The full RdSAP-Schema-21 label is "Double between 2002 and 2021" (double
glazing installed 2002-2021, SAP 10.2 Table 24 code 3). When the Elmhurst
Summary PDF wraps the trailing "and 2021" into an adjacent table cell that
the extractor joins away, the surfaced label truncates to "Double between
2002" — the same artifact already handled for "Triple post or during".
`_elmhurst_glazing_type_code` raised UnmappedElmhurstLabel on it, blocking
the whole Summary (surfaced on the simulated-case-46 multi-attribute
worksheet). Added the truncated form as a code-3 alias.
pyright not installed in this container.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The Baseline stage is the first consumer to read these off a persisted EPC
end-to-end, surfacing three gaps that only manifest on real API data:
- Only the 21.0.1 mapper copied through the recorded current-performance
scalars (SAP rating, CO2, PEUI) and *no* mapper mapped the EPC band, so
Lodged Performance raised for 17.x/18.0/19.0/20.0.0 certs. Overlay all four
from the raw payload in `from_api_response`, once, for every schema version.
- Likewise the `renewable_heat_incentive` block (baseline space/water-heating
kWh) was only mapped by the 21.x paths. Gap-fill it centrally from the raw
payload when a mapper left it unset.
- The FE-owned `epc_property` date columns are Postgres `timestamp`s while the
SQLModel mirror types them `str`, so a read hands back a `datetime` and
`date.fromisoformat()` raised. Normalise via `_as_date()`.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The gov API lodges a NON-SEPARATED conservatory (conservatory_type=4) as a
glazed "building part" carrying only {floor_area, room_height,
double_glazed, glazed_perimeter} — no fabric, no floor dimensions. The
four fields were undeclared on the 21.0.1 SapBuildingPart, so `from_dict`
dropped them and the conservatory was silently lost: it billed no §6.1
window/rooflight/floor and added nothing to TFA (5 corpus certs over-rated
— too little heat loss → SAP too high).
Fix (21.0.1 schema + mapper):
- declare the four glazed fields on `SapBuildingPart`;
- `_api_sap_conservatory` builds `EpcPropertyData.sap_conservatory` from
the glazed BP (identified by a lodged `glazed_perimeter`; only type-4
conservatories lodge it — separated ones, §6.2, lodge nothing);
- exclude the glazed BP from the fabric building-part loop (it is billed
by the §6.1 cascade, not as a dwelling part);
- `_total_floor_area_from_building_parts` adds the conservatory floor area
to TFA (drives occupancy → §4/§5 demand).
Validation is cross-mapper parity, NOT a corpus back-solve: the API mapper
feeds the SAME worksheet-validated §6.1 cascade (`conservatory_geometry`,
pinned to 1e-4 against the case-44 Summary) as the Elmhurst path — so the
API conservatory fabric is correct by construction. `from_api_response`
on an injected type-4 cert reproduces the glazed wall (perimeter × ground-
floor room height = 22.05), glazed roof (floor/cos20 = 12.77) and Table 25
double U_eff (2.758 wall / 2.993 roof); a separated (type 2/3) cert lodges
no glazed BP → disregarded per §6.2.
Gauges: corpus within-0.5 67.9% → 68.6% (MAE 0.959 → 0.942; floor 0.67→0.68,
ceiling 0.97→0.95); /tmp eval mean|err| 0.822 → 0.817. Harness 47/47
0-raised; regression = the 3 pre-existing fails; pyright net-zero (65=65).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Close the §6.1 conservatory demand cascade per RdSAP 10 §6.1 + Table 25.
Solar gains (§6, solar_gains.py) — Table 25 note (PDF p.51): "The
orientation of windows in a conservatory is not recorded, thus solar
gains are calculated using the default solar flux (East/West orientation,
with 20° pitch for roof windows)." The glazed wall bills onto the (76)
East line (vertical, average-overshading Z); the glazed roof onto the
(82) roof-window line (20° pitch, Z=1.0), both at Table 25 g=0.76, FF=0.70.
TFA-occupancy (mapper) — §6.1: the conservatory floor area is added to the
dwelling total floor area. TFA drives occupancy → §5 internal gains + §4
hot-water demand, so the non-separated conservatory's floor area now
enters `EpcPropertyData.total_floor_area_m2` (the worksheet's (4) = 95.38
carries it). Separated conservatories (§6.2) stay excluded.
