Commit graph

393 commits

Author SHA1 Message Date
Khalim Conn-Kowlessar
6c6be1a432 Electric underfloor codes resolve their SAP 10.2 Table 12a Grid 1 rows 🟩
421 slab -> Other storage heaters (0.00); 422/423 integrated -> 0.20;
424/425 screed/timber -> 0.90/0.50 — per the Grid 1 row labels that name
the codes (PDF p.184). Closes the None all-low-rate fallback that
over-credited 7-hour-metered underfloor dwellings.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 16:00:40 +00:00
Jun-te Kim
23ebd5e637
Merge pull request #1446 from Hestia-Homes/fix/ashp-size-to-dwelling-heat-loss
Size the ASHP to the dwelling's design heat loss (fix undersized fixed pump scoring below baseline)
2026-07-03 13:32:30 +01:00
Khalim Conn-Kowlessar
039df7ae87 The calculator exposes the dwelling design heat loss for heat-pump sizing 🟩
design_heat_loss_kw = annual-average HLC x 24.2 K (SAP design temperature
difference) / 1000, the quantity Appendix N's PSR divides a heat pump's
rated output by — surfaced so the ASHP recommendation can size the pump.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:17:42 +00:00
Khalim Conn-Kowlessar
cd4ed81185 The calculator exposes the dwelling design heat loss for heat-pump sizing 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:16:43 +00:00
Jun-te Kim
dee72bbdfa fix(rdsap): §5 (12) floor infiltration falls back to floors[].description
_has_suspended_timber_floor_per_spec only read the Main bp's per-part
floor_construction_type lodgement; the gov-API mapper frequently leaves
that None even when the global epc.floors[].description carries an
explicit "Suspended, ..." observation. _main_floor_u_value already fell
back to this joined description for the U-value calc — the infiltration
rule did not, so a genuinely suspended-timber floor silently entered
(12)=0 instead of 0.2 unsealed. Extracted the shared
_effective_floor_description helper and added a tri-state resolver
(explicit lodgement -> description, excluding "not timber" -> Table 19
footnote-1 age-A/B default) so both paths agree.

Cert 100061275133 (Elmhurst-validated build, PR #1439 handoff): engine
77.24 -> 76.33, now an exact match to lodged (76). Corpus gauge 77.7% ->
77.8% within-0.5, MAE 0.637 -> 0.636; floors ratcheted.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 09:12:19 +00:00
Jun-te Kim
8e33a8de53 test(accuracy): ratchet 77.3% -> 77.7% via flat-roof insulation-thickness fix (Elmhurst-validated)
A FLAT roof lodges its insulation thickness in the DEDICATED gov-EPC API
`flat_roof_insulation_thickness` field (e.g. "75mm"), leaving
`roof_insulation_thickness` None (that field is for pitched-loft joists).
`heat_transmission_from_cert` read only the latter, so a measured
flat-roof thickness was ignored and the roof billed at the uninsulated
age-band flat default (age E = 1.5) instead of its Table-16 insulated U.

Fixed by preferring `flat_roof_insulation_thickness` when the part is a
flat roof — the exact mirror of the existing rafter-thickness branch.
An "AB"/"NI" (as-built/unknown) value parses to None and keeps the
age-band default, unchanged; only measured thicknesses move.

PER-CERT ELMHURST VALIDATION (cert 47084930, top-floor flat, flat roof
75 mm): built on the lodged inputs in accredited Elmhurst RdSAP10-Online
(evidence saved: elmhurst_summary.pdf / elmhurst_worksheet.pdf). The
worksheet bills "insulated flat roof" at U 0.5 (floor 0.70 + wall 0.25
also matching the engine). The fix takes the engine roof 96.4 -> 32.1 W/K
(= 64.26 x 0.5, Elmhurst-exact), PE +47 -> +0.2, SAP 69.51 -> 74.34 =
lodged 74.

Gauge: within 77.3% -> 77.7%, SAP MAE 0.648 -> 0.641, CO2 0.074 -> 0.072,
PE 3.1 -> 2.97. Unit-pinned in test_heat_transmission
(flat_roof_insulation_thickness -> U 0.5); RealCertExpectation 47084930
= 74 (Elmhurst-validated). Also adds the build script build_47084930.py.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 23:27:57 +00:00
Jun-te Kim
11a637c6bd test(accuracy): ratchet 77.0% -> 77.3% via unsized-cylinder storage-loss fix
A hot-water cylinder lodging gov-API `cylinder_size=0` ("size not
determined", with has_hot_water_cylinder=true) resolved to a None volume
in `_cylinder_storage_loss_override` (which reads `_cylinder_volume_l_
from_code`, returning None for code 0). The subsequent `if volume_l is
None: return None` then DROPPED the cylinder's Table-2 storage loss
entirely — under-costing the DHW and over-rating the dwelling. Meanwhile
the Table-13 high-rate-fraction path already used `_hot_water_cylinder_
volume_l` (which defaults size 0 to 110 L), so the two DHW paths
disagreed on the same cylinder.

RdSAP 10 §10.5 Table 28 ("if the actual size is not determined, the size
is taken as according to Table 28") makes an unsized present cylinder the
110 L "Normal" baseline, which STILL incurs the storage loss. Fixed by
defaulting the storage-loss volume to 110 L for the explicit size-0 case.

Gated on the EXPLICIT 0 (not None): a full-SAP cert whose RdSAP
cylinder_size is simply unlodged (None, e.g. pinned 10091568921) keeps
its own cylinder handling rather than a forced 110 L RdSAP default.

7 corpus certs lodge cylinder_size=0 + has_cylinder=true. Gauge: within
77.0% -> 77.3%, SAP MAE ~flat (0.648), CO2 0.074 -> 0.073, PE 3.2 -> 3.05
(the previously-dropped storage loss now correctly counted in the demand
cascade). Unit-pinned in test_cert_to_inputs (storage loss non-None for
size 0); RealCertExpectation 200004017091 = 71.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 23:02:27 +00:00
Jun-te Kim
cb089a630c test(accuracy): ratchet SAP MAE 0.668 -> 0.658 via instantaneous-electric-DHW off-peak fix
An instantaneous point-of-use electric water heater (WHC 907/909, no
cylinder) on an off-peak tariff was billed 100% at the off-peak LOW rate
by the generic electric-off-peak else-branch. But SAP 10.2 §12 (PDF line
2680) computes the off-peak on-peak HW proportion via Table 13, "dependent
on the total floor area and the CYLINDER size" — it presumes a stored-water
cylinder charged overnight. An instantaneous heater has NO cylinder, heats
on demand, and cannot shift to the off-peak window, so 100% of its
consumption bills at the HIGH rate (Table 12a WH high-rate fraction 1.0).

Both the SAP-cost rate (`_hot_water_fuel_cost_gbp_per_kwh`) and the
ADR-0014 / CO2-PE fraction (`_hot_water_high_rate_fraction`) fixed
consistently (low-rate scalar -> 7-hour high rate; fraction 0.0 -> 1.0).

