Commit graph

6675 commits

Author SHA1 Message Date
Jun-te Kim
12ff15e55b Parse 20.0.0 conservatory building parts so all 1000 certs map 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-10 15:21:00 +00:00
Jun-te Kim
eb5bb89612 Map 20.0.0 lighting, ventilation and hot-water demand fields 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-10 14:46:54 +00:00
Daniel Roth
26d34c345c get last_submission_date from hubspot 2026-06-10 14:45:25 +00:00
Jun-te Kim
3352f11be3 Synthesise 20.0.0 window geometry from glazed-area band and floor area 🟩
ADR-0027 Reduced-Field Synthesis: certs with no per-window array now get total
glazing = 0.148 x TFA x band-multiplier (median + quartile multipliers fit from
the 1000 real 21.0.1 certs), split 4-way across N/E/S/W with width=area/4,
height=1.0; glazing_type routed through the verified 21.0.1 cascade. Also guard
optional PhotovoltaicSupply.none_or_no_details (a parse straggler). Corpus maps
983/1000, up from 974.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-10 14:29:13 +00:00
Jun-te Kim
8074f4152c Map RdSAP 20.0.0 certs that omit reduced fields or lodge localised text 🟩
Required->optional defaults (kw_only + data-driven from corpus presence) so
993/1000 certs that omit sap_windows parse, and honest Union[str, DescriptionV1]
typing for description/dwelling_type which the corpus lodges as localised dicts
in ~half the certs. The never-run 20.0.0 mapper path now produces EpcPropertyData;
974/1000 corpus certs map (xpass), up from 7.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-10 14:14:18 +00:00
Jun-te Kim
5589a66e7c Document RdSAP 20.0.0 Reduced-Field Synthesis (CONTEXT.md term + ADR-0027)
Sharpen the glossary to decouple deterministic old-schema re-mapping from
neighbour-prediction gap-fill (a separate, unimplemented ML path), and add
the Reduced-Field Synthesis term. ADR-0027 records the pre-SAP10 20.0.0
mapper's best-attempt synthesis (corpus-fit glazing 0.148xTFAxband, 4-way
orientation) and its trade-offs. Grill resume doc captures every resolved branch.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-10 14:14:18 +00:00
Daniel Roth
64e20ebb91
Merge pull request #1212 from Hestia-Homes/feature/audit-generator/switch-template
Use new template for ventilation audit
2026-06-10 14:40:14 +01:00
Daniel Roth
a2a9566ef2 delete previous template 2026-06-10 13:34:05 +00:00
Daniel Roth
8976f55636 add todo comment for named ranges 2026-06-10 13:32:11 +00:00
Daniel Roth
131b0884c7 update template file 2026-06-10 13:26:56 +00:00
Daniel Roth
0edeeaefa6 populate_sheet writes to new Sero template column layout 🟩 2026-06-10 13:21:50 +00:00
Daniel Roth
e7954ad83a
Merge pull request #1210 from Hestia-Homes/bug/audit-generator-deploy-fix
Update subtask_handler to work for handlers where TaskOrchestrator is optional
2026-06-10 14:04:20 +01:00
Daniel Roth
921dc5108b revert pytest.ini 2026-06-10 12:59:06 +00:00
Daniel Roth
44b4882841 Merge branch 'main' into bug/audit-generator-deploy-fix 2026-06-10 12:53:18 +00:00
Daniel Roth
8ff58bd645 tell subtask_handler whether to send TaskOrchestrator to handler, defaulting to True 2026-06-10 12:43:24 +00:00
Khalim Conn-Kowlessar
e89b4041c7 test(efficiency): lock solid-fuel room-heater space eff to Table 4a column (B)
An API audit flagged the solid-fuel room-heater space efficiencies
(_SPACE_EFF_BY_CODE 631-636) as reading the "Water" column of SAP 10.2
Table 4a. That was a misread: the two room-heater columns are (A)
minimum-for-HETAS-approved and (B) other appliances — BOTH are space
efficiency, not space/water. RdSAP defaults to column (B) when HETAS
approval is not lodged, which is what these values already hold and what
the reference software produces (Elmhurst worksheet "solid fuel 9", SAP
code 636 → (206) space efficiency = 70 = column B; flipping to column A
75 broke that pin and three sibling solid-fuel corpus pins).