Pinned against the case-44 P960 demand cascade at abs=1e-4: (73) internal
gains 625.1759, (83) solar gains 495.8655, (95) useful gains 1079.6510,
(99) space heating per m² 89.8073 — the full §6.1 chain reproduces EXACTLY.
The whole-dwelling SAP (72.9517) / CO2 (3241.8656) are not pinned: the
case-44 Summary omits the House-Coal secondary heater (SAP 633) the P960
descriptor carries (cf. case 43), so the cascade computes no secondary —
the entire residual (+349.77 kg CO2). A Summary-input defect, independent
of §6.1; every conservatory-affected line ref is exact. Worksheet harness
stays 47/47 0-raised; corpus unchanged (API path; mirror is the next slice).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 §2 (17)-(18): a measured/design air permeability at 50 Pa from a
Blower Door test routes infiltration via `(18) = AP50/20 + (8)`, in
preference to the components-based (16) estimate. The Elmhurst extractor
read only the AP4 ("Pulse") column of §12.2, so a Blower Door result
(§12.2 "Pressure Test Result (AP50)") fell through to the structural-
infiltration default — over-counting ventilation heat loss.
Surfaced by simulated case 44 (AP50 4.50): effective air change rate was
0.81 vs the worksheet's 0.58 (+38% ventilation loss). The cascade already
supports `air_permeability_ap50` (preferred over AP4); this wires the read
end to end (extractor → ElmhurstSiteNotes → SapVentilation → cert_to_inputs).
Pinned against the case-44 P960 §2 at abs=1e-4: (18) infiltration 0.3417
(= 4.5/20 + 0.1167) and (25) Jan effective ach 0.5812. Worksheet harness
stays 47/47 0-raised.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Some SAP-Schema-17.x/18.0.0 certs lodge sap_openings width/height in MILLIMETRES
mixed with metre rows in the same array (e.g. a 2025x2100 mm window beside a
3.06x1 m one). The 17.1 mapper read them all as metres → a 4.25M m2 window →
HTC in the millions → SAP clamped to 1.
Fix (TDD, datatypes/epc/domain/mapper.py): _sanitise_opening_dimension_m treats
any dimension > 50 m as mm and divides by 1000; _sap_opening_area_m2 applies it
to areas. Wired into the window, roof-window, and door-area-weighting paths.
The 3 broken certs (uprn_10093117227 / 10090317693 / 10091636031) now score
90 / 81 / 79 instead of 1.
3 RED->GREEN slices + refactor; new test class
TestFromSapSchema17_1OpeningUnitSanitisation + sap_17_1_mm_openings.json fixture;
0 new pyright errors; no regressions.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Schema coverage (datatypes/epc/domain/mapper.py):
- SAP-Schema-18.0.0: full-SAP shape ≡ 17.1 → from_sap_schema_17_1, no normalisation.
- SAP-Schema-16.0: same reduced-field 16.x path; default the omitted `tenure`
field in _normalize_sap_schema_16_x (metadata; SAP cascade never reads it).
Genuinely sparse 16.x certs (missing core fabric fields) still fail loud.
- Regression tests + sap_18_0_0.json / sap_16_0.json fixtures; 0 new pyright errors.
Autonomous triage of the worklist (scripts/hyde/autonomous_run_findings.md):
- Found + diagnosed 2 bugs (flagged, NOT fixed): (1) MAPPER — full-SAP openings
lodged in mm read as m → multi-million-m2 windows → SAP clamps to 1 (uprn_
10093117227 / 10090317693 / 10091636031); (2) CALCULATOR — database heat-pump
fuel code 39 mis-priced as gas, over-rates ~14 (uprn_10093114053).
- Most certs map within +/-4 of lodged.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- SAP-Schema-16.3: same reduced-field RdSAP shape as 16.2 — generalise the
normaliser to _normalize_sap_schema_16_x and route both 16.2/16.3 through it.
uprn_44012843 maps → SAP 79 (lodged 81).
- SAP-Schema-17.0: structurally identical to the full-SAP 17.1 schema (measured
sap_opening_types), so it parses with the 17.1 dataclass and reuses
from_sap_schema_17_1 with no normalisation. uprn_10023444324 → 80, uprn_
10023444320 → 81.