Localised by deep-diving corpus cert 74061136 (HHR-storage mid-floor flat,
WHC 909): PE matched lodged (+1.6, roof+floor zero-loss) while SAP over-rated
+7.72 — the cost-only signature. Its DHW was ours £59 vs lodged £344 (5.8x);
the tariff was the whole gap. Fix: +7.72 -> -1.25 (residual is separate small
fabric). 7 corpus certs carry electric-instantaneous DHW on off-peak; the 3
outside 0.5 all move sharply inward (MAE the win, not within-0.5 crossings).

RdSAP 10 §12 tariff routing confirmed spec-correct (Unknown meter + storage
409 -> off-peak 7-hour, Rule 2) — the bug was the DHW rate, not the tariff.
Unit-pinned in test_cert_to_inputs; RealCertExpectation 74061136 = 72.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 20:04:58 +00:00
Jun-te Kim
06a2c413f5 test(accuracy): ratchet 75.5% -> 77.0% via secondary-fuel collision fix on cost path
The gov-API `secondary_fuel_type` enums 5 (anthracite) / 9 (dual fuel) /
33 (coal) collide in VALUE with same-valued RdSAP-10 Table-32 codes for
OTHER fuels (5=bulk LPG, 9=LPG SC11F, 33=elec 10h-low). The main-fuel
boundary and the CO2/display `_secondary_fuel_cost_gbp_per_kwh` already
canonicalise these via `canonical_fuel_code`, but the SAP-DRIVING
`_fuel_cost` cascade had a SEPARATE inline secondary rate that passed the
raw enum straight to the price lookup — so the two paths diverged and the
cost path silently mis-priced.

Anthracite (enum 5) was billed at the bulk-LPG code-5 rate 12.19 p/kWh
instead of 3.64 — a 3x over-cost on the secondary that under-rated every
solid-fuel-secondary dwelling. Worst: corpus cert 100050355518 (semi,
2 extensions, anthracite room-heater secondary) lodged 36 / engine 20.8
-> 35.5. Its CO2/PE already matched lodged (the demand cascade was right)
— a pure cost-side gap, which is what localised it.

Fix: canonicalise `secondary_fuel` before the Table-32 lookup in
`_fuel_cost`, mirroring the main-fuel boundary. 55 corpus certs carry a
colliding secondary.

Gauge: within-0.5 75.5% -> 77.0%, SAP MAE 0.708 -> 0.668 (floors
ratcheted). The prior enum-9 test only guarded the display helper; new
test_fuel_cost_secondary_colliding_fuel_priced_at_canonical_rate pins the
_fuel_cost cost path directly. RealCertExpectation pinned for
100050355518 (36 = lodged).

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 19:43:31 +00:00
Jun-te Kim
ecefd439fd Cylinder with unknown insulation defaults per RdSAP Table 29 age band 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 16:11:10 +00:00
Jun-te Kim
233f085fb3 Elmhurst 'No Insulation' cylinder (0 mm lodged) takes the uninsulated storage loss 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 16:08:46 +00:00
Jun-te Kim
e813cc0ef2 Uninsulated cylinder (type 0) takes the SAP Table 2 jacket t=0 storage loss 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-02 16:06:33 +00:00
Jun-te Kim
f5fbeb8e7e Fix HHRSH storage heaters priced at peak rate (engine 48 vs Elmhurst 71)
The high-heat-retention storage-heater (HHRSH) recommendation was computed
as LOWERING SAP and wrongly rejected by the Optimiser, leaving electric-
room-heater flats/maisonettes stuck at band E with no sensible plan.

Root cause: `_HHR_STORAGE_OVERLAY` sets `sap_main_heating_code=409` (HHR
storage) + `meter_type="Dual"` but left `main_heating_category` at the
pre-existing value (10 = electric room heaters). The SAP 10.2 Table 12a
space-heating high-rate-fraction resolver classifies by category, so it
misread the off-peak storage heating as direct-acting electric (1.00
high-rate) and priced 100% at the 7-hour peak rate (15.29p) instead of the
storage off-peak split (0.00, ~5.5p).

Verified against accredited Elmhurst RdSAP-10 on UPRN 100020942571
(8 Booth Close, SE28 8BW): engine HHRSH SAP 48 (peak-priced, cost £1087)
vs Elmhurst 71 (cost ~£611); with the fix the engine gives 73 / £576.

Two-part fix (defence in depth, so no future overlay/mapper can
reintroduce it):
- `_HHR_STORAGE_OVERLAY` now sets `main_heating_category=7`, keeping the
  overlaid EPC internally consistent.
- `_table_12a_system_for_main` now classifies electric storage heaters by
  their Table 4a SAP code (401-409) as well as `category==7`, checked
  before the room-heater branch, so a specific storage code is
  authoritative over a stale/inconsistent category.

Tests: new regression `test_storage_heater_classified_by_sap_code_over_stale_category`;
updated the HHRSH overlay pin. Full accuracy corpus still passes (no regressions).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-02 11:24:03 +00:00
Daniel Roth
afe6638b36 Gate community-heated dwellings from HHRSH recommendation 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-07-01 14:13:57 +00:00
Khalim Conn-Kowlessar
dbaf3c49e2 fix(hp): floor heat-pump water-heating efficiency at 100% (App N3.7) 🟩
_heat_pump_apm_efficiencies applied the Table N8 in-use factor to the PCDB
water-heating efficiency but omitted the spec's "subject to a minimum
efficiency of 100%" clause (SAP 10.2 Appendix N3.7, PDF p.109). An oversized
heat pump whose PSR-extended water,3 x the 0.60 in-use factor fell below
100% therefore billed water heating at that sub-100% efficiency, over-
counting hot-water fuel.

Apply max(in_use x eta_water, 100%). Accredited Elmhurst worksheet for cert
100110101713 (golden fixture case 56, PCDB 100061): water (216) = 100.0000,
which we now match (was 77.13%). Combined with the space-heating PSR-
extension fix the cert lands 72.51 vs lodged 73 (|err| 18.32 -> 0.49).

Data-driven: only the single oversized-PSR cert moves (in-range heat pumps
keep their > 100% water COP, e.g. case 54 112.5%, case 55 179.6%). Corpus
(RdSAP-21.0.1 n=1000) MAE 0.726 -> 0.721, within-0.5 74.1% -> 74.2%.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-29 15:38:31 +00:00
Khalim Conn-Kowlessar
51d8f65aac fix(pcdb): extend heat-pump efficiency toward 100% beyond table PSR range 🟩
interpolate_heat_pump_efficiency_at_psr clamped to the smallest/largest PSR
row when the dwelling's plant size ratio fell outside the record's range.
That is the SAP 10.2 Appendix N rule for *combined heat-pump-and-boiler*
packages, not for a plain air/ground/water source heat pump.