No value change — add a pin test + spec-cited comment so the column-(A)/
(B) distinction is explicit and this misread can't recur.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 11:09:12 +00:00
Khalim Conn-Kowlessar
07f534ee11 feat(modelling): system tune-up options (standard + zone controls)
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:

- system_tune_up        — standard controls (programmer + room thermostat +
  TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned  — time-and-temperature zone control (code 2110, type 3):
  more SAP uplift for more cost

Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.

Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).

Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 10:20:46 +00:00
Khalim Conn-Kowlessar
5a74897fed fix(water-heating): gate DHW separate-timing on programmer + boiler age (RdSAP 10 §10.5)
`_separately_timed_dhw` returned True for any boiler+cylinder+from-main
cert, applying the SAP 10.2 Table 2b note b) ×0.9 temperature-factor
reduction unconditionally. For the lpg-boiler "before" worksheet (pre-
1998 LPG boiler SAP code 115 + 210 L cylinder, NO cylinder thermostat,
control 2113 "Room thermostat and TRVs" — no programmer) this dropped
the (53) temperature factor to 0.702 (= 0.60 × 1.3 × 0.9) where the
worksheet lodges 0.78 (= 0.60 × 1.3), under-counting cylinder storage
loss (55) by ~119 kWh/yr and over-rating SAP by ~0.25.

RdSAP 10 §10.5 (PDF p.57) "Hot water separately timed":
    No programmer, pre-1998 boiler → No
    Programmer, pre-1998 boiler    → Yes
    Post-1998 boiler               → Yes
DHW is therefore NOT separately timed only when a pre-1998 boiler is
paired with a no-programmer control. Add the two SAP 10.2 Table 4c(2) /
Table 4b lookups (controls without a programmer = {2101, 2103, 2111,
2113}; pre-1998 gas/LPG boilers 110-119 + oil 124/125/128) and return
False for that combination; every other boiler+cylinder cert keeps the
separately-timed default, so the change is confined to old low-control
stock and the heating corpus + goldens are unchanged.

Effect: the full chain (Summary PDF → extractor → mapper → cert_to_inputs
→ calculator) now reproduces the lpg-boiler worksheet's §11a unrounded
SAP -6.6499 at abs < 1e-4 (was -6.4013). Full regression suite green bar
the 3 pre-existing unrelated fails.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 10:07:27 +00:00
Daniel Roth
3ceafe8b49
Merge pull request #1208 from Hestia-Homes/bug/audit-generator-task-orchestrator
Pass unused TaskOrchestrator to audit generator handler to avoid TypeError
2026-06-10 10:36:18 +01:00
Daniel Roth
5c4999aade unused task orchestrator in handler signature 2026-06-10 09:30:38 +00:00
Daniel Roth
2c605f80ca pass task orchestrator to handler 2026-06-10 09:29:46 +00:00
Khalim Conn-Kowlessar
90de1fc976 fix(elmhurst-mapper): map "Bottled gas" main fuel to bottled LPG, not mains gas
An LPG-boiler dwelling on the Summary → from_elmhurst_site_notes path
mapped to main_fuel_type=26 (mains gas), making it indistinguishable
from a mains-gas boiler downstream — wrong Table 12/32 cost / CO2 / PE
(bottled LPG is ~10.30 p/kWh vs mains gas 3.48), and it defeats any
"non-gas → gas only with a mains-gas connection" gate (an LPG dwelling
looks already-gas).

Root cause: the recommendation worksheets lodge the boiler carrier as
§15.0 "Water Heating Fuel Type: Bottled gas" (§14.0 carries only SAP
code 115, a Table 4b gas-family row, + "Main gas: Yes" in §14.2 — a
mains-gas CONNECTION, not the heating fuel). "Bottled gas" was absent
from `_ELMHURST_MAIN_FUEL_TO_SAP10`, so the §15.0 fuel resolved to None
and `_elmhurst_gas_boiler_main_fuel` fell through priority-1 to the
mains-gas meter flag → 26.

