum) codes it 6 -> Table 32 20
(sap_efficiencies._API_TO_TABLE32), and water_heating_overlay already pins the
same fuel to 6. So _FUEL_CODES["wood logs"] = 6 is confirmed, not guessed.
Adds MainFuelType.WOOD_LOGS + the _FUEL_CODES entry, a main_fuel_guard mirroring
water_heating_guard (claims the "wood log" token; dual fuel keeps its own member
since it has no "wood log" substring), and wires main_fuel through a
GuardedColumnClassifier so the live path is deterministic.
Applied the scoped backfill to portfolio 796 (Hyde): 21 rows off
"biomass (community)" -> "wood logs". property_overrides (TEXT) only; the
classifier-cache pgEnum member is deferred to the FE Drizzle migration.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Covers the 10 audited "community CHP and boilers" properties (302) alongside the
2,210 "community boilers" (301) — both were mis-bucketed to Gas CPSU.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Generalise the room-heater category-10 + conservative-control drag to cover both
solid and oil families; oil's natural fuel is heating oil (28).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Heat pump drags category 4 + electricity (29). Meter stays single-rate: a heat
pump does not imply an off-peak tariff the way storage/CPSU do (SAP §12 Rule 3
is conditional), so forcing Dual would mis-bill it.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Solid fuel is ambiguous across coal/wood/smokeless/pellets, so the overlay
defaults to house coal (33, the most common) when no main_fuel override is
given; a specific solid-fuel override still wins by last-wins composition.
Updates the ADR-0041 natural-fuel amendment accordingly (every archetype drags
a natural fuel; solid defaults to coal).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A landlord heating override DESCRIBES the dwelling, so its assumed off-peak meter
(Dual/E7) is a coherent default — it must not downgrade a cert that already
lodges a more-off-peak meter (e.g. property 709874's 24-hour all-low tariff). The
overlay opts in via keep_existing_off_peak_meter; _fold_heating then keeps the
cert's meter when both it and the desired meter are off-peak. Heating MEASURES
build HeatingOverlay directly and leave the flag False, so they still re-meter
for real (Elmhurst re-lodges 18-hour -> Dual on a storage install) — the cascade
pins stay green.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
System-built is RdSAP code 6, colliding with the gov-EPC code-6 basement
sentinel that main_wall_is_basement falls back to. The wall overlay now pins
wall_is_basement=False for system-built, mirroring the gov-API mapper's
_clear_basement_flag_when_system_built, so the override no longer adds a phantom
basement (which inflated both wall and ground-floor heat loss).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Electric room heaters (691) get a Dual meter from the overlay (not single-rate):
an all-electric room-heater dwelling realistically bills on Economy 7, and the
§12 dispatch then applies a high/low split rather than a single-rate over-penalty.
Overlay owns its assumed-meter policy via _ASSUMED_DUAL_METER_CODES (the §12
off-peak systems + room heaters), keeping OFF_PEAK_IMPLYING_HEATING_CODES pure.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
'Electric room heaters' archetype -> SAP Table 4a code 691 (panel/convector/
radiant), on a single-rate meter (691 is not off-peak-implying, unlike storage).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>