Per Appendix N2 (PDF p.101, footnotes 44/45) a source heat pump whose PSR
exceeds the record's largest value takes a reciprocal-linear interpolation
between the largest-PSR efficiency and 100% at twice that PSR (100% beyond),
and 100% when the PSR is below the record's smallest value. Both the space-
and water-heating PSR-dependent efficiencies extend this way.

Effect: an oversized heat pump in a small dwelling is no longer credited the
full top-of-table COP. Accredited Elmhurst worksheet for cert 100110101713
(golden fixture case 56, PCDB 100061, PSR 3.107 over largest 2.0): (206)
334.4% -> 139.66% = Elmhurst exact. Corpus (RdSAP-21.0.1, n=1000) MAE
0.7397 -> 0.7258, within-0.5 0.7410 held; only two certs move (both
oversized-PSR heat pumps), 100110101713 +18.32 -> -4.97.

Exhaust-air and combined heat-pump-and-boiler packages have different
boundary rules (straight-to-100% / clamp-to-edge) but are not distinguished
by the current PCDB parse; the air/ground/water rule is applied uniformly,
a documented limitation noted in the function docstring.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-29 15:13:16 +00:00
Khalim Conn-Kowlessar
8606cab5f0 fix(pv): credit PV only when connected to the dwelling's meter 🟩
Gate PV generation/credit in cert_to_inputs on gov-API pv_connection:
credit only when ==2 ('connected'); ==1 ('present but not connected to the
dwelling's meter') contributes zero to the dwelling's cost/CO2/PE per
RdSAP 10 §11.1 / SAP 10.2 Appendix M. Non-int (None / site-notes str) keeps
the credit-if-array behaviour, so the Elmhurst/Summary + synthetic paths are
unchanged (no regression).

Corpus: all 5 pv_connection=1 PV certs move inside ±0.5 (e.g. 100051118081
+6.5→+0.5); MAE 0.760→0.740, within-0.5 73.8→74.3%, no regression
(pv_connection=2 certs keep their credit).

Also corrects a now-load-bearing latent bug: the solar-recommendation
overlay tagged recommended arrays pv_connection=1 ('not connected') — which
the new gate would zero. A new install connects to the dwelling's meter, so
it must be 2; pinned by the overlay test.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-29 13:40:51 +00:00
Khalim Conn-Kowlessar
0f79de7a35 fix(exposure): honour determined roof_insulation_location for flats 🟩
A gov-API flat can lodge dwelling_type="Mid-floor flat" while carrying its
own exposed roof — a top-floor flat mislabelled mid-floor. _dwelling_exposure
keyed roof exposure on the dwelling_type label alone, dropping the roof
heat-loss term: space-heating demand under-read ~32%, SAP over-read +7.

Fix: when the main building part lodges a *determined* roof_insulation_location
(an RdSAP integer code, not the "ND" Not-Defined party-ceiling sentinel),
expose the roof regardless of a contradictory label. Structured field, not a
description string and not roof_construction (which the gov-API lodges
building-wide on every unit, so it is not a per-unit signal).

On the RdSAP-21.0.1 corpus roof_insulation_location separates the classes with
zero disagreement: all 190 party-ceiling flats lodge "ND"; the 4 mid/ground
flats this exposes all move toward lodged, 0 away. within-0.5 73.3% -> 73.6%,
MAE 0.774 -> 0.761 (ratchets tightened). Verified end-to-end on the same
block: 715363 (location 6, RHI 2694) 81 -> 74 = lodged; genuine mid-floor
sibling 715395 (location ND, RHI 1024) stays party at 83 = lodged.

The override is additive (only ever exposes a label-dropped roof) and reads
the main part, so multi-part flats with a party main ceiling stay party.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-26 21:34:33 +00:00
Daniel Roth
60b4cae498 _secondary_heating_fraction_for_category returns 0.10 for category 11 (electric ceiling heating) 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-25 15:59:47 +00:00
Khalim Conn-Kowlessar
81d5429b60 Source every end use's off-peak high-rate fraction from the cert 🟩
Surface the hot-water (Table 13 / HP-DHW), secondary (direct-acting),
main-2 and ALL_OTHER_USES High-Rate Fractions on CalculatorInputs from
the same Table 12a helpers the SAP cost path uses, so Bill Derivation's
day/night split matches the rating's exactly.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 17:57:23 +00:00
Khalim Conn-Kowlessar
b58e27f46e Source the off-peak meter flag and main-heating fraction from the cert 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 17:52:39 +00:00
Khalim Conn-Kowlessar
3f5cd550cb Thread the off-peak meter flag and high-rate fractions onto SapResult 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 17:45:29 +00:00
Khalim Conn-Kowlessar
05977ee3ce Route an off-peak meter's electric end uses to the day/night carrier 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 17:38:37 +00:00
Jun-te Kim
fc7cfc70e8
Merge pull request #1295 from Hestia-Homes/fix/fuel-code-39-electricity
Map fuel code 39 (electricity, any tariff) to standard electricity
2026-06-24 12:37:25 +01:00
Jun-te Kim
2498192b72 docs(fuel): TODO to price code-39 electricity by actual tariff (Khalim)
Note that code 39 "any tariff" currently collapses to the standard electricity
rate; future work should resolve it to the dwelling's actual tariff (off-peak vs
standard) so off-peak electric heating prices correctly. Comment-only.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:35:31 +00:00
Jun-te Kim
782c686969 Map fuel code 39 (electricity, any tariff) to standard electricity
modelling_e2e properties with main fuel 39 failed at the price boundary
(UnpricedFuelCode since #44fff767; previously mis-rated as non-electric →
the ~14-SAP over-rating flagged in earlier review).

Code 39 is SAP Table 12 "electricity, any tariff" (epc_codes.csv main_fuel 39 =
"electricity, unspecified tariff"; spec footnote (j): defines an electric system,
cost/CO2/PE = standard electricity). It was absent from API_FUEL_TO_TABLE_32, so
to_table_32_code(39) was None → is_electric_fuel_code(39) False and pricing
raised.

Fix: map API_FUEL_TO_TABLE_32[39] = 30 (standard electricity) — the canonical
place Khalim's fuel work added codes. One line makes classification, pricing,
CO2/PE and the billing carrier all agree (39 → 30 → ELECTRICITY).