- Regression tests (16.3 dispatch, 17.0 dispatch) + sap_16_3.json / sap_17_0.json
fixtures; 0 new pyright errors. All 7 e2e UPRNs now map.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
SAP-Schema-16.2 (datatypes/epc/domain/mapper.py):
- 16.2 is structurally an RdSAP-17.1 cert under a different name; add
_normalize_sap_schema_16_2 (field renames + defaults) and dispatch to the
tested from_rdsap_schema_17_1 mapper. uprn_100020933699 maps → SAP 71.
- Honour a "Single glazed" windows description when multiple_glazing_type="ND"
(was defaulting to double) → RdSAP-21 code 5; eng 72→71 (lodged 70).
- 4 regression tests + sap_16_2.json fixture; 0 new pyright errors.
Flat party-wall fix (domain/sap10_calculator/worksheet/heat_transmission.py):
- Full-SAP flats carry flatness in dwelling_type, not property_type, so the
party-wall default fell through to the 0.25 house value instead of the RdSAP
Table-15 flat 0.0. Add _is_flat_or_maisonette_dwelling fallback + regression
test. uprn_10093116529 80→81 (matches the cert's lodged party u_value 0).
Accuracy corpus pins (tests/domain/sap10_calculator/test_real_cert_sap_accuracy.py):
- uprn_10093116543 (SAP-17.1 gas-combi semi): engine 81 (Elmhurst 77; documented
full-SAP→RdSAP residual — measured wall/floor U + PCDB boiler vs RdSAP defaults).
- uprn_10093116529 (SAP-17.1 g/f flat): engine 81 (Elmhurst 78).
devcontainer: add poppler-utils (pdfinfo) for the documents-parser PDF fixtures.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
RdSAP 10 §6.1 (PDF p.49) models a non-separated (heated) conservatory as
part of the dwelling. Until now the Summary §5 block was reduced to an
inert `has_conservatory` bool and the geometry (floor area, glazed
perimeter, glazing, storey height) was dropped on both paths.
Plumbing only — no cascade consumer yet (Slices B/C/D wire §3/§6):
- ElmhurstSiteNotesExtractor reads the §5 Conservatory block into a new
`Conservatory` site-notes record (scoped to §5 so the generic
"Floor Area"/"Room Height" labels can't collide with §4 dimensions);
- domain gains a frozen `SapConservatory` (floor area, glazed perimeter,
double/single glazing, thermally-separated guard, equivalent storey
count) on `EpcPropertyData.sap_conservatory`;
- the Elmhurst mapper threads it through, dropping SEPARATED
conservatories per §6.2 ("A separated conservatory ... is disregarded").
Verified against the simulated case-44 Summary (RefNo 001431): extracts
floor_area=12.0, glazed_perimeter=9.0, double_glazed=True, 1 storey.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The gov API lodges a §3.9.2 Simplified Type-2 RR (a room-in-roof bounded by
continuous common walls) under `room_in_roof_type_2` — gable + common-wall
lengths AND heights. The block was undeclared → `from_dict` dropped it →
neither the Type-1 nor Detailed path fired → the cascade's Simplified branch
billed the WHOLE A_RR shell (12.5√(floor/1.5)) at the Table-18-col-4 default
with no gable/common-wall deduction (over-count → under-rate; 7 corpus certs
at signed −5.02).
Fix: declare `RoomInRoofType2` on rdsap_schema_21_0_0/_21_0_1 + SapRoomInRoof,
and build `detailed_surfaces` by MIRRORING the worksheet-validated Summary
path (`_map_elmhurst_rir_surface`, is_simplified) rather than back-solving:
common wall → L × (0.25 + H) (billed at the main-wall U)
gable → L × (0.25 + H) − Σ (H − H_cw)²/2 (RdSAP 10 §3.9.2 + Table 4)
The gable correction sums all common walls (exposed/party/sheltered, incl.
the H=0 absent-gable negative-area case that deducts from the A_RR residual);
a Connected gable sums only the common walls it overtops. The
`gable_wall_type_*` code routes the kind (0/1/2/3 = Party/Exposed/Sheltered/
Connected). A raw-L×H prototype scattered; the §3.9.2 quadratic is the
missing piece.
Validation is cross-mapper parity, NOT a corpus back-solve: `_api_type_2_
surfaces` produces surfaces IDENTICAL to the Summary path on cohort cert
000565 (connected_wall 3.68, gable_wall_external 16.08/27.68, common walls,
and the −0.17 absent-gable quadratic), and 000565 is pinned to 1e-4 in the
harness — so the API RR fabric is now correct by construction. The remaining
type-2 cohort SAP scatter is unrelated per-cert causes (stone walls,
secondary fuel), not the RR.
