Two mapper extensions, both validated by 000490 closing to 1e-4:
1. Secondary heating extraction. Elmhurst Summary PDFs lodge the
secondary heating SAP code in the §14.1 Main Heating2 sub-section
(between "14.1 Main Heating2" and "14.1 Community Heating") — not
in the §14.0 Main Heating1 block where the main system lives.
`ElmhurstMainHeating` gains a `secondary_heating_sap_code` field;
the extractor reads it from the right section; the mapper threads
it through to `SapHeating.secondary_heating_type`. The cascade
then applies Table 11's 10% secondary fraction.
2. Sheltered-sides derivation per RdSAP §S5. The Summary PDF doesn't
lodge per-dwelling sheltered-sides; the value is derived from
built-form (Detached=0, Semi-Detached=1, End-Terrace=1, Mid-
Terrace=2, Enclosed Mid-Terrace=3, Enclosed End-Terrace=2).
`_map_elmhurst_ventilation` now takes built_form and populates
`SapVentilation.sheltered_sides`. The table is cross-checked
against U985-0001-NNNNNN.pdf line (19) across the 6 worksheet
fixtures.
Cohort SAP deltas after this slice (target 1e-4):
000474 0.0000 ✓ Slice 47
000477 +2.6555 diagnosis pending (lighting bulb count diff)
000480 +4.1955 diagnosis pending
000487 +4.4553 extractor still drops most windows
000490 0.0000 ✓ THIS SLICE
000516 +1.5162 roof-window separation
Pyright net-zero on touched files (35 errors, same baseline). 755
tests pass (up from 754 — new `test_summary_000490_full_chain_sap_
matches_worksheet_pdf_exactly`).
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
The §11 Windows table in the Summary PDF doesn't lay out identically
across the cohort. Three new quirks added to the layout-style parser
so the remaining 5 certs can be debugged with windows actually
extracted:
1. `Wood 0.70` combined frame_type+frame_factor line — previously the
parser expected them on separate lines (data+1 / data+2) and
rejected the window when the joined form appeared.
2. Trailing glazing-type on the data line — `1.22 1.76 2.15 Double
pre 2002` is the joined-cell variant in 000516; the W/H/Area
anchor now captures the trailing phrase as an optional 4th group
and feeds it through as `inline_glazing_type`, bypassing the
separate-line glazing-prefix scan.
3. Cross-window gap with no glazing marker — `_partition_after_manuf`
now falls back to "second orientation token in gap" when no
glazing-type-prefix word appears. Covers the 000516 layout where
each window has prefix+suffix orient tokens (no inline orient)
and the glazing-type is joined-to-data.
The 5 remaining Summary PDFs are copied into
`backend/documents_parser/tests/fixtures/` ready for per-cert mapper
work. Mirror pin tests deferred — each cert still has its own diff
to close (handover in NEXT_AGENT_PROMPT.md documents the per-cert
state, e.g. 000477 needs secondary-heating extraction, 000516 needs
roof-window separation).
Current cohort SAP deltas vs the U985 worksheet PDFs (target 1e-4):
000474 0.0000 ✓
000477 +6.3655 secondary heating + lighting
000480 +8.2695 diagnosis pending
000487 +8.1433 extractor still drops windows
000490 +5.6551 diagnosis pending
000516 +5.9812 roof-window separation
Wider regression stays green (754 pass). Pyright net-zero on
touched files.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
Two diffs closed against the hand-built `_elmhurst_worksheet_000474`
target (SAP 62.2584):
1. `pumps_fans_kwh_per_yr` (130 → 160). The cascade keys §4f pumps+fans
electricity on `MainHeatingDetail.main_heating_category` (gas-fired
boilers = cat 2 → 160 kWh/yr). `from_elmhurst_site_notes` wasn't
populating the field, so it fell through to the default 130. Added
`_elmhurst_main_heating_category` deriving cat 2 for the gas/LPG-
PCDB-boiler branch; other categories deferred until a fixture
exercises them (consistent with the cascade lookup).
2. Window [4] orientation `East-South` → `East` and window [5]
orientation `''` → `South-East`. The layout-style parser's
`before_start = prev_manuf + 7` / `after_end = next_data` rule was
over-grabbing prefix tokens of W_{k+1} as suffix tokens of W_k
('South' from W_5's prefix bled into W_4's suffix). Replaced with
a symmetric partition on the first glazing-type-start token
(`Single`/`Double`/`Triple`/`Secondary`) within the cross-window
gap, used as the upper bound of W_k's suffix and the lower bound
of W_{k+1}'s prefix. Same boundary on both sides — prefix tokens
of the next window can no longer be attributed as suffix of the
current one.
After both fixes, Summary_000474 → ElmhurstSiteNotes → EpcPropertyData
→ cascade → SAP matches the worksheet PDF's unrounded line 257 value
to 1e-4 tolerance. All 754 datatypes/epc/ + backend/documents_parser/
tests green; pyright net-zero on touched files.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
The legacy `_extract_windows` regex anchors on "Permanent Shutters\n" which is broken across lines by the pdftotext-layout preprocessor. New fallback `_extract_windows_from_layout` anchors on the two stable per-window markers — a "W H Area" data line and the "Manufacturer <U_value>" line a few lines further down — and tolerates the variable-order optional fields (glazing_gap, inline building_part, inline orientation) between them. Prefix/suffix tokens around the data block are re-joined into glazing_type / building_part / orientation strings.
Cert U985-0001-000474's 7 windows across Main + 2 extensions now flow through the mapper to EpcPropertyData.sap_windows (was 0). Textract-style extraction (existing fixture) is unchanged — the legacy path runs first and only falls through when its regex misses.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
ElmhurstSiteNotes had no representation for extensions: singular dimensions / walls / roof / floor fields could only describe the main bp. Summary PDFs lodge "1st Extension" / "2nd Extension" subsections in §4, §7, §8, §9 with optional "As Main: Yes" inheritance. This slice:
- Adds `ExtensionPart` dataclass and `ElmhurstSiteNotes.extensions: List[ExtensionPart]`.
- Adds `_split_section_by_bp` helper + per-bp parsing of dimensions / walls / roof / floor in the extractor; "As Main" inherits from the main bp.
- Refactors `_map_elmhurst_building_part` into a parameterised builder; adds `_map_elmhurst_building_parts` that yields Main + one SapBuildingPart per extension (capped at 4 per RdSAP10 §1.2).
- Scaffold test `test_summary_000474_mapper_produces_three_building_parts` flips from strict-xfail to passing.
Single-bp behaviour is unchanged (empty extensions list defaults). 752 existing tests stay green.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>