Tests: to_table_32_code(39)==30, is_electric_fuel_code(39) True, price == standard
electricity, and the billing carrier resolves to ELECTRICITY. 0 corpus impact
(no lodged corpus cert uses 39); accuracy + mapper-corpus gates green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:20:32 +00:00
Khalim Conn-Kowlessar
f6ec96fbcd Merge remote-tracking branch 'origin/main' into feature/e2e-runs
# Conflicts:
#	domain/sap10_calculator/tables/table_12a.py
2026-06-24 11:07:42 +00:00
KhalimCK
f7f74ea72b
Merge pull request #1288 from Hestia-Homes/feature/per-cert-mapper-validation
Feature/per cert mapper validation
2026-06-24 12:04:00 +01:00
Khalim Conn-Kowlessar
db3bf00602 fix(synthesis): Coherent Heating System — synthesisers own the whole boundary
A dwelling's heating is one conceptual system, but its fields are scattered
across EpcPropertyData (a gov-API schema mirror): the cluster on sap_heating, the
electricity tariff on sap_energy_source.meter_type, hot-water flags loose at top
level. Three places synthesise a heating system — Measure Options, Landlord
Overrides, EPC Prediction's donor — and each hand-copied a different ad-hoc
subset. The override and donor both dropped meter_type, so an electric-storage
system landed on the template's single-rate meter and billed overnight heat at
the peak rate: property 713406 scored SAP 13 (G) vs ~50 (E), inflating the HHRSH
measure to +45.8 and overshooting the plan to band A.

Establish a single Coherent Heating System boundary (CONTEXT.md) that every
synthesiser must cover, with a source-appropriate fill policy (ADR-0035):

- Override overlay *completes* the partial system the landlord named. Companion
  fields are now DERIVED from the SAP code, not hand-attached per archetype: the
  off-peak meter from the calculator's single off-peak classification (new
  OFF_PEAK_IMPLYING_HEATING_CODES = SAP §12 Rules 1-2), and an unobserved storage
  charge control defaults to the conservative manual control (Table 4e 2401). So
  adding a heating archetype is just adding its code — companions can't be
  forgotten. A contract test guards it (every off-peak code drags a Dual meter).
- Prediction's heating donor now *carries* the donor's meter_type alongside its
  sap_heating cluster — the donor is already coherent.

Coherence is a synthesis-time obligation only; the calculator still scores a real
lodged cert exactly as lodged.

Verified on 713406: baseline 13 -> 47.8 (E), matching its recorded rating; the
phantom HHRSH recommendation is gone and the plan no longer overshoots to A.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:46:11 +00:00
Khalim Conn-Kowlessar
39ae2cf0c2 fix(water-heating): split whc-903 immersion HW CO2/PE on off-peak tariffs
SAP 10.2 Table 12d/12e: electric water heating on a 7-/10-hour tariff bills
CO2/PE at the high-rate code (32/34) and low-rate code (31/33), kWh-weighted
by the Table 13 high-rate fraction. The cost path already applied this split;
the CO2/PE factors did not — they used the flat annual Table 12 figure
(0.136 CO2 / 1.501 PE) for ALL dual-rate electric HW.

That flat-annual behaviour (slice S0380.163) was validated only against
HW-from-main "low-rate cost" certs (100% low, no high-rate split). It is NOT
how Elmhurst bills a whc-903 ELECTRIC IMMERSION: the hand-built case-50
worksheet (000565 + dual immersion, 7-hour) splits HW CO2/PE into "high rate
cost" (CO2 0.1475 / PE 1.5514) + "low rate cost" (CO2 0.1238 / PE 1.4429)
weighted by the Table 13 fraction 0.1009. So flat-0.136 for immersion HW was
a spec gap on our side, not an Elmhurst divergence.

Fix: `_electric_immersion_hw_high_rate_fraction` threads the Table 13 fraction
(scoped to whc-903, 7-/10-hour, cylinder data present) into the HW CO2 + PE
factor helpers, which then blend the Table 12d/12e high/low codes. The flat
rule is unchanged for HW-from-main and 18-/24-hour (no Table 12d split), so
the S0380.163 41-variant cases and the existing pin are untouched.

Case 50: rating CO2 2413.48 -> 2397.1237 = Elmhurst EXACT; demand CO2 2007.1384
EXACT; demand PE +111 -> +32.5 residual (within corpus PE noise). Corpus
unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4 (62 whc-903 off-peak certs;
aggregate gauges hold). SAP unaffected (cost-based).

Pin: test_whc903_immersion_hw_co2_pe_factors_split_high_low_on_off_peak; doc
updated in SAP_CALCULATOR.md §8.1.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:05:21 +00:00
Khalim Conn-Kowlessar
cd5113abf2 fix(tariff): include MVHR fan electricity in the off-peak Grid 2 fan split
SAP 10.2 Table 12a Grid 2 (PDF p.191) bills "Fans for mechanical ventilation
systems" at 0.71 (7-hour) / 0.58 (10-hour), distinct from "All other uses"
(0.90 / 0.80) which covers circulation pumps, flue fans and the solar HW pump.

The cost-split mech-vent kWh (`mev_kwh_for_cost_split`) only summed the
decentralised-MEV (230b) fans, not the (230a) MVHR fan electricity — even
though the total pumps/fans bucket adds both. So an MVHR dwelling on an
off-peak tariff billed its fan electricity at the 0.90/0.80 "all other uses"
rate instead of 0.71/0.58. The comment already said "MEV/MVHR-fan portion";
only the MEV term was wired when MVHR landed. Fixed to mirror both
mechanical-ventilation fan terms summed into the total.

Worksheet-proven on simulated case 50 (000565 semi + MVHR Vent Axia + dual
electric immersion, Unknown meter -> 7-hour via the §12 dual-immersion
trigger): the fan bucket (315.64 kWh, 100% MVHR per worksheet line 230a) was
billing at 14.311 p/kWh (0.90) vs Elmhurst's 12.451 p/kWh (0.71) — +£5.87/yr,
-0.23 SAP. After the fix our existing-dwelling rating reconciles to Elmhurst
EXACTLY: SAP value 38.8426 (=Elmhurst 38.8426 -> 39), total cost £1317.0116
(=Elmhurst £1317.0116 to the penny).

Same `mev_kwh_for_cost_split` feeds the CO2 + PE cascades, so all three split
consistently. 0 corpus impact (all 3 corpus MVHR certs are standard tariff);
gauge unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4.

Pin: test_mvhr_fan_electricity_bills_at_grid2_fan_fraction_on_off_peak.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 22:16:58 +00:00
Khalim Conn-Kowlessar
eea5d3a5a8 fix(tariff): map electric boilers 191/193-196 to their Table 12a Grid 1 rows
SAP 10.2 Table 4a electric boilers (PDF p.170) split across three distinct
Table 12a Grid 1 SH rows (PDF p.191), not one "direct-acting" family as the
stale TODO in `_table_12a_system_for_main` implied:

  - 191 Direct-acting electric boiler   -> "Direct-acting electric boiler (a)"
    row: 7-hour 0.90, 10-hour 0.50 (NOT the 1.00/0.50 "Other direct-acting
    electric heating" room-heater row).
  - 193/194/195/196 Electric dry core / water storage boiler -> "Electric dry
    core or water storage boiler" row: 7-hour 0.00 (charged wholly off-peak =
    100% low rate, identical to the None fallback).
  - 192 Electric CPSU -> Appendix F; left falling through to None (off-peak
    low) until the Appendix-F high-rate cascade is implemented.