Gauges: corpus within-0.5 67.6% → 67.9% (MAE 0.979 → 0.959); /tmp 71.7% →
71.8% (MAE 0.838 → 0.822). Harness 47/47 (000565 unchanged); regression =
the 3 pre-existing fails; pyright net-zero (65=65).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two compensating Summary-extractor bugs surfaced by simulated case 43 (a
2-BP mid-terrace with a detailed room-in-roof + a dry-lined extension wall).
Their fabric errors nearly cancelled (walls net −0.76 W/K), hiding both
behind a deceptively small +0.05 SAP delta.
Bug 1 — main/extension wall dry-lining never read. The §7 "Dry-lining:
Yes/No" line was parsed only for ALTERNATIVE walls; the main/extension
WallDetails dropped it, so a dry-lined solid wall was billed at its
un-adjusted base U. RdSAP 10 §5.8 + Table 14: a dry-lined uninsulated wall
adds R=0.17 → U = 1/(1/U_base + 0.17). Case 43 Ext1: solid brick 1.70 →
1.32. Added `WallDetails.dry_lined`, read it in the extractor (both the
main-wall builder and the As-Main copy), threaded it to the domain
`wall_dry_lined` (emit None when undried — cascade-equivalent to False,
keeps the field absent for the non-dry-lined majority).
Bug 2 — the LAST room-in-roof surface row's U over-read. The per-row token
scan stops at the next RIR-row name; the final surface (no successor) over-
read into the following section, shifting the trailing-token slotting and
silently zeroing its `default_u` (case 43 Common Wall 2: 1.90 → 0.00 → the
2.4 m² common wall billed at U=0 instead of the main-wall 1.90). Stop the
scan at the row's natural end — the "Yes"/"No" u_value_known flag plus the
trailing u_value numeric.
Case 43 now reproduces the P960 EXACTLY: (29a) walls 74.5800, (33) fabric
172.7844, continuous SAP 73.2332 = (258), CO2 3518.30 = (272), all <1e-4
(was SAP +0.0455 / CO2 −8.04). Harness 47/47 0 raised; regression = the 3
pre-existing fails; pyright net-zero (51=51).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Follow-on to the slope/stud slice. A Detailed RR (RdSAP 10 §3.9.2) can also
lodge `common_wall_*` — the wall separating the room-in-roof from the rest of
the cold roof void. Those fields were undeclared → `from_dict` dropped them →
`_api_rir_detailed_surfaces` omitted the common walls → the RR undercounted
wall heat loss → over-rate.
Fix: declare `common_wall_length/height_1/2` on `RoomInRoofDetails`
(21_0_0 + 21_0_1) and build `kind="common_wall"` surfaces (raw L × H area to
2 d.p.). The cascade's Detailed-RR branch already bills common walls at the
storey-below main-wall U (Table 4 p.22 "Common wall") and deducts their area
from the §3.10.1 residual roof — no calculator change. No insulation thickness
is read: common walls take the main-wall U, not a Table 17 RR-element U.
6 /tmp certs carry detailed `common_wall_length_1`: cohort mean|err| 2.43 ->
1.25 (all were over-rating; e.g. 2877-3059 +4.55 -> +2.79). Gauges: corpus
within-0.5 67.5% -> 67.6% (MAE 0.987 -> 0.979); /tmp 71.6% -> 71.7%
(MAE 0.846 -> 0.838). Harness 47/47 0 raised; regression = the 3 pre-existing
fails; pyright net-zero (65=65).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The gov-EPC API lodges a Detailed RR (RdSAP 10 §3.9, Figure 4) with up to
two sloping ceilings (`slope_*`) and two vertical stud/knee walls
(`stud_wall_*`) in addition to the gable + flat-ceiling surfaces. Those
slope/stud fields were undeclared on the 21.0.x schema, so `from_dict`
silently dropped them and `_api_rir_detailed_surfaces` built ONLY the gable
+ flat-ceiling surfaces. The (large) sloping roof and the knee walls
contributed ZERO heat loss → undercounted RR fabric loss → a systematic
over-rate.
