Model/domain
Khalim Conn-Kowlessar 0001c7d11f Slice S0380.153: SAP 10.2 Table 3 — not-separately-timed DHW for solid-fuel boilers
SAP 10.2 Table 3 (PDF p.160) provides three primary-loss rows keyed off
the DHW timing arrangement, the middle row giving winter h=5 / summer
h=3 for "Cylinder thermostat, water heating NOT separately timed".

Solid-fuel boiler systems (Table 4a codes 151-161 — independent boilers,
open-fire + back boilers, closed room heaters with boilers, range cooker
boilers, stoves with boilers) do not ship with dual programmers. Per
SAP 10.2 §9.2.4 (PDF p.27) these are "independent solid fuel boilers,
open fires with a back boiler and room heaters with a boiler" — the
appliance itself is the timer. DHW timing follows the burn schedule,
not a separate cylinder programmer, so the middle Table 3 row applies.

Pre-slice `_separately_timed_dhw` returned True for any cylinder +
non-electric HW fuel cert (the S0380.140 gate), routing solid-fuel
boilers through h=3 year-round (the third row, "Cylinder thermostat,
water heating separately timed"). That under-counted winter (59)m
by ~21 kWh/month × 8 winter months across the affected cohort, with
the under-counted water-heating gain propagating into MIT / SH / SAP.

New gate: `sap_main_heating_code in _TABLE_4A_SOLID_FUEL_BOILER_CODES`
(frozenset of {151, 153, 155, 156, 158, 159, 160, 161}) — added before
the existing cylinder-present fallback. The post-S0380.140 electric-
immersion / heat-pump / no-main branches are unchanged. Table 4b
liquid-fuel boilers (101-141) keep the True default — modern gas/oil
installations standardly include dual programmers and the worksheet
confirms `oil 1` / `oil pcdb 1..3` / `pcdb 1` are pinned exact at
h=3 year-round.

Worksheet evidence (heating-systems corpus property 001431):
  - solid fuel 3 (SAP code 160 range cooker boiler + WHC=901
    cylinder thermostat): worksheet (59)m winter = 64.58 (h=5, p=0)
    and summer = 41.92 / 43.31 (h=3, p=0). Cascade closes ΔSAP +0.30
    → −0.0000, Δcost −£6.84 → −0.00, ΔPE −214 → −0.00 (4-metric exact).
  - solid fuel 2 (SAP code 158 closed room heater + back boiler):
    same Table 3 fix narrows ΔSAP +2.06 → +1.86. Remaining ~1.86 SAP
    is the SAP 10.2 §12.4.4 immersion-in-summer rule for back-boilers
    (codes 156, 158) — the worksheet has summer (59)m = 0 because the
    Elmhurst P960 lodges `Summer Immersion: Yes` + the spec routes
    Jun-Sep HW through an electric immersion at η=100%. That's a
    bigger lift (monthly HW efficiency + fuel-split plumbing) and is
    a follow-up slice.

Other corpus variants: no impact (verified via cohort sweep). The
gate is narrow by SAP code so only the 2 affected variants move.

Extended handover suite: 897 pass / 0 fail (+1 from new AAA test).
Pyright net-zero (43 → 43, transient +1 fixed via `EpcPropertyData`
import on the new test's `_cylinder_epc_for` return annotation).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
data_transformation moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
epc pr review, move domain and orhcestration 2026-06-01 14:00:31 +00:00
sap10_calculator Slice S0380.153: SAP 10.2 Table 3 — not-separately-timed DHW for solid-fuel boilers 2026-06-01 16:28:48 +00:00
sap10_ml Slice S0380.109: Solid brick + insulation via §5.7 Table 13 + §5.8 Table 14 (RdSAP 10) 2026-06-01 16:28:47 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00