The enum + fractions already existed in table_12a.py; only the code->enum
mapping was missing. Resolves the TODO and pins the spec-correct 0.00 for the
storage boilers so 195 can't be mis-"fixed" up to a direct-acting fraction.

Forward guard, 0 corpus impact: storage boilers already billed 100% low via
the None fallback, and all corpus 191 certs are on standard tariff (Table 12a
off-peak split never fires). Corpus gauge unchanged 73.3% / MAE 0.774.

Pin: test_electric_boilers_191_195_map_to_distinct_table_12a_grid1_rows.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 21:48:59 +00:00
Khalim Conn-Kowlessar
9694650abe fix(water-heating): derive combi keep-hot from the PCDB record, default no-keep-hot
SAP 10.2 Table 3a (PDF p.160) additional combi loss (61)m. Two coupled
defects, both surfaced by simulated case 49 (000565 + gas combi, U985
"Combi keep hot type = None") sitting at SAP 71.43 vs the worksheet's 72:

1. The cascade defaulted EVERY non-PCDB combi to the flat keep-hot
   time-clock row (600 × n/365). A combi WITHOUT a keep-hot facility uses
   row 1 (600 × fu × n/365, fu = V_d/100 when daily HW < 100 L/day) —
   over-counting (61)m for the no-keep-hot cohort. `water_heating_from_
   cert` now defaults to the "without keep-hot" row.

2. `pcdb_combi_loss_override` returned None for keep_hot_facility=1/
   timer=1, leaning on the OLD flat-600 default. So flipping the default
   silently turned 190 corpus PCDB keep-hot-time-clock combis into
   no-keep-hot. Fixed to return the flat keep-hot row EXPLICITLY.

Key insight (the Summary is the input echo; the U985 keep-hot line is a
computed OUTPUT, so it must be derivable): keep-hot rides on the PCDB
boiler record (Table 105 keep_hot_facility/timer), resolved by
`pcdb_combi_loss_override`. A generic SAP-code combi with no PCDB record
(case 49, PCDF ref 0) has no keep-hot by construction → row 1. So the
default is not a guess — it is the spec-correct value for non-PCDB combis.

Worksheet-proven: case 49 → cost £726.696, SAP 72 — matching the
accredited worksheet to the digit (continuous 71.6945 = the worksheet's
own 71.6945). 000516 (keep-hot None) also exact (£860.716, SAP 63);
000490 (PCDB 10328, keep_hot_facility=1/timer=1) keeps its flat-600 via
the PCDB path. Masked until now because every prior combi-loss worksheet
fixture was keep-hot (000490/000474/000480 time-clock) or had V_d >= 100
every month (001431, rows coincide); case 49 is the first no-keep-hot one.

Corpus within-0.5 72.7% -> 73.3%, MAE 0.781 -> 0.774, PE 3.5 -> 3.4;
ratcheted _MAX_SAP_MAE 0.785 -> 0.775, _MAX_PE_PER_M2_MAE 3.6 -> 3.5.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 21:22:02 +00:00
Khalim Conn-Kowlessar
b7455aabe5 fix(ventilation): MVHR takes lodged 0 intermittent fans, not the Table 5 default
Extends the dMEV intermittent-fan fix (4db05e84) to MVHR. A balanced
whole-house MVHR system IS the dwelling's ventilation, so the lodged (7a)
intermittent-extract-fan count is explicit — a lodged 0 means 0, not the
RdSAP 10 Table 5 age-band "unknown" default. The cascade was substituting
the default (here 20 m³/h) into worksheet line (8) openings, inflating
(16/18) infiltration → (21) → (22b) → (25) effective ach → (38)
ventilation heat loss → the space-heating demand.

Worksheet-proven on simulated case 49 (000565 + Vent Axia 500140 MVHR,
lodged (7a)=0): our (8) openings 0.0723 -> 0.0000, (18) 0.7223 -> 0.6500,
(25)m Jan 0.9423 -> 0.8571, all now matching Elmhurst exactly; space-
heating demand 7857 -> 7528 kWh (worksheet 7546). SAP 70.90 -> 71.43
continuous. (The residual to the worksheet's 72 is its own continuous SAP
71.69 rounding up, driven by a separate gas-combi water-heating-loss gap,
not ventilation.)

Scoped to EXTRACT_OR_PIV_OUTSIDE + MVHR only — MV-without-HR
(mechanical_ventilation=1) stays on the default-substitution path
(forcing its lodged 0 regressed 47 Howsman / 18 Jutland and is not
worksheet-validated). Corpus within-0.5 holds 72.7%, MAE 0.782 -> 0.781.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 20:15:32 +00:00
Khalim Conn-Kowlessar
7b30b464e5 feat(ventilation): credit MVHR (24a) heat recovery via PCDB Table 323 + 329
MVHR (24a) heat-recovery support, part 2: the mapper + cascade wiring.

Both source paths now resolve balanced whole-house MV with heat recovery
to the MVHR kind:
- gov-API: `_API_MECHANICAL_VENTILATION_TO_KIND` 4 → "MVHR" (was None /
  treated as natural — under-stated ventilation heat loss, over-rating).
- Elmhurst Summary: `_ELMHURST_MV_TYPE_TO_KIND` "Mechanical ventilation
  with heat recovery (MVHR)" → "MVHR" (was UnmappedElmhurstLabel, which
  blocked the whole Summary for MVHR dwellings).

cert_to_inputs resolves the in-use heat-recovery efficiency + SFP for an
MVHR cert (`_mvhr_system_values`): pick the PCDB Table 323 data point by
the lodged wet-room count (SAP 10.2 §2.6.4), multiply the raw efficiency
by the Table 329 ducts-inside-envelope in-use factor (0.90) and the raw
SFP by the per-duct-type factor (rigid 1.4), and feed:
- the §2.6.6 eq (2) effective-air-change credit (23c) → (24a)/(25)m;
- the (230a) fan electricity (in-use SFP × 1.22 × V), costed but NOT
  added to the Table 5a gains (its effect is in the efficiency).
An MVHR lodged with no PCDF index falls back to the SAP 10.2 Table 4g
default (raw efficiency 66% × 0.70, raw SFP 2.0 × 2.5).

Worksheet-proven on simulated case 49 (000565 semi + Vent Axia Sentinel
Kinetic B 500140 + gas combi → Elmhurst Current SAP 72): every MVHR line
matches Elmhurst exactly — (33) fabric heat loss 100.5923, (23c) in-use
efficiency 81.9% = 91 × 0.90, (25)m Jan 0.8571, (230a) fan electricity
415.9325, (231) total pumps/fans 501.9325. The residual SAP 71 vs 72 is
the known 000565-family space-heating-demand artifact (same -1/-2 seen on
cases 47/48), not the MVHR logic.