Fix: declare `slope_*`/`stud_wall_*` on `RoomInRoofDetails`
(rdsap_schema_21_0_0 + _21_0_1) and build `kind="slope"` / `kind="stud_wall"`
surfaces in the mapper. The cascade's Detailed-RR branch already routes both
to the roof aggregate via `u_rr_slope` (Table 17 col 1) and `u_rr_stud_wall`
(Table 17 col 3) — RdSAP 10 §5.11.3, p.43-44 — so no calculator change is
needed (Summary path worksheet-validated by the 000565 detailed-RR fixtures).
insulation_type is left None to defer to the Table 17 col-(a) mineral-wool
default, mirroring the existing flat_ceiling branch.
15 /tmp certs carry `slope_height_1`: cohort mean|err| 4.26 -> 2.05, signed
+4.09 -> centred (14/15 were over-rating; e.g. 0390-2538 +5.95 -> +3.56).
Gauges: corpus within-0.5 67.3% -> 67.5% (MAE 1.020 -> 0.987); /tmp 71.4% ->
71.6% (MAE 0.882 -> 0.846). Harness 47/47 0 raised; regression = the 3
pre-existing fails; pyright net-zero (65=65).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The gov API lodges a manufacturer's declared cylinder loss factor
(kWh/day) in `sap_heating.cylinder_heat_loss`, in which case it leaves
the cylinder volume / insulation type / thickness None. That field was
undeclared on the 21.0.x schemas, so `from_dict` dropped it — then
`_cylinder_storage_loss_override` hit its insulation-None / volume-None
guards and returned None, dropping the §4 storage loss ENTIRELY. The
dwelling over-rated (the declared loss is typically ~1.5 kWh/day ≈
550 kWh/yr).
SAP 10.2 §4 branch a) (PDF p.136): when the declared loss factor is
known, storage loss (50) = (48) declared loss × (49) Table-2b
temperature factor — replacing the Table 2 V×L×VF computation.
- declare `cylinder_heat_loss` on RdSapSchema21_0_0/21_0_1.SapHeating +
EpcPropertyData.SapHeating; thread through the 21.0.x mappers.
- `cylinder_storage_loss_monthly_kwh` gains `declared_loss_kwh_per_day`:
when set, combined_55 = declared × TF (volume/insulation unused).
- `_cylinder_storage_loss_override` resolves the declared loss BEFORE the
insulation/volume guards (the gov omits those when the loss is lodged).
12 /tmp certs carry it (mean |err| 3.00 -> 2.51; the clean ones close
hard, e.g. 2360 2.65 -> 0.30, 0245 2.25 -> 0.53). Corpus within-0.5
67.0% -> 67.3% (MAE 1.025 -> 1.020); /tmp 71.2% -> 71.4% (0.889 ->
0.882). Worksheet harness 47/47; regression = only the 3 pre-existing
fails; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Roofs lodged insulated at rafters carry their thickness in a DEDICATED
gov-EPC API field, `rafter_insulation_thickness` (e.g. "225mm"), while
`roof_insulation_thickness` stays None (rafters aren't loft joists). That
field was undeclared on the 21.0.x schemas, so `from_dict` silently
dropped it — the rafter certs only *looked* redacted (roof EER 2-4 =
insulated, yet no thickness), and the cascade fell to the Table 18 col (2)
unknown default (2.30), badly under-rating them.
- declare `rafter_insulation_thickness` on RdSapSchema21_0_0/21_0_1 +
EpcPropertyData.SapBuildingPart (mirrors the existing
sloping_ceiling_/flat_roof_insulation_thickness dropped-field handling).
- thread it through `from_rdsap_schema_21_0_0/21_0_1` (older schemas get
None via getattr).
- `heat_transmission` prefers `rafter_insulation_thickness` over
`roof_insulation_thickness` when the part is at-rafters, so the measured
RdSAP 10 §5.11.2 Table 16 column (2) row applies (225 mm → 0.25).
Completes the rafters roof fix: with the real thickness read, the rafter
certs are recovered rather than over-stated — cert 3100-8675-0922-8628
(band E, rafters 225mm) +8.93 → +0.43 SAP. Corpus within-0.5 67.0%
(MAE 1.025) and /tmp 71.2% (MAE 0.889) — both NET ABOVE the pre-rafters
baseline (66.9% / 70.6%). Worksheet harness 47/47; regression = only the
3 pre-existing fails; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary §15.1 lodges "Cylinder Size: Value known" with the
measured volume in the "Cylinder Volume (l)" line — the Summary-path
equivalent of the gov-API "Exact" descriptor. The mapper had no entry for
"Value known" so `_elmhurst_cylinder_size_code` raised UnmappedElmhurstLabel,
and even once mapped the measured volume was never threaded through, so the
cascade dropped the cylinder storage loss (~468 kWh/yr) from (219) water
heating on every measured-volume-cylinder Summary.
