ADR-0027 Reduced-Field Synthesis: certs with no per-window array now get total
glazing = 0.148 x TFA x band-multiplier (median + quartile multipliers fit from
the 1000 real 21.0.1 certs), split 4-way across N/E/S/W with width=area/4,
height=1.0; glazing_type routed through the verified 21.0.1 cascade. Also guard
optional PhotovoltaicSupply.none_or_no_details (a parse straggler). Corpus maps
983/1000, up from 974.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Required->optional defaults (kw_only + data-driven from corpus presence) so
993/1000 certs that omit sap_windows parse, and honest Union[str, DescriptionV1]
typing for description/dwelling_type which the corpus lodges as localised dicts
in ~half the certs. The never-run 20.0.0 mapper path now produces EpcPropertyData;
974/1000 corpus certs map (xpass), up from 7.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Sharpen the glossary to decouple deterministic old-schema re-mapping from
neighbour-prediction gap-fill (a separate, unimplemented ML path), and add
the Reduced-Field Synthesis term. ADR-0027 records the pre-SAP10 20.0.0
mapper's best-attempt synthesis (corpus-fit glazing 0.148xTFAxband, 4-way
orientation) and its trade-offs. Grill resume doc captures every resolved branch.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
An API audit flagged the solid-fuel room-heater space efficiencies
(_SPACE_EFF_BY_CODE 631-636) as reading the "Water" column of SAP 10.2
Table 4a. That was a misread: the two room-heater columns are (A)
minimum-for-HETAS-approved and (B) other appliances — BOTH are space
efficiency, not space/water. RdSAP defaults to column (B) when HETAS
approval is not lodged, which is what these values already hold and what
the reference software produces (Elmhurst worksheet "solid fuel 9", SAP
code 636 → (206) space efficiency = 70 = column B; flipping to column A
75 broke that pin and three sibling solid-fuel corpus pins).
No value change — add a pin test + spec-cited comment so the column-(A)/
(B) distinction is explicit and this misread can't recur.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:
- system_tune_up — standard controls (programmer + room thermostat +
TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned — time-and-temperature zone control (code 2110, type 3):
more SAP uplift for more cost
Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.
Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).
Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_separately_timed_dhw` returned True for any boiler+cylinder+from-main
cert, applying the SAP 10.2 Table 2b note b) ×0.9 temperature-factor
reduction unconditionally. For the lpg-boiler "before" worksheet (pre-
1998 LPG boiler SAP code 115 + 210 L cylinder, NO cylinder thermostat,
control 2113 "Room thermostat and TRVs" — no programmer) this dropped
the (53) temperature factor to 0.702 (= 0.60 × 1.3 × 0.9) where the
worksheet lodges 0.78 (= 0.60 × 1.3), under-counting cylinder storage
loss (55) by ~119 kWh/yr and over-rating SAP by ~0.25.
RdSAP 10 §10.5 (PDF p.57) "Hot water separately timed":
No programmer, pre-1998 boiler → No
Programmer, pre-1998 boiler → Yes
Post-1998 boiler → Yes
DHW is therefore NOT separately timed only when a pre-1998 boiler is
paired with a no-programmer control. Add the two SAP 10.2 Table 4c(2) /
Table 4b lookups (controls without a programmer = {2101, 2103, 2111,
2113}; pre-1998 gas/LPG boilers 110-119 + oil 124/125/128) and return
False for that combination; every other boiler+cylinder cert keeps the
separately-timed default, so the change is confined to old low-control
stock and the heating corpus + goldens are unchanged.
Effect: the full chain (Summary PDF → extractor → mapper → cert_to_inputs
→ calculator) now reproduces the lpg-boiler worksheet's §11a unrounded
SAP -6.6499 at abs < 1e-4 (was -6.4013). Full regression suite green bar
the 3 pre-existing unrelated fails.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
An LPG-boiler dwelling on the Summary → from_elmhurst_site_notes path
mapped to main_fuel_type=26 (mains gas), making it indistinguishable
from a mains-gas boiler downstream — wrong Table 12/32 cost / CO2 / PE
(bottled LPG is ~10.30 p/kWh vs mains gas 3.48), and it defeats any
"non-gas → gas only with a mains-gas connection" gate (an LPG dwelling
looks already-gas).