Corpus: within-0.5 72.6% -> 72.7%, MAE 0.788 -> 0.782, PE 3.6 -> 3.5.
The 3 gov-API MVHR certs: Flat 1 +6 -> 0 (Table 4g default path) and
12a Princes Gate +3 -> +1 (heat-recovery credit); Apartment 707 -4 -> -6
is a separate baseline under-rate (it under-rated as natural too — the
MVHR credit correctly adds ventilation loss per Elmhurst's method).
Ratcheted _MAX_SAP_MAE 0.79 -> 0.785, _MAX_PE_PER_M2_MAE 3.7 -> 3.6.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:45:37 +00:00
Khalim Conn-Kowlessar
34cbd7d66c feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF
MVHR (24a) heat-recovery support, part 1: the PCDB data layer.

PCDB Table 323 (PCDF Spec Rev 6b §A.18, Format 426; pcdb10.dat carries
Format 431, header `$323,431,...`) holds the per-wet-room SFP + heat-
exchanger efficiency for centralised MEV / MVHR units. Added
`MvhrRecord` / `MvhrDataPoint`, `parse_centralised_mv_row` /
`parse_table_323`, the ETL step, the committed jsonl, and the
`mvhr_record(pcdb_id)` runtime lookup (mirrors Table 322).

SAP 10.2 §2.6.4/§2.6.6: "MVHR ... SFP is a single value depending on the
number of wet rooms" — each test group's leading field is the wet-room
count; callers select the group matching the dwelling lodgement.
Worksheet-proven on simulated case 49 (000565, 2 wet rooms, Vent Axia
Sentinel Kinetic B 500140 → flow 21.0, SFP 0.88, efficiency 91%).

Also decoded the MVHR heat-recovery efficiency in-use factor from Table
329 (Format 432): system_type 3 ducts-inside-envelope = 0.90 (case-49
(23c) = 91 × 0.90 = 81.9%), cross-checked against system_type 10 = 0.70
(= SAP 10.2 Table 4g default heat-recovery in-use factor). "Table 4h is
no longer used – data now stored in the PCDB" (SAP 10.2 p.176).

The outside-envelope efficiency columns + with-scheme SFP blocks are
preserved verbatim in `raw` (no fixture exercises them yet).

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:29:17 +00:00
Khalim Conn-Kowlessar
4db05e843c fix(ventilation): dMEV takes lodged 0 intermittent fans, not the Table 5 default (SAP 10.2 §2)
Chasing the space-heating demand gap on "simulated case 48" (main 691 + Unknown
meter + 903 dual immersion): our SAP 55 vs Elmhurst 57. Every §10a cost line
already matched to the penny; the residual was demand — our space-heating
energy 3849.8 kWh vs Elmhurst 3513.8 (+9.6%). Traced through the worksheet: our
ventilation heat loss (38) ran ~35.5 W/K vs Elmhurst 27.76 — we were adding 20
m3/h of intermittent extract fans (the Table 5 age-band default) on a dwelling
with a decentralised mechanical extract (dMEV) system that lodges 0 fans.

SAP 10.2 §2 (PDF p.13): a whole-house mechanical EXTRACT system provides
extraction via the (23a) 0.5 system air-change rate; the lodged intermittent
extract-fan count (7a) is then explicit — a lodged 0 means 0 (the dMEV is the
ventilation), NOT "unknown". The Table 5 default is an unknown-fallback for
NATURALLY ventilated dwellings only, so it must not be substituted here.

Fix: for EXTRACT_OR_PIV_OUTSIDE, take vc.intermittent_fans as-is (no age-band
default). Worksheet-proven on two dMEV builds of cert 000565: "case 48" lodges
(7a)=0 -> our SAP 55 -> 57 EXACT; the original 000565 fixture lodges (7a)=2 and
keeps 2 (its e2e pins are unchanged). An earlier draft that forced fans=0 broke
000565 (which legitimately has 2) — corrected to "lodged as-is".

within-0.5 72.5% -> 72.6%, MAE 0.789 -> 0.788; CO2/PE unchanged. The fix also
reduces a systematic under-rating bias in the 21-cert dMEV cohort (median dSAP
-0.22 -> -0.08). Scoped to EXTRACT_OR_PIV_OUTSIDE; balanced MVHR/MV kinds left
untouched pending their own worksheet. SAP-schema regression
test_18_0_0 pin 80 -> 81 (closer to its lodged 84, same cause). Spec-pinned in
test_cert_to_inputs (dMEV-lodged-0 vs natural-default). pyright not installed
in this container -- strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 11:33:07 +00:00
Khalim Conn-Kowlessar
fd0530159f feat(tariff): complete §12 Unknown-meter clause — GSHP/WSHP main triggers off-peak (RdSAP 10 PDF p.62)
Closes the follow-up from 22fe4f41. RdSAP 10 §12's third Unknown-meter
exception bullet — "main heating is ground source or water source heat pump" —
was unimplemented. Add `_GROUND_OR_WATER_SOURCE_HEAT_PUMP_CODES` (Table 4a,
SAP 10.2 PDF p.176-177: ground 211/215/221/225 + warm-air 521/525; water
213/216/223/226 + warm-air 523/526) to the Unknown-meter off-peak triggers;
once dual, Rules 1-4 (Rule 3) resolve it to 10-hour.

AIR-source heat pumps (214/217/224/227, 524/527) are deliberately EXCLUDED —
the spec names only ground/water source. Verified the only Unknown-meter heat
pumps in the corpus are "3/10 Bedford House" (main 214 = AIR source), which
correctly KEEP STANDARD. 0 corpus certs carry a GSHP/WSHP on an Unknown meter,
so this is a spec-completeness forward guard (gauge unchanged 72.5% / 0.789),
same family as the Scotland-J wall / rafters-M roof 0-impact spec fixes.
Coverage gap noted in-code: a database-index heat pump without a 211/213-style
SAP code can't have its source type read from the code alone (rare).

Spec-pinned (test_unknown_meter_ground_or_water_source_heat_pump_triggers_off_
peak). Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
suite 2989 passed (2 known pre-existing fails). pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 10:09:59 +00:00
Khalim Conn-Kowlessar
22fe4f41b8 fix(tariff): Unknown meter + dual electric immersion → off-peak per §12 (RdSAP 10 PDF p.62)
Supersedes the previous "verified non-fix" doc (3548f1f3): the spec DOES make
this a fix — Khalim was right that the Unknown-meter branch is driven by the
heating/water system, not a blanket STANDARD.

RdSAP 10 §12 (PDF p.62): "If the electricity meter is unknown, treat as single
meter EXCEPT where main heating OR WATER HEATING are intended to run off an
off-peak tariff (per systems listed in the text box above) ... If that results
in a dual meter, assign tariff per rules 1 to 4." The text-box off-peak systems
include DUAL ELECTRIC IMMERSION. Our `rdsap_tariff_for_cert` only triggered the
Unknown→off-peak exception on a storage/CPSU MAIN — it ignored the
dual-electric-immersion WATER-heating trigger, so an Unknown-meter dwelling
with a non-storage main (e.g. room heaters) + dual immersion was billed
STANDARD (13.19p flat) when it should be dual → Rules 1-4 on the main.