Per RdSAP 10 §10.5 Table 28 (p.55) a measured cylinder volume is used
directly. Map "Value known" → cascade code 6 (Exact) and thread the §15.1
"Cylinder Volume (l)" value into SapHeating.cylinder_volume_measured_l, which
`_cylinder_volume_l_from_code` (cert_to_inputs.py:5281) already reads for
code 6 — mirroring the gov-API path (mapper.py:1575/1885).
Pins simulated case 39 (P960-0001-001431): an age-A mid-terrace on direct-
acting electric room heaters (SAP code 691, cat 10, control 2602) with
electric-immersion DHW off a 117 L "Value known" cylinder. The full
extractor→mapper→calculator cascade now reproduces the worksheet's SAP-rating
block EXACTLY — SAP value 36.6365 (band F) and (272) CO2 2056.0731 kg/yr,
with (219) water heating 2637.5049 and (255) total energy cost 1802.0039.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_synthesise_20_0_0_sap_windows` passed `schema.multiple_glazing_type`
straight into `_api_cascade_glazing_type`, which raised UnmappedApiCode on
the "ND" (Not Defined) string that the 20.0.0 corpus lodges alongside the
1-8 integer codes — failing the mapper-coverage guard on every ND-glazed
20.0.0 cert. Mirror the existing 18.0/19.0/17.x seams: route integer codes
through the cascade, fall the "ND" string back to the DG-modal default
(cascade code 2 → daylight g_L 0.80). Also corrects the 20.0.0 schema
field type `int` → `Union[int, str]` to match the data (as 18.0 already
does), which keeps the isinstance guard pyright-clean.
Pre-existing failure (present before this branch's recent commits), not in
the handover regression gate. Fixes all 15 RdSAP-Schema-20.0.0 ND certs;
test_mapper_corpus 6002/6002 pass. pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes `_elmhurst_secondary_fuel_from_sap_code` per SAP 10.2 §12
(PDF p.34: "Secondary heating systems and applicable fuel types are taken
from the room heaters section of Table 4a") + RdSAP 10 §10.4.1. Each
Table 4a room-heater code now resolves to its fuel CATEGORY's modal fuel:
- gas room heaters 601-613 → mains gas (26 → Table 32 1, 3.48 p/kWh)
- liquid room heaters 621-625 → heating oil (28 → Table 32 4, 5.44 p/kWh)
- solid room heaters 631-636 → house coal (11 → Table 32 11, 3.67 p/kWh)
- electric room htrs 691-694/699/701 → None (cascade electricity default)
Previously only the gas (601-613→26) and solid (631-634→11) blocks were
mapped; liquid heaters (621-625) and 635-636 fell through to None →
silently billed as electricity (13.19 p/kWh), a large mis-price for an
oil/solid heater. The prior slice raised on those; this maps them to the
correct category fuel instead, and keeps the raise ONLY for codes inside
the room-heater range (601-701) that are not a recognised Table 4a row.
The specific sub-fuel within a category (mains gas vs LPG vs biogas) is a
SEPARATE lodgement per §10.4.1 and is NOT exported in the Summary, so the
gas block stays the modal mains gas — worksheet "simulated case 37" lodged
its 605 live-effect fire on biogas (7.60 p/kWh), unrecoverable from the
Summary code alone (this is the entire +7 SAP case-37 gap: secondary
energy £131 + a separate biogas standing charge £70; every other line
matches the worksheet exactly, incl. (206) main efficiency 61%).
5 AAA tests, harness 47/47 (0 raised), pyright net-zero, regression clean,
corpus gauge unchanged (Elmhurst-path only).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary lodges only the secondary heating SAP code (Table 4a
Category 10), never its fuel. `_elmhurst_secondary_fuel_from_sap_code`
mapped the gas block (601-613 → mains gas) and solid block (631-634 →
house coal) to their modal defaults, but returned None for any OTHER
Category-10 code — and None makes the cascade SILENTLY bill the secondary
as electricity (13.19 p/kWh). For a fuel-fired heater (e.g. 621-625
liquid-fuel oil/bioethanol) that is a large, invisible mis-price.