Root cause: the recommendation worksheets lodge the boiler carrier as
§15.0 "Water Heating Fuel Type: Bottled gas" (§14.0 carries only SAP
code 115, a Table 4b gas-family row, + "Main gas: Yes" in §14.2 — a
mains-gas CONNECTION, not the heating fuel). "Bottled gas" was absent
from `_ELMHURST_MAIN_FUEL_TO_SAP10`, so the §15.0 fuel resolved to None
and `_elmhurst_gas_boiler_main_fuel` fell through priority-1 to the
mains-gas meter flag → 26.
Map "Bottled gas" → 3 (bottled LPG MAIN heating): code 3 routes via
`API_FUEL_TO_TABLE_32`/`API_FUEL_TO_TABLE_12` → Table-code 3 (10.30 /
9.46 p/kWh). NOT the legacy "LPG bottled": 5 entry — API code 5 =
anthracite, and `canonical_fuel_code` resolves the same-valued Table-32
code 5 to anthracite (3.64 p/kWh), so a 5 here mis-prices the dwelling
as cheap solid fuel (verified: a 5 mapping moved SAP the WRONG way,
42.33 → 45.11; code 3 moves it to -6.40 vs the worksheet's -6.6499).
Also add 3 to `_GAS_LPG_MAIN_FUEL_CODES` so the §15.0-lodged bottled-LPG
water fuel is adopted as the boiler's space-heating carrier (priority 1)
instead of the meter flag.
Effect: main_fuel_type=3 (bottled LPG) and water_heating_fuel=3 (was
None). Mains-gas certs still → 26 (full regression suite green bar the 3
pre-existing unrelated fails); the MissingMainFuelType tripwire still
fires for genuinely-undeterminable carriers.
Spec: SAP 10.2 Table 12 / RdSAP 10 Table 32 (PDF p.95) — bottled LPG
main heating fuel code 3.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the `gas_boiler_upgrade` branch to `report._triggers_for`, mirroring the
generator's eligibility guard so a cohort report explains why the boiler upgrade
fired: the wet-boiler SAP code, the mains-gas connection that makes the gas
end-state installable, and the cylinder presence that shapes the bundle (combi
vs regular + cylinder fixes).
No golden API cert selects the boiler upgrade (it competes with — and on houses
loses to — the ASHP bundle within the one heating Recommendation), so the branch
is covered by a direct `_triggers_for` unit test, following the repo pattern for
testing internal helpers (cert_to_inputs).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pin the coal-boiler-with-cylinder upgrade and add the `boiler_flue_type`
end-state field. A solid-fuel (coal) boiler (fuel 11, SAP code 153) on a
mains-gas street converts to a gas condensing boiler (fuel 11->26, code 102) —
the non-gas->gas path for a solid-fuel system, eligible because code 153 is in
the wet-boiler solid-fuel range 151-161 and mains gas is present.
New `boiler_flue_type` HeatingOverlay field, routed to main_heating_details[0]
and set to 2 (room-sealed/balanced) on both boiler shapes: every relodged after
lodges flue type 2, but coal's before lodged none. The field is SAP-inert (the
cascade score is unchanged by it), so it is written purely for end-state
fidelity — the overlay now represents the installed condensing boiler's flue.
Validated via the overlay-equality unit tests.
The coal after predates the user-locked "always add a cylinder thermostat when
absent" rule, so it stale-lodged thermostat 'N'; the pin corrects it to the
rule's end-state 'Y' in-test (the gas with-cylinder after got the same
correction by re-lodging). The cylinder is already 80 mm insulated, so the
jacket is skipped and only the thermostat is added; controls (2106) are
unchanged. Cascade-pinned delta 0 (SAP/CO2/PE).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_elmhurst_dwelling_type` derived a flat's roof exposure from
`room_in_roof is not None`, so a top-floor flat whose roof is a plain
external "PS Pitched, sloping ceiling" (no room-in-roof) fell through to
"Mid-floor flat". The cascade's `_dwelling_exposure` then treats a
mid-floor flat's roof as a party ceiling (RdSAP 10 §5 / §3 — party
surfaces carry no heat loss) and drops the entire roof term: cert
001431's 105 m² roof at U=2.3 = 241.68 W/K (30) vanished, collapsing
(33) fabric heat loss 320.06 → 78.38 and over-rating SAP by ~5 points
(on top of the age-band roof-U bug — see prior commit).