Fix: thread `water_is_off_peak_dual_immersion` (whc 903 + immersion lodged dual
via `_immersion_is_single is False`) into the Unknown-meter branch; when any
text-box trigger is present, resolve via the same Rules 1-4 dispatch (room
heaters → Rule 3 → 10-hour). Single-immersion / instantaneous (whc 909) certs
correctly stay STANDARD (no text-box system).

Worksheet-validated on "simulated case 48" (main 691 + Unknown meter + 903 dual
immersion): Elmhurst 10-Hour Off Peak, SAP 57; ours 45 → 55 (7-hour gives 45,
confirming 10-hour). Flips exactly ONE corpus cert — Apartment 241 (the genuine
-5.38 under-rater, main 691 + dual immersion) -5.38 → -1.05; every other
Unknown+dual-immersion cert already has a storage main (Rule 2). Corpus
within-0.5 holds 72.5%, MAE 0.793 → 0.789 (improved). CO2/PE unchanged.

GSHP/WSHP-main trigger (the other §12 Unknown exception bullet) is a separate
follow-up. Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
000565 e2e 11/11, suite 2987 passed (2 known pre-existing fails). pyright not
installed in this container — strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 09:58:02 +00:00
Khalim Conn-Kowlessar
3548f1f31a docs(tariff): record Unknown-meter off-peak as a verified non-fix (RdSAP 10 §12 Rules, table_12a)
Khalim's hand-built "simulated case 48" Elmhurst worksheet (main 691 room
heaters + Unknown meter + 903 dual electric immersion + cylinder) proves
Elmhurst resolves an Unknown meter + Rule-3 room-heater main to 10-Hour Off
Peak — Elmhurst SAP 57; ours (STANDARD) 45; routing Unknown+Rule3 to off-peak
(10h) gives 55, 7h gives 45 (so Elmhurst uses 10-hour, RdSAP 10 §12 Rule 3,
PDF p.62). So the prior "Rule 3 is not off-peak evidence" comment was wrong
about Elmhurst's behaviour.

But adopting it REGRESSES the lodged-register corpus 72.5%->71.8% / MAE
0.793->0.827: of 11 Unknown+Rule-3 corpus certs only Apartment 241 improves
(-5.38->-1.05); the other 10 overshoot +2.7..+9.1 (Flat 2 +9.11). The
register's meter_type=3 certs were lodged with STANDARD-tariff costing — the
gov-API "Unknown" is lossy and does not mean off-peak. North star is
reproducing the lodged register, not Elmhurst's deliberate-Unknown worksheet,
so KEEP STANDARD (same "Elmhurst != noisy register" family as
roof-windows/shutters).

Comment-only; no behaviour change (corpus gauge unchanged 72.5% / 0.793).
pyright not installed in this container — strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 09:48:21 +00:00
Khalim Conn-Kowlessar
2ac5ec6eb5 chore(tooling): add median column to corpus profiler; document shutter non-implementation
profile_corpus_error.py: print median signed error alongside the mean in each
feature bucket. The mean is dragged by fat-tail register anomalies (e.g. electric
room heaters mean -1.09 but median -0.01) — median is the outlier-resistant lens
for finding TRUE systematic slices, so hunt by |median|, not |signed|.

heat_transmission.py: document why permanent-shutter R is deliberately NOT applied
(Elmhurst uses R=0.04 curtains on every window incl. insulated shutters, proven on
case 46; API-path trial worsens MAE). Comment-only.

pyright not installed locally — strict type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:46:00 +00:00
Khalim Conn-Kowlessar
6a4539f26b fix(fuel): close case 47 — correct the second main heating system's fuel (off-peak pricing + Elmhurst Summary solid-fuel)
Two second-main fuel errors mis-cost a dual-main dwelling whose two main systems
burn different fuels (SAP 10.2 §10a worksheet (213) bills main 2 at its own fuel):

1. Off-peak/legacy scalar cost path (calculator.py + cert_to_inputs.py): main 2's
   kWh was priced at main 1's `space_heating_fuel_cost_gbp_per_kwh` scalar. Split
   main 1 vs main 2 and price main 2 at its OWN rate via the new
   `_main_2_space_heating_fuel_cost_gbp_per_kwh` (+ CalculatorInputs field).
   Scoped to a NON-electric second main (wood/oil/coal) — an electric second
   main keeps main 1's scalar (its off-peak Table 12a split is the deferred §10a
   slice; per-system splitting it regresses the off-peak electric cohort, certs
   13 Parkers Hill / 34 Dunley Road). 0 corpus impact (no corpus cert has a
   non-electric second main on an off-peak meter).

2. Elmhurst Summary mapper (mapper.py): when §14.1 omits the Fuel Type cell, a
   fuel-fired second main (room-heater SAP code) inherited main 1's fuel. Derive
   it from the SAP code's Table 4a category (solid 631-636 -> house coal, gas ->
   mains gas, liquid -> oil) before the main-1 inherit, mirroring
   `_elmhurst_secondary_fuel_from_sap_code` (same modal sub-fuel caveat). Boiler
   codes (<601) still inherit main 1 (case 6 oil rads+UFH).

simulated case 47 (electric room heaters + solid room heaters 633): our SAP
37.81 -> 55.09 vs Elmhurst current 57 (residual is the wood-vs-coal sub-fuel the
Summary export does not carry). Corpus unchanged 72.5% / MAE 0.793; batch 0
raised / 0 diverge; 000565 e2e green. (mapper.py also carries an earlier,
behaviour-free roof-window doc comment.) Spec-cited unit pins added (AAA).
pyright not installed locally — strict type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:46:00 +00:00
Khalim Conn-Kowlessar
44fff76722 fix(fuel): raise UnpricedFuelCode for unrecognised fuels instead of silently defaulting to mains gas
`table_32.unit_price_p_per_kwh` silently returned the mains-gas default
(3.48 p/kWh) for any fuel code it could not resolve to a Table 32 price or a
translatable gov-API enum. An unhandled fuel billed at the gas rate mis-costs
the dwelling (same failure mode as the dual-main wood-vs-electric over-cost).
Raise `UnpricedFuelCode` (new, mirrors MissingMainFuelType / UnmappedSapCode)
so the gap surfaces at the price boundary. `None` (no fuel lodged) still
defaults — callers resolve "no system" upstream.