Map "Bottled gas" → 3 (bottled LPG MAIN heating): code 3 routes via
`API_FUEL_TO_TABLE_32`/`API_FUEL_TO_TABLE_12` → Table-code 3 (10.30 /
9.46 p/kWh). NOT the legacy "LPG bottled": 5 entry — API code 5 =
anthracite, and `canonical_fuel_code` resolves the same-valued Table-32
code 5 to anthracite (3.64 p/kWh), so a 5 here mis-prices the dwelling
as cheap solid fuel (verified: a 5 mapping moved SAP the WRONG way,
42.33 → 45.11; code 3 moves it to -6.40 vs the worksheet's -6.6499).
Also add 3 to `_GAS_LPG_MAIN_FUEL_CODES` so the §15.0-lodged bottled-LPG
water fuel is adopted as the boiler's space-heating carrier (priority 1)
instead of the meter flag.

Effect: main_fuel_type=3 (bottled LPG) and water_heating_fuel=3 (was
None). Mains-gas certs still → 26 (full regression suite green bar the 3
pre-existing unrelated fails); the MissingMainFuelType tripwire still
fires for genuinely-undeterminable carriers.

Spec: SAP 10.2 Table 12 / RdSAP 10 Table 32 (PDF p.95) — bottled LPG
main heating fuel code 3.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:48:15 +00:00
Khalim Conn-Kowlessar
3d108a9d9e feat(harness): explain gas_boiler_upgrade in the report triggers
Add the `gas_boiler_upgrade` branch to `report._triggers_for`, mirroring the
generator's eligibility guard so a cohort report explains why the boiler upgrade
fired: the wet-boiler SAP code, the mains-gas connection that makes the gas
end-state installable, and the cylinder presence that shapes the bundle (combi
vs regular + cylinder fixes).

No golden API cert selects the boiler upgrade (it competes with — and on houses
loses to — the ASHP bundle within the one heating Recommendation), so the branch
is covered by a direct `_triggers_for` unit test, following the repo pattern for
testing internal helpers (cert_to_inputs).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:44:37 +00:00
Daniel Roth
bb1c8c88ce Two-parameter subtask handler completes without TypeError 🟩 2026-06-10 08:40:32 +00:00
Khalim Conn-Kowlessar
2413bc87da feat(modelling): solid-fuel(coal)->gas boiler upgrade + boiler_flue_type end-state
Pin the coal-boiler-with-cylinder upgrade and add the `boiler_flue_type`
end-state field. A solid-fuel (coal) boiler (fuel 11, SAP code 153) on a
mains-gas street converts to a gas condensing boiler (fuel 11->26, code 102) —
the non-gas->gas path for a solid-fuel system, eligible because code 153 is in
the wet-boiler solid-fuel range 151-161 and mains gas is present.

New `boiler_flue_type` HeatingOverlay field, routed to main_heating_details[0]
and set to 2 (room-sealed/balanced) on both boiler shapes: every relodged after
lodges flue type 2, but coal's before lodged none. The field is SAP-inert (the
cascade score is unchanged by it), so it is written purely for end-state
fidelity — the overlay now represents the installed condensing boiler's flue.
Validated via the overlay-equality unit tests.

The coal after predates the user-locked "always add a cylinder thermostat when
absent" rule, so it stale-lodged thermostat 'N'; the pin corrects it to the
rule's end-state 'Y' in-test (the gas with-cylinder after got the same
correction by re-lodging). The cylinder is already 80 mm insulated, so the
jacket is skipped and only the thermostat is added; controls (2106) are
unchanged. Cascade-pinned delta 0 (SAP/CO2/PE).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:27:07 +00:00
Daniel Roth
51cf545776 Two-parameter subtask handler completes without TypeError 🟥 2026-06-10 08:22:43 +00:00
Khalim Conn-Kowlessar
b473f6a1ec fix(elmhurst-mapper): classify top-floor flat from roof type, not room-in-roof
`_elmhurst_dwelling_type` derived a flat's roof exposure from
`room_in_roof is not None`, so a top-floor flat whose roof is a plain
external "PS Pitched, sloping ceiling" (no room-in-roof) fell through to
"Mid-floor flat". The cascade's `_dwelling_exposure` then treats a
mid-floor flat's roof as a party ceiling (RdSAP 10 §5 / §3 — party
surfaces carry no heat loss) and drops the entire roof term: cert
001431's 105 m² roof at U=2.3 = 241.68 W/K (30) vanished, collapsing
(33) fabric heat loss 320.06 → 78.38 and over-rating SAP by ~5 points
(on top of the age-band roof-U bug — see prior commit).

