# Coherent Heating System is owned by the synthesiser, not the calculator ## Status accepted ## Context A dwelling's heating is one conceptual **system**, but its fields are physically scattered across `EpcPropertyData` because that type mirrors the gov-API / RdSAP schema: the main cluster lives on `sap_heating`, the electricity tariff on `sap_energy_source.meter_type`, and hot-water flags (`has_hot_water_cylinder`, `solar_water_heating`) on loose top-level fields. Three places **synthesise** a heating system — a Measure Option (HHRSH/ASHP), a Landlord Override, and EPC Prediction's heating donor — and each was hand-copying a *different ad-hoc subset* of those fields. The override and the donor both omitted `meter_type`. Property 713406 (a predicted property whose landlord override set "Electric storage heaters") landed on the oil structural template's single-rate meter, so its overnight storage heat billed at the peak electricity rate: the calculator scored it **SAP 13 (G)** instead of **~50 (E)**, which then inflated the HHRSH measure to **+45.8 SAP** and pushed the plan to band A. ## Decision Treat **"a heating system"** as one named boundary (a **Coherent Heating System** — see CONTEXT.md). Whoever *synthesises* a heating system owns covering the whole boundary, with a fill policy suited to its source: - **Measure** → set a designed end-state (already did). - **Landlord Override** → *complete* the partial system the landlord named. Companion fields are **derived from the SAP code**, not hand-attached per archetype: the off-peak meter from the calculator's single off-peak classification (`OFF_PEAK_IMPLYING_HEATING_CODES`, SAP §12 Rules 1-2), and — where a field has no logical pairing — a **conservative** default (storage charge control → manual, SAP Table 4e 2401, the lowest-SAP storage control). So adding a heating archetype is just adding its code; coherent companions fall out and cannot be forgotten. - **EPC Prediction donor** → *carry* a real neighbour's whole coherent set (including its `meter_type`), since the donor is already internally coherent. **Coherence is a synthesis-time obligation, never a calculator normalisation.** A real lodged cert is scored exactly as lodged — the calculator must not "fix" a genuinely single-rate storage dwelling (its existing Unknown-meter inference is a separate, spec-faithful net for certs that lodged *Unknown*, and does not fire on an explicit meter). A contract test guards the override path: every off-peak code the archetype map can emit must drag a `Dual` meter, and every other code an explicit `Single` meter — a system switch can never leave the previous system's meter in place. ### Amendment: the gas-boiler companion set (property 728513) The storage-heater drag-along above covered electric systems; a landlord-named **gas boiler** was still synthesised as a sparse patch — only the SAP code (its meter/charge-control companions are `None` for a boiler). The replaced system's fields therefore bled through: an electric-storage flat reclassified as a gas combi kept `mains_gas=False`, heating category 7, the 2401 storage charge control, a `Dual` meter and an electric-immersion cylinder. That incoherent record gated out the gas-boiler-upgrade Measure and made the heating Generator read the dwelling as off-gas (offering HHRSH storage to a gas property). A gas-boiler archetype (Table 4b 102 regular / 104 combi / 120 CPSU) now drags its **whole** coherent set, code-derived like the storage companions: - **`mains_gas=True` + `main_fuel_type=26`** — a gas boiler implies a mains-gas connection and gas main fuel (so a heating-system-only override is self-coherent, not dependent on a companion `main_fuel` override). The `main_fuel` overlay independently sets `mains_gas=True` for a "mains gas" fuel; the two agree (both 26 / True) so composition stays order-independent. A non-gas `main_fuel` override (electricity/LPG/oil) leaves `mains_gas` **None** (unchanged) — an electric main heating does not prove there is no gas hob. - **`main_heating_category=2`** (gas boiler) and **`fan_flue_present=True`** — a modern room-sealed condensing boiler. - **`main_heating_control=2106`** (programmer + room thermostat + TRVs) — the landlord names the boiler, not its controls. Unlike the storage charge control (where the *conservative* lowest-SAP default is right because the control is genuinely unknown), a gas boiler installed under modern Building Regs must carry compliant controls, and the overlay already assumes the modern condensing efficiency for the boiler — so **assuming modern controls is the coherent, consistent default** (the alternative, a conservative "no controls" 2101, was considered and rejected as inconsistent with the assumed-modern boiler). The controls tune-up Measure still adds zone control on top. - **Hot water from the main system** (`water_heating_code=901`, `water_heating_fuel=26`) with the cylinder set from the boiler type — a combi (104) has **no** cylinder (`has_hot_water_cylinder=False`), a regular boiler / CPSU keeps one. (Mirrors Elmhurst: the cylinder choice is offered for a regular condensing boiler and greyed out for a combi.) - **`meter_type="Single"`** — a boiler is single-rate; the explicit Single meter overwrites any inherited storage `Dual` (the symmetric mirror of storage→Dual). A `mains_gas` flag was added to the `main_fuel` overlay. The companion-fuel and heating-system overlays now share the `mains_gas` / `main_fuel_type` fields rather than being strictly disjoint — accepted because they only ever agree for the mains-gas archetypes. The archetype map holds only mains-gas boilers, so a gas-boiler override always implies mains gas; a *contradictory* fuel override (gas boiler + a non-gas fuel) is out-of-scope incoherent landlord input (a finaliser-level validation, not an overlay concern). ## Considered Options - **Reify a `HeatingSystem` value object** all three produce/consume — rejected: overlaps `HeatingOverlay` and is a large, risky restructure for the value. - **A global coherence pass over the assembled effective EPC** — rejected: it would corrupt real lodged certs (force storage→dual on a genuine single-rate lodgement). Coherence must be scoped to synthesis points. - **Set `meter_type="Unknown"` and lean on the calculator's storage inference** — rejected as the primary mechanism: an explicit `Dual` is self-contained, matches the measure overlay, carries display value, and does not depend on a repo *extension* that could later be tightened toward spec. This amends [ADR-0029](0029-epc-prediction-from-comparable-properties.md) (the heating donor now carries the meter) and extends [ADR-0032](0032-landlord-override-epc-overlay.md) (the override overlay derives coherent companions).