Khalim Conn-Kowlessar f68cea27c9 fix(extractor): capture all 17 openable §11 windows on cert 001431
The Modelling glazing overlay's draught-proofing recompute (RdSAP 10 §8.1 —
a count over openable windows + doors) needs every openable window captured
with its draught_proofed flag. cert 001431's §11 lodges 17 windows but only
14 surfaced, via two distinct gaps:

1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
   data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
   laid out as a standalone keyword line with the U-value on the next line
   and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
   "<source> <U>" Manufacturer-line shape. Now anchored by a standalone
   data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
   the absent frame cell.

2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
   (U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
   backstop even though both are lodged on an "External wall". A window
   lodged on a wall is vertical by definition; guard the U-value backstop so
   it only fires when location/BP give no roof signal. The backstop's only
   pinned cert (000516 W6) hand-builds its sap_roof_windows and so is
   unaffected.

With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows, 14
draught-proofed — reconstructing Elmhurst's lodged 84% (16/19 = (14 windows
+ 2 doors) / (17 windows + 2 doors)). Full calculator + modelling +
orchestration suites green (1885 pass); the 2 glazing draught-proofing
xfails remain (the overlay recompute is the glazing agent's front).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-05 14:33:25 +00:00
..
fixtures test(modelling): lighting before/after cascade pins (001431) at 1e-4 2026-06-05 12:27:36 +00:00
__init__.py feat(modelling): Overlay Applicator folds EpcSimulation onto EpcPropertyData 2026-06-02 22:13:51 +00:00
_elmhurst_recommendation.py test(modelling): Elmhurst before/after cascade pin for cavity wall (#1154) 2026-06-03 09:36:53 +00:00
test_elmhurst_cascade_pins.py test(modelling): lighting before/after cascade pins (001431) at 1e-4 2026-06-05 12:27:36 +00:00
test_floor_recommendation.py refactor(modelling): group domain/modelling into generators/scoring/optimisation 2026-06-03 13:48:36 +00:00
test_glazing_recommendation.py feat(modelling): detect single-glazing code 15 + glazing before/after pins 2026-06-05 11:23:57 +00:00
test_lighting_recommendation.py feat(modelling): recommend_lighting upgrades all non-LED bulbs to LED 2026-06-05 12:23:27 +00:00
test_measure_dependency.py refactor(modelling): ventilation_dependency delegates to the generator + wraps 2026-06-03 14:04:17 +00:00
test_optimiser.py feat(modelling): ventilation-aware selection — price the forced dependency in 2026-06-03 16:16:26 +00:00
test_overlay_applicator.py feat(modelling): whole-dwelling LightingOverlay surface on EpcSimulation 2026-06-05 12:21:19 +00:00
test_package_scorer.py feat(modelling): Score carries the scored SapResult for billing 2026-06-03 17:20:45 +00:00
test_plan.py feat(modelling): Plan carries baseline/post Bills and derives the energy figures 2026-06-03 17:23:20 +00:00
test_plan_valuation.py feat(modelling): wire Valuation Uplift onto the Plan 2026-06-04 08:59:04 +00:00
test_roof_recommendation.py feat(modelling): room-in-roof safety guard defers the roof generator 2026-06-05 10:06:08 +00:00
test_scoring.py refactor(modelling): expose cascade_scores for the role-3 + bill cascade 2026-06-03 17:54:54 +00:00
test_valuation.py feat(modelling): ValuationUplift domain class (percentage-primary) 2026-06-04 08:33:19 +00:00
test_ventilation_recommendation.py feat(modelling): ventilation Recommendation Generator (detect + price) 2026-06-03 14:01:14 +00:00
test_wall_recommendation.py feat(modelling): explicit park-home guard in the solid-wall generator 2026-06-05 10:49:50 +00:00
test_window_extraction_001431.py fix(extractor): capture all 17 openable §11 windows on cert 001431 2026-06-05 14:33:25 +00:00