Read the roof TYPE instead — the dual of the floor's "Another dwelling
below" signal. A flat's roof is a party ceiling only when its Elmhurst
code is S / A / NR (Same/Another dwelling or Non-residential space
above); F / PN / PA / PS are exposed external roofs, so the dwelling is
on the top storey. `has_exposed_roof = room_in_roof present OR
_elmhurst_roof_is_exposed(roof)` — which is exactly what the function's
own docstring already described as the intent ("RR present or external
roof"), now implemented.

With both upstream fixes the full chain (Summary PDF → extractor →
mapper → cert_to_inputs → calculator) reproduces the worksheet's §11a
unrounded SAP 56.3649 at abs < 1e-4, with (30)/(33)/(37) matching to
the decimal. Only flat fixture reclassified; 000784 (top-floor, RR) and
000910 (ground-floor) unchanged. Regression suite green bar the 3
pre-existing unrelated fails.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:18:51 +00:00
Jun-te Kim
14dc4efeed save so i can continue 2026-06-09 17:07:55 +00:00
Khalim Conn-Kowlessar
1033526812 fix(elmhurst-extractor): read Main Property age band from §3.0 Date Built block
The Elmhurst Summary §3.0 "Date Built" lodges the per-building-part age
bands; the Main row reads "Main Property" / "C 1930-1949". But "Main
Property" ALSO heads the §4.0 Dimensions table, so the global
`_str_val("Main Property")` collides with it: when pdftotext renders
"3.0 Date Built:" glued onto its "Main Property" row token on one
layout line (as the recommendation worksheets do), the first standalone
"Main Property" match is the §4 dimensions header — returning its next
token "Floor" as the "age band".

That garbage age propagated to `u_roof`: for a "Pitched, sloping
ceiling" (PS) roof with no lodged insulation thickness, `u_roof` returns
the spec uninsulated U=2.3 for the correct age C but U=0.4 for the
unparseable "Floor" — collapsing the roof heat-loss term and inflating
SAP by ~14 points on the affected cert.

Scope the read to the Date-Built block (between "3.0 Date Built" and
"4.0 Dimensions") and take the first age row — a line beginning with a
single A-M band letter + space ("C 1930-1949", "A before 1900",
"J 2003-2006"). Building-part name rows never start that way, and the
Main row precedes any extension / room-in-roof rows.

Regression: full sap10_calculator + documents_parser suite green bar the
3 pre-existing unrelated fails (2 stone-wall U tests, test_total_floor_
area); the multi-bp / "A before 1900" fixtures (000516, 001431_case*,
6035) keep their age bands.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:41:00 +00:00
Khalim Conn-Kowlessar
7bc9797a26 test(modelling): pin non-gas->gas + already-insulated-cylinder boiler upgrades
Two more boiler-upgrade cascade pins, validating the existing generator across
fuels and cylinder states (no source change):

- oil combi: an oil boiler (fuel 28, code 130) on a mains-gas street converts to
  a gas condensing combi (fuel 28->26, code 104). Proves the non-gas -> gas
  conversion gated on a mains-gas connection (ADR-0024 revised).
- already-insulated cylinder: a gas boiler heating a pre-jacketed cylinder
  (type 2 / 80 mm, no thermostat) gets a new boiler + a thermostat, with the
  jacket NOT re-applied. Proves the cylinder path's skip-jacket branch against a
  real cert. (Sourced from an LPG re-lodgement whose fuel the Summary mapper
  reads as mains gas 26 — a separate LPG fuel-mapping gap, noted in the test.)