Read the roof TYPE instead — the dual of the floor's "Another dwelling
below" signal. A flat's roof is a party ceiling only when its Elmhurst
code is S / A / NR (Same/Another dwelling or Non-residential space
above); F / PN / PA / PS are exposed external roofs, so the dwelling is
on the top storey. `has_exposed_roof = room_in_roof present OR
_elmhurst_roof_is_exposed(roof)` — which is exactly what the function's
own docstring already described as the intent ("RR present or external
roof"), now implemented.
With both upstream fixes the full chain (Summary PDF → extractor →
mapper → cert_to_inputs → calculator) reproduces the worksheet's §11a
unrounded SAP 56.3649 at abs < 1e-4, with (30)/(33)/(37) matching to
the decimal. Only flat fixture reclassified; 000784 (top-floor, RR) and
000910 (ground-floor) unchanged. Regression suite green bar the 3
pre-existing unrelated fails.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst Summary §3.0 "Date Built" lodges the per-building-part age
bands; the Main row reads "Main Property" / "C 1930-1949". But "Main
Property" ALSO heads the §4.0 Dimensions table, so the global
`_str_val("Main Property")` collides with it: when pdftotext renders
"3.0 Date Built:" glued onto its "Main Property" row token on one
layout line (as the recommendation worksheets do), the first standalone
"Main Property" match is the §4 dimensions header — returning its next
token "Floor" as the "age band".
That garbage age propagated to `u_roof`: for a "Pitched, sloping
ceiling" (PS) roof with no lodged insulation thickness, `u_roof` returns
the spec uninsulated U=2.3 for the correct age C but U=0.4 for the
unparseable "Floor" — collapsing the roof heat-loss term and inflating
SAP by ~14 points on the affected cert.
Scope the read to the Date-Built block (between "3.0 Date Built" and
"4.0 Dimensions") and take the first age row — a line beginning with a
single A-M band letter + space ("C 1930-1949", "A before 1900",
"J 2003-2006"). Building-part name rows never start that way, and the
Main row precedes any extension / room-in-roof rows.
Regression: full sap10_calculator + documents_parser suite green bar the
3 pre-existing unrelated fails (2 stone-wall U tests, test_total_floor_
area); the multi-bp / "A before 1900" fixtures (000516, 001431_case*,
6035) keep their age bands.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two more boiler-upgrade cascade pins, validating the existing generator across
fuels and cylinder states (no source change):
- oil combi: an oil boiler (fuel 28, code 130) on a mains-gas street converts to
a gas condensing combi (fuel 28->26, code 104). Proves the non-gas -> gas
conversion gated on a mains-gas connection (ADR-0024 revised).
- already-insulated cylinder: a gas boiler heating a pre-jacketed cylinder
(type 2 / 80 mm, no thermostat) gets a new boiler + a thermostat, with the
jacket NOT re-applied. Proves the cylinder path's skip-jacket branch against a
real cert. (Sourced from an LPG re-lodgement whose fuel the Summary mapper
reads as mains gas 26 — a separate LPG fuel-mapping gap, noted in the test.)
Both pin delta 0 (SAP/CO2/PE) against the relodged after.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Extend the gas-boiler-upgrade Option to combi (no-cylinder) dwellings and add
the controls upgrade shared by both boiler shapes. A dwelling has a cylinder or
it does not, so the one `gas_boiler_upgrade` Option is shaped per dwelling:
- no cylinder -> a gas condensing combi (Table 4b code 104), no cylinder fields
touched;
- a cylinder -> a regular boiler (code 102) heating it, with the conditional
cylinder jacket/thermostat (slice 1).
Controls: bring an inadequate boiler control up to full programmer + room
thermostat + TRVs (SAP 10.2 Table 4e Group 1 code 2106). "Inadequate" = the
Group-1 codes with NO room thermostat (2101, 2102, 2107, 2108, 2109, 2111) —
these lack boiler interlock (Table 4c(2) / footnote c) p.171), so adding a room
thermostat genuinely improves SAP. Room-thermostatted (2103/2104/2105/2106/2113)
or better zone controls (2110/2112) are left unchanged — never downgraded, so
no phantom uplift. The with-cylinder cert (control 2106) is therefore untouched
and its pin still holds at delta 0.