Per the UnmappedElmhurstLabel strict-raise pattern (mirrors the wall_type
/ glazing label raises), a fuel-fired Category-10 code (601-699) outside
the mapped gas/solid blocks now RAISES instead of guessing. Electric room
heaters (691-699) keep returning None — electricity IS their fuel.
The gas block 601-613 still resolves to the modal default mains gas: the
Summary cannot distinguish mains gas from LPG/biogas, so an LPG or biogas
live-effect fire (worksheet "simulated case 37" used biogas at 7.60 p/kWh
vs our 3.48 p/kWh mains-gas default, a +7 SAP gap) is not recoverable from
the Summary export — that is a data-availability limit, not a guess we can
fix here. This commit closes the genuinely-silent-wrong path; the gas
sub-fuel remains the documented modal default.
Worksheet harness 47/47, 0 raised. 3 AAA tests, pyright net-zero,
regression clean, corpus gauge unchanged (Elmhurst-path only; the API path
lodges the secondary fuel explicitly).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the 17.0 synthesis seam over the shared _synthesise_reduced_field_windows
core (inherited 20.0.0 coefficients, ND glazing -> DG-modal default 2, per
ADR-0028). 17.0 glazed_type codes (1-4,7) are a subset of the verified 1-8
space. The 10 rich certs use lodged window_area directly; the windowless 990
synthesise a 4-way N/E/S/W split.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Dispatch RdSAP-Schema-17.0 through from_api_response, parse-fix the schema
(data-driven required->optional, validated against the 1000-cert 17.0 corpus
per ADR-0028 — incl. SapHeating.cylinder_insulation_type and the
has_hot_water_cylinder / has_fixed_air_conditioning / has_heated_separate_
conservatory flags), and port the defensive mapper reads (dwelling_type
str/dict/number, photovoltaic_supply guard, sap_floor_dimensions guard). All
1000 corpus certs now parse and map.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add the 19.0 synthesis seam over the shared _synthesise_reduced_field_windows
core (inherited 20.0.0 coefficients, ND glazing -> DG-modal default 2, per
ADR-0028). 19.0 glazed_type codes (1-4,6,7) are a subset of the verified 1-8
space. The 6 rich certs use lodged window_area directly; the windowless 994
synthesise a 4-way N/E/S/W split.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Dispatch RdSAP-Schema-19.0 through from_api_response, parse-fix the schema
(data-driven required->optional, validated against the 1000-cert 19.0 corpus
per ADR-0028), and port 18.0's defensive mapper reads (dwelling_type str/dict/
number, photovoltaic_supply guard, sap_room_in_roof Measurement coercion).
All 1000 corpus certs now parse and map.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The gov-EPC API surfaces the assessor's RdSAP-assessed per-element U-values
as `roof_u_value` / `wall_u_value` / `floor_u_value` on each building part.
These were undeclared on the RdSAP 21.0.0/21.0.1 schemas, so `from_dict`
silently dropped them, and `heat_transmission` re-derived each U from the §5.6
/§5.7/§5.11 construction-default cascade. The gov OPEN data routinely redacts
the backing insulation thickness, so that re-derivation mis-bills an insulated
element as uninsulated.
RdSAP 10 §5.1: a known element U-value (documentary evidence / the lodged
RdSAP output) is used directly in place of the construction-default cascade.
Per [[project_per_cert_mapper_validation_state]] the gov API carries RdSAP
OUTPUT, so the lodged U reproduces the official's element heat loss exactly.
Worst case in the 2026 sample: cert 7921-0052-0940-5007-0663, an age-C
"Pitched, sloping ceiling" (rc=8) top-floor flat lodging roof_u_value=0.2 with
no thickness. The cascade returned the uninsulated 2.30 W/m²K → SAP 56.9 vs
lodged 80 (-23.09, the single largest error in the sample). The roof override
alone recovers ~15 SAP; the wall override (lodged 0.34 vs cascade) closes the
rest of this cohort.
Override applies to the MAIN wall only (alt-wall sub-areas keep their own
per-area U) and the part's floor=0. Fires only when the rare field is present
(9 of 909 computed certs), so the Summary path — which never lodges these
API fields — is untouched.
API gauge: 67.1% → 67.7% within-0.5, mean|err| 1.024 → 0.992.
Worksheet harness: 47/47, 0 divergers (unchanged).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>