Both pin delta 0 (SAP/CO2/PE) against the relodged after.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:37:32 +00:00
Khalim Conn-Kowlessar
63dd69ff8b feat(modelling): gas combi boiler upgrade + controls-when-inadequate
Extend the gas-boiler-upgrade Option to combi (no-cylinder) dwellings and add
the controls upgrade shared by both boiler shapes. A dwelling has a cylinder or
it does not, so the one `gas_boiler_upgrade` Option is shaped per dwelling:

- no cylinder -> a gas condensing combi (Table 4b code 104), no cylinder fields
  touched;
- a cylinder  -> a regular boiler (code 102) heating it, with the conditional
  cylinder jacket/thermostat (slice 1).

Controls: bring an inadequate boiler control up to full programmer + room
thermostat + TRVs (SAP 10.2 Table 4e Group 1 code 2106). "Inadequate" = the
Group-1 codes with NO room thermostat (2101, 2102, 2107, 2108, 2109, 2111) —
these lack boiler interlock (Table 4c(2) / footnote c) p.171), so adding a room
thermostat genuinely improves SAP. Room-thermostatted (2103/2104/2105/2106/2113)
or better zone controls (2110/2112) are left unchanged — never downgraded, so
no phantom uplift. The with-cylinder cert (control 2106) is therefore untouched
and its pin still holds at delta 0.

Validated by the combi before/after re-lodgement (cert 001431, gas boiler
upgrade - no cylinder): control 2111 "TRVs and bypass" -> 2106, fan flue
False->True, SAP code 112 -> 104. Cascade-pinned delta 0 (SAP/CO2/PE). Removed
the slice-1 placeholder test asserting no boiler Option fires without a cylinder
(the combi Option now correctly fires there).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:28:00 +00:00
Khalim Conn-Kowlessar
31c74ab500 feat(modelling): gas-boiler-upgrade-with-cylinder option in the heating rec
Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.

The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:

- Target is always a gas condensing boiler, not fuel-preserving: every after
  lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
  mains-gas connection; electric boilers are left alone (electrification is the
  upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
  151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
  + cylinder). The calculator derives the condensing seasonal efficiency from
  the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
  `fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
  the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
  field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
  the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
  cylinder is below 80 mm (never downgrading a better one). Both are conditional
  per-dwelling components, not a frozen overlay.

Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.

Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 16:16:46 +00:00
Jun-te Kim
3b7d26fe34 added test for a 1000 examples 2026-06-09 16:02:21 +00:00
Daniel Roth
f6a4b0f722
Merge pull request #1206 from Hestia-Homes/bug/audit-generator-deploy-fix
Add missing variable to lambda variables
2026-06-09 16:39:34 +01:00
Daniel Roth
c1dda41857 add missing variable to lambda variables 2026-06-09 15:33:35 +00:00
Daniel Roth
63b1fa08a8
Merge pull request #1204 from Hestia-Homes/feature/generate-ventilation-audit-from-magicplan
New application to generate ventilation audit file for a given hubspot deal ID
2026-06-09 16:25:12 +01:00
Daniel Roth
dcd5204b54 put db engine construction inside handler to avoid import errors in test 2026-06-09 15:18:42 +00:00
Khalim Conn-Kowlessar
590cb97ef6 docs: session-9 close-out + session-10 handover (summary-report-based audit)
Session 9 ran five independent data-driven audits (profiler, dropped-field scan,
CO2/PE reconciliation, cross-provider LIG parity, HW-demand reconciliation) — all
converged on diffuse remaining gap — and shipped glazing Table-24 (+16 certs) +
HW-only heat-network DLF, taking 54.90% -> 56.8% within-0.5. The data-driven seam
is exhausted; session 10 switches to worksheet-level ground truth via the
summary-report-based per-cert audit. New agent prompt at HANDOVER_SUMMARY_AUDIT.md
with method, starter candidate certs, ruled-out list, and conventions.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 14:54:08 +00:00
Daniel Roth
236f33c25f move spreadsheet population logic to domain 2026-06-09 14:43:24 +00:00
Daniel Roth
48a413a5e2 correct imports in postgres repo 2026-06-09 14:25:29 +00:00
Daniel Roth
94f8ef5458 Merge branch 'main' into feature/generate-ventilation-audit-from-magicplan 2026-06-09 14:22:57 +00:00
Daniel Roth
163703285f deployment 2026-06-09 14:15:52 +00:00
Daniel Roth
b9eb23f6df allow write to real s3 when running locally 2026-06-09 13:52:39 +00:00
Khalim Conn-Kowlessar
872bc585f7 fix(hot-water): apply Table 12c distribution loss to HW-only heat networks (whc 950/951/952)
The heat-network HW distribution-loss override fired only when the MAIN was
a heat network AND whc inherited from main ({901,902,914}). Water-heating-only
heat networks (SAP 10.2 Table 4a HW codes 950 boilers / 951 CHP / 952 heat
pump) were missed entirely: their Table 4a plant efficiency applied with NO
distribution loss, so the HW fuel was under-counted by the Table 12c DLF
(1.33-1.48x) → under-cost → over-rate.

