Khalim Conn-Kowlessar
f06a048a6f feat(modelling): ASHP option carries the composite per-dwelling cost
Slice 9 of ADR-0025 costing. _ashp_option now prices via Products.ashp_bundle_
cost(ashp_cost_inputs(epc)) instead of the flat catalogue scalar; the catalogue
row is still read for its material_id. Pinned on boiler-3: gas reuse dwelling
composes to 15600.60 (decommission 720 + pump 9720 + cylinder 2382.60 + reuse
distribution 2778) with 25% contingency.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 21:17:06 +00:00
Khalim Conn-Kowlessar
6f136a8d6a feat(modelling): classify ASHP existing system by fuel code
Slice 8 of ADR-0025 costing. _existing_system keys on the heating fuel code,
not the mains_gas flag -- the 001431 electric fixtures all lodge mains_gas=True
(gas available at the property) while heating electrically (fuel 30), which the
flag-based check misread as gas (and would have wrongly reused a non-existent
wet system). Electric/gas/oil/LPG map to their categories; empty details ->
NONE; unrecognised -> OTHER (gas-line fallback).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 21:10:45 +00:00
Khalim Conn-Kowlessar
f182f36802 feat(modelling): ashp_cost_inputs reads a dwelling into AshpCostInputs
Slice 7 of ADR-0025 costing: the modelling-layer interpretation half of the
split. ashp_cost_inputs derives existing system (mains_gas/fuel/SAP-code),
size band (floor area <= 75 m2), design heat loss (floor_area x 0.05 -- the
chosen proxy over HLC, ADR updated), radiator count (habitable + 3, floor-area
fallback) and reusable-wet-system flag. Catalogue math (Products) stays
EPC-free. ADR-0025 updated to record the floor-area pump-sizing choice.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 20:59:27 +00:00
Khalim Conn-Kowlessar
9f17a27766 feat(modelling): ASHP overlay resets water_heating_code to the HP end-state
The ASHP bundle is a fixed whole-system end-state (confirmed: always the same
contractor cylinder), so the hot-water arrangement is fixed too. The overlay now
sets water_heating_code=901 ("from main system") absolutely, so a combi (909/611)
or electric (903/908) before is reset to HW-from-the-heat-pump — previously the
overlay relied on the before already lodging 901 (true for boiler-1, not in
general). No-op for the boiler-1 pin (stays 1e-4). Cascade pins for combi /
electric-with-cylinder befores await example certs. ADR-0024.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 17:18:58 +00:00
Khalim Conn-Kowlessar
a9da21c4b6 feat(modelling): recommend_heating offers the ASHP bundle
Adds the air-source heat-pump Option to the competing "Heating & Hot Water"
bundles. Its overlay is the absolute heat-pump end-state (fixed representative
PCDB index 101413 + category 4 + control 2210 + HWP cylinder + single meter +
off mains gas), pinned against the relodged after-cert next slice. Eligibility
is physical/planning only (ADR-0024, research-grounded): any non-flat
house/bungalow, not listed/heritage (PlanningRestrictions.blocks_internal —
conservation is offered with a caveat, not excluded), not already a heat pump;
floor area / built form / fuel / fabric are deliberately not gates. recommend_
heating gains a restrictions param (defaulted). An already-HHR electric house
now correctly gets ASHP as a better end-state.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-06 16:56:00 +00:00
Khalim Conn-Kowlessar
b3badc9b10 test(modelling): HHRSH before/after cascade pins (001431) at 1e-4
The same absolute-target HHR overlay reproduces the common relodged after from
two different base systems (existing electric storage; "no system present"
electric) — proving the bundle is a true whole-system end-state. Closes one
named gap the pin surfaced: the relodged HHR cylinder lodges
cylinder_thermostat='Y', so HeatingOverlay + _fold_heating + the HHRSH overlay
gain cylinder_thermostat (ΔSAP 0.065 -> <1e-4). ADR-0024.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 19:09:23 +00:00
Khalim Conn-Kowlessar
b883e75da8 feat(modelling): recommend_heating offers the HHR storage bundle
The heating Recommendation Generator (HHRSH first). Emits one "Heating & Hot
Water" Recommendation whose competing whole-system bundles the Optimiser picks
from; this slice builds the high-heat-retention storage Option. Its overlay is
the absolute HHR end-state (Table 4a code 409 + control 2404 + dual off-peak
meter + off-peak electric cylinder), pinned against the relodged after-cert in
the next slice. Eligibility translates legacy is_high_heat_retention_valid to
structured predicates (electric or off-gas main, not already HHR/heat-pump).
mains_gas and the heat emitter are unchanged by the measure, so unset. ADR-0024.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 19:05:02 +00:00