Validated by the combi before/after re-lodgement (cert 001431, gas boiler
upgrade - no cylinder): control 2111 "TRVs and bypass" -> 2106, fan flue
False->True, SAP code 112 -> 104. Cascade-pinned delta 0 (SAP/CO2/PE). Removed
the slice-1 placeholder test asserting no boiler Option fires without a cylinder
(the combi Option now correctly fires there).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.
The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:
- Target is always a gas condensing boiler, not fuel-preserving: every after
lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
mains-gas connection; electric boilers are left alone (electrification is the
upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
+ cylinder). The calculator derives the condensing seasonal efficiency from
the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
`fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
cylinder is below 80 mm (never downgrading a better one). Both are conditional
per-dwelling components, not a frozen overlay.
Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.
Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Session 9 ran five independent data-driven audits (profiler, dropped-field scan,
CO2/PE reconciliation, cross-provider LIG parity, HW-demand reconciliation) — all
converged on diffuse remaining gap — and shipped glazing Table-24 (+16 certs) +
HW-only heat-network DLF, taking 54.90% -> 56.8% within-0.5. The data-driven seam
is exhausted; session 10 switches to worksheet-level ground truth via the
summary-report-based per-cert audit. New agent prompt at HANDOVER_SUMMARY_AUDIT.md
with method, starter candidate certs, ruled-out list, and conventions.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The heat-network HW distribution-loss override fired only when the MAIN was
a heat network AND whc inherited from main ({901,902,914}). Water-heating-only
heat networks (SAP 10.2 Table 4a HW codes 950 boilers / 951 CHP / 952 heat
pump) were missed entirely: their Table 4a plant efficiency applied with NO
distribution loss, so the HW fuel was under-counted by the Table 12c DLF
(1.33-1.48x) → under-cost → over-rate.
RdSAP 10 §10 (spec p.36): a water-heating-only heat network is calculated 'for
plant efficiency, distribution loss and pumping energy - see Table 12c'. Added
a whc-gated branch (independent of the main) applying water_eff = plant_eff /
DLF — the per-kWh-generated cost model (q_generated = q_useful x DLF). Fires on
the WHC alone so a HW-only heat network with a non-network main (cert 9093, whc
950 + warm-air main 502) is covered.
The 3 corpus whc=950 certs all improve in |err|: 2153 +2.62->-0.48 (now within
0.5), 7220 +1.27->-0.97, 9093 +6.04->+3.60 (residual is its warm-air main, a
separate cause). within-0.5 56.66->56.79%, within-1.0 71.9->72.2%, mean|err|
down; only those 3 certs change. New AAA test pins the DLF scaling fires on the
WHC independent of the main. Goldens + gate green, pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Forcing-function guards so a lodged-but-unmapped code surfaces loudly instead
of silently taking a wrong-but-plausible default (the class that hid single
glazing as U=2.5 until this session). Four silent fallbacks converted to raise
on PRESENT-but-unmapped codes, while keeping the legitimate ABSENT (None)
defaults:
- _api_glazing_transmission: unmapped glazing_type -> UnmappedApiCode (was
None -> u_window all-None default 2.5).
- _api_cascade_glazing_type: unmapped glazing_type -> UnmappedApiCode (was
pass-through -> wrong g-value slot).
- seasonal_efficiency: a lodged code/category resolving in neither
_SPACE_EFF_BY_CODE nor the category/room-heater fallbacks -> UnmappedSapCode
(was blind 0.80 gas-boiler default, which 'catastrophically misrates heat
pumps and storage' per the table comment). Data-free calls keep 0.80.
- water_heating_efficiency: WHC in no SAP 10.2 Table 4a HW row ->
UnmappedSapCode (was blind 0.78). Absent code keeps 0.78.
Zero current-corpus impact (909 computed / 0 raises, 56.66% within-0.5
unchanged) — the code/efficiency tables are complete for today's data, so
these are guards for the ongoing audit + future data refreshes. Verified the
WHC table already covers 908 (multi-point gas) and 950 (HW heat network), so
those are NOT unmapped-code bugs. 8 AAA tests, goldens + gate green, pyright
net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>