RdSAP 10 §10 (spec p.36): a water-heating-only heat network is calculated 'for
plant efficiency, distribution loss and pumping energy - see Table 12c'. Added
a whc-gated branch (independent of the main) applying water_eff = plant_eff /
DLF — the per-kWh-generated cost model (q_generated = q_useful x DLF). Fires on
the WHC alone so a HW-only heat network with a non-network main (cert 9093, whc
950 + warm-air main 502) is covered.

The 3 corpus whc=950 certs all improve in |err|: 2153 +2.62->-0.48 (now within
0.5), 7220 +1.27->-0.97, 9093 +6.04->+3.60 (residual is its warm-air main, a
separate cause). within-0.5 56.66->56.79%, within-1.0 71.9->72.2%, mean|err|
down; only those 3 certs change. New AAA test pins the DLF scaling fires on the
WHC independent of the main. Goldens + gate green, pyright net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 13:40:17 +00:00
Daniel Roth
608006d977 reapply conditional formatting to populated file 2026-06-09 13:29:11 +00:00
Khalim Conn-Kowlessar
a7990edb8c robustness: strict-raise on unmapped glazing + heating/HW efficiency codes
Forcing-function guards so a lodged-but-unmapped code surfaces loudly instead
of silently taking a wrong-but-plausible default (the class that hid single
glazing as U=2.5 until this session). Four silent fallbacks converted to raise
on PRESENT-but-unmapped codes, while keeping the legitimate ABSENT (None)
defaults:

- _api_glazing_transmission: unmapped glazing_type -> UnmappedApiCode (was
  None -> u_window all-None default 2.5).
- _api_cascade_glazing_type: unmapped glazing_type -> UnmappedApiCode (was
  pass-through -> wrong g-value slot).
- seasonal_efficiency: a lodged code/category resolving in neither
  _SPACE_EFF_BY_CODE nor the category/room-heater fallbacks -> UnmappedSapCode
  (was blind 0.80 gas-boiler default, which 'catastrophically misrates heat
  pumps and storage' per the table comment). Data-free calls keep 0.80.
- water_heating_efficiency: WHC in no SAP 10.2 Table 4a HW row ->
  UnmappedSapCode (was blind 0.78). Absent code keeps 0.78.

Zero current-corpus impact (909 computed / 0 raises, 56.66% within-0.5
unchanged) — the code/efficiency tables are complete for today's data, so
these are guards for the ongoing audit + future data refreshes. Verified the
WHC table already covers 908 (multi-point gas) and 950 (HW heat network), so
those are NOT unmapped-code bugs. 8 AAA tests, goldens + gate green, pyright
net-zero.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-09 13:21:13 +00:00
Daniel Roth
f8c955b2d3 local runner and correct template path 2026-06-09 13:03:05 +00:00
Daniel Roth
e010fa1b40 remove redundant files 2026-06-09 12:52:04 +00:00
Daniel Roth
e11ab85d9d
Merge pull request #1202 from Hestia-Homes/bug/magicplan-task-handler
Use correct task handler decorator for magicplan
2026-06-09 13:36:12 +01:00
Daniel Roth
ea899fe0ab actually revert changes 2026-06-09 12:27:57 +00:00