0 corpus impact: all 1000 certs compute (every lodged fuel resolves), so this
is a forward guard against future/unmapped fuels. Unit pin added; existing
None-default test docstring tightened. pyright not installed locally — strict
type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:31:04 +00:00
Khalim Conn-Kowlessar
702150002f fix(fuel): cost main heating system 2 at its own fuel price, not main 1's (SAP 10.2 §10a worksheet line 213)
Main heating system 2's space-heating fuel cost (worksheet (213)) was billed
at main system 1's Table 32 unit price (`main_2_high_rate_gbp_per_kwh` reused
`main_1_high_rate_gbp_per_kwh`). For a dual-FUEL pair this grossly mis-costs the
second main: cert 10032957680 "Copse Cottage" (main 1 electric room heaters
fuel 30, main 2 wood logs fuel 6) charged its 9481 kWh of wood at 13.19 p/kWh
instead of 4.23 p/kWh — +£850/yr → SAP 21.75 vs lodged 45.

Route main 2 through its own fuel code (`_main_fuel_code(details[1])`), mirroring
the existing secondary-fuel handling. Copse Cottage 21.75 -> 45.94. Corpus
within-0.5 holds 72.5%, SAP MAE 0.815 -> 0.793 (ratcheted ceiling 0.82 -> 0.80);
CO2/PE unchanged. Same-fuel dual mains (gas+gas) unaffected. Off-peak-tariff
dual-fuel mains still defer to the legacy scalar path (separate slice).

Spec-cited unit pin added (AAA). pyright not installed locally — strict type
gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:31:04 +00:00
Jun-te Kim
2afa7acea4
Merge pull request #1251 from Hestia-Homes/feature/hyde_make_it_more_accurate_with_tests
Feature/hyde make it more accurate with tests
2026-06-22 10:04:28 +01:00
Khalim Conn-Kowlessar
a9632937d5 fix(ventilation): use lodged extract-fan count when known, not max(lodged, age default) (RdSAP 10 §4.1 Table 5, PDF p.28)
Table 5 reads "Number of extract fans if known; if number is unknown:
[age-band default]" — the default is an UNKNOWN-fallback, NOT a floor. The
cascade applied `max(lodged, table_5_default)`, flooring a genuinely-lodged
count up to the age-band minimum: e.g. an age H-M dwelling lodging 2 extract
fans was billed at the 6-8-room default of 3, over-counting ventilation line
(8) and the heat-loss coefficient. Fixed to `lodged if lodged > 0 else
default` (a lodged 0 is the Elmhurst/RdSAP "unknown" form → default; any
positive count is taken literally).

Surfaced by Khalim's Elmhurst stress worksheet (simulated case 46): this was
its last ventilation residual — our Jan effective ACH 9.14 -> 9.0748 (exact
match to the accredited worksheet), SAP 29 -> 30 = Elmhurst, cost £1496 vs
£1493. Corpus IMPROVED: within-0.5 71.6% -> 72.5%, MAE 0.819 -> 0.815 (the
max-flooring over-counted ventilation on every cert lodging fans below its
age default). Floor ratcheted 0.71 -> 0.72. pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 06:22:26 +00:00
Khalim Conn-Kowlessar
34e52a893c fix(heating): assume portable-electric secondary for unheated habitable rooms (SAP 10.2 Appendix A.2.2)
When the main heating system does not heat every habitable room (heated rooms
< habitable rooms), SAP 10.2 Appendix A.2.2 assumes the unheated rooms are
served by a portable-electric secondary heater, so the Table 11 secondary
fraction (0.10 for a boiler main) must be costed at the electricity tariff —
even when the cert lodges no explicit secondary system.

`_secondary_fraction` previously returned 0 unless a secondary was lodged or
the main was a forced-secondary electric-storage code, dropping the assumed
secondary and billing 100% of space heat to the (cheaper) main fuel — an
over-rate. Added an `unheated_habitable_rooms` trigger plus
`_has_unheated_habitable_rooms(epc)`, which prefers the lodged
`any_unheated_rooms` flag and guards the gov-API `heated_rooms_count == 0`
"not provided" sentinel. The secondary fuel/efficiency cascade already
defaults to portable electric (code 693) when no secondary code is lodged.

Worksheet-validated on simulated case 46 (heated 4 < habitable 7, no lodged
secondary): the assumed 10% electric secondary (2289 kWh, ~£260) lifted our
SAP 39 -> 29.35 vs accredited Elmhurst 30 (cost £1502 vs £1493, within 0.6%).

Corpus UNCHANGED (71.6% / MAE 0.819): all 17 corpus certs with heated <
habitable already lodge an explicit secondary description, so the gov-API
path was already costing it; this only adds the assumed secondary where none
is lodged (Elmhurst / reduced-field path). pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 06:15:37 +00:00
Khalim Conn-Kowlessar
d7a60efcdf fix(uvalues): thread glazing gap into pre-2002 window U fallback (RdSAP 10 Table 24, PDF p.50)
`u_window` hard-coded the 12 mm gap row for pre-2002 double/triple glazing
(double 2.8, triple 2.1), ignoring the lodged glazing gap. Table 24 splits
the pre-2002 rows by gap: double 6mm=3.1 / 12mm=2.8 / 16mm+=2.7; triple
6mm=2.4 / 12mm=2.1 / 16mm+=2.0 (PVC/wooden), with a metal-frame column
(+0.5/+0.5/+0.5 ish). Added a `glazing_gap` parameter + `_glazing_gap_row`
helper and wired `w.glazing_gap` through the synthesised-window caller in
heat_transmission.

Corpus impact nil by design: the gov-API mapper already resolves per-window
U gap-aware via `_API_GLAZING_TYPE_GAP_TO_TRANSMISSION` (e.g. code 3 + gap
"16+" → 2.7), so corpus certs use that lodged per-window U, not this fallback.
This aligns the reduced-field / worksheet fallback path with the mapper and
Table 24. Unknown gap still defaults to the 12 mm row.

(Metal frames are not distinguishable on the gov-API path — only a `pvc_frame`
boolean exists and Table 24 groups PVC+wooden — so the PVC/wooden U stands
there; the metal column applies only where frame material is lodged.)

Spec-pinned: pre-2002 double + triple gap-row tests. pyright not installed.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-20 14:14:31 +00:00
Jun-te Kim
3044c70202 sap score and elmhirst mapper optimsaiation 2026-06-20 07:25:42 +00:00
Khalim Conn-Kowlessar
fc5f10ea92 fix(rating): floor the continuous SAP score at 1 (SAP 10.2 §13 / RdSAP 10 §13)
The SAP rating is spec-floored at 1 ("if the result of the calculation is
less than 1, the rating is 1"). `sap_rating_integer` already clamps, but the
continuous `sap_score_continuous` did not — so a degenerate dwelling could
emit a physically impossible negative SAP. Apply the same max(1, …) floor to
the continuous value (the un-rounded part is for sensitivity near real
ratings, not for negative ratings).

Removes a -12.3 accuracy outlier on the committed corpus (cert 422000111926,
lodged at the floor of 1, was computing -11.3): within-0.5 70.2% -> 70.3%,
MAE 0.845 -> 0.833. Ratcheted the corpus MAE ceiling to 0.84. Unit-pinned in
test_calculator.

pyright not installed in this codespace (strict gate not run locally).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:03:13 +00:00